Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Yonsei Medical Journal ; : 1505-1510, 2013.
Artigo em Inglês | WPRIM | ID: wpr-100946

RESUMO

PURPOSE: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). MATERIALS AND METHODS: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. RESULTS: The alignment of the lower extremity improved from a mean of 11.4+/-6.7degrees (-10.3-34.4degrees) of varus preop. to 0.7+/-3.5degrees (-5.2-8.6degrees) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3+/-2.3degrees (83.4-97.2degrees) postop. and mean alignment of the tibial component was 90.4+/-2.2degrees (85.1-94.2degrees) postop. CONCLUSION: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.


Assuntos
Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA