Military Medical Sciences ; (12): 934-937, 2015.
Artigo em Chinês | WPRIM | ID: wpr-483880

RESUMO

Objective To study the stability of anticoagulant peptide Hirulog-S and its lyophilized product, and to provide data on the storage conditions and clinical applications.Methods RP-HPLC was used to determine the content and the related substances of Hirulog-S and its lyophilized powder with influence factor test, accelerated test and long-term storage test.Results Light, temperature and humidity had no significant effect on the stability of Hirulog-S and its lyophilized powder in the influence factor test.The content and related substances of Hirulog-S and its lyophilized powder did not significantly change in the accelerated test ( 40℃, RH75%) and 24-month long-term storage test at room temperature and 4℃.Conclusion Hirulog-S and its lyophilized product are very stable, even after being stored at room temperature for two years.