Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Acta ortop. bras ; 30(3): e244354, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1374153

RESUMO

ABSTRACT Objective: To evaluate the functional results of surgically correcting drop foot in patients with leprosy and compare their SALSA, Social Participation, and AOFAS score. Methods: Overall, 22 patients were subjected to posterior tibial tendon transfer via the subcutaneous route to the foot dorsum with an average follow-up of 56 months (min 12, max 70). In our sample, 15 of the enrolled patients were men and seven, women, aged between 20 and 73 years old who were operated on from January 2014 to December 2017. The Pearson's correlation test (r) was used to measure the correlation among those scales. A p < 0.05 was considered significant between the pre- and pos-operative AOFAS scale scores. Results: Pre-operative average AOFAS score was 59.6 (min 35, max 74) and 77.2 postoperative (min 36, max 97) (p < 0.0001), postoperative Salsa and Social Participation scale, 30.6 and 22.5, respectively. Statistical analysis suggests a strong positive correlation between AOFAS and Salsa scales (r = −0.83) and AOFAS and social participation (r = −0.78). Average dorsiflexion was 5.4 degrees. Conclusion: The surgical correction of drop foot positively affects the quality of life and social participation of patients with leprosy. Level of Evidence III, Retrospective Study.


RESUMO Objetivo: Avaliar o resultado funcional da cirurgia de correção de pé caído em pacientes hansênicos e comparar as escalas Screening of Activity Limitation and Safety Awareness (SALSA) e de Participação social pós-operatórias com o escore da American Orthopaedic Foot and Ankle Society (AOFAS). Métodos: Avaliamos 22 pacientes submetidos à transposição do tibial posterior para o dorso do pé com mínimo de seguimento de 12 e máximo de 131 meses operados entre janeiro de 2013 e dezembro de 2017. Utilizamos o coeficiente de Pearson (r) para medir o grau de correlação entre as escalas funcionais e consideramos o valor de p < 0,05 na análise dos valores pré e pós-operatórios da AOFAS. Resultados: A média da AOFAS foi de 59,6 no pré-op (mín 35, máx 74) e 77,2 no pós-op (mín 36, máx 97) (p < 0,0001) e das escalas SALSA e participação social de 30,6 e 22,5 no pós-operatório. A análise estatística demonstrou correlação positiva forte (r = −0,83) com as escalas SALSA e de participação social (r = −0,78) quando comparadas ao AOFAS. O grau de dorsiflexão atingido foi de 5,4 graus em média. Linha de pesquisa: Evidência clínica e organizacional, modelos assistenciais, educacionais e avaliação de qualidade em APS - Pós-graduação em Clínica Médica da Faculdade de Medicina da UFRJ. Conclusão: A melhora da função através da correção cirúrgica do pé caído possui correlação direta na melhora da qualidade de vida dos pacientes portadores de hanseníase. Nível de Evidência III, Estudo Retrospectivo.

2.
Acta ortop. mex ; 34(6): 371-375, nov.-dic. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1383451

RESUMO

Resumen: Introducción: El pie caído es una condición que suele manejarse con ortesis cortas, normalmente fabricadas en polipropileno. Se ha descrito también su tratamiento con ortesis de silicón, poco estudiadas pero que parecen mejorar el patrón cinemático de la marcha y, dada su comodidad, ser más aceptadas por los pacientes. Nuestro estudio describe cuáles son las características cinemáticas de la marcha y la satisfacción referida por los pacientes al usar una ortesis tobillo pie de silicón y compara dicho patrón con el no uso de la ortesis en casos con pie caído. Material y métodos: Estudio seudoexperimental descriptivo en pacientes con pie caído desde el año 2010 al 2012, en el que se evaluaron las variables cinemáticas del patrón de marcha a partir de laboratorios de marcha y además de la satisfacción de los sujetos con las ortesis de silicón y con el no uso de las mismas. Resultados: Cinco casos con pie caído fueron objeto del estudio. El análisis de marcha de los pacientes que usaron la ortesis constató una mejora de la posición del tobillo en el contacto inicial, en la velocidad promedio de marcha y en la longitud del paso, así como un aumento de la cadencia. Sin embargo, en términos de comodidad en comparación con el no uso de la ortesis, el resultado fue exiguo. Conclusiones: Las ortesis tobillo pie de silicón mejoran la posición del tobillo en el contacto inicial, así como los parámetros temporoespaciales de la marcha.


Abstract: Introduction: The Drop foot is a condition that is usually handled with short orthosis, usually made of polypropylene. It has also been described as being treated with silicon orthosis, little studied but which seem to improve the kinematic pattern of gait and, given its comfort, be more accepted by patients. Our study describes the kinematic characteristics of gait and patient satisfaction when using a silicon foot ankle orthosis, and compares this pattern to the non-use of the orthosis, in patients with a drop foot. Material and methods: Pseudo-experimental descriptive study in patients with dropped feet from 2010 to 2012, in which the kinematic variables of the gait pattern were evaluated from gait laboratories and in addition to the satisfaction of subjects with silicon orthosis and non-use of them. Results: Five patients with a drop foot were the subject of the study. Gait analysis of patients using the orthosis found an improvement in ankle position at initial contact, average walking speed and step length, as well as increased cadence. However, in terms of comfort compared to the non-use of the orthosis, the result was meager. Conclusions: Silicon foot ankle orthosis improve the position of the ankle in the initial contact, as well as the temporo-spatial parameters of the gait.


Assuntos
Humanos , Silicones , Tornozelo , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Desenho de Equipamento , Marcha , Articulação do Tornozelo
3.
The Korean Journal of Pain ; : 57-61, 2016.
Artigo em Inglês | WPRIM | ID: wpr-48900

RESUMO

Foraminal or extraforaminal Far Lateral Disc Herniations (FLDH) extending into or beyond the foraminal zone have been recognized as between 7-12% of all lumbosacral disc herniations. Conventional posterior laminectomy may not provide good access to a herniation that lies far lateral to the lateral margin of the pedicle. Use of the endoscopic technique through a percutaneous approach to treat such FLDH patients can decrease the surgical morbidity while achieving better outcomes. We made an effort to utilize the advantages of percutaneous endoscopic lumbar discectomy (PELD) and to determine the appropriate approach for FLDH at the level between the 5th Lumbar and first Sacral vertebrae(L5-S1). The authors present a case of an endoscopically resected lumbar extruded disc of the left extraforaminal zone with superior foraminal migration at the level of L5-S1, which had led to foot drop, while placing the endoscope in the anterior epidural space without facetectomy.


Assuntos
Humanos , Anestesia Local , Discotomia , Discotomia Percutânea , Endoscópios , Endoscopia , Espaço Epidural , , Deslocamento do Disco Intervertebral , Laminectomia , Dor Lombar
4.
Arq. neuropsiquiatr ; 65(3a): 628-632, set. 2007. graf
Artigo em Inglês | LILACS | ID: lil-460800

RESUMO

The aim of this study is analyze possible modifications in the cerebral cortex, through quantitative electroencephalography (qEEG) in patients submitted to a tendon transfer procedure (posterior tibialis) by the Srinivasan's technique. Four subjects (2 men and 2 women), 49.25 age average (SD±21.4) were studied. All subjects have been through surgical procedure due to leprosy and had, at least, two years of drop foot condition. The qEEG measured the electrocortical activity (relative power) between 8 and 25 Hz frequencies pre and post surgery. A paired t test analyzed all data (p<0,05). The results show significant alterations in the alpha relative power, electrodes F7 (p=0.01) and F8 (p=0.021). Altogether, based on findings of the current literature, we can conclude that the tendon transfer procedure suggests electrocortical alterations sensitive to specific qEEG bands.


O objetivo deste estudo é analisar possíveis modificações no córtex cerebral, através da electrencefalografia quantitativa (EEGq), em pacientes submetidos a um procedimento de transferência de tendão (tibial posterior) pela técnica de Srinivasan. Quatro sujeitos (2 homens e 2 mulheres), com média de idade de 49,25 anos (±21,4 DP) foram estudados. Todos os sujeitos realizaram o procedimento cirúrgico devido a hanseníase e tinham, pelo menos, dois anos de pé caído. O EEGq mediu a atividade electrocortical (potencia relativa) entre freqüências de 8 e 25 Hz, no pré e pós-operatório. Um teste t pareado analisou todos os dados (p<0,05). Os resultados mostram alterações significativas na potência relativa em alfa, nos elétrodos F7 (p=0,01) e F8 (p=0,021). Baseados em recentes achados na literatura, podemos concluir que o procedimento de transferência de tendão sugere alterações eletrocorticais sensíveis às freqüên-cias específicas do EEGq.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ritmo alfa , Ritmo beta , Mapeamento Encefálico , Córtex Cerebral/fisiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Transferência Tendinosa , Eletrofisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/cirurgia , Hanseníase/complicações , Hanseníase/fisiopatologia , Período Pós-Operatório , Cuidados Pré-Operatórios , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA