Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
Biomedical and Environmental Sciences ; (12): 510-516, 2023.
Artigo em Inglês | WPRIM | ID: wpr-981081

RESUMO

OBJECTIVE@#Diffuse large B-cell lymphoma (DLBCL) is often associated with bone marrow infiltration, and 2-deoxy-2-(18F) fluorodeoxyglucose positron emission tomography/computed tomography ( 18F-FDG PET/CT) has potential diagnostic significance for bone marrow infiltration in DLBCL.@*METHODS@#A total of 102 patients diagnosed with DLBCL between September 2019 and August 2022 were included. Bone marrow biopsy and 18F-FDG PET/CT examinations were performed at the time of initial diagnosis. Kappa tests were used to evaluate the agreement of 18F-FDG PET/CT with the gold standard, and the imaging features of DLBCL bone marrow infiltration on PET/CT were described.@*RESULTS@#The total detection rate of bone marrow infiltration was not significantly different between PET/CT and primary bone marrow biopsy ( P = 0.302) or between the two bone marrow biopsies ( P = 0.826). The sensitivity, specificity, and Youden index of PET/CT for the diagnosis of DLBCL bone marrow infiltration were 0.923 (95% CI, 0.759-0.979), 0.934 (95% CI, 0.855-0.972), and 0.857, respectively.@*CONCLUSION@#18F-FDG PET/CT has a comparable efficiency in the diagnosis of DLBCL bone marrow infiltration. PET/CT-guided bone marrow biopsy can reduce the misdiagnosis of DLBCL bone marrow infiltration.


Assuntos
Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Medula Óssea/patologia , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Linfoma Difuso de Grandes Células B/patologia
2.
Chinese Journal of Radiological Health ; (6): 668-672, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1006325

RESUMO

Objective To test and analyze the performance of Biograph Vision 600 PET/CT according to the NEMA NU2—2012 standard to achieve reliable, repeatable, and inter-system comparable performance measurement, and to provide a basis for future equipment stability testing and status detection. Methods The Biograph Vision PET equipment features a detector based on silicon photomultipliers, with 3.2 mm lutetium oxyorthosilicate crystals and full cover of the scintillation region. The spatial resolution, sensitivity, noise-equivalent count rate, scatter fraction, coincidence count rate, image quality, scatter correction, and time-of-flight resolution of Biograph Vision PET were tested by referring to the test model and method of the NEMA NU2—2012 standard. Results The Biograph Vision 600 PET equipment showed lateral and axial spatial resolutions of 3.69 mm and 3.81 mm at 1 cm off-center of the field of view, respectively and of 4.29 mm and 4.48 mm at 10 cm, respectively. The sensitivity was 17.5 kcps/MBq. The time-of-flight resolution changed from 210 ps to 215 ps as the count rate increased to the peak noise equivalent count rate. The NEMA peak noise-equivalent count rate was 247 kcps at 30.3 kBq/ml. The corresponding scatter fraction was 34.8%. With the NEMA module, the overall image quality contrast range was 73.6%-92.8%, and the background variability was 2.3%-6.5%; the mean lung residual error was 3.4%; and the time-of-flight resolution was 210 ps. Conclusion This performance test was performed according to the NEMA NU2—2012 standard, showing that all parameters were better than the ex-factory standard, which can provide a reference for other institutions selecting equipment and also provide a basis for future equipment stability testing and status detection.

3.
Chinese Journal of Radiological Health ; (6): 198-201, 2023.
Artigo em Chinês | WPRIM | ID: wpr-973178

RESUMO

@#The combination of conventional single-photon emission computed tomography (SPECT) and computed tomography (CT) may display the morphological changes of lesions and distribution of imaging agents, which is effective to improve the imaging sensitivity and specificity of tumors and non-tumor diseases. SPECT/CT is feasible to analyze the anatomical structure and metabolic status through displaying multi-site lesions with single imaging, thereby improving differential diagnosis and diagnostic accuracy of diseases. In addition, the novel mixed SPECT/CT device shortens the duration of image acquisition and provides precise attenuation correction and fusion imaging, which provides a scientific basis for rational selection of treatment regimens in clinical practice. This review describes the advances in clinical application of SPECT/CT.

4.
Organ Transplantation ; (6): 605-2023.
Artigo em Chinês | WPRIM | ID: wpr-978505

RESUMO

With the changes of the disease spectrum of liver transplantation and organ allocation system, more and more patients complicated with cardiovascular complications have entered the waiting list for liver transplantation. However, surgical stress, severe infection and adverse reactions of immunosuppressive drugs will significantly increase the risk of postoperative cardiac complications and affect the short-and long-term survival of the recipients. Therefore, comprehensive evaluation of cardiac structure and function of the recipients before liver transplantation is of significance for improving clinical prognosis of the recipients. In this article, the main causes for the increased risk of heart disease during the perioperative period of liver transplantation, the time and methods of heart disease risk assessment for liver transplant recipients were reviewed, and existing assessment approaches for common heart diseases before liver transplantation were illustrated, aiming to provide reference for further reducing the incidence of heart complications after liver transplantation, improving the survival rates of grafts and recipients and enhancing clinical prognosis.

5.
Journal of Preventive Medicine ; (12): 152-154, 2023.
Artigo em Chinês | WPRIM | ID: wpr-962276

RESUMO

Objective@#To investigate the changes of ambient dose equivalent rate in 99mTcO4- single photon emission computed tomography (SPECT) of the thyroid among patients with hyperthyroidism, so as to provide insights into radiation protection guidance.@*Methods@#Patients with hyperthyroidism who underwent 99mTcO4- SPECT of the thyroid in a tertiary hospital were enrolled. The ambient dose equivalent rate was measured at different time points following 99mTcO4- infection and at sites with different distances from patients' neck, and the effects of time post-injection, distance from patients' neck, 24-hour thyroidal radioiodine uptake and thyroid weight on the ambient dose equivalent rate were examined using a generalized linear mixed model.@*Results@#Totally 100 patients with hyperthyroidism were enrolled, including 24 men and 76 women and with a mean age of (38.5±14.0) years. The generalized linear mixed model was statistically significant (F=6 610.165, P<0.001), and patients' thyroid weight, time post-injection and distance from patients' neck significantly affected the ambient dose equivalent rate (F=57.967, 15 988.574, 11 200.645, all P<0.001), and the ambient dose equivalent rate positively correlated with patients' thyroid weight and negatively correlated with time post-injection and distance from patients' neck.@*Conclusions@#The ambient dose equivalent rate is affected by patients' thyroid weight, time post-injection and distance from patients' neck among patients with hyperthyroidism undergoing 99mTcO4- SPECT of the thyroid. Delay in contact with patients or keeping distance from patients may be effective for radiation protection.

6.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 257-260, 2023.
Artigo em Chinês | WPRIM | ID: wpr-961156

RESUMO

Objective @#To investigate the feasibility of epidural catheters in parotid gland duct anastomosis and the function of the affected side gland after parotid gland duct anastomosis. @* Methods@# Thirteen patients who were treated in the Department of Oral and Maxillofacial Surgery of Xuzhou Central Hospital using an epidural catheter as the scaffold for parotid gland catheter anastomosis were enrolled from Jan. 2019 to June 2021. The swelling, salivary fistula and catheter patency in the parotid gland area were evaluated two weeks after the operation. 99mTcO4- single photon emission computed tomography (SPECT) was used for quantitative detection of salivary gland secretion function@*Results@# Thirteen patients had no swelling or salivary fistula in the parotid gland area of the affected side two weeks after the operation, and the catheter secretion was unobstructed. There was no significant difference in the uptake rate between the parotid gland on the affected side and the parotid gland on the healthy side (t = -0.859, P = 0.399), and there was no significant difference in the excretion rate between the parotid gland on the affected side and the parotid gland on the healthy side (t = 0.693, P = 0.495). The parotid gland excretion function of the affected side was excellent three months after the operation.@*Conclusion @#Parotid duct anastomosis with an epidural catheter as the stent has good feasibility, and parotid gland secretion function recovers well after the operation, which is worthy of clinical application.

7.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.4): S143-S151, Nov.-Dec. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420855

RESUMO

Abstract Objective: The aim of this study is to find out if a single imaging test is enough to follow-up on an oncological post-treatment patient. In such a case, we would know which was more valuable after comparing the two, by CT or PET-CT. Methods: Between January 2012 and July 2018, we collected data from all patients with previous medical history who were treated with a head and neck squamous cell carcinoma in our hospital, through surgery or by using an organ preservation protocol which we had done. Patients were required to have a CT and a PET-CT performed in a maximum period of 30 days between techniques. We compared the post post-treatment stage given to each case by using only the physical examination (only the CT and the PET-CT), with the ones given by the Tumor Board. After treatment, we analysed the similarity through Cramer's V statistic test. Results: We performed a comparative analysis, obtaining a correlation of 0.426 between the stages given by the Tumor Board and the one assigned based on physical examination, without imaging techniques. By only using the computed tomography as an imaging method the correlation was 0.565, whereas with only the use of positron emission computed technology, it was estimated at 0.858. When we compared the statistical association between stages using exclusively one of the two imaging techniques, the correlation was 0.451. Conclusion: Independent of the modality, we have demonstrated that in patients who have received previous treatment, there was a higher correlation in the stages with respect to the diagnostic method conducted by the Tumor Board using PET-CT as the sole image. Level of evidence: Level 1.

8.
Arq. neuropsiquiatr ; 80(5,supl.1): 116-125, May 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1393956

RESUMO

ABSTRACT Background: the diagnosis of Parkinson's disease (PD) can be challenging, especially in the early stages, albeit its updated and validated clinical criteria. Recent developments on neuroimaging in PD, altogether with its consolidated role of excluding secondary and other neurodegenerative causes of parkinsonism, provide more confidence in the diagnosis across the different stages of the disease. This review highlights current knowledge and major recent advances in magnetic resonance and dopamine transporter imaging in aiding PD diagnosis. Objective: This study aims to review current knowledge about the role of magnetic resonance imaging and neuroimaging of the dopamine transporter in diagnosing Parkinson's disease. Methods: We performed a non-systematic literature review through the PubMed database, using the keywords "Parkinson", "magnetic resonance imaging", "diffusion tensor", "diffusion-weighted", "neuromelanin", "nigrosome-1", "single-photon emission computed tomography", "dopamine transporter imaging". The search was restricted to articles written in English, published between January 2010 and February 2022. Results: The diagnosis of Parkinson's disease remains a clinical diagnosis. However, new neuroimaging biomarkers hold promise for increased diagnostic accuracy, especially in earlier stages of the disease. Conclusion: Future validation of new imaging biomarkers bring the expectation of an increased neuroimaging role in the diagnosis of PD in the following years.


RESUMO Antecedentes: O diagnóstico da doença de Parkinson (DP) pode ser desafiador, principalmente nas fases iniciais da doença, embora tenha critérios clínicos atualizados e validados. Os avanços recentes em neuroimagem na DP, além do seu papel já consolidado de excluir causas secundárias e outras causas neurodegenerativas de parkinsonismo, tem contribuído para uma maior confiabilidade no diagnóstico em diferentes estágios da doença. Nesta revisão, nós destacamos os principais avanços de ressonância magnética e imagem do transportador de dopamina em auxiliar o diagnóstico de DP. Objetivo: realizar uma revisão acerca do conhecimento atual sobre o papel da ressonância magnética e imagem do transportador de dopamina no diagnóstico de doença de Parkinson. Método: Realizamos uma revisão não sistemática da literatura através da base de dados PubMed, utilizando as palavras-chave "Parkinson", "magnetic resonance imaging", "diffusion tensor", "diffusion-weighted", "neuromelanin", "nigrosome-1", "single-photon emission computed tomography", "dopamine transporter imaging". A busca foi restrita a artigos escritos em inglês, publicados entre janeiro de 2010 e fevereiro de 2022. Resultados: O diagnóstico de doença de Parkinson continua sendo um diagnóstico clínico, contudo, novos biomarcadores de neuroimagem são promissores para o aumento da acurácia diagnóstica, especialmente em fases mais precoces da doença. Conclusão: A validação futura de novos biomarcadores de imagem traz a expectativa de um maior papel da neuroimagem no diagnóstico de doença de Parkinson nos próximos anos.

9.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 179-185, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1011587

RESUMO

【Objective】 To explore the value of 18F-PSMA-1007 PET/CT in evaluating the primary tumor and infiltration range of prostate cancer. 【Methods】 We retrospectively collected 18F-PSMA-1007 PET/CT whole body imaging data of the patients who came to the Department of Urology, The First Affiliated Hospital of Xi’an Jiaotong University, from March 2019 to June 2021 due to suspected or diagnosed prostate cancer. No treatment was give before the examination. In addition, 51 patients underwent radical surgery after examination and obtained complete pathological results. We used a semi-automatic method to delineate the region of interest (ROI) of 40% SUVmax of prostate cancer foci, and obtained the metabolic parameters, namely, SUVmax, SUVmean, tumor metabolic volume (MTV) and total lesion metabolic (TLM). We also observed for infiltration of bilateral seminal vesicle glands and bladder. Correlation analysis was used to analyze the correlation of metabolic parameters with Gleason score and tumor grade grouping; McNemar test was used to analyze the accuracy of PSMA in evaluating the extent of prostate invasion. 【Results】 The PET/CT parameters SUVmax, SUVmean, TLM and Gleason score were not significantly correlated, but SUVmean was positively correlated with tumor grade (r=0.306, P=0.041). The pathological results showed a moderate correlation between the maximum diameter of the tumor and MTV (r=0.479, P=0.003). The sensitivity evaluated by PSMA-PET/CT to primary prostate tumor, capsule invasion, seminal vesicle gland invasion, and bladder invasion was 72.00%, 64.71%, 83.33%, and 25.00%, respectively; the specificity was 88.46%, 33.33%, 84.61%, and 95.74%, respectively; the accuracy was 80.39%, 52.94%, 86.27%, and 90.19%, respectively. 【Conclusion】 18F-PSMA-1007 PET/CT imaging has high accuracy in assessing primary tumor and the extent of invasion of prostate cancer, which indicates its value in clinical application.

10.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 752-756, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1006672

RESUMO

【Objective】 To prepare positron emission computed tomography (PET) molecular probes targeting macrophages using Nb119 and BCⅡ10 labeled with 68Ga nuclide. 【Methods】 To explore the labeling conditions of nanobodies with 68Ga nuclides, first, the anti-Vsig4 nanobody Nb119 and isotype control antibody BCⅡ10 were incubated with NOTA and then purified to obtain the chelating agent-modified NOTA-Nb119 and NOTA-BCⅡ10. The NOTA-Nb119 and NOTA-BCⅡ10 were further incubated with 68Ga. Finally, NOTA-Nb119 was identified by SDS-PAGE and MALDI-TOF methods, and the radiochemical purity was detected by radio-HPLC. 【Results】 The results of SDS-PAGE showed that the lanes of the successfully labeled NOTA-Nb119 had apparent hysteresis than the unlabeled nanobody band, which proved that the molecular weight of the labeled product was increased and NOTA successfully modified the nanobody. Subsequently, 68Ga nuclides could successfully label Nb119 and BCⅡ10. According to radio-HPLC detection, the radiochemical purity of NOTA-Nb119 and NOTA-BCⅡ10 labeled with 68Ga was greater than 90% and remained stable. 【Conclusion】 68Ga-labeled nanobodies have high radiochemical purity and high stability, indicating that this study can be applied to other nanobodies for modification and labeling and provides a practical and feasible method for the preparation of PET using nanobodies.

11.
JOURNAL OF RARE DISEASES ; (4): 72-77, 2022.
Artigo em Inglês | WPRIM | ID: wpr-1004987

RESUMO

Transthyretin-related amyloid cardiomyopathy (ATTR-CM) is a disease caused by the depo-sition of insoluble amyloid fibers formed by the misfolding of transthyretin precursor protein in the intercellular space of cardiomyocytes. This lesion may lead to myocardial dysfunction, cogestive heart failure, and death.When diagnosed earlier, the patient can be treated with drugs as soon as possible to intervene in the progress of the disease, so as to effectively improve the patient's prognosis.99mtechnetium-pyrophosphate (99Tcm-PYP)single-photon emission computed tomography (SPECT) has been widely used in the imaging examination of cardiac amyloidosis (CA) in recent years. While achieving early non-invasive diagnosis, accurate pathological classification can be obtained through Perugini visual score analysis, semi-quantitative analysis of heart to contralateral lung (H/CL) ratio, and SPECT image analysis. This article presents the application, methods, and the precautions of 99Tcm-PYPSPECT in the diagnosis of ATTR-CM, aiming to provide clinical reference for the application of this technology.

12.
Clinics ; 77: 100065, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1394289

RESUMO

Abstract Purpose: Budget cuts among other factors undermine the use of state-of-the-art equipment by many research groups. This doesn't mean that their scientific data are not reliable or top-notch. Resort to adaptations is a recurrent need in their reality. The aim of this study was to assess whether scintigraphy with 99mTcO4 is effective in evaluating the functionality of thyroid grafts after cryopreservation in rats. Material and methods: 24 rats were randomly distributed into 3 groups: Control Group (CG), without surgical procedure, Hypothyroidism Group (HTG), submitted to total thyroidectomy, and Transplanted Group (TG), with total thyroidectomy and cryopreservation of the thyroid gland for 7 days followed by grafting of a thyroid lobe. A protocol using a gamma camera imaging was conducted fourteen weeks after transplantation, and the whole body 99mTc, focusing on the topic of heterotopic thyroid uptake was evaluated. Results: The images acquired had good quality with no noise and artifacts that could jeopardize its analysis. On the 14th day, HTG displayed no thyroid uptake, and the TG had a clear uptake of the thyroid graft in the topography of the biceps femoris muscle. Presented data also showed that both equipment spatial resolution and alignment (4.375 mm) did not interfere with the physiological uptake of 99mTc by the thyroid graft. Conclusion: The viability and functionality of cryopreserved thyroid autotransplantation in rats who underwent total thyroidectomy were successfully accessed by the scintigraphy protocol developed. HIGHLIGHTS Adaptations in validated methods are a recurrent trend due to limited budgets which does not diminish their functionality. Scintigraphy with 99mTcO4 is effective in evaluating the functionality of thyroid grafts after cryopreservation in rats. It is possible to adapt human SPECT for other animals for clinical and research purposes.

14.
Braz. j. otorhinolaryngol. (Impr.) ; 87(1): 11-18, Jan.-Feb. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1153585

RESUMO

Abstract Introduction: Head and neck squamous cell carcinoma is the seventh most common malignant tumor. The advances in treatment have improved the global survival rates in the past years, although the prognosis is still grave. Objective: The aim of the present study is to evaluate the correlation between positron emission computed tomography and computed tomography at the time of staging a previously untreated head and neck squamous cell carcinoma, and to determine which of the two imaging techniques gives us more information at the time of initial diagnosis. Methods: Data from all patients diagnosed in our hospital of head and neck squamous cell carcinoma by a biopsy of any location or unknown primary tumor was collected, between January 2012 and July 2017. In all cases, computed tomography and positron emission computed tomography were performed with a maximum of 30 days difference between them and patients had not received any prior treatment to staging. The stage given to each case was compared based solely on the physical examination, only on the computed tomography/positron emission computed tomography, with respect to the stage given by the tumor board, observing the concordance obtained through Cramer's V statistical test. Results: We performed a comparative analysis obtaining a correlation of 0.729 between the stage given by the tumor board and the one assigned based on the physical examination without imaging techniques. When only using computed tomography as an imaging method, the correlation was 0.848, whereas with only the use of positron emission computed tomography it was estimated at 0.957. When comparing the statistical association between staging using exclusively one of the two imaging techniques, correlation was 0.855. Conclusion: Positron emission computed tomography is useful for the diagnosis of head and neck squamous cell carcinoma, improving the patient's staging especially when detecting cervical and distant metastases. Therefore, we consider that the use of positron emission computed tomography for the staging of patients with head and neck squamous cell carcinoma is a diagnostic test to be considered.


Resumo Introdução: O carcinoma espinocelular de cabeça e pescoço é o sétimo tumor maligno mais comum. Os avanços no tratamento melhoraram as taxas de sobrevida global nos últimos anos, embora o prognóstico ainda seja grave. Objetivo: Avaliar a correlação entre a tomografia computadorizada por emissão de pósitrons e a tomografia computadorizada no estadiamento de carcinomas espinocelulares da cabeça e pescoço não tratados previamente e verificar qual das duas técnicas de imagem nos fornece mais informações no momento do diagnóstico inicial. Método: Os dados de todos os pacientes diagnosticados em nosso hospital com carcinoma espinocelular de cabeça e pescoço por biópsia de qualquer região ou adenopatias de origem desconhecida foram colhidos no período entre janeiro de 2012 e julho de 2017. Em todos os casos, uma tomografia computadorizada e uma tomografia computadorizada por emissão de pósitrons foram realizadas com um máximo de 30 dias de diferença entre elas. Nenhum paciente deveria ter recebido tratamento antes do estadiamento. O estadiamento atribuído a cada caso foi comparado com base apenas no exame físico, pela tomografia computadorizada ou apenas pela tomografia computadorizada por emissão de pósitrons, com relação ao estadiamento concedido pela margem tumoral, observou-se a concordância obtida pelo teste estatístico de V de Cramer. Resultado: Realizamos a análise comparativa obtendo uma correlação de 0,729 entre o estadio concedido pela margem tumoral e aquele atribuído com base no exame físico sem técnicas de imagem. Usando apenas a tomografia computadorizada como método de imagem, a correlação foi de 0,848, enquanto que a correlação com a tomografia computadorizada por emissão de pósitrons foi estimada em 0,957. Ao comparar a associação estatística entre o estadiamento usando exclusivamente uma das duas técnicas de imagem, foi de 0,855. Conclusão: Tomografia computadorizada por emissão de pósitrons é útil para o diagnóstico de carcinoma espinocelular de cabeça e pescoço, melhora o estadiamento, especialmente na detecção de metástases cervicais e à distância. Portanto, concluimos que seu uso para o estadiamento de pacientes com carcinoma espinocelular de cabeça e pescoço é um exame diagnóstico a ser considerado.


Assuntos
Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/terapia , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Sensibilidade e Especificidade , Compostos Radiofarmacêuticos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Estadiamento de Neoplasias
15.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 289-295, 2021.
Artigo em Chinês | WPRIM | ID: wpr-1006752

RESUMO

【Objective】 To compare the detection efficiency of 99mTc-MDP SPECT and PSMA PET/CT in detecting bone metastases in patients with prostate cancer. 【Methods】 We retrospectively collected data of 83 patients diagnosed with prostate cancer in The First Affiliated Hospital of Xi’an Jiaotong University from March 2019 to July 2020, concurrent with 99mTc-MDP SPECT and 18F-PSMA PET/CT whole body imaging in the same period. Two nuclear medicine physicians attending a double-blind interpretation compared whether the patients with bone metastases detected by two imaging methods under different PSA levels and different Gleason scores, and further analyzed the location and number of inconsistent bone metastases as well as the ability of PET/CT to detect metastatic lesions other than bone. 【Results】 Compared with 99mTc-MDP SPECT, 18F-PSMA PET/CT could detect more prostate cancer patients with bone metastases (P<0.001). When TPSA<10 ng/mL or >20 ng/mL, the detection rate of PET/CT for bone metastasis was higher than that of whole body bone scan (P<0.05). When Gleason score>8, PET/CT was more effective in detecting bone metastasis. The detection rate was higher than that of whole body bone scan (P<0.05). The lesions with positive PET/CT but not diagnosed by bone scan were mainly located in the chest bone, spine bone, and pelvic bone; the lesions with positive bone scan but missed by PET/CT were also more common in chest bone, with low nuclide uptake. The average SUVmax was 2.62±0.47 (1.60-3.30), and adjacent to the liver, spleen or salivary glands with higher metabolism. There were 21/51 (41.18%) cases of lymph node metastasis found outside of bone, 5/51 (9.80%) cases of lung metastasis, and 1/51 (1.96%) cases of liver metastasis. 【Conclusion】 18F-PSMA PET/CT imaging is significantly superior to 99mTc-MDP whole-body bone imaging in diagnosing bone metastasis of prostate cancer, and it can detect metastases other than bone.

16.
Chinese Journal of Internal Medicine ; (12): 661-664, 2021.
Artigo em Chinês | WPRIM | ID: wpr-911430

RESUMO

To investigate the predictive value of [ 18F]fluorodeoxyglucose-positron emission computed tomography(PET)/CT for disease progression in patients with dermatomyositis (DM) and interstitial lung diseases (ILD). Sixty-seven DM patients who underwent [ 18F] FDG-PET/CT imaging were retrospectively analyzed from January 2012 to September 2017 at PLA General Hospital. Their clinical manifestations and imaging characteristics were recorded. Compared with those chronically progressed (C-ILD), patients with rapid progression (RP-ILD) had significantly higher erythrocyte sedimentation rate (ESR) and standardized uptake value (SUV) in lungs ( P<0.05). In patients with RP-ILD, SUV in lungs was positively correlated with age, disease course, and ESR. Receiver operating characteristic curve analysis suggested that when lung SUV cut off value was 2.25, the sensitivity and specificity to predict disease progression was 77.8% and 72.8%, respectively. Old age, longer disease course, low creatine kinase level, higher ESR, and high SUV are prognostic factors for DM-associated ILD.

17.
Chinese Journal of Radiological Medicine and Protection ; (12): 653-658, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910372

RESUMO

Objective:To compare the differences in the delineation of the gross tumor volume (GTV) and lymph nodes of nasopharyngeal carcinoma (NPC) patients using computerized tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18F-FDG PET/CT), and to investigate the optimal standard uptake value (SUV; relative to the MRI-based delineation) for the automatic delineation of GTV using PET. Methods:A total of 53 NPC patients proposing to receive radiotherapy were selected for this study. The CT, MRI, and PET images of each patient were obtained before radiotherapy. Then GTV and positive lymph nodes were delineated on these three types of images. They were individually named GTV MRI, GTV CT, GTV PET2.5 (SUV=2.5), Lymph MRI, Lymph CT, and Lymph PET2.5 and compared. The GTV ∩2.5 (overlapped GTV) was obtained through the alignment of MRI and PET/CT images. Meanwhile, GTV was delineated on PET images using thresholds of SUV=4.0, 4.5, 5.0, and 5.6, obtaining GTV PET4.0, GTV PET4.5, GTV PET5.0, and GTV PET5.6. Then their volume and Dice similarity coefficients (DSCs) were compared. Results:Compared to GTV MRI, GTV CT decreased by 1.73% ( P>0.05) and GTV PET2.5 increased by 21.34% ( t=-3.52, P < 0.05) in the three types of images. The volume of Lymph PET2.5 was 1.61 and 1.87 times the volume of Lymph MRI and Lymph CT, respectively ( t=-4.12, -5.18; P< 0.05). The volume of high-SUV lymph nodes was 4.07 times the volume of lymph nodes with low SUVs or SUV=0 ( t=5.50, P< 0.05) on PET images. The DSC between GTV PET4.0and GTV MRI was 0.78 ± 0.27, which was lower than that between GTV PET2.5 and GTV MRI (0.84 ± 0.18). However, GTV PET4.0 approximated to GTV ∩2.5 ( P>0.05). Conclusions:Compared to CT and 18F-FDG PET/CT, MRI shows more accurate boundaries of GTV and lymph nodes. When 18F-FDG PET/CT was adopted to automatically delineate GTV, the GTV delineated using SUV=4.0 was closer to GTV MRI.

18.
Chinese Journal of Radiological Medicine and Protection ; (12): 534-538, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910353

RESUMO

Objective:To discuss the problems existing in the implementation of the Chinese health industry standard WS 523-2019 by testing SPECT device.Methods:Under the WS 523-2019 standards, a total of 10 SPECT devices were tested with regard to their SPECT reconstructed spatial resolution (SRSR), system planar sensitivity (SPS), system spatial resolution (SSR), whole body system spatial resolution (WSSR), intrinsic uniformity (IU), intrinsic count rate performance (ICR), intrinsic spatial resolution (ISR) and intrinsic spatial linearity(ISL).Result:Under the requirements of WS 523-2019 standards for qualified limits, there are 3 devices with ISL unqualified and the rest of the performances qualified. The new standards basically can meet the clinical requirements and reflected the overall performance of SPECT.Conclusions:The distance between the radiation source and the surface of the detector has great influence on the spatial resolution.In the measurement of ISL, there must be a lead grid separately in the x and y directions. The lead grids with the parallel slits shall be positioned on the detector with the center slit centered on the detector. It is suggested to add rotation center in the new standards.

19.
Chinese Journal of Endocrine Surgery ; (6): 353-357, 2021.
Artigo em Chinês | WPRIM | ID: wpr-907805

RESUMO

Objective:To investigate the diagnostic efficacy of 99Tc m-MIBI SPECT dual-phase imaging combined with rapid parathyroid hormone detection in thyroid cancer with suspected parathyroid mass. Methods:Data of 76 cases of thyroid cancer with suspected cervical parathyroid gland tumors receiving colorectal ultrasonography or CT examination in Thyroid Surgery Department of the Affiliated Cancer Hospital of Zhengzhou University were retrospectively analyzed. Blood samples were taken before surgery to detect parathyroid hormone. Parathyroid hormone was quickly detected after clamping the tumor blood vessels during surgery. Based on the postoperative pathological results, the sensitivity, specificity, accuracy and consistency of various diagnostic methods were evaluated. The ROC curve was drawn by measuring the value of the parathyroid gland concentration after reduction of the tumor blood vessels by clamping the tumor.Results:The sensitivity and accuracy of the 99Tc m-MIBI SPECT dual-phase imaging combined with the rapid detection of parathyroid hormone in diagnosis of suspected parathyroid tumors were (96.5%, 93.4%) better than the 99Tc m-MIBI SPECT dual-phase imaging methods (77.6%, 78.9%) and intraoperative rapid detection methods (86.2%, 82.8%) , and had a high consistency with the results of pathological examination, Kappa value of 0.81. The combined detection rate of suspected parathyroid tumors was significantly higher than that of 99Tc m-MIBI SPECT dual-phase imaging and rapid intraoperative detection, but there was no significant difference between 99Tc m-MIBI SPECT dual-phase imaging and intraoperative rapid detection. The area under the ROC curve of the reduction ratio a value after clamping the blood vessels of the tumor was 0.774, and the standard error was 0.073. The difference was statistically significant ( P<0.001,95% CI:0.631-0.918) . According to the results obtained by the ROC, the index (sensitivity + specificity-1) was plotted on the ordinate and a was the abscissa. The maximum value of the Jordan index was 0.584. The a value corresponding to this point was 0.52. 0.52 is the DCP value. The corresponding sensitivity, specificity, accuracy was 86.2%,72.2%,and 82.9%. Conclusion:99Tc m-MIBI SPECT dual-phase imaging combined with rapid parathyroid hormone detection during surgery has good diagnostic value for thyroid cancer with suspected parathyroid mass, and is completely consistent with pathological diagnosis.

20.
Nucleus (La Habana) ; (67): 22-27, ene.-jun. 2020.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1143355

RESUMO

Resumen Los anticuerpos monoclonales marcados con radionucleidos fueron en sus inicios ampliamente empleados para el estudio de diversas enfermedades, fundamentalmente oncológicas mediante la inmunogammagrafía. Estos fueron poco a poco sustituidos por moléculas con mejores prestaciones como los péptidos y la 18F-fluordesoxiglucosa (18F-FDG). No obstante, en el presente siglo, la amplia introducción de la inmunoterapia produjo un cambio de paradigma en cuanto al empleo de los anticuerpos monoclonales radiomarcados para la adecuada selección y seguimiento de los pacientes a ser tratados con inmunoterapia, resurgiendo la inmunotomografía por emisión de fótón único (inmuno-SPECT), la inmunotomografía por emisión de positrones (inmuno-PET) y la imagen corregistrada con la tomografía axial computarizada (TAC), como modalidades de gran valor en el manejo del cáncer. El objetivo del presente trabajo fue brindar una panorámica acerca de la evolución de la imagen nuclear con anticuerpos monoclonales radiomarcados y sus principales aplicaciones en el tiempo, fundamentalmente en el estudio de los pacientes con cáncer.


Abstract In the beginning, radionuclide-labeled monoclonal antibodies were widely employed for the study of various diseases, mainly oncological, by immunoscintigraphy. They were gradually replaced by molecules with better performance such as peptides and 18F-FDG. However, in the present century, the wide introduction of immunotherapy produced a paradigm shift in the use of radiolabeled monoclonal antibodies for the proper selection and follow-up of patients to be treated with immunotherapy, re-emerging of the immune-single photon emission tomography (immuno-SPECT), the immune-positron emission tomography (immuno-PET) and the co-registered image with computed tomography (CT) as imaging modalities of great value in the management of cancer. The aim of the present work was to provide an overview of the evolution of nuclear imaging with radiolabeled monoclonal antibodies and their main applications over the time, mainly in the study of patients with cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA