Korean Journal of Spine ; : 228-230, 2009.
Artigo em Inglês | WPRIM | ID: wpr-53619

RESUMO

Although the prediction of a delayed spinal cord injury after a low voltage electrical accident is difficult, we present a young paraplegic man who had delayed spinal cord injury after a low voltage electrical accident while working. Because the passage of an electric current is variable, the tissues far distant from the point of entry may be damaged, including the spinal cord. Low voltage itself is not a safe.


Assuntos
Paraplegia , Medula Espinal , Traumatismos da Medula Espinal