1.
ImplantNews ; 12(6): 789-794, nov.-dez. 2015. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: biblio-850952

RESUMO

Objetivo: analisar a influência da distribuição dos implantes nas microdeformações da mandíbula, no carregamento da infraestrutura da prótese total parafusada. Material e métodos: foram utilizados seis modelos de mandíbulas confeccionados em poliuretano, distribuídos em três grupos com dois modelos cada, nos quais foram instalados cinco implantes (protocolo de Brånemark) utilizando três configurações distintas. Grupo I: os implantes foram instalados com espaçamentos equidistantes de 9 mm entre eles. Grupo II: implantes intermediários foram instalados a 8 mm do implante mais distal. Grupo III: implantes intermediários foram instalados a 8 mm do implante mais anterior. Extensômetros (strain gauges) foram fixados nas áreas adjacentes aos implantes, para determinar as microdeformações ocorridas após o carregamento, e seis barras de Ni-Cr, que foram parafusadas nos implantes, foram confeccionadas. Uma força de 200 N foi aplicada em três pontos da barra: parte anterior, cantiléver direito e cantiléver esquerdo. As microdeformações apresentadas sob a forma de gráficos foram tabuladas e levadas a teste estatístico. Resultados: as maiores microdeformações ocorreram quando foram carregadas as extremidades (direita ou esquerda) da barra, e que não houve diferença significativa de microdeformações entre as três configurações estudadas. Conclusão: a distribuição de carga numa prótese total fixa parafusada sobre implantes ainda é complexa e deveria ser estudada em modelos clínicos correspondentes.


Objective: to analyze the influence of implant distribution on mandibular microdeformation upon loading of an infrastructure fabricated for a complete fixed, screw-retained, implant-supported dental prosthesis. Material and methods: six polyurethane mandibular models were made and distributed into three groups (n=2). Each model received five dental implants. Three distinct configurations were used; Group I: all implants were positioned 9 mm apart each other; Group II: the most central implants were placed 8 mm from the most distal implant. Group III: the most central implants were placed 8 mm from the most anterior implant. Strain gauges were affixed at implant adjacent areas to determine the microstrain values after loading. Six cast and laser-welded Ni-Cr infrastructures were fabricated and fastened to the dental implants with a 10 Ncm torque. A 200 N load was applied at three predetermined points: anterior portion, and at the right and left cantilevers. The Kruskal-Wallis test was used to compare microstrain values among groups. Results: 1) Forces applied at the cantilever induced microstrain around all dental implants, 2) The greatest deformations were observed at the right and left extremities and 3) With forces in the anterior portion, great deformation values were observed at the bone adjacent to the most posterior implants. However, no differences were seen for microstrain values among groups. Conclusions: load distribution for complete fixed, screw-retained, implantsupported prosthesis is still a complex factor and must be investigated in correspondent clinical models.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Osseointegração , Técnicas In Vitro
2.
Bauru; s.n; 2013. 136 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-707696

RESUMO

Atualmente, os implantes são utilizados em diversos tipos de tratamento na reabilitação oral. Para manutenção da osseointegração, é essencial que o conjunto prótese/implante/osso seja submetido a forças às quais estejam aptos a suportar. Os diferentes tipos de desadaptações das infraestruturas das próteses sobre implantes são fatores que podem contribuir para o aumento das tensões na região peri-implantar. Este estudo teve como objetivo avaliar a influência das desadaptações angulares unilaterais na distribuição de tensões na região periimplantar de pilares tipo UCLA, no momento da pré-carga e carga axial. Infraestruturas de CoCr, confeccionadas utilizando-se pilares tipo UCLA, foram divididas em quatro grupos: Grupo A (adaptado), Grupo B, Grupo C e Grupo D (50, 100 e 200 μm de desadaptação unilateral angular por vestibular, respectivamente). Cada grupo foi representado por quatro infraestruturas (n=4). Quatro implantes (4.1mm/15mm) foram posicionados em uma matriz metálica, onde posteriormente foi vazado o poliuretano (PU), com função de simular o tecido ósseo. Quatro extensômetros (strain gauges) foram posicionados na região vestibular, distal, lingual e mesial de cada implante, para aferir a quantidade de deformação; cada grupo foi posicionado em seu respectivo implante. Foram realizados dois testes: o teste de pré-carga com um torque de 32Ncm e o teste de carga com uma força axial estática de 300N. Cada infraestrutura foi sujeita aos dois testes, por cinco vezes. Para análise estatística dos dados, foram utilizados ANOVA (dois critérios) e o teste de Tukey (p<0,05). Os resultados mostraram que os grupos A e B tiveram menos deformação da região peri-implantar em ambos os testes, quando comparados aos grupos C e D. A estatística também mostrou que o Grupo A apresentou melhor distribuição de tensões em sua região, peri-implantar quando comparado aos outros três grupos (p<0,05). Como conclusões, este estudo mostrou que as desadaptações influem...


Nowadays implants are used in several kinds of oral rehabilitation treatments. For the osseointegration maintenance it is important that crow/implant/bone are subjected to forces which are able to withstand. Different kinds of misfit on the crown frameworks are factors that could lead to an increase of strain around the implanted bone. This study aimed to evaluate the influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial load. Frameworks made of chrome-cobalt were fabricated on UCLA abutments and divided in 4 groups: Group A (no misfit), Group B, Group C, Group D (50, 100, and 200 of unilateral angular misfit by buccal side, respectively). Each group was represented for 4 frameworks (n=4). Four implants (4.1mm/15mm) were positioned in a metallic matrix which was subsequently poured the polyurethane (PU) to simulate the bone. Four strain gauges were positioned on the buccal, distal, lingual and mesial sides of each implant to assess the amount of strain, each group was connected on its respectively implant. It was performed 2 tests: the preload test with a 32Ncm torque and the load test by applying an axial force of 300N. Each framework was subjected to the both test five times. To the statistics analysis ANOVA (2 ways) and Turkeys test were performed. The results showed that the Groups A and B presented less deformation when compared to Groups C and D. The statistics also showed that the Group A presented better distribution of strain on its peri-implant bone when compared to the other three groups (p<0,05). In conclusion this study showed that misfit had influence on the strain distribution on the peri-implant bone and that strain increased on the Groups C and D which presented higher levels of misfit.


Assuntos
Humanos , /métodos , Ligas de Cromo/química , Análise de Variância , Fenômenos Biomecânicos , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
3.
Bauru; s.n; 2013. 136 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-866663

RESUMO

Atualmente, os implantes são utilizados em diversos tipos de tratamento na reabilitação oral. Para manutenção da osseointegração, é essencial que o conjunto prótese/implante/osso seja submetido a forças às quais estejam aptos a suportar. Os diferentes tipos de desadaptações das infraestruturas das próteses sobre implantes são fatores que podem contribuir para o aumento das tensões na região peri-implantar. Este estudo teve como objetivo avaliar a influência das desadaptações angulares unilaterais na distribuição de tensões na região periimplantar de pilares tipo UCLA, no momento da pré-carga e carga axial. Infraestruturas de CoCr, confeccionadas utilizando-se pilares tipo UCLA, foram divididas em quatro grupos: Grupo A (adaptado), Grupo B, Grupo C e Grupo D (50, 100 e 200 μm de desadaptação unilateral angular por vestibular, respectivamente). Cada grupo foi representado por quatro infraestruturas (n=4). Quatro implantes (4.1mm/15mm) foram posicionados em uma matriz metálica, onde posteriormente foi vazado o poliuretano (PU), com função de simular o tecido ósseo. Quatro extensômetros (strain gauges) foram posicionados na região vestibular, distal, lingual e mesial de cada implante, para aferir a quantidade de deformação; cada grupo foi posicionado em seu respectivo implante. Foram realizados dois testes: o teste de pré-carga com um torque de 32Ncm e o teste de carga com uma força axial estática de 300N. Cada infraestrutura foi sujeita aos dois testes, por cinco vezes. Para análise estatística dos dados, foram utilizados ANOVA (dois critérios) e o teste de Tukey (p<0,05). Os resultados mostraram que os grupos A e B tiveram menos deformação da região peri-implantar em ambos os testes, quando comparados aos grupos C e D. A estatística também mostrou que o Grupo A apresentou melhor distribuição de tensões em sua região, peri-implantar quando comparado aos outros três grupos (p<0,05). Como conclusões, este estudo mostrou que as desadaptações influem...


Nowadays implants are used in several kinds of oral rehabilitation treatments. For the osseointegration maintenance it is important that crow/implant/bone are subjected to forces which are able to withstand. Different kinds of misfit on the crown frameworks are factors that could lead to an increase of strain around the implanted bone. This study aimed to evaluate the influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial load. Frameworks made of chrome-cobalt were fabricated on UCLA abutments and divided in 4 groups: Group A (no misfit), Group B, Group C, Group D (50, 100, and 200 of unilateral angular misfit by buccal side, respectively). Each group was represented for 4 frameworks (n=4). Four implants (4.1mm/15mm) were positioned in a metallic matrix which was subsequently poured the polyurethane (PU) to simulate the bone. Four strain gauges were positioned on the buccal, distal, lingual and mesial sides of each implant to assess the amount of strain, each group was connected on its respectively implant. It was performed 2 tests: the preload test with a 32Ncm torque and the load test by applying an axial force of 300N. Each framework was subjected to the both test five times. To the statistics analysis ANOVA (2 ways) and Turkeys test were performed. The results showed that the Groups A and B presented less deformation when compared to Groups C and D. The statistics also showed that the Group A presented better distribution of strain on its peri-implant bone when compared to the other three groups (p<0,05). In conclusion this study showed that misfit had influence on the strain distribution on the peri-implant bone and that strain increased on the Groups C and D which presented higher levels of misfit.


Assuntos
Humanos , /métodos , Ligas de Cromo/química , Análise de Variância , Fenômenos Biomecânicos , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
4.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-599159

RESUMO

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não indicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Poliuretanos/química , Análise de Variância , Ligas de Cromo/química , Ajuste de Prótese
5.
Bauru; s.n; 2010. 159 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-865625

RESUMO

O implante dental depende do osso de suporte para sua estabilidade e ongevidade funcional. O comportamento mecânico e a estrutura trabecular do osso afetam a interface com o implante. Tal conhecimento pode fornecer uma base para melhoramentos na função e desenho dos implantes atuais minimizando a reabsorção da crista óssea e falha na junção osso-implante. Desta forma a correta quantificação das forças que atuam sobre o sistema de implante e principalmente no osso de suporte ao qual ele está inserido é importante para o entendimento da biomecânica possibilitando que intervenções possam ser realizadas pelos profissionais visando assim à longevidade das próteses implanto-suportadas bem como dos implantes que as sustentam. Por essa razão, a proposta deste trabalho foi avaliar, com auxílio de extensômetros elétricos, se o processo laboratorial de confecção de coroas metalocerâmicas resulta em alterações das tensões no osso ao redor dos implantes. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes de hexágono externo de 3,75mm de diâmetro por 13 mm de comprimento, nos quais foram fixados intermediários multi-unit. Os corpos de prova foram confeccionados com dois tipos de ligas odontológicas - Cobalto-Cromo e Paládio-Prata - e três tipos de cilindros protéticos calcinável, usinado de Cobalto-Cromo e usinado de Ouro. As leituras de deformação foram realizadas em dois momentos: 1- após a fundição das infra-estruturas e 2 após estas infra-estruturas terem recebido cobertura cerâmica. Os testes foram realizados parafusando os corpos de prova sobre os intermediários utilizando-se para isto um dispositivo eletrônico de torque com força máxima de 10 Ncm. Os resultados mostraram que, após a aplicação da cobertura cerâmica, ocorreu piora da condição de assentamento aos intermediários. O mesmo não foi detectado quando se avaliou a deformação do osso simulado, já que os valores de deformação não ndicaram...


The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate quantification of forces that act upon the implant system and mainly on the supporting bone is important for understanding the biomechanics, allowing the intervention by professionals with the purpose of achieving the longevity of implant-supported prostheses. Therefore, this work aims at evaluating, with the aid of strain gauges, whether the laboratorial process of metal ceramic crown fabrication results in changes of the tensions around the implants. A U-shaped polyurethane model simulating the mandibular bone with two 3.75-mm diameter and 13-mm length external hexagon implants were used with fixed multi-unit abutments. Specimens were prepared with two types of dental alloys - cobalt-chromium and silver-palladium - and three types of prosthetic cylinder castable plastic, prefabricated in cobalt-chromium or gold. The deformation readings were performed in two moments: 1- after framework casting and 2- after ceramic layering of the framework. The tests were performed with the framework screwed onto the abutments at 10Ncm using an electronic torque device. The results showed that the ceramic layering worsened the fit between the crowns and the abutments. The same was not detected when bone deformation was evaluated since the values were not statistically different.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Poliuretanos/química , Análise de Variância , Ligas de Cromo/química , Ajuste de Prótese