Zhonghua laodong weisheng zhiyebing zazhi ; Zhonghua laodong weisheng zhiyebing zazhi;(12): 471-473, 2018.
Artigo em Chinês | WPRIM | ID: wpr-806625

RESUMO

Objective@#A solvent desorption-gas chromatography method for determination of ethylal in workplace air has been established.@*Methods@#Ethylal in workplace air was collected by activated carbon tube and desorbed with carbon disulfide, and the desorption solutions were analysed by capillary column GC with FID detector.@*Results@#The method presented a good linearity in the range of 0.87~34 800.00 mg/L of ethylal in the standard solution, with the correlation coefficient being r=0.999 7. The limit of detection and the limit of quantification of this method were respectively 0.20 mg/L and 0.80 mg/L, and the minimum detectable concentration and the minimum quantification concentration of this method were respectively 0.17 mg/m3 and 0.60 mg/m3 per 1.50 L of air.The within-run precision of the method was 2.93%-6.20%, and the between-run precision 3.67%-6.44%. The desorption efficiency between 94.22%-97.27%. Ethylal in activated carbon tube could be kept at least 7 days at room temperature without significant loss.@*Conclusion@#The method could be used for determination of ethylal in workplace air.