Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Dental press j. orthod. (Impr.) ; 25(4): 59-67, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1133682

RESUMO

ABSTRACT Objective: To compare the effectiveness of the pretreatment with sandblasting and deproteinization with NaOCl on bond strength (SBS), in situ conversion degree (CD) of brackets in fluorotic enamel, and enamel etching pattern. Methods: A total of 90 non-carious maxillary premolars were used. The teeth were then assigned to six experimental groups according to: enamel surface (sound and fluorotic enamel); surface treatment (Regular etch with 37% phosphoric acid [RE]; 5.2% sodium hypochlorite + phosphoric acid [NaOCl + RE]; sandblasting + phosphoric acid [sandblasting + RE]). After storage in distilled water (37°C/24h), the specimens were tested at 1 mm/min until failure (SBS). Enamel-resin cement interfaces were evaluated for CD using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a scanning electron microscope. Data from SBS and in situ CD values were analyzed using ANOVA two-away and Tukey test (α=0.05). The enamel etching pattern was evaluated only qualitatively. Results: For sound enamel, RE showed the highest SBS values, when compared to NaOCl + RE and Sandblasting + RE groups (p< 0.01). Regarding CD, only NaOCl + RE significantly compromised the mean DC, in comparison with other groups (p= 0.002). For fluorotic enamel, the Sandblasting + RE group significantly increased the mean SBS values, in comparison with RE group (p= 0.01) and no significant change was observed for CD (p> 0.52). Conclusions: The application of NaOCl or sandblasting associated to phosphoric acid improved the SBS of the brackets in fluorotic enamel without compromising the CD of the resin cement, with improving of enamel interprismatic conditioning.


RESUMO Objetivo: Comparar a efetividade do pré-tratamento com jateamento e desproteinização com NaOCl na resistência de união (SBS), grau de conversão in situ (GC) dos braquetes metálicos ao esmalte fluorótico e o padrão de condicionamento do esmalte. Métodos: Foi utilizado um total de 90 pré-molares superiores livres de cárie. Os dentes foram divididos em seis grupos experimentais, de acordo com: superfície do esmalte (Esmalte Sadio e Fluorótico); tratamento de superfície (Condicionamento com ácido fosfórico a 37% [ER]; Hipoclorito de sódio a 5,2% + ácido fosfórico [NaOCl + ER]; e jateamento + ácido fosfórico [Jateamento + ER]). Após armazenamento em água destilada (37oC/24 h), os espécimes foram testados a 1 mm/min até a falha (SBS). As interfaces esmalte-cimento foram avaliadas para GC usando espectroscopia micro-Raman. O padrão do condicionamento do esmalte foi avaliado sob microscopia eletrônica de varredura. Os dados da SBS e GC foram analisados utilizando ANOVA dois fatores e teste de Tukey (α= 0,05). O padrão de condicionamento do esmalte foi avaliado apenas qualitativamente. Resultados: Para o esmalte sadio, o ER apresentou os maiores valores de SBS, quando comparado aos grupos NaOCl + ER e Jateamento + ER (p< 0,01). Em relação ao GC, apenas a média do grupo NaOCl + ER foi comprometida significativamente em comparação aos outros grupos (p= 0,002). Para o esmalte fluorótico, Jateamento + ER aumentou significativamente a média dos valores de SBS, em comparação com o grupo ER (p= 0,01) e nenhuma mudança significativa foi observada no GC (p> 0,52). Conclusões: A aplicação de NaOCl ou jateamento associado ao ácido fosfórico melhorou a SBS dos braquetes no esmalte fluorótico sem comprometer o GC do cimento resinoso, com a melhoria do condicionamento interprismático do esmalte.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Ácidos Fosfóricos , Propriedades de Superfície , Condicionamento Ácido do Dente , Teste de Materiais , Cimentos de Resina , Cimentos Dentários , Esmalte Dentário , Resistência ao Cisalhamento
2.
Braz. dent. sci ; 23(2): 1-6, 2020. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1096283

RESUMO

Objective: Degree of Conversion (DC) of ResinBased composites (RBCs) is a concern and is affected by different factors. This study was conducted to evaluate the effect of different thicknesses and storage times on DC of bulk-fill and universal RBCs using the FTIR method. Material and Methods: For each of dental composite (Tetric N- Ceram Bulk Fill and Tetric N Ceram), 28 samples were prepared (14 samples with 2 mm height and 14 samples with 4 mm height). One and seven days (1d and 7d) after storage in an incubator at 37 ˚C, DC was measured and recorded using a FTIR device. Data were analyzed using t-test and ThreeWay ANOVA and Tukey Post-Hoc Test. P < 0.05 was considered statistically significant. Results: DC of Bulk-fill composite is greater than universal composite. DC at 2 mm thickness is more than 4 mm. Unlike universal composite, 7d DC of Bulkfill composite is greater than 1d. Of course, none of these differences are statistically significant (P-value > 0.05). Conclusion: Considering the limitation of this study, since no difference was found between DC of 1d and 7d, 1d DC is sufficient for clinical procedures, such as polishing, and the laboratory tests. (AU)


Objetivo: O grau de conversão (DC) de compósitos à base de resina (RBCs) é um assunto que merece cuidado e é afetado por diferentes fatores. Este estudo foi conduzido para avaliar o efeito de diferentes espessuras e tempos de armazenamento no DC de compósitos Bulk-fill e compósitos universais usando o método FTIR. Material e Métodos: Para cada compósito dentário (Tetric N-Ceram Bulk Fill e Tetric N Ceram), foram preparadas 28 amostras (14 amostras com 2 mm de altura e 14 amostras com 4 mm de altura). Um e sete dias (1d e 7d) após o armazenamento em uma incubadora a 37 ° C, o DC foi mensurado e registrado usando um dispositivo FTIR. Os dados foram analisados por meio do teste t, ANOVA três fatores e teste PostHoc de Tukey. P 0,05). Conclusão: Considerando a limitação deste estudo, uma vez que não foi encontrada diferença entre as DC de 1d e 7d, a 1d DC é suficiente para procedimentos clínicos, como polimento e testes laboratoriais. (AU)


Assuntos
Espectroscopia de Infravermelho com Transformada de Fourier , Resinas Compostas
3.
Braz. dent. sci ; 23(2): 1-10, 2020. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1096329

RESUMO

Objectives: This study aims to evaluate the degree of conversion (DC) and microlekage scores of three different composite resins polymerized with a LED curing device in standard and extra-power mode. Material and Methods: One bulk-fill (Tetric EvoCeram Bulk-Fill ­ TECBF) and two conventional composite materials (Clearfil Majesty Posterior ­ CMP and Tetric EvoCeram ­ TEC) were evaluated. A total of 30 specimens were prepared for six groups (N = 5). These groups were polymerized with a LED curing device as follows: TECBF-6: 3200mW/cm2 for six seconds, TECBF-20: 1000mW/cm2 for 20 seconds, CMP-6: 3200mW/cm2 for six seconds, CMP-20: 1000mW/cm2 for 20 seconds, TEC-6: 3200mW/cm2 for six seconds, TEC - 20: 1000 mW/cm2 for 20 seconds. After 24 hours of water storage, DC was measured by Raman spectroscopy. Microleakage scores of the six groups were bonded to various adhesive systems (Clearfil SE Bond or Adhese Bond Universal) were also evaluated at Class II box cavities (N = 10). Results: While the highest DC was found at the top (TECBF-20= 79.92% and TECBF-6= 79.02%) and bottom surfaces (TECBF-20 = 68.94% and TECBF-6= 71.04%) for TECBF groups, TEC groups (TEC-20top = 59.06%, TEC-6top=49.66%, TEC-20bottom = 43.72% and TEC-6bottom= 40.68%) showed the lowest DC for the both surfaces (p < 0.05). Polymerization of materials in standard or extra-power mode was similar to DC (p > 0.05). Microleakage scores were found to be similar (p > 0.05). Conclusion: According to the results of the study, different power densities of LED curing light did not affect the DC of composite resins and microleakage values of restorations at small Class II cavities (AU)


Objetivo: este estudo tem como objetivo avaliar os graus de conversão (DC) e microinfiltração de três diferentes resinas compostas polimerizáveis com um dispositivo de luz por LED nos modos padrão e no modo de alta-potência. Material e métodos: uma resina bulk-fill (Tetric EvoCeram Bulk-Fill - TECBF) e dois materiais resinosos convencionais (Clearfil Majesty Posterior - CMP e Tetric EvoCeram - TEC) foram avaliados. Um total de 30 espécimes foram preparados e divididos em seis grupos (N = 5). Esses grupos foram polimerizados com um dispositivo de luz de LED da seguinte forma: TECBF-6: 3200mW / cm2 por seis segundos, TECBF-20: 1000mW / cm2 por 20 segundos, CMP-6: 3200mW / cm2 por seis segundos, CMP20: 1000mW / cm2 por 20 segundos, TEC-6: 3200mW / cm2 por seis segundos, TEC - 20: 1000 mW / cm2 por 20 segundos. Após 24 horas de armazenamento em água, a DC foi medida por espectroscopia Raman. Os escores de microinfiltração dos seis grupos dos vários sistemas adesivos (Clearfil SE Bond ou Adhese Bond Universal) também foram avaliados nas cavidades Classe II (N = 10). Resultados: embora a maior CD tenha sido encontrada nas partes superior (TECBF-20 = 79,92% e TECBF-6 = 79,02%) e inferiores (TECBF-20 = 68,94% e TECBF-6 = 71,04%) para grupos TECBF, os grupos TEC (TEC-20top = 59,06%, TEC-6top = 49,66%, TEC-20bottom = 43,72% e TEC-6bottom = 40,68%) apresentaram as menores CD para as ambas as partes (p < 0,05). A polimerização de materiais no modo padrão ou alta-potência foi semelhante à DC (p > 0,05). Os escores de microinfiltração foram semelhantes (p > 0,05). Conclusão: de acordo com os resultados do estudo, diferentes densidades de potência da luz de LED não afetaram as CD das resinas compostas e os valores de microinfiltração das restaurações em pequenas cavidades da Classe II. (AU)


Assuntos
Análise Espectral Raman , Adesivos Dentinários , Resinas Compostas , Infiltração Dentária
4.
Bauru; s.n; 2017. 97 p. tab, graf, ilus.
Tese em Português | LILACS, BBO | ID: biblio-880081

RESUMO

Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos.(AU)


The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.(AU)


Assuntos
Humanos , Bis-Fenol A-Glicidil Metacrilato/química , Colagem Dentária/métodos , Cimentos Dentários/química , Dentina/efeitos dos fármacos , Saliva/química , Análise de Variância , Dentina/química , Teste de Materiais , Microscopia Confocal , Polimerização , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
5.
Bauru; s.n; 2015. 91 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-794234

RESUMO

O objetivo desta pesquisa foi avaliar a transmitância de diferentes tipos e cores de cerâmicas e seus efeitos no grau de conversão (GC) de dois tipos de cimentos resinosos com modo de polimerização dual. Foram confeccionadas 60 pastilhas com a cerâmica IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) e divididas em 3 grupos: LT, MO e Z, com 20 pastilhas cada um. Nos grupos LT e MO, as pastilhas foram confeccionadas com a cerâmica de dissilicato de lítio de baixa translucidez (LT - low transluscency) e de média opacidade (MO - medium opacity), respectivamente. No grupo Z, as pastilhas foram confeccionadas em zircônia. Cada grupo foi subdividido em 5 subgrupos (n=4), de acordo com a cor da cerâmica: A2; A3,5; B2; C2; D3. No grupo LT, as pastilhas foram prensadas nas cores anteriormente citadas e, nos grupos MO e Z, as pastilhas foram, inicialmente, confeccionadas para simular infraestruturas e, posteriormente, receberem aplicação de cerâmica de revestimento IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) nas mesmas cores. O espectrofotômetro UV 1800 Shimadzu foi utilizado para medir a transmitância de cada espécime de cerâmica (2,0 mm de espessura). Para medir o GC, espécimes dos cimentos resinosos Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) e Rely X U200 (3M ESPE, St. Paul, MN, USA), com espessura de 100 μm, foram fotopolimerizados sob os discos de cerâmica por 40 s. Espécimes dos cimentos fotoativados sem a interposição da cerâmica foram usados como grupo controle. A polimerização dos cimentos foi avaliada através da espectrometria no infravermelho com transformada de Fourier (FTIR) empregando o método de reflexão atenuada total (ATR) imediatamente após a fotopolimerização. Os resultados foram submetidos aos testes ANOVA a 1 critério e Teste de Tukey (α=5%). Os valores de transmitância foram inferiores a 1%, sendo que as do grupo LT apresentaram, em geral, os maiores valores de transmitância, seguidos dos grupos MO e Z. O GC do cimento...


The aim of the present study was to evaluate the transmittance of different ceramic types and shades and their effects on the degree of conversion (DC) of two dual-cure resin cements. Sixty discs were fabricated with IPS e.max ceramic (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into three groups (n= 20 in each group): LT, MO and Z. For LT and MO groups discs were fabricated with low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, respectively. Discs from Z group were manufactured of zirconia. Each group was divided into five subgroups (n = 4), according to the ceramic shade: A2; A3,5; B2; C2; D3. In the LT group, specimens were heat-pressed in shades cited above and in the MO and Z groups, the discs were initially fabricated as core materials and then veneered with veneer ceramic (IPS e.max Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) in the same shades. A spectrophotometer UV-1800 Shimadzu was used to determine the transmittance percentage of each ceramic specimen (2.0-mm-thick). For DC measurements, the resin cements (Variolink II - Ivoclar Vivadent, Schaan, Liechtenstein and Rely X U200 - 3M ESPE, St. Paul, MN, USA) specimens (thickness: 100 μm) were photocured under the ceramic discs (2.0-mm-thick) for 40 s. Specimens photocured without the ceramics discs were used as control group. ATR/FTIR spectrometry was used to evaluated the extent of polymerization for all cement specimens immediately after photocuring. The results were submitted to one-way ANOVA and Tukey test (α=5%). The transmittance percentage was less than 1% and the LT group had the highest transmittance values, followed by MO and Z groups. The %DC of Variolink II cement was not influenced by the ceramic disc interposition. For Rely X U200 cement, the interposition of some ceramics types/shades (LT A3,5, MO A2, MO A3,5 and Z A3,5) significantly decreased the %DC compared to control group. It was concluded that the transmittance values and %DC...


Assuntos
Humanos , Autocura de Resinas Dentárias/métodos , Cor , Cerâmica/química , Cimentos de Resina/química , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
6.
Bauru; s.n; 2015. 91 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-867436

RESUMO

O objetivo desta pesquisa foi avaliar a transmitância de diferentes tipos e cores de cerâmicas e seus efeitos no grau de conversão (GC) de dois tipos de cimentos resinosos com modo de polimerização dual. Foram confeccionadas 60 pastilhas com a cerâmica IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) e divididas em 3 grupos: LT, MO e Z, com 20 pastilhas cada um. Nos grupos LT e MO, as pastilhas foram confeccionadas com a cerâmica de dissilicato de lítio de baixa translucidez (LT - low transluscency) e de média opacidade (MO - medium opacity), respectivamente. No grupo Z, as pastilhas foram confeccionadas em zircônia. Cada grupo foi subdividido em 5 subgrupos (n=4), de acordo com a cor da cerâmica: A2; A3,5; B2; C2; D3. No grupo LT, as pastilhas foram prensadas nas cores anteriormente citadas e, nos grupos MO e Z, as pastilhas foram, inicialmente, confeccionadas para simular infraestruturas e, posteriormente, receberem aplicação de cerâmica de revestimento IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) nas mesmas cores. O espectrofotômetro UV 1800 Shimadzu foi utilizado para medir a transmitância de cada espécime de cerâmica (2,0 mm de espessura). Para medir o GC, espécimes dos cimentos resinosos Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) e Rely X U200 (3M ESPE, St. Paul, MN, USA), com espessura de 100 μm, foram fotopolimerizados sob os discos de cerâmica por 40 s. Espécimes dos cimentos fotoativados sem a interposição da cerâmica foram usados como grupo controle. A polimerização dos cimentos foi avaliada através da espectrometria no infravermelho com transformada de Fourier (FTIR) empregando o método de reflexão atenuada total (ATR) imediatamente após a fotopolimerização. Os resultados foram submetidos aos testes ANOVA a 1 critério e Teste de Tukey (α=5%). Os valores de transmitância foram inferiores a 1%, sendo que as do grupo LT apresentaram, em geral, os maiores valores de transmitância, seguidos dos grupos MO e Z. O GC do cimento...


The aim of the present study was to evaluate the transmittance of different ceramic types and shades and their effects on the degree of conversion (DC) of two dual-cure resin cements. Sixty discs were fabricated with IPS e.max ceramic (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into three groups (n= 20 in each group): LT, MO and Z. For LT and MO groups discs were fabricated with low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, respectively. Discs from Z group were manufactured of zirconia. Each group was divided into five subgroups (n = 4), according to the ceramic shade: A2; A3,5; B2; C2; D3. In the LT group, specimens were heat-pressed in shades cited above and in the MO and Z groups, the discs were initially fabricated as core materials and then veneered with veneer ceramic (IPS e.max Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) in the same shades. A spectrophotometer UV-1800 Shimadzu was used to determine the transmittance percentage of each ceramic specimen (2.0-mm-thick). For DC measurements, the resin cements (Variolink II - Ivoclar Vivadent, Schaan, Liechtenstein and Rely X U200 - 3M ESPE, St. Paul, MN, USA) specimens (thickness: 100 μm) were photocured under the ceramic discs (2.0-mm-thick) for 40 s. Specimens photocured without the ceramics discs were used as control group. ATR/FTIR spectrometry was used to evaluated the extent of polymerization for all cement specimens immediately after photocuring. The results were submitted to one-way ANOVA and Tukey test (α=5%). The transmittance percentage was less than 1% and the LT group had the highest transmittance values, followed by MO and Z groups. The %DC of Variolink II cement was not influenced by the ceramic disc interposition. For Rely X U200 cement, the interposition of some ceramics types/shades (LT A3,5, MO A2, MO A3,5 and Z A3,5) significantly decreased the %DC compared to control group. It was concluded that the transmittance values and %DC...


Assuntos
Autocura de Resinas Dentárias/métodos , Cor , Cerâmica/química , Cimentos de Resina/química , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
7.
Braz. dent. sci ; 17(3): 60-66, 2014.
Artigo em Inglês | LILACS, BBO | ID: lil-743034

RESUMO

The longevity of resin depends on its binding between the margin of restorations and the polymer, and one factor that influences this aspect is the shrinkage stress. Thus, the working group presents the following systematic review thatverifies the influence of composite resin composition on shrinkage stress. The following electronic databases were searched: MEDLINE (via Ovid and PubMed - 2004 to January 2014), with the keywords: shrinkage stress, degree of conversion, resin composite. For shrinkage stress,, the best results were found when the BISGMA monomer was used and for the inorganic composition, an inverse relationship was observed: the increased inorganic filler content decreases shrinkage stress.


A longevidade de resina depende da sua ligação entre a margem de restaurações e o polímero, e um fator que influencia a este aspecto, é a tensão de contração. Assim, o grupo de trabalho faz a seguinte análise sistemática para verificar a influência da composição das resinas composta na tensão de contração. As seguintes bases de dados eletrônicas foram pesquisadas: MEDLINE (via PubMed e Ovídio - de 2004 a janeiro de 2014), com as palavras-chave: estresse de contração, grau de conversão, resina composta. Para tensão de contração, os melhores resultados foram encontrados quando o monômero BISGMA foi utilizada e para a composição inorgânica, uma relação inversa foi observada: o aumento do teor de carga inorgânica diminui estresse de contração.


Assuntos
Resinas Compostas , Análise do Estresse Dentário
8.
Rio de Janeiro; s.n; 2013. 95 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-867233

RESUMO

A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFil®SDR™ (Dentsply) (SDR), resina flow Filtek™Z350Flow (3M/ESPE) (Z350F) e resina composta Filtek™P90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas ...


The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil ® SDR ™ (Dentsply) low shrinkage resin (SDR), Filtek ™ Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek ™ P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal ...


Assuntos
Humanos , Resinas Compostas , Adaptação Marginal Dentária , Dentística Operatória , Fenômenos Químicos , Análise de Variância , Brasil , Módulo de Elasticidade , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
9.
Rio de Janeiro; s.n; 2013. 95 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-755459

RESUMO

A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFil®SDR™ (Dentsply) (SDR), resina flow Filtek™Z350Flow (3M/ESPE) (Z350F) e resina composta Filtek™P90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas...


The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil ® SDR ™ (Dentsply) low shrinkage resin (SDR), Filtek ™ Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek ™ P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal...


Assuntos
Humanos , Resinas Compostas , Adaptação Marginal Dentária , Dentística Operatória , Fenômenos Químicos , Análise de Variância , Brasil , Módulo de Elasticidade , Teste de Materiais , Espectroscopia de Infravermelho com Transformada de Fourier
10.
Braz. dent. sci ; 16(1): 18-26, 2013. tab
Artigo em Inglês | LILACS, BBO | ID: lil-698273

RESUMO

Objectives: The aim of this study was to carry out a review on the methods of direct detection of theconversion degree of composite resins. Materials & methods: The authors searched the Cochrane Library,Embase, PubMed, and the Web of Science (ISI) for papers dated from January 1991 to November 2011.The search was complemented by manual searches of the reference lists from each identified relevant paper.The main search terms were: “degree of conversion”, “monomers”, "polymers”, “composite”, “pre-gel”,“post-gel”, “residual monomers” and “double bond”. The inclusion criteria were studies that evaluatedconsolidated methods in the literature to directly evaluate the degree of conversion. Excluded studieswere those considered to be unrelated to the question addressed, such as mechanical and physicalproperties and also monomers from adhesive systems and compomers. The selected papers were assignedto a score (A, B or C), according to the predetermined criteria. Results: A total of 45 papers were selectedand 15 papers were included in the critical appraisal. Two articles were labeled as grade A, nine articleswere labeled as grade B, and four articles were labeled as grade C. Conclusions: According to thedefinitions of evidence levels, the current article study showed a strong evidence of review. Clinicalsignificance: The degree of conversion predicts the quality of polymers because the higher degree ofconversion, the higher strength of the resin matrix.


Objetivos: O objetivo deste estudo foi revisar os métodos de detecção direta do grau de conversão de resinas compostas. Material e Métodos: Os autores pesquisaram artigos publicados no período de Janeiro de 1991 a novembro de 2011, nas bases de dados Cochrane Library, Embase, PubMed e Web of Science (ISI). A pesquisa foi complementada por pesquisa manual das listas de referências de cada artigo identificado como relevante sobre o tema. Os principais termos pesquisados foram: “grau de conversão”, “monômeros”, “polímeros”, “compósito”, “pré-gel”, “pós-gel”, “monômeros residuais” e“dupla ligação”. Os critérios de inclusão foram estudos que avaliaram diretamente o grau de conversão utilizando métodos consolidados na literatura. Os estudos excluídos foram aqueles considerados não relacionados à questão abordada, como estudos sobre propriedades físicas e mecânicas e também sobre monômeros de sistemas de união e compômeros. Os artigos selecionados foram divididos na classificação A, B ou C, de acordo com critérios pré-determinados. Resultados: Quarenta e cinco artigos foram selecionados e quinze artigos foram incluídos na avaliação. Dois artigos foram classificados como grade A, nove artigos como grade B e quatro artigos como grade C. Conclusões: De acordo com as definições dos níveis de evidência, o presente estudo apresentou forte evidência de revisão. Significância Clínica: O grau de conversão prediz a qualidade dos polímeros formados, uma vez que quanto maior o grau de conversão, mais resistente é a matriz resinosa.


Assuntos
Abrasão Dentária
11.
São Paulo; s.n; 2013. 84 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO | ID: lil-715012

RESUMO

Objetivo: Analisar a influência da matriz orgânica, do conteúdo inorgânico e do tratamento térmico (TT) sobre diferentes propriedades de compósitos experimentais, tais como o grau de conversão (GC), tenacidade à fratura (KIC), resistência à flexão (RF) e módulo de elasticidade (ME). Métodos: Para o experimento foram analisadas seis formulações de compósitos experimentais com proporções molares de Bis-GMA:TEGDMA de 5:5 e 7:3, a carga utilizada foi o vidro de bário, nas concentrações de 30, 50 e 70% em peso, e os fotoiniciadores a amina e canforoquinona. O GC foi analisado através da espectroscopia no infra-vermelho (FTIR) (n=5). A KlC foi avaliada pelo método single-edge notched beam (SENB). As imagens das superfícies de fratura foram capturadas por um estereomicroscópio e a KlC calculada (n=10). A análise da RF e ME foi realizada através do teste dos três pontos (n=10). Para todos os fatores de variação estudados, metade dos espécimes imediatamente após à confecção receberam TT em estufa convencional, a 170º C por 10 minutos e a outra metade não. Após 24 horas, as amostras foram destinadas de acordo com os ensaios realizados...


Objective: To analyze the influence of organic matrix, the inorganic content and thermic treatment (TT) on different properties of experimental composites, such as the degree of conversion (DC), fracture toughness (KIC), flexural strength (FS) and elastic modulus (EM). Methods: This experiment analyzed six formulations of experimental composites with 5:5 and 7:3 molar proportions of Bis-GMA: TEGDMA. The load used was barium glass at concentrations of 30, 50 and 70% by weight and the photoinitiators, camphorquinone and amine. GC was analyzed by infrared spectroscopy (FTIR) (n=5). The KIC was evaluated by a "single-edge notched beam" (SENB). The images of the fracture surfaces were captured by a stereomicroscope and KIC calculated (n=10). The analysis FS and EM were performed by testing three points (n=10). For all the variation factors studied, half of the specimens immediately after the preparation received TT in conventional oven at 170º C for 10 minutes and the other half not. After 24 hours, the samples were designed according to the tests. Data were analyzed using ANOVA/Tukey the degree of conversion, fracture toughness and flexural strength, and Kruskal-Wallis test for the elastic modulus (=5%). Results: Analysis of GC (%) statistical significance was observed for the three variation factors analyzed individually (monomer, filler and TT), as well as for the interaction monomer x TT (p <0.001). For KIC and FS, significant changes were observed only in the three variation factors (monomer, filler and TT) analyzed individually (p<0.001). For EM, the individual factors (monomer, filler and TT) TT x filler interaction showed statistical significance (p <0.001), as well as the monomer x filler interaction (p = 0.001). Conclusions: The organic matrix and inorganic content of experimental composites influenced the GC, KIC, FS and EM, and the TT caused improvements in the properties studied.


Assuntos
Materiais Dentários/análise , Resinas Compostas/análise , Resistência à Tração , Tratamento Térmico/métodos
12.
Bauru; s.n; 2012. 137 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-673684

RESUMO

É crescente a aplicação dos cimentos à base de resina em próteses em cerâmica por exibirem propriedades estéticas e biomecânicas superiores aos cimentos convencionais. O presente estudo teve por objetivo avaliar o grau de conversão (GC) de quatro cimentos resinosos, sendo um com modo de polimerização físico (ChoiceTM 2/Bisco Inc), 2 com modo de polimerização dual (DuolinkTM/ Bisco Inc; VariolinkII®/Ivoclar-Vivadent) e um cimento com modo de polimerização químico (C&BTM/Bisco Inc), empregados na cimentação de coroas confeccionadas em cerâmica. Foram utilizados 42 pré-molares humanos que foram preparados para receber coroas totais confeccionadas com 2 sistemas cerâmicos: cerâmica de dissilicato de lítio (IPS e.MaxPress/Ivoclar-Vivadent®) e cerâmica de óxido de Zircônia estabilizada por Itrio (IPS e.maxZirCAD/Ivoclar-Vivadent®) para confecção dos copings, tendo uma cerâmica a base de fluorapatita como cobertura (IPS e.maxZirPresss/Ivoclar-Vivadent). Para a cimentação os dentes/coroas/cimento foram subdivididos aleatoriamente e, a foto ativação dos cimentos dual e físico, foi realizada com dois protocolos: foto-ativação nas faces vestibular, oclusal e lingual, com o tempo de exposição de 20s sequencialmente e foto-ativação somente por oclusal pelo tempo de 60s. O cimento químico foi mantido sem aturdimento por 15 minutos. Após a cimentação, os espécimes foram armazenados em água deionizada em estufa com temperatura de ±36oC e seccionados transversalmente após 7 dias em 3 regiões: cervical, no centro da coroa e 2mm aquém da face oclusal. O grau de conversão foi determinado pela técnica da espectroscopia Micro-Raman ao longo da linha de cimento nas face vestibular, mesial, lingual e distal...


There is a growing application of resin-based cements in ceramic prostheses for displaying aesthetic and biomechanical properties superior to conventional cements. The present study aimed to evaluate the degree conversion (DC) of four resin cements, one with physical curing mode (ChoiceTM 2/Bisco Inc), two dualcuring mode (DuolinkTM / Bisco Inc; VariolinkII® / Ivoclar-Vivadent) and one chemical curing mode (C&BTM / Bisco Inc) employed in the cementation of crowns made of ceramic. We used 42 human premolars were prepared to receive full crowns made with two ceramic systems: lithium disilicate ceramic (IPS eMaxPress/Ivoclar- Vivadent®) and Yttrium oxide stabilized zirconia (IPS e.maxZirCAD / Ivoclar - Vivadent®) for the fabrication of copings, with a ceramic veneer as fluorapatite based (IPS e.maxZirPresss / Ivoclar-Vivadent). For cementation, teeth/crowns/cement were randomly divided, and the photo activation of dual cements and physical, was performed with two protocols: photo-activation in the buccal, occlusal and lingual, with an exposure time of 20s in each face and photo-activation only by occlusal for 60s. The cement chemical was maintained for 15 minutes without stunning. After cementation, specimens were stored in deionized water in an oven at a temperature of 37°C and sectioned after 7 days in three regions : cervical, in the center of the crown and 2 mm below the occlusal surface. The degree of conversion was determined along the cement line in the buccal, mesial, lingual and distal by micro- Raman spectroscopy...


Assuntos
Humanos , Autocura de Resinas Dentárias/métodos , Cerâmica/química , Cimentos de Resina/química , Cura Luminosa de Adesivos Dentários/métodos , Análise Espectral Raman , Análise de Variância , Coroas , Teste de Materiais , Reprodutibilidade dos Testes , Fatores de Tempo
13.
Bauru; s.n; 2012. 137 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-866212

RESUMO

É crescente a aplicação dos cimentos à base de resina em próteses em cerâmica por exibirem propriedades estéticas e biomecânicas superiores aos cimentos convencionais. O presente estudo teve por objetivo avaliar o grau de conversão (GC) de quatro cimentos resinosos, sendo um com modo de polimerização físico (ChoiceTM 2/Bisco Inc), 2 com modo de polimerização dual (DuolinkTM/ Bisco Inc; VariolinkII®/Ivoclar-Vivadent) e um cimento com modo de polimerização químico (C&BTM/Bisco Inc), empregados na cimentação de coroas confeccionadas em cerâmica. Foram utilizados 42 pré-molares humanos que foram preparados para receber coroas totais confeccionadas com 2 sistemas cerâmicos: cerâmica de dissilicato de lítio (IPS e.MaxPress/Ivoclar-Vivadent®) e cerâmica de óxido de Zircônia estabilizada por Itrio (IPS e.maxZirCAD/Ivoclar-Vivadent®) para confecção dos copings, tendo uma cerâmica a base de fluorapatita como cobertura (IPS e.maxZirPresss/Ivoclar-Vivadent). Para a cimentação os dentes/coroas/cimento foram subdivididos aleatoriamente e, a foto ativação dos cimentos dual e físico, foi realizada com dois protocolos: foto-ativação nas faces vestibular, oclusal e lingual, com o tempo de exposição de 20s sequencialmente e foto-ativação somente por oclusal pelo tempo de 60s. O cimento químico foi mantido sem aturdimento por 15 minutos. Após a cimentação, os espécimes foram armazenados em água deionizada em estufa com temperatura de ±36oC e seccionados transversalmente após 7 dias em 3 regiões: cervical, no centro da coroa e 2mm aquém da face oclusal. O grau de conversão foi determinado pela técnica da espectroscopia Micro-Raman ao longo da linha de cimento nas face vestibular, mesial, lingual e distal...


There is a growing application of resin-based cements in ceramic prostheses for displaying aesthetic and biomechanical properties superior to conventional cements. The present study aimed to evaluate the degree conversion (DC) of four resin cements, one with physical curing mode (ChoiceTM 2/Bisco Inc), two dualcuring mode (DuolinkTM / Bisco Inc; VariolinkII® / Ivoclar-Vivadent) and one chemical curing mode (C&BTM / Bisco Inc) employed in the cementation of crowns made of ceramic. We used 42 human premolars were prepared to receive full crowns made with two ceramic systems: lithium disilicate ceramic (IPS eMaxPress/Ivoclar- Vivadent®) and Yttrium oxide stabilized zirconia (IPS e.maxZirCAD / Ivoclar - Vivadent®) for the fabrication of copings, with a ceramic veneer as fluorapatite based (IPS e.maxZirPresss / Ivoclar-Vivadent). For cementation, teeth/crowns/cement were randomly divided, and the photo activation of dual cements and physical, was performed with two protocols: photo-activation in the buccal, occlusal and lingual, with an exposure time of 20s in each face and photo-activation only by occlusal for 60s. The cement chemical was maintained for 15 minutes without stunning. After cementation, specimens were stored in deionized water in an oven at a temperature of 37°C and sectioned after 7 days in three regions : cervical, in the center of the crown and 2 mm below the occlusal surface. The degree of conversion was determined along the cement line in the buccal, mesial, lingual and distal by micro- Raman spectroscopy...


Assuntos
Humanos , Autocura de Resinas Dentárias/métodos , Cerâmica/química , Cimentos de Resina/química , Cura Luminosa de Adesivos Dentários/métodos , Análise Espectral Raman , Análise de Variância , Coroas , Teste de Materiais , Reprodutibilidade dos Testes , Fatores de Tempo
14.
Full dent. sci ; 2(6): 213-218, 20110816.
Artigo em Português | LILACS, BBO | ID: biblio-850838

RESUMO

Grau de Conversão (GC) em dentística restauradora se define como o método para medir da taxa de conversão de resinas compostas. Devido aos diferentes tipos de polimerização bem como de composições das resinas esta propriedade é imperceptível ao profissional clínico e somente torna-se perceptível através de instrumentos laboratoriais. Foi medido o Grau de Conversão para este estudo de 3 marcas comerciais de resinas compostas (Filtek Z250, Fill Magic e Opallis) para a restauração direta, através do Infravermelho por Transformadas de Fourier (FTIR) BXll – Perkin Elmer com absorbância nos números de onda 1297 ± 10 cm-1, 1319 ± 10 cm-1 e 1637 ± 10 cm-1 em função da potência dos aparelhos fotoativadores Bisco (300 mW/cm2 e 600 mW/cm2) e DMC Ultra Blue IS (350 mW/cm2). Uma amostra de 10 mg ± 2 mg foi colocada no ZnSe ATR ( Miracle ATR, Perkin Elmer) e medido antes da polimerização (T0) com os parâmetros : 600 – 4000 cm-1 e 32 scans. Após esta leitura inicial a amostra foi polimerizada por 20s, 40s, 60s e 80s com o aparelho fotoativador na intensidade pretendida e ajustada. As resinas Filtek Z250, FillMagic e Opallis apresentaram um grau de conversão semelhantes entre si e satisfatório com o fotoativador Bisco na duas potências (300 e 600 mW) testadas. Com a fotoativador DMC as resinas Opallis e Fill Magic não atingiram o objetivo de 52 % de conversão. A combinação Fotoativador, Resina e Tempo de Polimerização ideal é de imensa importância para o sucesso da restauração


The Degree of Conversion (DC) in restorative dentistry is defined as a method to measure the rate of conversion of composites. Due to the different types of compositions and polymerization of the resins this property is imperceptible to the clinician and only becomes visible through laboratory instruments. In this study was measured the degree of conversion of three brands of resin composites (Filtek Z250, Fill Magic and Opallis) for direct the restoration, by Fourier Transformed Infrared (FTIR) BXll - Perkin Elmer with absorbance in the wave numbers 1297 ± 10 cm-1 1319 ± 10 cm-1 and 1637 ± 10 cm-1 in function of the power of light curing units Bisco (300 mW/cm2 and 600 mW/cm2) and DMC IS Ultra Blue (350 mW/cm2) .A sample of 10 mg ± 2 mg was placed on the ZnSe ATR (ATR Miracle, Perkin Elmer) and measured before the polymerization (T0) with the parameters: 600 - 4000 cm-1 and 32 scans. After this initial reading of the sample was polymerized for 20s, 40s, 60s and 80s with the light-curing unit and desired intensity. The resins Filtek Z250, FillMagic and Opallis showed a similar and satisfactory degree of conversion with the two intensities of the curing unit Bisco (300 and 600 mW) tested. With the DMC curing unit the resins Opallis and Fill Magic failed to reach the goal of 52% conversion. The ideal combination of Light-Curing Unit, resin and polymerization time is of immense importance to the success of the restoration


Assuntos
Cura Luminosa de Adesivos Dentários , Espectrometria de Fluorescência/métodos , Luz , Fenômenos Químicos , Polimerização , Resinas Compostas , Restauração Dentária Permanente , Teste de Materiais/métodos , Interpretação Estatística de Dados
15.
Rev. odonto ciênc ; 26(4): 321-325, 2011. tab
Artigo em Inglês | LILACS, BBO | ID: lil-625016

RESUMO

PURPOSE: To analyze, in vitro, the influence of a quartz-tungsten-halogen (QTH) and a plasma arc (PAC) on the degree of conversion and hardness of a composite resin, as well as the heat generated by the units. METHODS: Transbond XT disks were prepared and light-cured for 10, 20 and 30 seconds with a QTH (Curing Light XL 3000) or with a PAC (Apollo 95E) for 1, 2 and 3 seconds. The composite resin polymerization was evaluated by infrared spectrophotometry (FTIR) and Knoop hardness number (KHN). The temperature at the curing tip was evaluated. The results were analyzed using ANOVA and Tukey test (α=0.05). RESULTS: According to FTIR and KHN, the polymerization of the composite resin was statistically higher with the QTH. The temperature obtained with the QTH 20 s (45.44ºC) and 30 s (45.84ºC) was statistically higher than the QTH 10 s (39.90ºC). The PAC 1 s (27.12ºC), 2 s (28.48ºC) and 3 s (29.96ºC) presented the lowest temperature and did not differ statistically among them. CONCLUSION: Transbond XT light-activated for 10, 20 and 30 seconds with the QTH presented higher degree of conversion and hardness in comparison with those obtained with the PAC for 1, 2 and 3 seconds, and the QTH generated more heat than the PAC.


OBJETIVO: Analisar, in vitro, as fontes luminosas Halógena (QTH) e Xenon (PAC) no grau de conversão e dureza de uma resina composta e também o calor gerado por estas unidades. METODOLOGIA: discos com resina Transbond XT foram fotoativados por 10, 20 e 30 segundos com QTH (Curing light XL 3000) ou com PAC (Apollo 95E) por 1, 2 e 3 segundos. A resina composta foi analisada por meio de espectrofotometria infravermelha (FTIR) e pelo teste de dureza Knoop (KHN). A temperatura na ponta dos aparelhos foi também avaliada. Os resultados foram analisados usando ANOVA e Tuckey test (α=0.05). RESULTADOS: Conforme FTIR e KHN a polimerização do compósito foi estatisticamente maior com QTH. A temperatura obtida do QTH com 20 segundos (45,44ºC) foi estatisticamente maior do que com 10 segundos (39,90ºC). O PAC com 1, 2 e 3 segundos apresentou as temperaturas mais baixas e não diferem estatisticamente entre si. CONCLUSÃO: A resina Transbond XT fotoativada por 10, 20 e 30 segundos com QTH apresentou maior grau de conversão e dureza em comparação com PAC por 1, 2 e 3 segundos. O QTH produziu mais calor que o PAC.


Assuntos
Dureza/fisiologia , Lâmpadas de Polimerização Dentária , Resinas Compostas , Xenônio/farmacologia
16.
Rev. bras. odontol ; 67(2): 220-227, jul.-dez. 2010. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-586831

RESUMO

O objetivo do presente artigo é avaliar a influência da fotoativação com lâmpadas halógena e LED no grau de conversão dos compósitos microíbrido e nanoparticulado. Trinta amostras foram divididas em seis grupos variando tipo de resina, tipo de lâmpada e tipo de ativação. Para medir grau de conversão foi utilizada espectrofotometria por Raman. As amostras não polimerizadas e polimerizadas foram comparadas para avaliar se houve diferença no grau de conversão para Ho1: os diferentes compósitos; Ho2: as diferentes fontes luminosas e Ho3: os diferentes modos de ativação. Para análise estatística foram utilizados Anova e T de Student. Os resultados mostraram haver diferença estatística, demonstrando maior grau de conversão para resinas nanoparticuladas, o que pode estar ligado à presença de TEGDMA em sua matriz.


The objective this paper is evaluate influence of photoativation with halogen light and LED on conversion’s degree of two different composites. Thirty samples were divided in six groups considering type of composite, photoativation unit and type of polimerization used. Ramanspectrophotometry was used to measure the degree of conversion. The Non-polimerized and polimerized sampleswere compared to evaluate if there was any difference on the degree of conversion to Ho1: composites; Ho2:diferent polimerization sources and Ho3: diferent activation modes. Anova and T Student were utlilized to statisticalanalysis. Results showed difference between the degrees of conversion of the different composites expressing ahigher value for nanoparticulate resins, which could be explained by the presence of the TEGDMA on the composition of the matrix.


Assuntos
Resinas Compostas , Cura Luminosa de Adesivos Dentários/métodos , Halogenação , Análise Espectral Raman
17.
Rev. clín. pesq. odontol. (Impr.) ; 6(3): 223-230, set.-dez. 2010. tab
Artigo em Inglês | LILACS, BBO | ID: lil-617388

RESUMO

Objectives: The aim of this study was to compare the degree of conversion of different shades ofa composite resin activated with two different light sources. Material and method: Composite resin(Charisma™), A2 and SL were photoactivated with a halogen lamp and a LED based system, at threedifferent light activation times (10, 20 and 40s). The degree of conversion was analyzed by ultravioletspectroscopy with variation in wavelength. The data were submitted to ANOVA and the Games Howelltest (5%). Results: The resin composite shade SL presented a higher degree of conversion in depth thanthe resin composite shade A2. The three light activation times had no infl uence on the degree of conversionin the groups of resin composite SL light activated with halogen light and LED. Conclusion: It wasconcluded that the resin composite SL presented the highest degree of conversion, irrespective of thelight polymerization time and the light source used.


Objetivos: O objetivo deste estudo foi comparar o grau de conversão de uma resina composta com diferentes cores,utilizando duas fontes ativadoras. Material e método: Utilizou-se uma resina composta (Charisma®) nas coresA2 e SL, fotoativada com lâmpada halógena e com sistema LED, em três tempos de fotoativação (10, 20 e 40s).O grau de conversão foi analisado por meio da espectrometria ultravioleta, com variação no comprimento de onda.Os dados obtidos foram submetidos à ferramenta ANOVA e ao teste Games Howel (5%). Resultados: A resinacomposta cor SL apresentou maior grau de conversão que a resina composta cor A2. Os três tempos de fotoativaçãonão infl uenciaram no grau de conversão nos grupos de resina composta SL fotoativadas com luz halógena e LED.Conclusão: A resina composta SL apresentou maior grau de conversão independente do tempo de fotopolimerizaçãoe da fonte de luz utilizada.


Assuntos
Lâmpadas de Polimerização Dentária , Resinas Compostas/efeitos da radiação , Luz , Polimerização/efeitos da radiação , Análise de Variância , Transição de Fase , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
18.
Rev. bras. odontol ; 67(1): 24-27, jul.-dez. 2010. tab
Artigo em Português | LILACS, BBO | ID: lil-563832

RESUMO

O objetivo do trabalho foi avaliar o grau de conversão de três resinas compostas fotoativadas (Fill Magic, TPH Spectrum e Te-Econom). Cento e vinte amostras foram preparadas, as quais foram irradiadas por 20 e 40s usando quatro fontes diferentes (duas halógenas e duas à base de LED). O grau de conversão foi avaliado a partir de dados de absorção no infravermelho próximo obtidos em um espectrofotômetro infravermelho. Os resultados mostram que o grau de conversão aumenta com o tempo de irradiação somente quando as resinas foram irradiadas com fontes de luz com densidade de potência menor do que 233 mW/cm2. Todas as três resinas alcançaram o nível de conversão tipicamente observado em resinas fotoativadas comerciais.


Assuntos
Fenômenos Físicos , Resinas Compostas/efeitos da radiação , Espectroscopia de Infravermelho com Transformada de Fourier
19.
São José dos Campos; s.n; 2010. 126 p. ilus, graf, tab.
Tese em Português | LILACS, BBO | ID: lil-587618

RESUMO

O objetivo deste trabalho foi avaliar a translucidez de diferentes cores da cerâmica, o grau de conversão de diferentes cores do agente de fixação resinoso e a resistência de união entre a cerâmica e a dentina, variando as cores da cerâmica e do agente de fixação e o tempo de fotoativação. A hipótese é que quanto mais escuros o agente de fixação resinoso e a cerâmica, menor translucidez, menor conversão dos monômeros, mais baixa será a resistência adesiva, portanto maior tempo necessário para fotoativação. Três discos da cerâmica Vita VM7 com dimensão de 20 x 2 mm nas cores Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3 e dois discos com 20 x 2,5 mm da mesma cerâmica nas cores Base Dentine 0M1 e Base Dentine 5M3 foram usados para determinar a percentagem de translucidez através do espectrofotômetro MiniScan. Para se obter o grau de conversão (GC), os cp do agente de fixação (Variolink II; A3 Amarelo e transparente; espessura: 100 μm) foram fotoativados sob um bloco cerâmico (espessura: 2 mm; Base Dentine 0M1, Base Dentine 2M2 e Base Dentine 5M3) por 20 ou 40 s. Cpfotoativados sem o bloco cerâmico foram usados como controle. Dezesseis grupos (n=3) foram avaliados. Espectrometria de Micro-ATR/FTIR foi utilizada para avaliar a extensão da polimerização de todos os cp depois de 24 h. A %GC foi calculada e os dados foram analisados através de ANOVA 1-fator e teste de Tukey ( =0,05). Para avaliar adesão, a dentina da superfície oclusal de 80 molares humanos hígidos foi exposta e condicionada com ácido fosfórico 37% e adesivo (Excite DSC). Oitenta blocos (7,2 x 7,2 x 2,5 mm) da mesma cerâmica, nas cores Base Dentine 0M1 e Base Dentine 5M3, foram confeccionados de acordo com as instruções do fabricante. A superfície cerâmica foi tratada com ácido fluorídrico 10% por 60 s e silanizada. Os blocos cerâmicos de cada cor foram cimentados sobre a dentina tratada usando o agente de fixação de cor A3 Amarelo ou transparente. Os cp foram fotoativados...


The aim of this study was to evaluate the translucency of different ceramics hades, degree of conversion of different resin cement and the bonds trength between a feldspathic ceramic and dentin using different resin cement and ceramic shades, and the activation time. The hypothesis is the darker the resin cement and ceramic, lower the translucency; the lower the degree of monomers conversion, lower the bond strength, then the activation time should be higher. Three discs of Vita VM7 ceramic with 20 x 2 mm and shades: Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3, and two discs with 20 x 2.5 mm of the same ceramic and shades: Base Dentine 0M1 and Base Dentine 5M3 were used to determine the translucency percentage of each sp using the MiniScan espectrophotometer. For measure the degree of conversion (DC), the resin cement (Variolink II; A3 Yellow and transparent) specimens(thickness: 100 μm) were photocured under a ceramic block (2mm-thick;Base Dentine 0M1, Base Dentine 2M2 and Base Dentine 5M3) for 20 or 40 s. Specimen photocured without the ceramic block were used as control. Sixteen groups (n=3) were evaluated. Micro-ATR/FTIR spectrometry was used to evaluate the extent of polymerization of all sp after 24 h. The %DC was calculated and the data were analyzed using ANOVA 1-way and Tukey test ( =0,05). For the microtensile bonds trength test, the occlusal dentin surface of eighty molars were exposed and etched with 37% phosphoric acid and an adhesive (Excite DSC) was applied. Eighty blocks (7.2 x 7.2 x 2.5 mm) of Base Dentine 0M1 and Base Dentine 5M3 of Vita VM7 ceramic were produced according to the manufacturers. The ceramic surface was etched with 10% hydro fluoric acid for 60 s, followed by the application of a silane agent and a dualcured resin cement (Variolink II; base and catalyst: A3 Yellow; base and catalyst: transparent), according to the manufacturers’ recommendations.Ceramic blocks of each shade were...


Assuntos
Cerâmica , Cimentos Dentários , Cura Luminosa de Adesivos Dentários , Cor
20.
Bauru; s.n; 2010. 111 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-557737

RESUMO

Este estudo teve como objetivo avaliar os efeitos de variações no protocolo de ativação e envelhecimento acelerado em algumas propriedades de cimentos resinosos de polimerização dual. Adicionalmente, investigaram-se os efeitos da variação da temperatura ambiente e envelhecimento acelerado no tempo de trabalho e tempo de presa dos cimentos quando ativados exclusivamente pela reação química. As propriedades avaliadas foram o grau de conversão, determinado por espectrometria no infravermelho com transformada de Fourier (FTIR-ATR), microdureza Knoop, expressa em KHN, e resistência mecânica à tração expressa em MPa. Os tempos de trabalho e tempos de presa foram determinados por um reômetro oscilatório com controle de temperatura da plataforma de teste estabelecida em 24oC ou 37oC. O envelhecimento acelerado foi determinado pela armazenagem dos cimentos, em suas embalagens originais, e após os testes iniciais, em estufa a 37oC por 12 semanas.A variável de modo de ativação foi determinada em 3 níveis. Os cimentos foram manipulados de acordo com as instruções dos fabricantes e ativados por luz imediatamente (controle), ativados por luz após 10 minutos de reação química no escuro (Exp 1) ou mantidos no escuro por 15 minutos, permitindo a reação química, mas sem fotoativação (Exp 2). Os cimentos tiveram suas propriedades avaliadas em função desses diferentes modos de ativação, antes e após o envelhecimento acelerado. Cimento exclusivamente ativado pela reação química foi empregado como controle quando necessário. Os diversos resultados podem ser resumidos em alguns aspectos de interesse. O tempo de trabalho e o tempo de presa de todos cimentos foram afetados significantemente pela temperatura e envelhecimento (p<0.05). O aumento da temperatura acelerou os tempos de trabalho e presa. Os efeitos do envelhecimento foram materiaisdependentes. Alguns materiais apresentaram redução, enquanto outros apresentaram aumento dos tempos de trabalho e presa, independentemente da...


The study aimed to evaluate the effects of curing protocol and accelerated aging on some properties of dual-cure resin cements. Additionally, the effects of different ambient temperature and aging on the working and setting times were investigated when cements were self-cured only. Properties evaluated were degree of conversion as determined by FTIR-ATR spectroscopy, Knoop microhadness as expressed by KHN, and tensile strength as expressed in MPa. Working time and setting time were determined by an oscilating rheometer with controlled temperature stage at either 24oC or 37oC. Accelerated aging was performed by storing the original product kits in an oven at 37oC for 12 weeks after initial testing had been executed. Different curing protocols were established in 3 levels. Cements were manipulated according to the manufacturers instructions and light-activated immediately (control), light-activated after 10 minutes delay of self-curing in the dark (Exp 1), or simply allowed to self-cure for 15 minutes in the dark (Exp 2). Properties were evaluated according to the different curing protocol and both before and after aging. Exclusively self-curing cement was used as control product when appropriate. The results can be summarized in some aspects of interest. The working time and setting time of all products were significantly affected by temperature and aging (p<0.05). Increased temperature resulted in shorter working time and setting time. The effects of aging were material dependent. Some products presented reduced working and setting times, while others behave otherwise, regardless of the temperature. Curing mode and aging significantly affected the properties of the cements (p<0.05). In general, the degree of conversion increased with time after light-activation. The curing delay for 10 minutes caused alterations in the degree of conversion, regardless of aging, for some products, but not all. Aging affected the curing kinectics and general properties of all...


Assuntos
Cimentos de Resina/efeitos da radiação , Cimentos de Resina/química , Colagem Dentária/métodos , Análise de Variância , Testes de Dureza , Teste de Materiais , Fenômenos Químicos , Reologia , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA