Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Biomédica (Bogotá) ; 43(3): 315-322, sept. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1533942

RESUMO

Introduction. Over time, efforts have been invested in the design of new instruments that overcome the disadvantages of the gold standard instrument in surgery, the scalpel. As a result, electronic equipment has emerged such as the electric scalpel and laser devices. The available evidence on these instruments suggests that the tissue response is related to each instrument's physical and biological cutting principles. Objective. To compare the histological changes in gingiva samples associated with surgical cutting performed with a 940 nm diode laser, a 2780 nm erbium, chromium: yttriumscandium-gallium-garnet (Er,Cr:YSGG) laser, and an electric scalpel, by presenting a series of cases. Case presentation. We present three cases of healthy patients undergoing cosmetic surgery. The clinical examination revealed exposure of a keratinized gingiva band greater than 4 mm, normal color and texture in gingival tissue, with a firm consistency and no bleeding on periodontal probing. Gingivectomy was indicated with the following protocols: Diode laser of 940 nm at 1 W, in continuous mode; Er,Cr:YSGG laser of 2780 nm at 2.5 W, 75 Hz, H mode, air 20, water 40, gold tip MT4); and electric scalpel in cutting mode at power level four. Gingival tissue samples were taken and stored in 10% formaldehyde for histological analysis. Conclusion. All the evaluated cutting instruments generated histological changes produced by the thermal effect, the main ones being collagen coagulation and carbonization. The depth of thermal damage caused by the 2780 nm Er,Cr:YSGG laser was much lesser than that induced by the electric scalpel and the 940 nm diode laser.


Introducción. Históricamente se ha invertido esfuerzo en el diseño de nuevos instrumentos que superen las desventajas del estándar de referencia en cirugía, el bisturí. Como consecuencia de esto, han surgido equipos electrónicos como el electrobisturí y los diferentes dispositivos de tecnología láser. La información disponible sobre estos instrumentos sugiere que la respuesta del tejido intervenido está influenciada por los principios físicos y biológicos de corte del instrumento. Objetivo. Comparar los cambios histológicos en muestras de encía asociados al corte quirúrgico realizado con láser de diodo de 940 nm, láser de erbio, cromo: itrio-escandio-galio-granate (Er,Cr:YSGG) (2780nm) y electrobisturí mediante una presentación de serie de casos. Presentación de los casos. Se presentan tres casos de pacientes sanos sometidos a cirugía estética. El examen clínico reveló la exposición de una banda gingival queratinizada mayor de 4 mm, tejido gingival de color y textura normales, de consistencia firme y sin sangrado al sondaje periodontal. Se indicó gingivectomía con los siguientes protocolos: láser de diodo de 940 nm a 1 W, en modo continuo; láser de Er,Cr:YSGG de 2780 nm a 2,5 W, 75 Hz, modo H, aire 20, agua 40, punta de oro MT4; y bisturí eléctrico en modo de corte, a nivel de potencia cuatro. Se tomaron muestras de tejido gingival y se almacenaron en formaldehído al 10 % para su análisis histológico. Conclusión. Los tres instrumentos de corte generaron cambios histológicos producidos por el efecto térmico; los principales fueron coagulación del colágeno y carbonización. La profundización del daño térmico causada por el láser de Er,Cr:YSGG de 2780 nm fue mucho menor que la generada por el electrobisturí y por el láser de diodo de 940 nm.


Assuntos
Gengivectomia , Artefatos , Lasers Semicondutores , Lasers de Estado Sólido , Histologia
2.
Rev. ADM ; 80(4): 190-196, jul.-ago. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1525858

RESUMO

Introducción: la adaptación marginal e interna de nuestras restauraciones fabricadas por fundición sistemas de fresado y sinterización láser es uno de los factores clínicos más importantes para el éxito de las prótesis fijas, previniendo el riesgo de microfiltración y enfermedad periodontal. Objetivo: evaluar la adaptación marginal e interna de cofias metálicas en aleación Cr-Co confeccionadas por técnicas convencionales, CAD/ CAM de fresado y sinterizado por láser. Material y métodos: estudio de tipo experimental, comparativo e in vitro. Se imprimió un modelo maestro en Cr-Co, proveniente del escaneo de un premolar preparado para corona completa, sobre el cual se diseñaron 30 cofias divididas en tres grupos: el primero que corresponde al grupo cofias fundidas fresadas en disco de cera A (A = 10), el segundo grupo cofias fresadas en disco de metal presinterizado B (B = 10) y el tercer grupo cofias impresas por sinterización láser C (C = 10). Se empleó la réplica de silicona, colocando silicona al interior de cada cofia, sobre el modelo maestro, simulando al cemento, mediante una máquina de ensayo universal se realizó una compresión de 50 N. Luego de retirar cada cofia se rellenaron con silicona pesada de adición, obteniendo una réplica de silicona. Se efectuaron dos cortes transversales en sentido vestíbulolingual y mesiodistal. Se observó el espesor de silicona VPS (vinil poliéter silicona) mediante un estereomicroscopio (Nikon SMZ745T), obteniendo valores en micrómetros. Para el análisis estadístico se utilizó el software SPSS 25 con el fin de realizar la prueba de normalidad y ANOVA de dos vías bajo un nivel de confianza del 95%. Resultados: el menor gap lo obtuvo el grupo de fresadas, seguido de las impresas y por último las fundidas por métodos convencionales. ANOVA de dos vías reveló diferencias estadísticamente significativas entre los tres grupos (p < 0.0001). Conclusiones: se encontró que el gap varía con cada método de fabricación, la técnica convencional de fundido mostró un mayor gap, ninguna excediendo el rango clínicamente aceptable (AU)


Introduction: the marginal and internal adaptation of our restorations manufactured by casting, milling systems and laser sintering is one of the most important clinical factors for the success of fixed prostheses, preventing the risk of microleakage and periodontal disease. Objective: evaluate the marginal and internal adaptation of metal copings in Cr-Co alloy made by conventional techniques, CAD/CAM milling and laser sintering. Material and methods: an experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown. An experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown, on which 30 caps divided into three groups were designed; the first group corresponds to the cast copings milled on a wax disc A (A = 10), the second group milled copings on a presintered metal disc B (B = 10) and the third group printed by laser sintering copings C (C = 10). The silicone replica was used, placing silicone inside each coping, on the master model, simulating cement, using a universal testing machine, a 50 N compression was performed. After removing each coping, they were filled with heavy addition silicone, obtaining a silicone replica. Two cross-sections were made in the buccolingual and mesiodistal direction., observing the thickness of the VPS (vinyl polyeter silicone) silicone using a stereomicroscope (Nikon SMZ745T), obtaining values in micrometers. For the statistical analysis, the SPSS 25 software was used in order to perform the normality and two-way ANOVA tests under a 95% confidence level. Results: the smallest gap was obtained by the milled group, followed by the printed ones and finally those cast by conventional methods. Two-way ANOVA revealed statistically significant differences between the three groups (p < 0.0001). Conclusions: the gap was found to vary with each fabrication method, the conventional casting technique showed a larger gap, none exceeding the clinically acceptable range (AU)


Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Adaptação Marginal Dentária , Coroas , Lasers , Técnicas In Vitro , Análise de Variância
3.
J. oral res. (Impresa) ; 11(6): 1-10, nov. 3, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1437657

RESUMO

Aim: To assess the effect of different mechanical surface treatments on flexural strength of repaired denture base. Material and Methods: Sixty bar-shaped specimens of heat-polymerized acrylic resin were fabricated, and divided into six groups (n=10). All specimens, except the positive control group (group PC), were sectioned into halves to create a 1-mm clearance. A negative control group with no surface treatment (group NC) was also considered. Other groups underwent different surface treatments: group Laser; treated with erbium: yttrium-aluminum-garnet (Er:YAG) laser, group APA; airborne-particle abrasion (APA), group APA plus Laser; a combination of laser and APA, and group Bur; bur grinding. After measuring surface roughness (Ra) with a profilometer, all sectioned specimens were repaired by auto-polymerizing acrylic resin, and thermocycled afterward. Three-point bending test was performed by a universal testing machine. Data were statistically analyzed (α=0.05). Results: The mean surface roughness of all experimental groups were significantly higher than that of group NC (p<0.05). The mean flexural strength of all groups was significantly lower than that of group PC (p<0.05). Group B had significantly higher flexural strength than the other surface-treated groups (p<0.05). Group Laser had significantly higher flexural strength than groups APA (p=0.043) and APA plus Laser (p=0.023). No significant difference was found between groups APA and APA plus Laser (p=0.684). Conclusion: All surface treatments increased the surface roughness and flexural strength compared with the untreated group. The highest flexural strength was observed in specimens treated by bur grinding and then laser, however, it was still significantly lower than intact specimens.


Objetivo: Evaluar el efecto de diferentes tratamientos superficiales mecánicos sobre la resistencia a la flexión de la base de la prótesis reparada. Material y Métodos: Se fabricaron sesenta especímenes en forma de barra de resina acrílica termo-polimerizada y se dividieron en seis grupos (n=10). Todas las muestras, excepto el grupo de control positivo (grupo PC), se seccionaron en mitades para crear un espacio libre de 1 mm. También se consideró un grupo de control negativo sin tratamiento superficial (grupo NC). Otros grupos se sometieron a diferentes tratamientos superficiales: grupo Láser; tratados con láser de erbio: itrio-aluminio-granate (Er:YAG), grupo APA; abrasión por partículas en el aire (APA), grupo APA más láser; una combinación de láser y APA, y grupo Bur; molienda de fresas. Después de medir la rugosidad de la superficie (Ra) con un perfilómetro, todas las muestras seccionadas se repararon con resina acrílica de autopolimerización y se sometieron a termociclado. La prueba de flexión de tres puntos se realizó con una máquina de prueba universal. Los datos se analizaron estadísticamente (α=0,05). Resultados: La rugosidad superficial media de todos los grupos experimentales fue significativamente mayor que la del grupo NC (p<0,05). La resistencia media a la flexión de todos los grupos fue significativamente menor que la del grupo PC (p<0,05). El grupo B tenía una resistencia a la flexión significativamente mayor que los otros grupos tratados en la superficie (p<0,05). El grupo Láser tuvo una resistencia a la flexión significativamente mayor que los grupos APA (p=0,043) y APA más Láser (p=0,023). No se encontró diferencia significativa entre los grupos APA y APA más Láser (p=0,684). Conclusión: Todos los tratamientos superficiales aumentan la rugosidad de la superficie y la resistencia a la flexión en comparación con el grupo sin tratar. La resistencia a la flexión más alta se observó en las muestras tratadas con fresado y luego con láser; sin embargo, aún era significativamente más baja que las muestras intactas.


Assuntos
Humanos , Resinas Acrílicas/química , Reparação em Dentadura , Polimetil Metacrilato/química , Materiais Dentários/química , Bases de Dentadura , Lasers de Estado Sólido , Metacrilatos/química
4.
Rev. estomatol. Hered ; 30(3): 153-163, jul-sep 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1180912

RESUMO

RESUMEN La técnica de cera perdida colada por centrifugación por inducción (CPCI) y fusión selectiva láser (SLM) en diseño y fabricación asistida por computador (CAD/CAM) con escaneo clínico, son técnicas para fabricar cofias de Cobalto-Cromo (Co-Cr), poseen diferentes procesos de elaboración. Objetivo: Evaluar in vitro la adaptación marginal e interna de cofias metálicas de Co-Cr confeccionadas sobre una línea de terminación chámfer con la técnica CPCI y SLM en CAD/CAM con escaneo clínico. Material y Métodos: Se confeccionó un modelo maestro de forma de premolar de Co-Cr en CAD/CAM con línea de terminación chamfer. Con un escáner clínico se escaneó el modelo maestro y se obtuvo 13 cofias Co-Cr fabricadas en SLM. Se tomaron impresiones para obtener modelos en yeso tipo IV donde se fabricaron 13 cofias de Co-Cr con técnica CPCI. La adaptación marginal e interna se evaluó usando la técnica de réplica de silicona, las muestras fueron divididas en segmentos: vestíbulo-palatino y mesio-distal y fueron evaluadas mediante estéreomicroscopio. Resultados: La discrepancia marginal e interna fueron menores para el grupo de CPCI en comparación a la técnica SLM en CAD/CAM con escaneo clínico. Además los resultados obtenidos para la adaptación marginal fueron menores a 120 μm y la adaptación interna menor a 350 μm para ambas técnicas. Conclusiones: La adaptación marginal e interna en la técnica CPCI en comparación con SLM en CAD/CAM con escaneo clínico fueron mejores con diferencia estadísticamente significativa (p<0.05). Además los resultados obtenidos se encontraban dentro de los parámetros clínicamente aceptables.


SUMMARY The technique of lost wax cast by induction centrifugation (CPCI) and selective laser fusion (SLM) in design and computer-aided manufacturing (CAD / CAM) with clinical scanning, are techniques for manufacturing cobalt-chromium copings (Co-Cr), have different production processes. Objective: To evaluate, in vitro, the marginal and internal adaptation of Co-Cr metal copings made on a chamfer termination line with the CPCI and SLM technique in CAD / CAM with clinical scanning. Material and Methods: A master model of Co-Cr premolar shape was made in CAD / CAM with chamfer termination line. With a clinical scanner, the master model was scanned and 13 Co-Cr copings manufactured in SLM were obtained. Impressions were taken to obtain models in type IV plaster where 13 Co-Cr copings with CPCI technique were manufactured. The marginal and internal adaptation was evaluated using the silicone replica technique, the samples were divided into segments: vestibulo-palatal and mesio-distal and were evaluated by stereo microscope. Results: The marginal and internal discrepancies were lower for the CPCI group compared to the SLM technique in CAD / CAM with clinical scanning. In addition, the results obtained for the marginal adaptation were less than 120 μm and the internal adaptation less than 350 μm for both techniques. Conclusions: The marginal and internal adaptation in the CPCI technique compared to SLM in CAD/CAM with clinical scan were better with statistically significant difference (p <0.05). In addition, the results obtained were within the clinically acceptable paramenters.

5.
Rev. estomatol. Hered ; 30(3): 164-175, jul-sep 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1180913

RESUMO

RESUMEN Existen pocos estudios que comparen la adaptación de cofias de Cobalto-Cromo (Co-Cr) fabricadas por la técnica de cera perdida colada por centrifugación por inducción (CPCI) y fusión selectiva láser (SLM) en diseño y fabricación asistida por computador (CAD/CAM). Objetivo: Evaluar in vitro la adaptación marginal e interna de cofias unitarias de aleación Co-Cr sobre una línea de terminación tipo chamfer, fabricadas con la técnica CPCI y SLM en CAD/CAM. Material y Métodos: Se fabricaron 13 cofias de aleación Co-Cr para cada técnica. Se evaluó la adaptación marginal e interna utilizando la técnica de réplica de silicona. Cada réplica fue seccionada en sentido vestíbulo-palatino y mesio-distal para luego ser analizadas a nivel cervical, axial y oclusal mediante un estéreomicroscopio con aumento de 40X. Resultados: La discrepancia marginal de las cofias Co- Cr fabricadas por la técnica SLM fue 38.1μm y para la técnica CPCI fue 42,22μm sin diferencias significativas (p>0,05). La discrepancia axial para las cofias fabricadas por técnica CPCI fue de 42,02μm y para la técnica SLM de 60,16μm con diferencia significativa (p<0.05). La discrepancia oclusal para las cofias confeccionadas por la técnica CPCI fue de 101,94 μm y para la técnica SLM fue de 232,13μm con diferencia significativa (p<0,05). Conclusiones: La adaptación marginal fue similar para las técnicas CPCI y SLM pero sin diferencias estadísticamente significativas. La adaptación interna fue mejor para la técnica CPCI que para la técnica SLM con diferencias estadísticamente significativas.


SUMMARY There are few studies comparing the fit of cobalt-chromium copings (Co-Cr) manufactured by induction centrifugal casting technique and selective laser melting (SLM) in CAD/CAM. Objective: The purpose of this study was to evaluate in vitro the marginal and internal fit of Co-Cr alloy unit copings on a chamfer termination line manufactured by induction centrifugal casting technique (CPCI) and selective laser melting (SLM) in CAD/CAM. Material and methods: Thirteen Co-Cr unit copings were made for each technique. Marginal and internal fit were evaluated with the replica technique. Each sample was cross sectioned in the vestibular-palatine and mesio-distal direction, then observed in a stereomicroscope at a 40X magnification and measured at the cervical, axial and occlusal areas. Results: The marginal discrepancy of Co-Cr copings manufactured by the SLM technique was 38.1 μm and for the CPCI technique it was 42.22 μm without significant differences (p > 0.05). The axial discrepancy for the copings manufactured by CPCI technique was 42.02 μm and for the SLM technique of 60.16 μm with significant difference (P < 0.05). The occlusal discrepancy for the copings made by the CPCI technique was 101.94 μm and for the SLM technique was 232.13 μm with significant difference (P < 0.05). Conclusions: The marginal adaptation was similar for CPCI and SLM techniques but without statistically significant differences. The internal adaptation was better for the CPCI technique than for the SLM technique with statistically significant differences.

6.
Rev. estomatol. Hered ; 28(1): 7-19, ene. 2018. ilus, tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1014001

RESUMO

Nuevas tecnologías nos han permitido migrar de la técnica de cera perdida colada por centrifugado (CPC) a la fabricación aditiva como la fusión selectiva por láser (SLM), proporcionando una mejor adaptación marginal e interna. Objetivos: Comparar la discrepancia marginal e interna en cofias unitarias de Co-Cr sobre 2 líneas de terminación: chamfer y bisel, fabricadas con la CPC y SLM, determinando cual tuvo mejor adaptación marginal e interna. Material y Métodos: Se tuvo 4 grupos de estudio: CPC chamfer (n=13), CPC bisel (n=13), SLM chamfer (n=13) y SLM bisel (n=13). Para evaluar la discrepancia marginal e interna se usó el método de la réplica en silicona, seccionando primero en sentido vestíbulo-palatino (V-P) y segundo en sentido mesio-distal (M-D). Se midió las zonas cervical, axial y oclusal con un estéreo microscopio a 40X. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk, y el análisis estadístico fue con las pruebas t de Student y U Mann-Whitney. La menor discrepancia marginal fue para la SLM chamfer con promedios menores de 24,70±10,29 μm en el corte V-P y de 21,82±5,94 μm en el corte M-D, seguido por la SLM bisel en el corte V-P de 34,12±16,23 μm y en el corte M-D de 35,34±8,91 μm. La CPC bisel en el corte V-P fue de 27,17±21,11 μm y en el corte M-D de 47,91±16,77 μm y para la CPC chamfer en el corte V-P fue de 89,65±58,39 μm y en el corte M-D de 91,72±67,13 μm; la diferencia fue estadísticamente significativa solo para las cofias de SLM chamfer comparándolas con la CPC chamfer. En la discrepancia interna los valores en los 4 grupos no tuvieron diferencias estadísticas. Conclusiones: Según los valores, la mejor adaptación marginal fue para la SLM cham- fer, seguida por la SLM bisel, CPC bisel y la CPC chamfer. En cuanto a la adaptación interna, los valores no fueron concluyentes para decir que técnica fue mejor, pero se logró mejor adaptación en la zona axial que la zona oclusal.


New technologies have allowed us to migrate from the spin-wax casting technique (CPC) to additive manufacturing such as selective laser fusion (SLM), providing a better marginal and internal adaptation. Objectives: To compare the marginal and internal discrepancies in Co-Cr unit metal copings on two termination lines: chamfer and bevel, made with CPC and SLM, determining which technique had the best marginal and internal adaptation. Material and Methods: We had 4 study groups: CPC chamfer (n=13), CPC bevel (n=13), SLM chamfer (n=13), SLM bevel (n=13). To assess marginal and internal discrepancies, the silicone replica technique was used, a first sectioning was performed in the vestibular-palatine (V-P) and a secondin the mesio-distal (M-D) direction. The cervical, axial and occlusal zones were measured in a stereomicroscope at 40X. Results: Normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student's t test and U Mann-Whitney test. The less discrepancy marginal was for the SLM chamfer with mean values less than 24.70±10.29 μm in the V-P cut and 21.82±5.94 μm in the M-D cut, followed by the SLM bevel in the P-V cut of 34.12±16.23 μm and in the cut M-D of 35.34±8.91 μm. The CPC bevel in the V-P cut was 27.17±21.11 μm and in the M-D cut of 47.91±16.77 μm and for the CPC chamfer in the V-P cut was 89.65±58.39 μm and in the M-D cut of 91.72±67.13 μm; the difference was statistically significant only for SLM chamfer copings compared to the CPC chamfer. In the internal discrepancy values, no statistical differences were found among the 4 groups. Conclusions: Accord- ing to the descriptive values the best marginal fit was achieved with the SLM chamfer, followed by the SLM bevel, CPC bevel and CPC chamfer. Regarding internal adaptation, the descriptive values were not conclusive enough to decide which technique was better, but a better adaptation was achieved in the axial zone than in the occlusal zone.

7.
Rev. estomatol. Hered ; 27(2): 88-100, abr. 2017. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: biblio-991176

RESUMO

Una buena adaptación marginal disminuye la probabilidad de caries, enfermedad periodontal y fracaso de la restauración. La adaptación interna es el ajuste entre la superficie de la preparación y la superficie interna de la restauración, proporcionando retención. La aleación metálica más usada es la de níquel-cromo (Ni-Cr); sin embargo presenta limitaciones como reacciones alérgicas. La aleación cobalto-cromo (Co-Cr) es una alternativa por tener biocompatibilidad, resistencia mecánica, resistencia a la corrosión y costo aceptable. Las nuevas tecnologías digitalizadas han permitido migrar de la técnica de cera perdida colada por centrifugación (CPC) a la manufactura de fresado o a la fabricación aditiva, como el de fusión selectiva por láser (SLM). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPC y SLM, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se no hay espacio entre las palabras metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La SLM obtuvo una menor discrepancia marginal en comparación con la CPC encontrándose diferencias estadísticamente significativas (p<0,05) entre ambas técnicas. En cambio, al comparar la discrepancia interna no se encontraron diferencias estadísticas. Conclusiones: La mejor adaptación marginal fue para las cofias metálicas de SLM. En cuanto a la adaptación interna, los valores descriptivos no fueron concluyentes para decidir que técnica fue mejor.


A good marginal adaptation decreases the probability of caries, periodontal disease and failure of there storation. The internal adaptation is the adjustment between the preparation surface and the internal surface of the restoration, providing retention. The most commonly used metal alloy is nickel-chromium (Ni-Cr); how ever it has limitations such as allergic reactions. The cobalt-chromium alloy (Co-Cr) is an alternative to have biocompatibility, mechanical strength, corrosion resistance and acceptable cost. The new digitized technologies havea llowed to migrate from the technique of wax loss cast by centrifugation (CPC) to the manufacture of subtraction or additive manufacturing, such as selective laser melting (SLM). Objectives: To compare the marginal and internal discrepancies of Cobalt-Chromium alloy copings units (Co-Cr) on a chamfer termination line, made with two techniques: CPC and SLM, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: The normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student's t test and U Mann-Whitney test. The SLM had a smaller marginal discrepancy compared to CPC, with statistically significant differences (p <0.05) between both techniques. On the other hand, when comparing the internal discrepancy, no statistical differences were found. Conclusions: The best marginal adaptation was for metal fittings of SLM. As for the internal adaptation, the descriptive values were not conclusive to decide which technique was best.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA