Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
The Journal of Korean Knee Society ; : 99-103, 2012.
Artigo em Inglês | WPRIM | ID: wpr-759054

RESUMO

PURPOSE: To compare the extramedullary femoral alignment guide system with the conventional intramedullary alignment guide system for bleeding and transfusion rate after total knee arthroplasty (TKA). MATERIALS AND METHODS: Forty-nine female TKA patients were randomized into two groups: intramedullary (IM) group vs. extramedullary (EM) group. Drained volume of blood, hemoglobin concentration, hemoglobin drop, and transfusion rate were compared between the two groups. Wound problems, bleeding-related problems and thromboembolic complications were collected. RESULTS: The mean drained volume via vacuum drainage was less in the EM group than that in the IM group (482.9 mL vs. 266.8 mL, p=0.001). Hemoglobin at 5 days after surgery was higher in the EM group (9.3 g/dL vs. 9.9 g/dL, p=0.002) than that in the IM group. The drop in hemoglobin after 5 days was smaller in the EM group (3.5 g/dL vs. 2.9 g/dL, p=0.003) than that in the IM group. The EM group had a lower prevalence of allogeneic transfusion (45.0% vs. 20.5%, p=0.026) than that in the IM group. No significant complications developed in either group. CONCLUSIONS: The results suggest that the extramedullary femoral alignment guide technique is an advantageous method that can reduce the drained volume of blood and the allogeneic transfusion rate.


Assuntos
Feminino , Humanos , Artroplastia , Drenagem , Hemoglobinas , Hemorragia , Joelho , Prevalência , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA