Journal of Chinese Physician ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-521074

RESUMO

Objective To evaluate the application of fast-FLAIR T 2WI and enhanced fat-suppressed T 1WI in diagnosis of meningeal disorders.Methods Fast-FLAIR T 2WI and enhanced fat-suppressed T 1WI imaging for 38 patients with meningeal disorders were contrastingly studied.Results Meningeal disorders foci were found in all patients. 55 foci were displayed with fast-FLAIR T 2WI and 59 with enhanced fat-suppressed T 1WI.Conclusions The fast-FLAIR T 2WI and enhanced fat-suppressed T 1WI are all useful to improve the detection of meningeal disorders.