Rev. chil. cir ; 66(3): 254-258, jun. 2014. ilus
Artigo em Espanhol | LILACS | ID: lil-708784

RESUMO

Background: The selection of the biomaterial to be used for reconstruction of orbital floor fractures depends on several factors such as the size of the defect, walls involved, internal contours, restoration of appropriate volume, elapsed time of the trauma and surgeon's experience. A treatment option is the use of Marlex® mesh. Case report: We report an 18 years old male victim of physical aggression, referred to the emergency service, with an orbital floor trauma. Marlex® mesh was used for reconstruction of the defect. Postoperative clinical assessment and CT scans performed at 30 and 180 days, showed full functional recovery.


Introducción: La selección del material biológico que se utilizará para la reconstrucción de las fracturas del suelo de órbita se relaciona con varios factores como: el tamaño del defecto, las paredes que participan, la adaptación de los contornos internos, la restauración del volumen adecuado, el tiempo transcurrido del trauma y la experiencia del cirujano. Una opción de tratamiento es el uso de la malla de Marlex® para la reconstrucción de defectos de suelo de la órbita. Caso clínico: El presente estudio reporta un caso de paciente de sexo masculino, 18 años, llevado a la sala de urgencias del Hospital da Cidade de Passo Fundo-RS, Brasil, víctima de una agresión física, presentando traumatismo de piso de órbita en que se utilizó para la reconstrucción una malla Marlex®. El control post-operatorio clínico y la tomografía de 30 y 180 días mostraron una función totalmente restaurada.


Assuntos
Humanos , Masculino , Adolescente , Fraturas Orbitárias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Telas Cirúrgicas , Diplopia/etiologia , Resultado do Tratamento
2.
Rev. AMRIGS ; 52(1): 34-37, jan.-mar. 2008. ilus
Artigo em Português | LILACS | ID: biblio-859526

RESUMO

Objetivos: Computar o resultado obtido em 24 pacientes submetidos à correção cirúrgica de pectus escavatum(PEX) pela técnica convencional no Serviço de Cirurgia Torácica da Universidade Luterana do Brasil. Método: Os prontuários de 24 pacientes, em sua maioria homens jovens, submetidos à correção cirúrgica de PEX no período de 5 anos foram revisados. A indicação cirúrgica foi o motivo estético que levou o paciente a consultar. A técnica cirúrgica consistiu em incisão transversal, retirada de 5 cartilagens bilateralmente, fratura da tábua anterior do esterno, suporte com tela de márlex e fechamento. Indicação, técnica, complicações e resultados foram computados. O tempo médio de internação e retorno às atividades foram de 3 e 7 dias, respectivamente. Resultados: Dos 24 pacientes, 23 tinham PEX simétrico e 1 era um caso de reoperação. Houve 3 complica- ções: 1 hemotórax residual, um hematoma de subcutâneo e, em 1 caso, houve recidiva após 5 anos, o qual teve de ser reoperado. O resultado final, do ponto de vista de satisfa- ção, foi considerado pelos 24 pacientes ótimo ou muito bom. Conclusão: A cirurgia para correção de PEX utilizando a técnica convencional apresenta resultados satisfatórios (AU)


Objectives: Data analysis of 24 patients submitted to surgical Pectus Escavatum (PEX) correction through the conventional procedure at the ULBRA Thoracic Surgery Service. Methods: The records of 24 patients submitted to surgical correction of PEX were revised through a 5-year period. Majority of them were male and young. The procedure was carried on through a transversal incision, bilateral withdrawal of 5 cartilages, fracture of the anterior board of the sternum, sustained with marlex mesh and closing. Indication, complications and results were reviewed. The mean hospitalization time was 3 days. The mean time to complete recovery and return to the usual activities was 7 days. Results: Twenty three patients had a symmetric PEX and 1 was a re-intervention. There were 3 patients with complications, a residual hemothorax, a subcutaneous hematoma and a recurrence after 5 years, which was re-operated. The patient satisfaction on the final results was graded in excellent or very good. Conclusion: The surgery for correction of PEX using the conventional procedure is safe and effective (AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Telas Cirúrgicas , Tórax em Funil/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Torácicos/métodos
3.
Rev. Col. Bras. Cir ; 29(2): 78-82, mar.-abr. 2002. ilus, tab
Artigo em Português | LILACS | ID: lil-496548

RESUMO

OBJETIVO: Relatar a experiência pessoal no tratamento cirúrgico de hérnias incisionais com a utilização da malha de polipropileno monofilamentar-márlex. MÉTODOS: Foram operados e seguidos 74 pacientes portadores de hérnia incisional originada de tratamento cirúrgico de diferentes afecções da cavidde abdominal, com idade entre 30 e 94 anos, sendo 39 do sexo feminino e 35 do sexo masculino. Destes 41,9 por cento foram submetidos a hernioplastia incisional pela primeira vez e 58,1 por cento já haviam tentado o tratamento sem sucesso. A técnica operatória usada foi a dissecção do saco herniário, ressecção da fibrose resultante de operações anteriores e fixação de tela de márlex substituindo ou reforçando a fáscia transversal por baixo dos músculos da parede abdominal. RESULTADO: 74 pacientes foram operados e seguidos de 1975 a 1995. Na última revisão, em maio de 1998, três pacientes haviam falecido, dois de doenças cardíacas e um de doença neoplasia. Apenas um paciente (1,3 por cento) apresentou recidiva, no início da experiência. Este foi reoperado e terve sua hérnia incisional curada. CONCLUSÃO: o uso da tela de márlex tecnicamente aplicada é o método ideal para a cura definitiva das hérnias incisionais.


BACKGROUND: Personal experience in the treatment of incisional hernia with the use of polypropylene monofilament mesh - marlex, is discussed. METHOD: Seventy-four patients, with ages ranging from 30 to 94 years (39 females and 35 males), with hernia secundary to surgical abdominal procedures, were studied. Half (41,9 percent) of these patients were submitted to surgical correction for the first time, however 58,1 percent were recurrences. Dissection of hernia sac, excision of old fibrosis and marlex mesh interposition were carried out to reinforce transversalis fascia under the muscles of the abdominal wall. RESULTS: Seventy-four patients were operated uppon from 1975 to 1995. Last follow-up carried out in 1998 disclosed three deaths not related to previous surgery. There was one recurrence (1,3 percent) at the beginning of our experience, which required second intervention. CONCLUSION: The use of marlex mesh interposition is a reliable method to correct incisional hernia providing adequate technique is utilized for its fixation.