1.
Arq. bras. oftalmol ; 87(2): e2021, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527833

RESUMO

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

2.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527847

RESUMO

ABSTRACT Purpose: To explore the therapeutic effects of orthokeratology lens combined with 0.01% atropine eye drops on juvenile myopia. Methods: A total of 340 patients with juvenile myopia (340 eyes) treated from 2018 to December 2020 were divided into the control group (170 cases with 170 eyes, orthokeratology lens) and observation group (170 cases with 170 eyes, orthokeratology lens combined with 0.01% atropine eye drops). The best-corrected distance visual acuity, best-corrected near visual acuity, diopter, axial length, amplitude of accommodation, bright pupil diameter, dark pupil diameter, tear-film lipid layer thickness, and tear break-up time were measured before treatment and after 1 year of treatment. The incidence of adverse reactions was observed. Results: Compared with the values before treatment, the spherical equivalent degree was significantly improved by 0.22 (0.06, 0.55) D and 0.40 (0.15, 0.72) D in the observation and control groups after the treatment, respectively (p<0.01). After the treatment, the axial length was significantly increased by (0.15 ± 0.12) mm and (0.24 ± 0.11) mm in the observation and control groups, respectively, (p<0.01). After the treatment, the amplitude of accommodation significantly declined in the observation group and was lower than that in the control group, whereas both bright and dark pupil diameters significantly increase and were larger than those in the control group (p<0.01). After the treatment, the tear-film lipid layer thickness and tear break-up time significantly declined in the two groups (p<0.01). Conclusions: Orthokeratology lens combined with 0.01% atropine eye drops can synergistically enhance the control effect on juvenile myopia with high safety.


RESUMO Objetivo: Explorar os efeitos terapêuticos das lentes de ortoceratologia combinados com colírio atropina 0,01% em miopia juvenil. Métodos: Um total de 340 pacientes com miopia juvenil (340 olhos) tratados entre 2018 e Dezembro de 2020 foram divididos em Grupo Controle (170 casos com 170 olhos, lentes de ortoceratologia) e Grupo Observação (170 casos com 170 olhos, lentes de ortoceratologia combinadas com colírio atropina 0,01%). A acuidade visual melhor corrigida para longe, acuidade visual melhor corrigida para perto, dioptria, comprimento axial, amplitude de acomodação, diâmetro da pupila brilhante, diâmetro da pupila escura, espessura da camada lipídica da película lacrimal e tempo de ruptura do rasgo foram medidos antes do tratamento e 1 ano depois. A incidência de reações adversas foi observada. Resultados: Antes do tratamento, o grau esférico equivalente foi significativamente melhorado em 0,22 (0,06, 0,55) D e 0,40 (0,15, 0,72) D respectivamente no Grupo Observação e no Grupo Controle após o tratamento (p<0,01). Após tratamento, o comprimento axial foi significativamente aumentado em (0,15 ± 0,12) mm e (0,24 ± 0,11) mm respectivamente nos Grupos Observação e controle (p<0,01), enquanto, no grupo de observação, a amplitude de acomodação diminuiu significativamente e foi inferior a do Grupo Controle, e o diâmetro da pupila brilhante e o diâmetro da pupila escura aumentaram significativamente e foram maiores do que os do Grupo Controle (p<0,01). A espessura da camada lipídica da película lacrimal e o tempo de ruptura do rasgo diminuíram significativamente nos dois grupos (p<0,01) após o tratamento. Conclusões: As lentes de ortoceratologia combinadas com colírio atropina 0,01% podem melhorar significativamente o efeito controle em miopia juvenil com elevada segurança.

3.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527817

RESUMO

ABSTRACT Keratoconus is a progressive disorder that manifests as a cone-like steepening of the central or paracentral inferior cornea and irregular stromal thinning. There is a gradual decrease in visual acuity due to corneal asymmetry, irregular astigmatism, and increased optical aberrations, consequently impacting the quality of life. Several procedures have been developed in an attempt to slow or reverse the progression. The Bader procedure, which includes a pattern of incisions around the circumference of the cornea and at the base of the protruding cone, is one such surgery. These incisions penetrate 70-90% of the cornea's depth. Its goal is to flatten the topography and reduce corneal asymmetry and irregular astigmatism. Though prior research found these to be highly promising, we report a patient who was given contact lenses to restore and maintain his vision while his corneal ectasia and thinning progressed over the following decade.


RESUMO O ceratocone é uma doença progressiva que se manifesta como uma elevação semelhante a um cone da cór­nea central ou paracentral inferior e é associada a uma re­dução irregular da espessura do estroma. Há uma diminuição gradual da acuidade visual devido à assimetria da córnea, ao astigmatismo irregular e a um aumento das aberrações ópticas, o que prejudica a qualidade de vida. Foram desenvolvidos vários procedimentos para tentar interromper ou mesmo reverter a evolução da doença. Um deles é o chamado procedimento de Bader, que inclui um padrão de incisões em volta da circunferência da córnea e na base do cone protuberante. Essas incisões penetram até 70%-90% da profundidade da córnea e têm o objetivo de achatar a topografia e diminuir a assimetria da córnea e o astigmatismo irregular. Embora essa técnica seja muito promissora, segundo um estudo anterior, aqui se apresenta o caso de um paciente no qual esses objetivos não foram atingidos. Esse paciente recebeu lentes de contato para restaurar e manter sua visão, enquanto sua ectasia corneana e a redução da espessura progrediram ao longo da década seguinte.

4.
Artigo | IMSEAR | ID: sea-221032

RESUMO

PURPOSE: To understand effect of Scleral lens on Keratoglobus cornea. CASE STUDY: Prospective Case Study METHOD: A 19-year old male diagnosed with RE Keratoglobus and LE Keratoconus was given a trial of Scleral contact lenses (Comfort- 15), to understand vision development and rehabilitation when no other corrective option was giving fruitful results for vision rehabilitation. Upon trial final lens was chosen with respect to comfort, vision improvement for distance and near and visual rehabilitation, and was dispensed lens with follow-up of 1-week, 1- month, 3-month & 6-months. RESULT: With final lens patient was comfortable with wearing hours of 10-12 hours comfortably with vision restoration to both eyes 6/6; N6 from RE 6/60 and LE 6/24; N10 both eyes. CONCLUSION: Scleral lenses have been proven to be better corrective option for keratoglobus and keratoconus.

5.
Arq. bras. oftalmol ; 86(1): 7-12, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1403471

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the efficacy of a new-generation hybrid contact lens for improving visual outcomes and vision-related quality-of-life performance in patients with keratoconus who had intolerance or treatment failure of conventional correction methods such as the use of soft silicone-hydrogel or rigid gas-permeable contact lenses. Methods: Twenty-eight patients with keratoconus (42 eyes) were enrolled in this prospective cross-sectional study. Airflex (Swisslens) lenses were fitted in the patients' eyes in accordance with the manufacturer's instruction. Ophthalmologic examinations, including manifest refraction, best-corrected distance visual acuity, slit-lamp biomicroscopy, and National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ-25) assessment, were performed at baseline and the 6-month visit. Results: An adequate fit was achieved in 39 eyes (92.9%) of 26 patients. Six eyes of 3 patients were excluded from the study owing to discontinuation of lens wearing. The mean age of the successful wearers was 20.3 ± 4.9 years. The mean best-corrected distance visual acuity was statistically significantly improved from 0.62 ± 0.30 to 0.11 ± 0.06 logMAR with the Airflex hybrid contact lenses (p<0.001). The mean overall composite NEI-VFQ-25 score statistically significantly increased with the Airflex hybrid contact lenses at the 6-month visit as compared with that at baseline (from 77.1 ± 16.3 to 90.9 ± 7.3, p=0.036). Statistically significantly better scores were obtained with the Airflex hybrid contact lenses in all the NEI-VFQ-25 subscale items (all p<0.05). No significant adverse effects were observed. Conclusions: New-generation hybrid contact lenses can be used as an effective alternative for correction of irregular astigmatism in patients with keratoconus who have intolerance or treatment failure of conventional methods. Significant improvement in vision-related quality-of-life in patients with keratoconus can be achieved with these lenses.


RESUMO Objetivo: Este estudo tem como objetivo avaliar a eficácia de lentes de contato híbridas de nova geração nos resultados visuais e na qualidade de vida relacionada à visão em pacientes com ceratocone com intolerância ou insucesso dos métodos de correção habituais, tais como lentes flexíveis de silicone-hidrogel ou rígidas permeáveis a gases. Métodos: Foram incluídos neste estudo transversal prospectivo 42 olhos de 28 pacientes com ceratocone. Uma lente Airflex (Swisslens) foi aplicada nos olhos de acordo com as instruções do fabricante. Um exame oftalmológico, incluindo refração manifesta, melhor acuidade visual corrigida para longe, biomicroscopia com lâmpada de fenda e a aplicação do National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25), foi realizado no início do estudo e na visita de 6 meses. Resultados: Foi possível obter um ajuste adequado em 39 olhos (92,9%) de 26 pacientes. Foram excluídos do estudo 6 olhos de 3 pacientes devido à cessação do uso de lentes. A idade média dos usuários bem-sucedidos era de 20,3 ± 4,9 anos. A média da melhor acuidade visual corrigida para longe foi melhorada estatisticamente de 0,62 ± 0,30 para 0,11 ± 0,06 logMAR com as lentes de contato híbridas Airflex (p<0,001). A pontuação média geral composta no questionário NEI-VFQ-25 aumentou de forma estatisticamente significativa com a lente de contato híbrida Airflex na visita de 6 meses, em comparação com a pontuação inicial (de 77,1 ± 16,3 para 90,9 ± 7,3, p=0,036). As lentes de contato híbridas Airflex apresentaram pontuações melhores com significância estatística em todos os itens das sub-escalas do NEI-VFQ-25 (todos com p<0,05). Nenhum efeito adverso significativo foi observado. Conclusões: Lentes de contato híbridas de nova ge ração podem ser usadas como uma alternativa eficaz para a correção do astigmatismo irregular em pacientes com ceratocone com intolerância ou insucesso dos métodos habituais. Com essas lentes, pode-se alcançar uma melhora significativa na qualidade de vida relacionada à visão em pacientes com ceratocone.


Assuntos
Humanos , Adolescente , Adulto Jovem , Adulto , Qualidade de Vida , Lentes de Contato , Estudos Transversais , Estudos Prospectivos
6.
Arq. bras. oftalmol ; 86(1): 38-45, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403477

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were used, and checked the results. Methods: Scleral contact lens fittings in a private clinic setting were prospectively analyzed in a sequential, non-randomized, and non-comparative manner. All the patients underwent a complete ophthalmic examination and had an indication for scleral lens use (Zenlens, Alden Optical). Results: Scleral fit was analyzed in 80 eyes of 45 patients. Regarding diagnosis, 72% of the patients had keratoconus; 12%, radial keratotomy; 5%, post-refractive surgery ectasia; 5%, dry eye; and 3%, high myopia. In 66 (82.5%) of the 80 eyes studied, parameters were modified when the lenses were ordered. The reasons that led to the modifications were apical touch or decreased sagittal height, increased sagittal height, cylindrical over-refraction, poor visual acuity, lens flexure, peripheral touch, 360° edge compression, horizontal edge compression, and vertical edge compression. Conclusion: In this study, the use of Zenlens scleral lenses was shown to be a promising corrective treatment for patients requiring the use of scleral lenses. Although the study suggests a learning curve, as many adjustments were allowed, the lens could be customized according to the patients' needs. This increased the success rates of fitting and wearing, and consequently, use of the lens became a great option for the visual rehabilitation of patients.


RESUMO Objetivo: Avaliar o processo de adaptação de uma lente escleral que permite vários ajustes de parâmetros durante os testes e após o período inicial do seu uso; verificar quais os ajustes foram necessários, quais foram os mais utilizados, as suas indicações, a frequência com que estes recursos foram utilizados, e avaliar os resultados das mudanças realizadas. Métodos: A adaptação da lente de contato escleral foi analisada prospectivamente, de forma sequencial, não aleatória e não comparativa. Todos os pacientes foram submetidos a um exame oftalmológico completo e tinham indicação para o uso de lentes esclerais. Foi utilizada a lente Zenlens (Alden Optical). Resultados: Foi analisada a adaptação de lentes de contato esclerais em 80 olhos de 45 pacientes. Quanto ao diagnóstico, 72% tinham ceratocone, 12% tinham sido submetidos a ceratotomia radial, 5% tinham ectasia pós-cirurgia refrativa, 5% tinham olho seco, e 3%, alta miopia. Em 66 dos 80 olhos estudados (82,5%), os parâmetros foram modificados quando as lentes foram encomendadas. As razões foram: toque apical ou diminuição da altura sagital, aumento da altura sagital, sobre-refração cilíndrica, baixa acuidade visual, flexão da lente, toque periférico, compressão da borda em 360° e compressão da borda horizontal e/ou vertical. Conclusão: O uso de lentes esclerais Zenlens demonstrou ser uma forma de correção muito promissora para os pacientes que requerem o uso de lentes esclerais. Embora o estudo sugira uma curva de aprendizagem, é possível personalizar as lentes de acordo com as necessidades de cada pacientes. Este fato melhora a adaptação e aumenta a chance de sucesso do uso.

7.
Chinese Journal of Experimental Ophthalmology ; (12): 598-602, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990887

RESUMO

Cataract extraction is often combined with the implantation of intraocular lens (IOL) with the diopter matching the operated eye to restore optimal visual function after surgery.However, there are often errors between the actual refractive power of the operated eye and the predicted value.One of the major causes of postoperative refractive error is the change in IOL position compared with the expected position.In order to improve the accuracy of postoperative refraction prediction, Holladay proposed to introduce the concept of effective lens position (ELP) into the IOL diopter calculation formula.The differences in the parameters and algorithms incorporated in the calculation of ELP lead to differences in the accuracy of IOL calculation formulas.With the application of multi-parameter calculation methods, especially the formula based on the artificial intelligence algorithm, the accuracy of IOL calculation formula has been significantly improved.ELP is also affected by various factors such as differences in ocular anatomy, IOL design and material, and surgical procedures, especially the factors affecting the stability of the capsular bag that increase the difficulty of accurately predicting ELP.Therefore, the changes in postoperative ELP need to be further discussed in order to obtain more accurate postoperative refraction.This article aimed to give a review of the development of calculation formulas and the influencing factors of ELP.

8.
Chinese Journal of Experimental Ophthalmology ; (12): 576-581, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990884

RESUMO

Objective:To systematically compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with shallow anterior chamber.Methods:A comprehensive literature search was conducted in MEDLINE, EMBASE, Cochrane Library, and the Chinese databases including CNKI, Wanfang, and VIP databases.The peer-reviewed literature on the accuracy of IOL power calculation formulas in cataract patients with shallow anterior chamber was searched from the establishment of the database until August 2020.Literature screening, data extraction and quality assessment were performed according to inclusion and exclusion criteria.The mean difference ( MD) of mean absolute error (MAE) among different formulas was analyzed.Meta-analysis was performed using Revman 5.3 software. Results:Seven studies involving 499 eyes were included.The accuracy of six formulas, Barrett Universal Ⅱ, Haigis, SRK/T, Hoffer Q, Holladay 1 and Holladay 2, was evaluated.The MAE of Barrett Universal Ⅱ was significantly lower than that of Hoffer Q ( MD=0.11 D; 95% CI: 0.05-0.17 D; P<0.001), Haigis ( MD=0.08 D; 95% CI: 0.03-0.13 D; P=0.002), and Holladay 2 ( MD=-0.06 D; 95% CI: -0.11--0.01 D; P=0.020). No significant difference was found in the remaining pairwise comparisons (all at P>0.05). Conclusions:The Barrett Universal Ⅱ formula is more accurate than Hoffer Q, Haigis, and Holladay 2 formulas in predicting IOL power in cataract patients with shallow anterior chamber.

9.
Chinese Journal of Experimental Ophthalmology ; (12): 561-567, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990882

RESUMO

Objective:To observe the unfolding status of foldable acrylic intraocular lens (IOL) of different materials, designs and refractive powers implanted in the capsular bag during cataract surgery, and to investigate its influence on the IOL implantation procedure.Methods:An observational case series study was conducted.A total of 1 005 patients who underwent routine phacoemulsification and IOL implantation in Shaanxi Eye Hospital from February to August 2021 were enrolled.The status and unfolding time of the leading haptic, optical region, and trailing haptic of the IOL in the capsular bag and the surgeon were recorded in real-time intraoperative video.Of the 1 005 IOL implants, 681 were hydrophobic, 324 hydrophilic, 733 C-loop, 272 plate-haptic, 909 single-piece, 96 three-piece, 620 preloaded, and 385 non-preloaded.The differences in unconventional implantation factors and IOL unfolding time were compared.The factors influencing IOL implantation status were analyzed by multivariate logistic regression.Multivariate logistic regression was used to analyze the relevant factors affecting IOL implantation status.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Xi'an People's Hospital (Xi'an Fourth Hospital)(No.20200035). Written informed consent was obtained from each subject.Results:There were 14(1.4%) IOLs with unconventional leading haptic status during implantation, including 7 recurved, 4 folded, 2 twisted and 1 straightened.There were 101(10.0%) IOLs with unconventional trailing haptic status during implantation, including 49 stuck in the injector, 40 folded, 10 recurved and 2 broken.There were 22(2.2%) IOLs with overlapped leading and trailing haptic requiring additional separation.There were 4(0.4%) IOLs with reversed optical regions and 2(0.2%) with damaged optical regions.The occurrence rate of unconventional leading haptic status using C-loop IOL was higher than that using plate IOL, and the difference was statistically significant ( P<0.05). The occurrence rate of unconventional trailing haptic status using hydrophilic, non-preloaded, three-piece, and C-loop IOL was higher than that using hydrophobic, preloaded, single-piece, and plate IOL, respectively, and the differences were statistically significant ( χ2=9.100, 61.400, 81.885, 7.587; all at P<0.05). The 22(2.2%) IOLs with overlapped leading and trailing haptic were hydrophobic.The 4 (0.4%) IOLs with reversed optical region were non-preloaded.The results of multivariate logistic regression analysis showed that IOL material, loading method, design and surgeons were related to the unconventional trailing haptic status in implantation ( OR=9.894, 3.720, 6.810, 1.338; all at P<0.05). The average unfolding time of hydrophobic IOL was 26.12(21.21, 30.91)s, which was significantly longer than 3.03(2.16, 4.49)s of hydrophilic IOL ( Z=-25.603, P<0.05). The average unfolding time of C-loop IOL was 25.53(19.41, 30.25)s, which was significantly longer than 2.70(2.08, 3.69) s of plate IOL ( Z=-23.764, P<0.05). Conclusions:A variety of unconventional statuses of IOL can occur during implantation into the lens capsular bag.The use of hydrophobic, preloaded, single-piece, and plate IOLs can reduce the occurrence of unconventional status.The use of hydrophilic IOLs can reduce the overlap of leading and trailing haptic.The use of preloaded IOLs can reduce the occurrence of IOL optical region reversal.The use of hydrophilic and plate IOLs can shorten the operation time.

10.
Chinese Journal of Experimental Ophthalmology ; (12): 554-560, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990881

RESUMO

Objective:To evaluate the feasibility of measurement and characteristics of intraocular lens (IOL) tilt using the swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and to explore its potentially relevant parameters.Methods:A cross-sectional study was conducted.Two hundred and forty-two eyes (119 right eyes, 123 left eyes) of 185 patients after phacoemulsification and IOL implantation were included in Beijing Tongren Hospital from July to September 2018.The IOL position, angle κ, angle α, corneal curvature, anterior chamber depth (ACD), pupil diameter (PD), and axial length (AL) were obtained by IOLMaster 700, and the IOL tilt direction and magnitude were calculated.The within-subject standard deviation and intraclass correlation coefficient were used to evaluate the repeatability of three IOL tilt measurements.Binocular symmetry of IOL tilt and the correlation between IOL tilt and different influencing factors were evaluated by Pearson linear correlation analysis or Spearman rank correlation analysis.Influencing factors for IOL tilt were assessed by multiple linear regression analysis.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.TRECKY2018-049). Patients were informed of the purpose and methods of this study and signed the written informed consent.Results:The repeatability of IOL tilt measurements was excellent with a within-subject standard deviation of 5.16° for IOL tilt direction and 0.13° for IOL tilt magnitude.IOL tilt was mirror symmetric in both eyes.The IOL tilt direction in right eyes ranged from -89.60° to 87.53° with a mean of (18.85±29.65)°, and the tilt magnitude ranged from 1.32° to 7.05° with a mean of (4.16±1.26)°.The IOL tilt direction in left eyes ranged from -84.30° to 89.44° with a mean of (21.17±32.38)°, and the tilt magnitude ranged from 0.58° to 7.40° with a mean of (3.80±1.31)°.There were moderate and weak positive correlations of IOL tilt direction and tilt magnitude between both eyes ( r=0.473, P<0.001; r=0.335, P=0.011). IOL tilt magnitude was weakly positively correlated with angle α and IOL diopter ( rs=0.272, P=0.003; r=0.285, P=0.002), and was weakly negatively correlated with ACD, PD and AL ( r=-0.303, P=0.001; r=-0.233, P=0.011; rs=-0.331, P<0.001). In backward stepwise regression analysis, the regression equation of IOL tilt magnitude, angle α, ACD, PD, AL and IOL diopter in multiple linear regression analysis was as follows: IOL tilt magnitude=10.503+ 1.456×angle α-0.532×ACD-0.196×AL ( R2=0.400; F=8.588, P<0.001). Conclusions:The SS-OCT biometer can be an effective method to assess IOL tilt.IOL tilt is mirror symmetric between the right eyes and left eyes.

11.
Chinese Journal of Experimental Ophthalmology ; (12): 344-350, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990853

RESUMO

Objective:To investigate the influence of long-term wear of soft contact lenses on corneal transparency.Methods:A cross-sectional study was conducted.The corneal optical density of female myopic patients who planned to undergo corneal refractive surgery in Jinan Mingshui Eye Hospital from January 2018 to December 2020 was examined.The patients were divided into ≥2-<5 years group, ≥5-<10 years group, and ≥10 years group according to the duration of wearing contact lenses.Age- and sex-matched patients without wearing soft contact lenses were enrolled as a control group.There were 50 eyes from 50 cases in each group.The cornea was divided into 0-2, 2-6, 6-10, and 10-12 mm corneal vertex-centered annuli.The cornea over each annulus was divided into a superficial layer (≤120 μm from the outer surface of the cornea), a deep layer (≤60 μm from the inner surface of the cornea) and a central layer (between the superficial and deep layers). Measurements of the right eye were taken for analysis.The corneal optical density of different layers over different corneal ring regions was compared.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Jinan Mingshui Eye Hospital (No.2018-005). Written informed consent was obtained from each subject before any medical examination.Results:The corneal optical density tended to decrease as the wearing duration of corneal contact lens extended.The corneal optical density values of control group, ≥2-<5 years group, ≥5-<10 years group, and ≥10 years group were 18.51±1.79, 18.25±2.10, 18.16±1.89 and 17.83±1.65, respectively, showing no significant difference ( F=1.152, P=0.329). There was no significant difference in the corneal optical density of the superficial layer over 0-2, 2-6, and 6-10 mm annuli among the four groups ( F=2.077, 2.080, 2.229; all at P>0.05). There was a significant difference in the corneal optical density of the superficial layer over 10-12 mm annulus among the four groups ( F=5.016, P=0.002), and the corneal optical density of the superficial layer was greater in ≥5-<10 years group than in ≥2-<5 years, and greater in ≥10 years group than in control group, showing statistically significant differences (both at P<0.05). There were significant differences in the corneal optical density of the central layer over 0-2 and 6-10 mm annuli ( F=3.808, 2.813; both at P<0.05), and the corneal optical density of the central layer was lower in ≥10 years group than in control group, showing a statistically significant difference ( P<0.05). There were significant differences in the corneal optical density of the deep layer over 0-2, 2-6, 6-10 and 10-12 mm annuli ( F=5.485, 5.625, 3.398, 2.775; all at P<0.05). The optical density of the deep layer was lower in ≥5-<10 years than in control and ≥2-<5 years groups over 0-2, 2-6, and 10-12 mm annuli, lower in ≥5-<10 years group than in control group over the 6-10 annulus, and lower in ≥10 years group than in control group over 0-2, 2-6, and 6-10 mm annuli, and the differences were statistically significant (all at P<0.05). Conclusions:For women, the long-term wear of soft contact lenses for 5 years does not affect corneal transparency, and long-term wear for more than 5 years can cause a decrease in the transparency of the superficial peripheral cornea.

12.
International Eye Science ; (12): 187-192, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960933

RESUMO

AIM: To determine the students' satisfaction with the three teaching modes in the contact lens course and provide suggestions to improve teaching quality.METHODS: We conducted a survey at Tianjin Medical University in June 2021 using the Students' Evaluations of Educational Quality(SEEQ)questionnaire. We used descriptive statistics to analyze SEEQ items and the One-way ANOVA was used to determine differences in scores among the three modes.RESULTS: Among the 221 valid responses collected, 87(39.4%)respondents were males and 134(60.6%)were females. The total scores were 151.46(12.45), 148.71(13.14), and 147.97(14.56)for offline, online, and blended teaching, respectively, with no significant difference(F=1.10, P=0.33). Students had a longer interaction time with the teacher in offline teaching than in online and blended teaching(P=0.03). The three different teaching modes have no significant difference among genders or academic performance(P=0.33, P=0.91, respectively). Furthermore, 18.1% of students suggested that the amount of experiment time should be increased.CONCLUSION: Students were satisfied with all three teaching modes. However, they had more interaction time with teachers in traditional offline teaching compared with online and blended teaching. More time is needed to increase teachers' online teaching ability.

13.
International Eye Science ; (12): 1299-1304, 2023.
Artigo em Chinês | WPRIM | ID: wpr-978623

RESUMO

With the development of posterior chamber phakic intraocular lenses implantation and the constant improvement of the implantable collamer lens(ICL), ICL V4c implantation has become one of the main methods for correcting moderate and high myopia. Vault is an important indicator to evaluate the security of posterior chamber intraocular lens implantation. In recent years, optimizing surgical procedures to obtain the ideal vault in ICL V4c implantation surgery has become a research hotspot. This paper aims to provide help for improving surgical safety by summarizing and analyzing the optimized programs of ICL V4c implantation surgery. The focus will be on preoperative examination, intraoperative surgical design, and postoperative follow-up.

14.
Mongolian Medical Sciences ; : 17-21, 2023.
Artigo em Inglês | WPRIM | ID: wpr-972364

RESUMO

Introduction@#Intraocular lens (IOL) implants are monofocal and trifocal lenses which helps to clear up the vision after cataract surgery.@*Goal@#In this work, we aimed to compare the monofocal and trifocal IOL implantation during phacoemulsification surgery.@*Materials and Methods@#This study was conducted on 133 participants. Females comprised n=81, mean n=52 into equal groups. Preoperative and Postoperative cataract surgery UCVA and BCVA were measured and compared during the after 1 day, week 1, 2 weeks and month1. @*Statistical analysis@#The results of the study were processed using the SPSS 25.0 program after coding the data and checking for typographical errors. The normality of the data distribution was tested by inspecting a histogram. Categorical variables were compared using the chi-square test or Fisher's test. Statistical significance was determined at a p-value lower than 0.05@*Ethical statement@#The study was approved by the Research Ethics Committee of the Mongolian National University of Medical Sciences (No.2021/05/21). All patients provided written informed consent before participating in this study.@*Results@#The mean preoperative UCVA was 1.09±0.45D in monofocal IOL group, 0.99±0.49D in trifocal IOL group. At the first week: The mean postoperative UCVA at one week was 0.34±0.29D and 0.27±0.17D, in each group respectively. The mean postoperative BCVA in the first week was 0.28±0.27D and 0.20±0.15D in each group respectively. The mean postoperative UCVA at 1 month was 0.27±0.24D and 0.15±0.16D in each group, while BCVA was 0.26±24.94D and 0.06±0.63D.There was a highly significant statistical difference between the result of UCVA preoperative and the results of UCVA at the early and last postoperative follow up. @*Conclusion@#From our results, the best corrected visual acuity and was better for Trifocal group than Monofocal group. It is evident that post-operative near UCVA and BCVA was statistically significant at monofocal and trifocal groups.

15.
Chinese Journal of Medical Instrumentation ; (6): 93-98, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971311

RESUMO

Three different preclinical evaluation methods of MTF through-frequency response, MTF through-focus-response and expected visual acuity were used to compare and analyze the imaging differences of IOLs with four different optical designs. The research work could be used in the simultaneous vision IOLs in the optical design stage and verify the optical quality of the IOLs, the results can predict the visual representation of the patients better. The evaluation results can provide reference for IOL manufacturers and users in product design, development, validation and application selection.


Assuntos
Humanos , Desenho de Prótese , Lentes Intraoculares , Visão Ocular , Acuidade Visual
16.
Arq. bras. oftalmol ; 86(5): e20230060, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513684

RESUMO

ABSTRACT A 38-year-old patient who developed aphakia and aniridia secondary to trauma suffered from vision loss. To improve her vision, an iris-intraocular lens complex (Reper®) was fixed to the sclera with Canabrava's double-flanged technique. There was a satisfactory increase in the patient's visual acuity and no complications were observed during the 6-months follow-up. Canabrava technique simplifies and improves the fixation of the iris-intraocular lens complex to the sclera. It is a safe option that does not require scleral flaps or knots.


RESUMO Uma paciente de 38 anos desenvolveu afacia e ani­ridia secundárias a um trauma, levando à perda da visão. Para melhorar sua visão, um complexo de íris e lente intraocular (Reper®) foi fixado à esclera com a técnica de flange duplo de Canabrava. Houve um aumento satisfatório na acuidade visual do paciente e nenhuma complicação foi observada durante o acompanhamento de 6 meses. A técnica de Canabrava simplifica e melhora a fixação do complexo de íris e lente intraocular na esclera. É uma opção segura que não requer retalhos ou pontos esclerais.

17.
Indian J Ophthalmol ; 2022 Oct; 70(10): 3690-3692
Artigo | IMSEAR | ID: sea-224641

RESUMO

The ophthalmic lenses that come in contact with the eyes pose a high risk for the transmission of bacterial and viral infections in eye clinics. Disinfecting these lenses does not happen stringently in a busy practice. We describe a novel method of disinfecting ophthalmic contact lenses using a semiautomated lens disinfector equipment, semiautomated lens disinfector. The equipment has motors to pump in and pump out water and disinfecting solution into a reservoir bath. The used ophthalmic lenses will be placed in a tray that partially dips into the bath for disinfection. Microbiology tests that were done to check the quality of the disinfection cycle showed good outcomes. Disinfection of ophthalmic contact lenses with the new equipment appeared to effectively eliminate contaminant microorganisms. This equipment can be used in busy ophthalmic clinics to alleviate the chances of cross-infection.

18.
Rev. sanid. mil ; 76(3): e04, jul.-sep. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1432132

RESUMO

Resumen Objetivo: Revisar en la literatura las diferentes posturas de las agencias reguladoras de la aviación sobre la implantación de lentes intraoculares multifocales (MIOLs) en pilotos aviadores civiles que han desarrollado catarata, además de evidencia científica que podría generar una revisión de los lineamientos vigentes. Resultados: Se encontraron el 50% (3 de 6) de agencias revisadas con postura en contra de los MIOLs. Además, se revisaron dos estudios a favor de los MIOLs, en el que implantarlos brinda una mayor independencia de lentes respecto a los monofocales para las tareas visuales dentro y fuera de la cabina, así como un rendimiento sin diferencias en simuladores de vuelo versus los pilotos con lentes intraoculares monofocales. Limitaciones: Existen pocos estudios de MIOLs en pilotos aviadores. Originalidad: No se ha reportado ninguna revisión de las agencias reguladoras respecto a la prohibición o permisión de los MIOLs en pilotos aviadores, tocando evidencia que pudiera consolidar una postura unánime respecto a este tema, como en su momento fue la cirugía refractiva con láser excimer que actualmente no está restringida.


Abstract Objective: To review the literature on the different stands of aviation regulatory agencies on the implantation of multifocal intraocular lenses (MIOLs) in civilian aviators who have developed cataract, as well as scientific evidence that could generate a revision of the current guidelines. Results: 50% (3 of 6) of agencies reviewed were found to be against MIOLs. In addition, two studies were reviewed in favour of MIOLs, in which implanting MIOLs provides greater lens independence from monofocals for visual tasks in and out of the cockpit, as well as no difference in performance in flight simulators versus pilots with monofocal intraocular lenses. Limitations: There are few studies of MIOLs in aviator pilots. Originality: No review of regulatory agencies regarding the prohibition or permission of MIOLs in airline pilots has been reported, touching on evidence that could consolidate a unanimous position on this issue, as was once the case with excimer laser refractive surgery, which is currently unrestricted.

19.
Arq. bras. oftalmol ; 85(3): 249-254, May-June 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383808

RESUMO

ABSTRACT Purpose: Creating models, in pediatric cataracts, to estimate kerotometry and axial length values at future ages, based on kerotometry and axial length measured at surgery, to estimate the intraocular lens power for emmetropia in future ages. Methods: Eyes with bilateral cataract and kerotometry and axial length measured at surgery and at least one postoperative examination with kerotometry and axial length measurements, were considered for this study. The models to estimate future kerotometry and axial length values were created considering (1) kerotometry and axial length measured at surgery, (2) the average slope of kerotometry and axial length logarithmic regression created for every single eye and (3) age at surgery. The intraocular lens for future ages can be estimated using these values in third generation formulas. The estimation errors for kerotometry, axial length and intraocular lens were also calculated. Results: A total of 57 eyes from 29 patients met the inclusion criteria. The average age at the surgery and follow-up was 36.96 ± 32.04 months and 2.39 ± 1.46 years, respectively. The average slope of logarithmic regression created for every single eye were -3.286 for kerotometry and +3.189 for axial length. The average absolute estimation errors for kerotometry and axial length were respectively: 0.61 ± 0.54 D and 0.49 ± 0.55 mm, and for intraocular lens using SRK-T, Hoffer-Q and Holladay I formulas were: 2 . 04 ± 1 . 73 D , 2 . 49 ± 2 . 10 D and 2 . 26 ± 1 . 87 D, respectively. Conclusions: The presented models could be used to estimate the intraocular lens power for emmetropia at future ages to guide the choice of the intraocular lens power to be implanted in pediatric cataract.


RESUMO Objetivo: Criar modelos, em catarata pediátrica, para estimar valores futuros de ceratometria e comprimento axial, com base na ceratometria e no comprimento axial medidos na cirurgia, para previsão do poder da lente intraocular para emetropia em idades futuras. Métodos: Olhos com catarata bilateral, ceratometria e comprimento axial medidos na cirurgia e pelo menos um exame pós-operatório com medidas de ceratometria e comprimento axial foram considerados para este estudo. Os modelos para estimar futuras ceratometrias e comprimentos axiais foram criados considerando (1) ceratometria e comprimento axial medidos na cirurgia, (2) a inclinação média da regressão logarítmica da ceratometria e comprimento axial criada para cada olho e (3) a idade na cirurgia. A lente intraocular para emetropia em idades futuras pode ser estimada usando esses valores em fórmulas de terceira geração. Os erros de estimativa da ceratometria, comprimento axial e poder da lente intraocular, usando os modelos, também foram calculados. Resultados: 57 olhos de 29 pacientes preencheram os critérios de inclusão. A idade média na cirurgia e acompanhamento foram de 36,96 ± 32,04 meses e 2,39 ± 1,46 anos, respectivamente. A inclinação média da regressão logarítmica criada para cada olho foi de -3.286 para ceratometria e + 3.189 para o comprimento axial. Os erros médios de estimativa absoluta para ceratometria e comprimento axial foram respectivamente: 0,61 ± 0,54 D e 0,49 ± 0,55 mm, e para o poder da lente intraocular usando as fórmulas SRK-T, Hoffer-Q e Holladay I foram: 2,04 ± 1,73 D, 2,49 ± 2,10 D e 2,26 ± 1,87 D, respectivamente. Conclusões: Os modelos apresentados podem ser utilizados para estimar o poder da lente intraocular que levaria a emetropia em idades futuras e orientar a escolha do poder da lente intraocular a ser implantada na catarata pediátrica.

20.
Artigo | IMSEAR | ID: sea-219940

RESUMO

Background: AS-OCT is a noncontact imaging device that provides the detailed structure of the anterior part of the eyes. The Objectives In this review, the author will discuss the clinical applications of AS-OCT in the scleral contact lens fittings.Material & Methods:Pre-Scleral lens fit and post fit ASOCT done on 30 patients to assess the normal fitting and compare it with the slit lamp evaluation.Results:ASOCT gives a Quantitative measurement of the fit.Conclusions:ASOCT comes out as a helpful tool for beginners particularly for a good assessment of a contact lens fit. The author also presents some interesting cases demonstrated via AS-OCT.