Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. med. vet. zootec ; 68(4): 845-852, jul.-ago. 2016. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: lil-792487

RESUMO

The first three jets of the sperm-rich fraction of Pêga jackasses were collected and assessed separately. Five fertile Pêga jackasses were used as semen donors and underwent fractionated semen collection, using an open model artificial vagina. The first three jets of the semen were collected separately and assessed for volume, sperm motility, vigor, concentration/mL of semen, and sperm morphology. These characteristics were compared between first, second and third jets and between jackasses. It was observed that the jet volume differed (P<0.05) between jackasses, although it was similar (P>0.05) between first, second and third jets. Sperm motility did not differ (P>0.05) between jets and jackasses. Vigor was similar (P>0.05) between jets of the same jackass, and only the first jet differed (P<0.05) between jackasses. The first, second and third jets of the sperm-rich fraction had decreased sperm concentrations (P<0.05) of 955.56, 725.56 and 280.56x 106 sperm/mL of semen, respectively. Sperm morphology differed between the first three jets only for the incidence of mid-piece defect, higher in the third one (4.26%), compared to the first (3.36%) and second (3.38%) ones. When comparing the morphological characteristics of the sperm-rich fraction between five jackasses, regardless of the jet, there were differences in the percentage of normal sperm, proximal cytoplasmic droplet, mid-piece and head defects.(AU)


Objetivou-se, no presente experimento, caracterizar os três primeiros jatos da fração rica do ejaculado de jumentos da raça Pêga. Para tal, cinco jumentos foram submetidos à coleta fracionada do sêmen, utilizando-se vagina artificial modelo aberta. Os três primeiros jatos da fração rica do ejaculado foram coletados separadamente e avaliados quanto ao volume, à motilidade e ao vigor espermáticos, à concentração espermática/mL de sêmen e à morfologia espermática. Comparações foram realizadas entre jatos e entre jumentos. Observou-se que o volume do jato diferiu (P<0,05) entre os jumentos, embora fosse similar (P>0,05) entre os jatos. A motilidade espermática não diferiu (P>0,05) entre jatos nem entre jumentos. O vigor espermático foi similar (P>0,05) entre os jatos de um mesmo jumento, e apenas o vigor do jato 1 diferiu (P<0,05) entre os jumentos. Independentemente do jumento, a fração rica do ejaculado foi composta por três jatos apresentando concentrações espermáticas decrescentes (P<0,05), com 955,56; 725,56 e 280,56 x 106 espermatozoides/mL de sêmen. A morfologia espermática diferiu entre os três jatos avaliados apenas para a incidência de defeitos de peça intermediária, sendo maior no jato três (4,26%), em relação aos jatos um (3,36%) e dois (3,38%). Comparando-se as características morfológicas do sêmen entre os cinco jumentos avaliados, independentemente do jato, observaram-se diferenças entre os reprodutores quanto ao percentual de espermatozoides normais, com gota citoplasmática proximal, com defeitos de peça intermediária e de cabeça.(AU)


Assuntos
Animais , Masculino , Equidae , Análise do Sêmen/veterinária , Manejo de Espécimes/veterinária
2.
Ann Card Anaesth ; 2015 Oct; 18(4): 584-586
Artigo em Inglês | IMSEAR | ID: sea-165272

RESUMO

After mitral valve replacement with a prosthetic valve, the valve should be competent and there should not be any residual prosthetic valve regurgitation. Transvalvular residual prosthetic valve regurgitation are difficult to diagnose and quantify. we are reporting interesting TEE images as a diagnostic dilemma in a case of transvalvular mitral regurgitation following mitral valve replacement secondary to entrapment of sub-valvular apparatus in a Chitra mechanical heart valve.

3.
Eng. sanit. ambient ; 18(1): 9-14, jan.-mar. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-676953

RESUMO

A injeção de misturas de ar e água na forma de jatos bifásicos é bastante usada para a aeração artificial em tanques e corpos hídricos. No presente trabalho, foram realizados experimentos para investigar a transferência de massa induzida por estes jatos em um tanque de aeração. Os resultados forneceram eficiências de transferência de oxigênio padrão variando entre aproximadamente 5 e 9%. Combinando-se os dados obtidos nesta pesquisa com os disponíveis na literatura, foram geradas correlações adimensionais para o coeficiente de transferência de massa em função da fração volumétrica de ar e do número de Froude densimétrico. Finalmente, os resultados foram aplicados a situações práticas envolvendo sistemas de aeração por jatos bifásicos.


The injection of air-water mixtures through two-phase jets is widely used for artificial aeration in tanks and water bodies. In this study, experiments were conducted to investigate mass transfer induced by such jets in an aeration tank. The results provided standard oxygen transfer efficiencies ranging from about 5 to 9%. Combining the results obtained here with those from previous investigations allowed to generate dimensionless correlations for the mass transfer coefficient as a function of the gas volume fraction and the densimetric Froude number. Finally, the results were applied to practical situations involving two-phase jet aeration systems.

4.
Eng. sanit. ambient ; 15(1): 75-82, jan.-mar. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-545400

RESUMO

Jatos bifásicos do tipo gás-líquido são bastante usados nas engenharias sanitária e ambiental para fins de aeração artificial e mistura turbulenta. O presente trabalho investiga a turbulência gerada por meio desses jatos em um tanque de água, utilizando velocimetria por imagem de partículas. As condições experimentais incluíram jatos bifásicos com frações volumétricas de ar de até 70 por cento e números de Reynolds variando entre 10.600 e 17.700. Os resultados dos ensaios indicaram que a fração volumétrica de ar afeta consideravelmente as propriedades turbulentas da fase líquida, enquanto o número de Reynolds apresenta efeito secundário. Correlações adimensionais foram então obtidas para expressar a energia cinética turbulenta e a taxa de dissipação de energia em função desses dois parâmetros. Finalmente, são apresentadas possíveis aplicações dos resultados deste trabalho.


Two-phase gas-liquid jets are widely used in the sanitary and environmental engineering field for artificial aeration and turbulent mixing. The present work investigates the turbulence generated by these jets in a water tank, using particle image velocimetry. The experimental conditions included two-phase jets with gas volume fractions of up to 70 percent and Reynolds numbers ranging from 10,600 to 17,700. The results indicated that the gas volume fraction affects significantly the turbulent properties of the liquid phase, while the Reynolds number presents a secondary effect. Dimensionless correlations were then obtained to express the turbulent kinetic energy and dissipation rate as a function of these two parameters. Finally, possible applications of the results obtained in this work are presented.

SELEÇÃO DE REFERÊNCIAS