Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Endocrine Surgery ; : 25-29, 2017.
Artigo em Coreano | WPRIM | ID: wpr-33721

RESUMO

PURPOSE: The use of sealing devices such as Harmonic scalpel and Ligasure is increasing steadily in thyroid surgery. The Harmonic Focus (HF) is an ultrasonic device that enables simultaneous vessel sealing and tissue coagulation, designed for open surgery such as thyroidectomy. The aim of this study is to assess the efficiency and safety of HF use in thyroid surgery compared to Conventional Tying (CT). METHODS: A prospective study was conducted to compare the efficacy of HF versus CT. We evaluated 50 patients who underwent surgery for thyroid tumor at Korea University Anam Hospital. All patients underwent total thyroidectomy with central neck dissection after being randomly allocated into two groups: HF group and CT group. The differences in surgical outcomes and postoperative complications by device use, i.e. group assignment, were statistically analyzed. RESULTS: There were no differences in number of retrieved lymph nodes (P=0.595), number of resected parathyroid glands (P=0.330), immediate postoperative iPTH (P=0.252), length of hospitalization (P=0.375) between HF group and CT group. However, operative time was shorter in HF group than CT group (106.07±20.92 min vs. 136.54±38.24 min, P=0.046). Postoperative complications of wound infection, seroma, hematoma, chyle leakage, vocal cord palsy, and hypoparathyroidism did not differ between groups. CONCLUSION: HF is a safe, effective, and time-saving technique; outcomes are comparable with CT. Both intraoperative and postoperative variables were similar between groups. Future larger studies are warranted to further investigate the effect on postoperative complications.


Assuntos
Humanos , Quilo , Hematoma , Hospitalização , Hipoparatireoidismo , Coreia (Geográfico) , Linfonodos , Esvaziamento Cervical , Pescoço , Duração da Cirurgia , Glândulas Paratireoides , Complicações Pós-Operatórias , Estudos Prospectivos , Seroma , Glândula Tireoide , Tireoidectomia , Ultrassom , Paralisia das Pregas Vocais , Infecção dos Ferimentos
2.
China Oncology ; (12): 333-337, 2016.
Artigo em Chinês | WPRIM | ID: wpr-490029

RESUMO

Background and purpose:In recent years, energy-based instruments have been widely used in today’s open surgeries. Harmonic Focus? (HF) and Ligasure Small Jaw? (LSJ) are both custom-made for thyroid open surgery. This study aimed to explore the effcacy and safety of HF and LSJ in open thyroidectomy.Methods:The data from patients who undertook total thyroidectomy with central neck dissection by the same surgeon during last year in this hospital were reviewed. HF was used in 100 patients, and LSJ was used in 104 patients. The effectiveness was appraised by comparing operation time and postoperative volume of drainage on the ifrst postoperative day. The safety was appraised by comparing the incidence of postoperative complications.Results:The results of the effectiveness:the average duration of operation was (95.8±18.0) min for HF group, and (97.8±19.1) min for LSJ group, there was no statistical signiifcance (P=0.363). Postoperative volume of drainage on the ifrst postoperative day was (35.2±20.3) mL for HF group, and (36.3±23.8) mL for LSJ group, there was no statistical signiifcance (P=0.977). One patient (1.0%) had temporary vocal cord paralysis in HF and one had postoperative hematoma (1.0%) in LSJ group. Temporary hypo-parathyroidism was detected in 18 patients (18.0%) of HF group, and 16 patients (15.4%) of LSJ group. The decline of parathyroid hormone during the ifrst postoperative day was (12.3±12.8) pg/mL in HF group, and (13.9±13.4) pg/mL in LSJ group. The decline of serum calcium was (0.20±0.13) mg/dL in HF group, and (0.20±0.16) mg/dL in LSJ group. There were all no statistical signiifcances (P>0.05).Conclusion:Both HF and LSJ are safe and effective in open thy-roidectomy without similar operative complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA