Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088976

RESUMO

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Facoemulsificação/métodos , Córnea/patologia , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Lentes Intraoculares Multifocais , Câmara Anterior/patologia , Período Pós-Operatório , Valores de Referência , Refração Ocular/fisiologia , Fatores de Tempo , Acuidade Visual/fisiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Biometria , Resultado do Tratamento , Córnea/diagnóstico por imagem , Interferometria/instrumentação , Interferometria/métodos , Câmara Anterior/diagnóstico por imagem
2.
Rev. cuba. oftalmol ; 32(2): e661, abr.-jun. 2019.
Artigo em Espanhol | LILACS | ID: biblio-1093698

RESUMO

RESUMEN La interferometría de coherencia óptica es un procedimiento esencial para calcular la potencia óptica de la lente intraocular. La presente revisión describe la evolución de la biometría óptica por interferometría, las nuevas plataformas, las características técnicas, los parámetros de calibración, la interpretación de los resultados y las situaciones especiales con indicación de cirugía de catarata. Para efectuar el trabajo fueron consultadas las bases de datos de la plataforma Infomed, específicamente en la Biblioteca Virtual de Salud, PubMed, Cochrane Database-Wiley Online Library, LILACS y Scielo. El IOL Máster favorece la medición de los parámetros biométricos oculares, ya que realiza mediciones sólidas y repetibles que incluye fórmulas de cuarta generación para el cálculo de potencia de lentes intraoculares. Actualmente se dispone en el mercado de varias plataformas para la biometría ocular usando los métodos interferométricos de alta resolución que tienen el potencial de mejorar significativamente los resultados refractivos. Estos estudios son de alta predictibilidad, lo cual permite obtener una buena agudeza visual y evita la sorpresa refractiva((AU)


ABSTRACT Optical coherence interferometry is an essential procedure for calculating the optical power of the intraocular lens. The present review describes the evolution of optical biometry by interferometry, the new platforms, technical features, calibration parameters, interpretation of results, and special situations in which cataract surgery is indicated. Information was collected from the databases on the Infomed platform, specifically the Virtual Health Library, PubMed, Cochrane Database-Wiley Online Library, LILACS and Scielo. IOL Master facilitates the measurement of ocular biometric parameters, since it performs solid, repeatable measurements that include fourth-generation formulas for the calculation of intraocular lens power. Several ocular biometry platforms are currently available in the market which use high resolution interferometric methods with the potential to significantly improve refractive results. These studies are characterized by their high predictability, making it possible to obtain good visual acuity and avoid refractive surprise(AU)


Assuntos
Humanos , Extração de Catarata/efeitos adversos , Biometria/métodos , Tomografia de Coerência Óptica/métodos , Interferometria/métodos , Literatura de Revisão como Assunto , Bases de Dados Bibliográficas
3.
Rev. cuba. oftalmol ; 27(3): 350-358, jul.-set. 2014. tab
Artigo em Espanhol | LILACS, CUMED | ID: lil-744014

RESUMO

OBJETIVO: determinar la efectividad de la biometría de inmersión para el cálculo del lente intraocular. MÉTODOS: se realizó un estudio observacional descriptivo, prospectivo. El universo estuvo constituido por los pacientes operados de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", entre enero y septiembre de 2011. La muestra estuvo conformada por 39 ojos de 34 pacientes que cumplieron con los criterios de inclusión establecidos para la investigación y fueron operados por la técnica de facoemulsificación con previo cálculo del lente intraocular por biometría de inmersión e interferometría de coherencia óptica. RESULTADOS: el promedio de edad fue de 72,33 años, con un predominio del sexo femenino. La diferencia de longitud axial promedio entre los pacientes calculados por inmersión y los de IOL Máster fue de 0,09 mm, mientras que la diferencia de profundidad de la cámara anterior fue de 0,19 mm. Se obtuvo una diferencia de 0,13 D y no existió diferencia significativa en cuanto al cálculo del poder del lente intraocular entre ambos métodos. CONCLUSIONES: los valores de longitud axial y de profundidad de cámara anterior obtenidos mediante biometría de inmersión pueden ser utilizados para calcular con efectividad el poder del lente intraocular de los pacientes que serán sometidos a cirugía de cataratas, lo que demuestra ser una alternativa en ausencia del IOL Máster.


OBJECTIVE: to characterize the functional capacity and the quality of life of the elderly people with macular degeneration and low vision who were seen at "Ramon Pando Ferrer" Cuban Institute of Ophthalmology from January to June 2013. METHODS: Cross-sectional and descriptive study that included the following variables: age, sex, race, best corrected near visual acuity using Zeiss chart before and after visual rehabilitation, visual disability, functional capacity for daily life activities, clinical type of macular degeneration, risk factors for the disease, reason for visual rehabilitation and prescribed optical and non-optical aids. RESULTS: the disease prevailed in females (55,2 %), 75-79 years-old age group and Caucasians. Predominant visual disability was mild to moderate low vision; the mostly found functional capacity was independence with some limitations. Dry macular degeneration was present in 82,7 % of cases; the most frequent risk factor was smoking (82,7 %); reading and writing was the main motivation and a large number of patients improved their visual acuity after rehabilitation. The optical and non-optical aids that were mostly prescribed included microscopes and lighting. CONCLUSIONS: females, 75-79 years-old age group and Caucasians are the risk factors that cause the highest number of cases with macular degeneration and low vision. Visual disability prevailed among those classified as mild to moderate low vision patients. Dry macular degeneration .


Assuntos
Humanos , Feminino , Idoso , Extração de Catarata/métodos , Biometria/métodos , Facoemulsificação/métodos , Lentes Intraoculares/estatística & dados numéricos , Epidemiologia Descritiva , Estudos Prospectivos , Estudo Observacional
4.
Arq. bras. oftalmol ; 77(4): 233-237, Jul-Aug/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-728664

RESUMO

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P<0.05) measurement for the anterior chamber depth, anterior chamber angle, and pupil diameter, than the Pentacam HR system. Comparable values (P>0.05) for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences. .


Objetivo: Avaliar a medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagens de Scheimpflug diferentes. Métodos: Este estudo transversal incluiu 80 olhos direitos de 80 indivíduos com idades entre 20 e 40 anos. O equivalente esférico variou de -4,25 a +1,00 dioptrias (D). A profundidade da câmara anterior de cada olho, a distância branco a branco, o ângulo da câmara anterior e o diâmetro pupilar, foram medidos para visão de longe usando tanto o Galilei G4 (câmera de Scheimpflug dupla) e os sistemas Pentacam HR (câmera de Scheimpflug simples). Resultados: A profundidade média da câmara anterior foi 3,12 ± 0,23 mm e 3,19 ± 0,24 mm, usando o Galilei G4 e o Pentacam HR, respectivamente. A distância média da medida de branco a branco com o Galilei G4 foi 11,84 ± 0,31 mm e com o HR Pentacam foi 11,90 ± 0,43 mm. A média do diâmetro pupilar foi 3,22 ± 0,58 mm e 3,22 ± 0,52 mm, medidos com o Galilei G4 e o Pentacam HR, respectivamente. Finalmente, a média do ângulo da câmara anterior foi de 34,30 ± 2,86 graus quando foi medido com o G4 Galileu, e 39,26 ± 2,85 graus com o Pentacam HR. A comparação revelou que o dispositivo Galilei G4 mediu significativamente menor (P<0,05) profundidade da câmara anterior, ângulo da câmara anterior e diâmetro da pupila do que o sistema de Pentacam HR, enquanto valores comparáveis (P>0,05) entre os dois dispositivos Scheimpflug foram obtidos para as medidas da distância branco a branco. Conclusão: O Galileu G4 e o Pentacam HR não podem ser usados indiferentemente, devido ás diferenças entre os dois aparelhos terem sido significativas sob o ponto de vista clínico. .


Assuntos
Adulto , Humanos , Adulto Jovem , Câmara Anterior/anatomia & histologia , Imageamento Tridimensional/instrumentação , Interferometria/instrumentação , Iris/anatomia & histologia , Técnicas de Diagnóstico Oftalmológico , Pupila , Fotografação/instrumentação
5.
Araraquara; s.n; 2013. 100 p. ilus, tab.
Tese em Português | LILACS, BBO | ID: biblio-866885

RESUMO

A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir que o posicionamento dos implantes e o tipo de conexão protética em reabilitação anterior de maxila influenciam a distribuição e intensidade de tensão/deformação nas estruturas da prótese implanto-suportada e ainda que o MEF pode ser usado como uma eficiente técnica para a análise de tensão, deformação e deslocamento quando utilizada com modelos validados experimentalmente


The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior maxilla and moreover the FEM can be used as an efficient technique for analysis of stress, strain and displacement when used with experimentally validated models


Assuntos
Fenômenos Biomecânicos , Análise de Elementos Finitos , Maxila , Implantes Dentários , Interferometria , Prótese Dentária Fixada por Implante
6.
Araraquara; s.n; 2013. 93 p. ilus.
Tese em Português | LILACS, BBO | ID: biblio-866884

RESUMO

A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir...


The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior...


Assuntos
Humanos , Implantes Dentários , Prótese Dentária Fixada por Implante , Interferometria , Análise Numérica Assistida por Computador
7.
Rev. cuba. oftalmol ; 25(1): 65-71, ene.-jun. 2012.
Artigo em Espanhol | LILACS | ID: lil-629491

RESUMO

Objetivo: Comparar valores del espesor corneal central obtenidos mediante la paquimetría con el sistema de interferometria de coherencia parcial (Lenstar) con los sistemas Scheimpflug (Pentacam; Oculus) y Galilei (Ziemer, Suiza). Métodos: Se realizó un estudio prospectivo, comparativo en 120 ojos de 60 pacientes. Para la comparación se tomaron varias mediciones recomendadas por los fabricantes para probar la eficacia del equipo con el nuevo biómetro Lenstar LS 900 (Haag Streit AG) y con los equipos Pentacam y Galilei. La comparación de los valores se realizó mediante el análisis de regresión lineal y correlación de Pearson. Resultados: El análisis reveló que existe una alta correspondencia en los valores del espesor corneal central entre Lenstar y los topógrafos Galilei y Pentacam. Conclusiones: Existe una alta correspondencia entre los valores del espesor corneal central obtenidos por los equipos Lenstar, Pentacam y Galilei. Por esto el equipo Lenstar es útil en la cirugía de catarata y la cirugía refractiva.


Objective: To compare the central corneal thickness measurements taken by pachimetry with the partial coherence interferometry, Lenstar and with Scheimpflug systems (Pentacam; Oculus) and Galilei (Ziemer, Switzerland). Methods: Comparative and prospective study of 120 eyes from 60 patients. Several recommended measurements were taken with the optical biometers LenstarLS 900 (Haag Streit AG) and with Pentacam y Galilei topographers. The results were evaluated using the linear regresión analysis and Pearson´s correlation. Results: There is high correlation among the central corneal thickness measurements taken by the Lenstar equipment and topographers Pentacam and Galilei. Conclusion: The new biometer LENSTAR provided results that correlated very well with those of the Pentacam and Galilei systems. The Lenstar is a precise device that will be helpful for any cataract or refractive surgery.

8.
ImplantNews ; 9(1): 49-54, 2012. ilus
Artigo em Português | LILACS, BBO | ID: lil-642664

RESUMO

A região do colar cervical do implante é constantemente exposta aos esforços mastigatórios/parafuncionais, representando uma zona em potencial à ocorrência de deformações, principalmente nos implantes de conexão interna e de reduzido diâmetro. Estas sobrecargas representam um dos fatores responsáveis pela perda óssea ao redor dos implantes. O presente estudo avaliou o comportamento do colar de implantes friccionais (Kopp) de dois diâmetros (4,3 mm e 5,5 mm) sob cargas compressivas estáticas (cêntrica e excêntrica) de duas intensidades (50 N e 100 N) por meio da Interferometria Eletrônica de Padrões de Speckle (Espi – Electronic Speckle Pattern Interferometry). A técnica Espi consiste na comparação de imagens, de antes e após o carregamento, obtidas a partir da reflexão de uma fonte de luz laser incidida sobre um objeto real de superfície rugosa, resultando em um padrão de franjas. O estudo in vitro visou testar a aplicabilidade da técnica Espi para avaliar implantes e a hipótese de que quanto maior o diâmetro do implante, maior é sua resistência ao deslocamento. Foi possível obter resultados qualitativos reprodutíveis acerca da deformação ao nível do colar do implante frente aos carregamentos, validando a técnica. Franjas horizontais foram observadas nas cargas cêntricas, demonstrando o deslocamento vertical do colar do implante e franjas diagonais nas cargas excêntricas, demonstrando o deslocamento de forma oblíqua. Estes deslocamentos podem sugerir a deformação sofrida pela amostra. A técnica Espi mostrou-se viável para avaliar as deformações da região observada e a hipótese foi confirmada, visto que no implante de menor diâmetro houve maior deformação.


The collar region of osseointegrated implants is frequently exposed to masticatory/parafunctional loads, representing a potential area subjected to deformation, especially in narrow-diameter and internal connection dental implants. This study evaluated the effect of the collar of frictional implants (Kopp) at two different diameters (4.3 mm and 5.5 mm) under static compressive loads (centric and eccentric) of two magnitudes (50 and 100 N) through the Electronic Speckle Patterns Interferometry (Espi). The Espi is a technique still little used in dentistry that consists in comparing images before and after loading, obtained from the reflection of a laser light source focused on a real object surface resulting in a fringe pattern. The in vitro study aimed to test the applicability of the ESPI technique and the hypothesis that as larger is the implant diameter, as greater is the resistance to strain at level of implant collar. It was possible to obtain reproducible qualitative results about the deformation of the implant collar when subjected to loading, validating this technique. Fringes were observed horizontally in the centric loads and diagonally in eccentric loads. These results may suggest the deformation suffered by the sample. The Espi technique was feasible to assess the deformation of the region observed and the hypothesis was confirmed, since the smaller implant diameter presented greater strain.


Assuntos
Força Compressiva , Implantes Dentários , Interferometria , Estresse Mecânico
9.
CES odontol ; 23(2): 17-24, jul.-dic. 2010. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-612559

RESUMO

Introducción y Objetivo: La armonía facial es un elemento que juega un rol importante en la estética del rostro humano, contribuyendo casi en su totalidad al ajuste de las deformaciones producidas en el mismo, debido a la ausencia de una prótesis total o su errada colocación. El objetivo del presente estudio está enfocado a determinar y visualizar a través de imágenes y su respectivo levantamientotopográfico, las dimensiones verticales del rostro humano, con la finalidad de detectar de manera precisa las medidas necesarias, en cuanto a rehabilitación protésica se refiere. Materiales yMétodos: Tres casos clínicos: un caso edéntulo total antes y después de la rehabilitación protésica, al cual se le aplicó la técnica de proyección lineal y el cálculo de las dimensiones verticalesrespectivas, los otros dos casos uno se le aplicó la técnica de proyección lineal y el otro se le aplicó la técnica de patrones moiré, a todos se les realizó el levantamiento topográfico de la imagen en 3D. Resultados: La propuesta aplicada en seres humanos permite el cálculo de los parámetros quelogran armonía del perfil facial y el levantamiento de las imágenes en 3D basada en dos técnicasde interferometría: proyección lineal y patrones moiré. Conclusión: Ambas técnicas, ofrecen alodontólogo la visualización en 3D del rostro además, la técnica de proyección lineal permite la obtención de las medidas requeridas con mayor precisión y con técnicas no invasivas.


Introduction and Objective: Facial harmony is an element that plays an important role in the esthetics of the human face, contributing almost totally to the adjustment of deformations produced in it due to the absence of complete denture or its incorrect installment. The objective of this study isto determine and visualize through images and their topographical elevation, the vertical dimensionsof the human face with the objective of detecting in a precise manner the necessary measurements regarding prosthetic rehabilitation. Materials and Methods: The sample comprises three cases: a completely edentulous patient before and after prosthetic rehabilitation on whom the linear projection technique and the calculation of the respective vertical dimensions was applied; on the secondcase a technical linear projection was used and on the third one the moiré patterns technique wasapplied; all were performed with 3D image mapping. Results: The proposal applied to humans allows the calculation of parameters that achieve harmony of the facial profile and mapping of 3Dimages, based on two interferometry techniques: linear projection and Moiré patterns. Conclusion: Both techniques offer the dentist a 3D visualization of the face, and in addition the linear projection technique allows obtaining the required measurements with greater precision and with a noninvasivetechnique.


Assuntos
Humanos , Estética Dentária , Interferometria , Topografia de Moiré
10.
Rev. cuba. oftalmol ; 23(1): 88-99, ene.-jun. 2010.
Artigo em Espanhol | LILACS | ID: lil-584986

RESUMO

OBJETIVO: Comparar la efectividad del cálculo del poder dióptrico de la lente intraocular con IOL Master y el método de biometría por aplanación convencional. MÉTODOS: Se seleccionó una muestra de 100 ojos (pacientes) mediante un muestreo simple aleatorio, en el Servicio de Catarata del Centro de Microcirugía Ocular, con diagnóstico de catarata unilateral o bilateral en la consulta preoperatorio, desde marzo hasta septiembre de 2006. Se clasificaron en dos grupos según el método utilizado para el cálculo de la lente intraocular. Se analizaron las variables: longitud axial media preoperatoria, promedio queratométrico preoperatorio, componente esférico esperado y obtenido, agudeza visual sin corrección y mejor agudeza visual corregida preoperatoria y posoperatoria. El análisis estadístico de los resultados se realizó mediante un análisis de varianza, la prueba t de Student de comparación de medias para datos pareados y chi cuadrado. Se utilizó un nivel de confiabilidad de 95 por ciento. RESULTADOS: Entre los principales resultados se encontró que la diferencia de las longitudes axiales entre los métodos IOL Master y biometría por aplanación A-Scan fue estadísticamente significativa. La agudeza visual sin corrección aumentó cuatro líneas y la mejor agudeza visual corregida seis líneas en el posoperatorio de los pacientes del grupo I. El 90 por ciento de los pacientes del grupo I, o sea, los calculados con IOL Master quedaron en la emetropía en cuanto al componente esférico. CONCLUSIONES: Se evidenció una diferencia significativa e inferior a la encontrada en estudios internacionales entre las longitudes axiales preoperatorias halladas mediante los métodos IOL Master y biometría por aplanación; resultaron superiores las calculadas por IOL Master. Se obtuvo ganancia en las líneas de la Cartilla de Snellen tanto de la agudeza visual sin corrección como la mejor agudeza visual corregida en ambos grupos (superior en el grupo II). Predomina ron los resultados refrac...


OBJECTIVE: to compare the effectiveness of the intraocular lens dioptric power calculation using IOL Master and the conventional applanation biometry. METHODS: A sample of 100 eyes (patients), diagnosed with unilateral or bilateral cataract in the preoperative consultation service, was selected through simple random sampling in the Ocular Microsurgery Center in the period from March to September, 2006. They were divided into two groups based on the method for intraocular lens calculation. The variables were preoperative mean axial length, preoperative keratometric average, expected and obtained spheral component, visual acuity without correction and better corrected visual acuity preoperatively and postoperatively. The statistical analysis of the results was made by variance analysis, Student's t test for paired mean comparisons and Chi square. The confidence level of 95 percent was used. RESULTS: Among the main results, it was found that the axial length differences between IOL Master and A-Scan applanation biometry was statistically significant. Visual acuity without correction increased 4 lines and the best corrected visual acuity increased 6 lines in the postoperative period of the group I patients. Ninety percent of the group I patients, whose visual acuity was calculated with IOL Master, reached emetropia in terms of the spheral component. CONCLUSIONS: A significant difference but lower than that found in the international studies among the preoperative axial lengths calculated through ILO Master and applanation biometry were evinced. The differences were higher in the lenghts calculated by IOL Master. There was improvement in the number of lines of Snellen´s chart both in the visual acuity without correction and the better corrected visual acuity in the two groups; being better in group II. The refractive results tending to emetropy prevailed, taking into consideration the spheral component reached in both groups, which were also higher in group I


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Biometria/métodos , Lentes Intraoculares/história , Microscopia de Interferência/métodos , Estudos Prospectivos
11.
Rev. cuba. oftalmol ; 23(supl.2): 665-677, 2010.
Artigo em Espanhol | LILACS | ID: lil-615606

RESUMO

OBJETIVOS: Comparar y evaluar la biometría ocular con el nuevo equipo de interferometría óptica de coherencia parcial (Lenstar) con el equipo de interferometría óptica de baja coherencia IOL Master y también con los sistemas topográficos Galilei y Pentacam. MÉTODOS: Se realizó un estudio descriptivo, transversal, en 120 ojos de 60 pacientes. Para el cálculo del lente intraocular se tomaron mediciones con un nuevo biómetro Lenstar LS 900 (Haag Streit AG) y con el IOL Master V.5 (Carl Zeiss Meditec AG). Se compararon mediante el análisis de regresión lineal y correlación de Pearson. También se compararon las medidas con las obtenidas por los equipos topógrafos Galilei y Pentacam. RESULTADOS: Existe una alta correspondencia en los valores biómetricos de longitud axial, queratometría y profundidad de la cámara anterior entre los equipos Lenstar e IOL Master. También se encontró una buena correspondencia entre las medidas de profundidad de cámara posterior y queratometría entre Lenstar y los topógrafos Galilei y Pentacam. CONCLUSIONES: El nuevo biómetro Lenstar, provee resultados que se correlacionan muy bien con aquellos obtenidos con los equipos IOL Master, Pentacam y Galilei. El equipo Lenstar es un equipo preciso que brinda información adicional por lo que es útil en la cirugía de catarata y la cirugía refractiva


OBJECTIVES: To compare and to evaluate the ocular biometry taken by a new optical partial coherence interferometry device (Lenstar),the low coherence optical interferometry equipment (ILO Master) and the topographic systems Pentacam y Galilei. METHODS: A descriptive cross-sectional study was conducted in 120 eyes from 60 patients. For the IOL calculation, the necessary measurements were taken with the new optical biometer Lenstar LS 900 (Haig Streit AG) and with the IOL Master V5 (Carl Zeiss Meditec AG). The results were evaluated using the linear regression analysis and Pearson´s correlation. The measures were then compared to those taken by topographic devices Galilei and Pentacam. RESULTS: There existed high correlation in biometric measurements of axial length, keratometry and anterior chamber depth between the Lenstar and the IOL Master. Good correlation was also found for the Keratometry and anterior chamber depth between the Lenstar and the topographs Pentacam and Galilei. CONCLUSION: The new biometer LENSTAR provided results that correlated very well with those of the IOL Master, Pentacam and Galilei systems. Lenstar is a precise device offering additional features that will be helpful for any cataract or refractive surgery


Assuntos
Biometria/métodos , Córnea/fisiopatologia , Interferometria/métodos , Topografia da Córnea/métodos , Estudos Transversais , Epidemiologia Descritiva , Valores de Referência
12.
Interciencia ; 33(7): 542-546, jul. 2008. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: lil-630660

RESUMO

Se utilizaron la interferometría de luz blanca de barrido (ILBB) y la microscopía electrónica de barrido (MEB) con el fin de examinar y evaluar la superficie de muestras de aluminio 3003 corroídos en atmósfera de niebla salina. La comparación de estas dos técnicas de evaluación permitió apreciar que mientras la ILBB proporciona información cuantitativa acerca de la profundidad del ataque, la MEB ofrece mayores detalles del deterioro ocurrido en la matriz debido al proceso de corrosión. Adicionalmente, la MEB permitió establecer el rol de las partículas intermetálicas de segunda fase en la formación de micropilas galvánicas intermetálicos/matriz, responsables del ataque por picadura en la aleación comercial de aluminio 3003 en medio ambiente salino.


Scanning white light interferometry (SWLI) and scanning electron microscopy (SEM) were used to examine and evaluate the surface of commercial 3003 aluminum alloy samples, corroded by pitting in a saline fog atmosphere. From the comparison of the two evaluation techniques it was appreciated that while the SWLI provides quantitative information about the depth of the attack, the SEM permits detailed observation of the damage that takes place in the matrix due to the corrosion process. Furthermore, the evaluation by MEB made it possible to establish the role of the second phase intermetallic particles in the formation of galvanic micro cells intermetallics/matrix, responsible for the pitting attack of the commercial aluminum alloy 3003 in saline environment.


Utilizaram-se a interferometria de luz branca de varredura (ILBV) e a microscopia eletrônica de varredura (MEV) com a finalidade de examinar e avaliar a superfície corroída de amostras de alumínio 3003 em atmosfera de neblina salina. A comparação de estas duas técnicas de avaliação permitiu apreciar que enquanto a ILBV proporciona informação quantitativa a respeito da profundidade do ataque, a MEV oferece maiores detalhes do deterioro ocorrido na matriz devido ao processo de corrosão. Adicionalmente, a MEV permitiu estabelecer o papel das partículas intermetálicas de segunda fase na formação de micropilhas galvânicas intermetálicos/matriz, responsáveis do ataque por picada na liga comercial de alumínio 3003 em ambiente salino.