1.
Chinese Journal of Radiological Health ; (6): 484-488, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1003550

RESUMO

Objective To investigate the awareness of the Radiation Shielding Requirements for Radiotherapy Room–Part 2: Radiotherapy Room of Electron Linear Accelerators (GBZ/T 201.2—2011) among relevant practitioners in medical institutions as well as its implementation and application situation and collect relevant problems and suggestions for an evaluation of the scientificalness, standardization, and timeliness of the standard, and to provide a scientific basis for the further revision and implementation of the standard. Methods An online questionnaire survey was conducted among relevant employees in medical institutions providing medical linear accelerator radiotherapy across 22 provinces of China, which investigated the awareness, training, application, and revision suggestions related to GBZ/T 201.2—2011. The questionnaires were collected and analyzed. Results A total of 340 relevant practitioners filled out the questionnaire. Of the participants, 66.80% were physicists; 79.11% had an awareness of the standard; 56.18% ever participated in the standard-related training; but the survey results showed that the practitioners did not have a good knowledge of the standard’s content, and the training and promotion were not enough; 83.24% thought that the standard had been widely used; 17.60% thought that the standard needed to be revised; 76.76% thought that there was a need to add calculation examples; 88.82% thought that neutron shielding needed to be considered for the 10 MV X-ray accelerator room. Conclusion The standard has been widely known in the field of radiotherapy protection. With the development of radiotherapy technology, the standard should be revised to add calculation examples and consider neutron shielding in the 10 MV X-ray accelerator room. The standard is highly technical and difficult to grasp, so the promotion and implementation goals should be appropriate for different personnel groups, the training for employees at key posts should be strengthened, and the methods recommended in the standard should be uniformly used throughout the country.

2.
Chinese Journal of Radiological Health ; (6): 10-14, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965364

RESUMO

@#<b>Objective</b> To investigate the quality control and protection level of medical electron linear accelerators in Shanghai, China. <b>Methods</b> The startified random sampling method was used to cover tertiary, secondary and ungraded hospitals, and a total of 30 medical electron linear accelerators in 15 hospitals were tested for quality control and protection level according to relevant standards. <b>Results</b> Five medical electron linear accelerators failed the quality control test, with an overall inspection pass rate of 83.3% and a re-inspection pass rate of 100%. The pass rate of flatness of square X-ray irradiation field (5 cm × 5 cm)-(30 cm × 30 cm) was 83.3%, the pass rate of symmetry of square X-ray irradiation field was 96.7%, and other indices were qualified. All medical electron linear accelerator rooms passed the protection test. <b>Conclusion</b> The protection of medical electron linear accelerator rooms in Shanghai meets the requirements of national standards, and some indices do not meet the requirements of national standards in the preliminary inspection. The quality control of medical electron linear accelerators should be further strengthened to ensure the treatment effect of patients.

3.
Chinese Journal of Radiological Health ; (6): 407-411, 2021.
Artigo em Chinês | WPRIM | ID: wpr-974568

RESUMO

Objective To understand the level of quality control in medical linear accelerator in Guangxi, and to provide technical support for the health administrative department to make related standards. Methods To select medical linear accelerators in Guangxi by random sampling method. Results A total of 118 accelerators were checked in 2017—2019, the initial inspection pass rates of medical linear accelerators were 56.8% and re-inspect pass rate were 96.6%. Conclusion The quality control level of the radiology institutions needs to be improved. The health administrative department should strengthen routine management,it is necessary to implement quality control in medical linear accelerator.