Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 858-862, 2017.
Artigo em Chinês | WPRIM | ID: wpr-750313

RESUMO

@#Objective    To explore the diagnostic and treatment value of computed tomography (CT)-guided embolization coil localization of pulmonary nodules accurately resected under the thoracoscope. Methods    Between October 2015 and October 2016, 40 patients with undiagnosed nodules of 15 mm or less were randomly divided into a no localization group (n=20, 11 males and 9 females with an average age of 60.50±8.27 years) or preoperative coil localization group (n=20, 12 males and 8 females with an average age of 61.35±8.47 years). Coils were placed with the distal end deep to the nodule and the superficial end coiled on the visceral pleural surface with subsequent visualization by video-assisted thoracoscopic (VATS). Nodules were removed by VATS wedge excision using endo staplers. The tissue was sent for rapid pathological examination, and the pulmonary nodules with definitive pathology found at the first time could be defined as the exact excision. Results    The age, sex, forced expiratory volume in the first second of expiration, nodule size/depth were similar between two groups. The coil group had a higher rate of accurate resection (100.00% vs. 70.00%, P=0.008), less operation time to nodule excision (35.65±3.38 min vs. 44.38±11.53 min, P=0.003), and reduced stapler firings (3.25±0.85 vs. 4.44±1.26, P=0.002) with no difference in total costs. Conclusion    Preoperative CT-guided coil localization increases the rate of accurate resection.

2.
Korean Journal of Radiology ; : 412-416, 2012.
Artigo em Inglês | WPRIM | ID: wpr-72934

RESUMO

OBJECTIVE: Device- or technique-related air embolism is a drawback of various neuro-endovascular procedures. Detachable aneurysm embolization coils can be sources of such air bubbles. We therefore assessed the formation of air bubbles during in vitro delivery of various detachable coils. MATERIALS AND METHODS: A closed circuit simulating a typical endovascular coiling procedure was primed with saline solution degassed by a sonification device. Thirty commercially available detachable coils (7 Axium, 4 GDCs, 5 MicroPlex, 7 Target, and 7 Trufill coils) were tested by using the standard coil flushing and delivery techniques suggested by each manufacturer. The emergence of any air bubbles was monitored with a digital microscope and the images were captured to measure total volumes of air bubbles during coil insertion and detachment and after coil pusher removal. RESULTS: Air bubbles were seen during insertion or removal of 23 of 30 coils (76.7%), with volumes ranging from 0 to 23.42 mm3 (median: 0.16 mm3). Air bubbles were observed most frequently after removal of the coil pusher. Significantly larger amounts of air bubbles were observed in Target coils. CONCLUSION: Variable volumes of air bubbles are observed while delivering detachable embolization coils, particularly after removal of the coil pusher and especially with Target coils.


Assuntos
Embolia Aérea/etiologia , Embolização Terapêutica/efeitos adversos , Embolia Intracraniana/etiologia , Imageamento por Ressonância Magnética/métodos , Microscopia , Medição de Risco , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA