RESUMO

Abstract Objective: to analyze the cleaning process of gastroscopes, colonoscopes and duodenoscopes in eight in-hospital health services. Method: a cross-sectional study conducted with 22 endoscopes (eight gastroscopes, eight colonoscopes and six duodenoscopes), and microbiological analysis of 60 samples of air/water channels (all endoscopes) and elevator (duodenoscopes), in addition to protein testing. Descriptive statistics with calculation of frequencies and central tendency measures was used in data analysis. Results: the processing of 22 endoscopes was monitored with microbiological analysis for 60 channels. In the pre-cleaning procedure, in 82.3% (14/17) of the devices, gauze was used in cleaning the insertion tube. Incomplete immersion of the endoscope in detergent solution occurred in 72.3% (17/22) of the cases, and in 63.6% (14/22) there was no standardization of filling-in of the channels. Friction of the biopsy channel was not performed in 13.6% (3/22) of the devices. In the microbiological analysis, 25% (7/32) of the samples from the stored endoscopes were positive for microbial growth (from 2x101 to 9.5x104 CFU/mL), while after processing, contamination was 32% (9/28). Protein residues in the elevator channel were detected in 33% of duodenoscopes. Conclusion: the results indicate important gaps in the stages of pre-cleaning and cleaning of endoscopes that, associated with presence of protein residues and growth of microorganisms of epidemiological importance, indicate limitations in safety of the processing procedures, which can compromise the disinfection processes and, consequently, their safe use among patients subjected to such tests.


Resumo Objetivo: analisar o processo de limpeza de gastroscópios, colonoscópios e duodenoscópios em oito serviços de saúde intra-hospitalar. Método: estudo transversal com 22 endoscópios, sendo oito gastroscópios, oito colonoscópios e seis duodenoscópios, e análise microbiológica de 60 amostras dos canais de ar/água (todos os endoscópios) e elevador (duodenoscópios), além de teste de proteína. Na análise dos dados, utilizou-se estatística descritiva, com cálculo de frequências e medidas de tendência central. Resultados: o processamento de 22 endoscópios foi acompanhado com análise microbiológica de 60 canais. Na pré-limpeza, em 82,3% (14/17) dos equipamentos, foi utilizada gaze na limpeza do tubo de inserção. A imersão incompleta do endoscópio em solução detergente ocorreu em 72,3% (17/22) dos casos, e em 63,6% (14/22) não havia padronização do preenchimento dos canais. A fricção do canal de biópsia não foi realizada em 13,6% (3/22) dos equipamentos. Na análise microbiológica, 25% (7/32) das amostras dos endoscópios armazenados foram positivas para crescimento microbiano (2x101 a 9,5x104 UFC/mL), enquanto após o processamento, a contaminação foi de 32% (9/28). Resíduos de proteína no canal do elevador foram detectados em 33% dos duodenoscópios. Conclusão: os resultados apontam lacunas importantes nas etapas de pré-limpeza e limpeza dos endoscópios que, associadas à presença de resíduos de proteína e ao crescimento de microrganismo de importância epidemiológica, sinalizam limitações na segurança do processamento, que podem comprometer os processos de desinfecção e consequentemente seu uso seguro entre pacientes submetidos a tais exames.


Resumen Objetivo: analizar el proceso de limpieza de gastroscopios, colonoscopios y duodenoscopios en ocho servicios de salud intrahospitalarios. Método: estudio transversal con 22 endoscopios, de los cuales ocho eran gastroscopios, ocho colonoscopios y seis duodenoscopios, y análisis microbiológico de 60 muestras de los canales de aire/agua (todos los endoscopios) y elevador (duodenoscopios), además de prueba de proteínas. En el análisis de los datos se utilizó estadística descriptiva, con cálculo de frecuencias y medidas de tendencia central. Resultados: el procesamiento de los 22 endoscopios fue monitoreado con el análisis microbiológico de 60 canales. En la prelimpieza, en el 82,3% (14/17) de los equipos se utilizó gasa para limpiar el tubo de inserción. En el 72,3% (17/22) de los casos la inmersión del endoscopio en solución detergente fue incompleta y en el 63,6% (14/22) no hubo estandarización del llenado de los canales. La fricción del canal de biopsia no se realizó en el 13,6% (3/22) de los equipos. En el análisis microbiológico, el 25% (7/32) de las muestras endoscópicas almacenadas dio positivo para crecimiento microbiano (2x101 a 9,5x104 UFC/ml), mientras que después del procesamiento, la contaminación fue del 32% (9/28). Se detectaron residuos de proteína en el canal elevador en el 33% de los duodenoscopios. Conclusión: los resultados indican que hay importantes lagunas en las etapas de prelimpieza y limpieza de los endoscopios que, junto con la presencia de residuos de proteínas y del crecimiento de microorganismos de importancia epidemiológica, indican limitaciones en la seguridad del procesamiento, que pueden comprometer los procesos de desinfección y, por ende, el uso seguro en los pacientes que se someten a esos procedimientos.


Assuntos
Humanos , Desinfecção , Infecção Hospitalar , Contaminação de Equipamentos/prevenção & controle , Estudos Transversais , Endoscópios/microbiologia , Detergentes
2.
Belo Horizonte; s.n; 2021. 202 p.
Tese em Português | LILACS, InstitutionalDB, BDENF, ColecionaSUS | ID: biblio-1451377

RESUMO

Procedimentos endoscópicos representam um importante recurso diagnóstico e terapêutico amplamente utilizado nos serviços de saúde. Entretanto, durante o exame, ao entrar em contato com o trato gastrointestinal, o endoscópio se torna altamente contaminado pela microbiota humana. Portanto, a limpeza meticulosa e desinfecção desse equipamento é extremamente crítica na prevenção de infecção e segurança do seu uso. Diante disso, objetivou-se avaliar a prática do processamento de gastroscópios, colonoscópios e duodenoscópios nos serviços de saúde intra ­ hospitalares. Tratou-se de um estudo transversal, com apoio da Secretaria de Estado de Saúde de Minas Gerais (SES-MG), realizado em oito serviços de endoscopia intrahospitalares em Belo Horizonte, sendo avaliado o processamento de 22 equipamentos endoscópicos e 60 amostras dos canais dos equipamentos. A coleta de dados ocorreu por meio de entrevista, observação das práticas adotadas, análise microbiológica dos canais de ar/água e, no duodenoscópio acrescentou-se a análise do canal do elevador, somado à aplicação de teste de proteína após a limpeza. A análise dos dados se deu por meio de estatística descritiva, com cálculo de frequências, medidas de tendência central. A maioria dos serviços dispuham de endoscópios com média global de uso de 7,3 anos. As manutenções preventivas ocorriam em média a cada 90 dias. Protocolos de processamento não estavam ao alcance dos profissionais de forma facilitada em 50% (4/8) dos serviços. A auditoria do processo de limpeza é realizada em 62,5% (5/8) dos serviços, por meio de teste adenosina trifosfato (ATP) bioluminescência. Nenhum serviço possuía rotina de vigilância dos pacientes submetidos a procedimentos endoscópicos. Todas as etapas do processamento apresentaram não conformidades com as diretrizes nacionais e internacionais, destacando-se a etapa da limpeza como a de maior desafio, seguida da secagem, pré-limpeza, teste de vedação e armazenamento. Na pré-limpeza, verificou-se que 86,4% (19/22) dos equipamentos não era padronizada a compressa para limpeza externa do equipamento, sendo adotada a gaze. O teste de vedação não foi realizado em 36,4% (8/22) dos equipamentos. Na limpeza, 72,7% (17/22) dos endoscópios não foram imersos em solução detergente e 63,6% (14/22) dos equipamentos, os canais eram friccionados com esvova de tamanho único. Nenhum serviço havia padronização de tempo para a secagem final dos canais. No armazenamento, os armários convencionais em MDF foram encontrados em 37,5% (3/8) dos serviços, sem qualquer ventilação. Quanto ao potencial de contaminação, após o processamento verificou-se um predomínio de Pseudomonas, sendo que 28,5% eram resistentes a carbepenem e 21,4% com perfil intermediário. Serratia marcescens resistente a carbapenem foi isolada em 33,3% das amostras. Em relação aos testes de avaliação da limpeza, 33% (2/6) dos duodenoscópios apresentavam resíduos de proteína no canal do elevador. Conclui-se que as práticas cotidianas do processamento de endoscópios em serviços de saúde não têm sido realizadas conforme as evidências e as recomendações científicas.


Endoscopic procedures are an important diagnosis and therapeutic resource broadly used in health services. However, during the procedure, when contacting the gastrointestinal tract, the endoscope becomes highly contaminated by human microbiota. A thorough cleaning and disinfection of these equipment is of critical importance in the prevention of infection and safety of its use. Therefore, the aim was to evaluate the practice of processing gastroscopes, colonoscopes and duodenoscopes in intra-hospital health services. The study was a crosssectional one, supported by Minas Gerais State Department of Health, performed in eight inhospital endoscopic services in Belo Horizonte. Data collection occurred through interviews, observation of practices, microbiological analysis of air/water channels, and in the duodenoscope, was added analysis of the elevator channel, adding to protein test applications after cleaning. 60 samples from the equipment channels were analyzed. Data analysis was performed using descriptive statistics, with frequency calculation, measures of central tendency. The majority of services had endoscopes with global average use of 7,3 years. Preventive maintenance occurred in an average cicle of 90 days. At pre-cleaning, it was found that 86.4% (19/22) of the endoscopes did not standardized compress for the equipment external cleaning, and gause was adopted. The sealing test was not used at 36.4% (8/22) of the equipment. For cleaning, 63.6% (14/22) of endoscopes did not had compatible brushes for each channel, and 72.7% (17/22) of the equipments were not immersed in a detergent solution. At storage, conventional MDF cabinets were found, at 37.5% (3/8) of services, without any air circulation. Processing protocols at 50% (4/8) of services were not available to professionals in an easy way. All processing steps presented nonconformities with national and international guidelines, highlighting the cleaning stage as the most challenging one, followed by drying, pre-cleaning, sealing test and storage. The cleaning process audit took place at 62.5% (5/8) of services, through adenosine triphosphate (ATP) bioluminescence. As for disinfection, all services monitored the solution with MEC tape. None of the services had a surveillance routine of patients undergoing endoscopic procedures. As for the contamination potential, after processing there was a predominance of Pseudomonas, 28.5% were resistant to carbepenem and 21.4% had an intermediate profile. Serratia marcescens carbapenem resistant, was isolated at 33.3% of the samples. Regarding cleaning validation tests, 33% (2/6) of duodenoscopes showed protein residues in the elevator channel. It is concluded that the daily practices endoscopes processing in health services have not been carried out in accordance with scientific evidence and recommendations.


Assuntos
Humanos , Masculino , Feminino , Esterilização , Desinfecção , Controle de Infecções , Endoscópios Gastrointestinais , Segurança do Paciente
3.
Rev. eletrônica enferm ; 23: 1-13, 2021.
Artigo em Inglês, Português | BDENF, LILACS | ID: biblio-1253784

RESUMO

Objetivo: Identificar na prática clínica gaps que interferem na efetividade do processamento endoscópico. Método: Revisão integrativa de artigos publicados entre 2008­2020, identificados em bases de dados por meio de descritores controlados em Ciências da Saúde, adotando-se a estratégia PICO. Os gaps identificados foram classificados segundo nível de evidência (IA, IB, IC, II). Resultados: Foram encontrados 18 artigos registrando 64 gaps, 26,6% no nível de evidência IA e 40,6% IB, predominando: ausência/inadequação da secagem (55,5%), limpeza manual sem escovação dos canais/escovas inapropriadas (50%), omissão do teste de vedação (38,8%), inadequações no armazenamento (33,3%) e no uso da solução desinfetante (27,7%), tempo de imersão ou monitorização da concentração mínima eficaz, ausência de pré-limpeza (16,6%), transporte incorreto para a sala de processamento (11,1%). Conclusão: As diretrizes fortemente recomendadas por entidades internacionais e nacional têm sido descumpridas, representando aspectos críticos no processamento dos endoscópios que implicam em potenciais falhas na segurança do paciente.


Objective: This paper aimed to identify gaps in clinical practice that interfere with the effectiveness of endoscopic processing. Method: Integrative review of articles published between 2008 and 2020, identified in databases through controlled descriptors in Health Sciences, adopting the PICO strategy. The identified gaps were classified according to the level of evidence (IA, IB, IC, II). Results: Eighteen articles were found, recording 64 gaps, 26.6% at the level of evidence IA and 40.6% IB, predominating: absence/inadequate drying (55.5%), manual cleaning without brushing the inappropriate channels/brushes (50%), omission of the sealing test (38.8%), inadequate storage (33.3%) and use of the disinfectant solution (27.7%), time of immersion or monitoring of the minimum effective concentration, absence of pre-cleaning (16.6%), incorrect transportation to the processing room (11.1%). Conclusion: It was concluded that guidelines strongly recommended by international and national entities have been breached, representing critical aspects in the processing of endoscopes that imply potential failures in patient safety.


Assuntos
Controle de Infecções , Endoscópios Gastrointestinais , Desinfecção
4.
Arq. gastroenterol ; 47(3): 219-224, jul.-set. 2010. tab
Artigo em Inglês | LILACS | ID: lil-567299

RESUMO

CONTEXT: The endoscopic procedure safety depends on the use of an adequately reprocessed device which quality is related to each of its operational steps. OBJECTIVE: To characterize the reprocessing of endoscopes using glutaraldehyde in endoscopy services METHODS: Study was conducted by observing the reprocessing of 60 endoscopes from 20 medical practices of the municipality of Goiânia, GO, central area of Brazil. RESULTS: This study showed failure in all reprocessing steps. The pre-washing was performed in 24 (40.0 percent) of the endoscope. In the cleaning steps, was identify the improper use of enzymatic detergent, and in 27 (45.0 percent) cases, the brushing of internal channels was not performed. All 60 endoscopes were submitted to this disinfectant. However, for 33 (55.0 percent) of the cases the internal channels was not filled. The total immersion of endoscope in the glutaraldehyde was not performed in 39 (65.0 percent) cases. The recommended minimum total immersion time for exposure to 2 percent glutaraldehyde solution was followed only for 12 (20.0 percent) endoscopes. There was no filter for water treatment used in the rinse of most endoscopes 54 (90.0 percent) and to dry the internal channels only 6 (10.0 percent) of them used compressed air. Adequate storing conditions were identified. CONCLUSION: Considering the particularities of the endoscope and its reprocessing, it is imperative to establish protocols to ensure the quality of the disinfection and the prevention of cross-contamination.


CONTEXTO: A segurança do procedimento endoscópico depende do uso de um aparelho adequadamente reprocessado e a qualidade do reprocessamento está relacionada a cada uma das etapas operacionais desse processo. OBJETIVO: Caracterizar o reprocessamento de endoscópios pelo uso do glutaraldeído em serviços de endoscopia. MÉTODOS: Estudo conduzido em 20 serviços de endoscopia digestiva do município de Goiânia, GO. A amostra se constituiu de endoscópios utilizados para endoscopia digestiva alta. Os dados foram obtidos mediante observação direta de 60 reprocessamentos de endoscópios. Resultado - Foram observadas falhas em todas as etapas do reprocessamento. Em 24 (40,0 por cento) endoscópios foi realizada a pré-lavagem. Na etapa da limpeza, foi identificado o uso inadequado do detergente enzimático e em 27 (45,0 por cento) não foi realizada a escovação dos canais internos. Todos os 60 endoscópios foram submetidos ao desinfetante, entretanto para 33 (55,0 por cento) não foi aspirado o produto nos canais internos. O tempo de exposição ao glutaraldeído foi observado apenas para 12 (20 por cento) dos endoscópios. O enxágue de 54 (90,0 por cento) dos endoscópios ocorreu com o uso de água não-filtrada e, para a secagem dos canais internos, apenas 6 (10,0 por cento) utilizaram o ar comprimido. Foram identificadas condições adequadas para o armazenamento. CONCLUSÃO: Considerando as particularidades do reprocessamento dos endoscópios é imperativo estabelecer protocolos para assegurar a qualidade da desinfecção e a prevenção da contaminação cruzada.


Assuntos
Desinfetantes/farmacologia , Desinfecção/métodos , Endoscópios Gastrointestinais/microbiologia , Contaminação de Equipamentos/prevenção & controle , Glutaral/farmacologia , Brasil , Infecção Hospitalar/prevenção & controle , Desinfecção/normas , Reutilização de Equipamento/normas
SELEÇÃO DE REFERÊNCIAS