Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
STOMATOLOGY ; (12): 52-56, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965141

RESUMO

Objective@# To explore the effect of ultrasound on dentin smear layer's surface and bonding strength of the universal resin adhesive under self-etching mode. @*Methods@# Forty mandibular third molars without caries were randomly divided into two groups; one was polished with silicon carbide sandpaper; the other was polished with silicon carbide sandpaper followed by ultrasonic treatment. Scanning electron microscope (SEM) was used to observe surface of the dentin. Treated teeth were bonded with two universal resin adhesives, Clearfil Universal Bond (pH=2.3) and All-Bond Universal (pH=3.1), and the penetration of the bonding interface was observed with a confocal laser scanning microscope (CLSM) after Rhodamine B staining. Finally, the micro tensile bond strength test was conducted to test the adhesion. @*Results@# The SEM showed that after polishing with silicon carbide sandpaper, the smear layer of the dentin surface was scratched, and dentin tubules were almost completely blocked, with no obvious dentin tubules exposed. After ultrasonic treatment, the scratches were reduced, and a large number of dentin tubules were exposed. CLSM showed that both adhesives could penetrate the dentin along the dentin tubules more deeply after ultrasound treatment. Micro tensile bond strength tests showed that ultrasonic treatment could enhance the bonding strength of two universal resin adhesives. However, there was no statistical difference in bonding strength between these two universal resin adhesives under the same treatment. .@*Conclusion@# Ultrasound can partially remove the smear layer on dentin's surface, expose dentin tubules, and increase universal resin adhesives' penetration depth and bonding strength under self-etching mode

2.
Chinese Journal of Tissue Engineering Research ; (53): 517-523, 2020.
Artigo em Chinês | WPRIM | ID: wpr-848132

RESUMO

BACKGROUND: When the tooth surface is treated with a rotary or manual instrument, a smudge layer is formed on the enamel and dentin by debris generated by cutting and abrasion. The bonding interface between the adhesive and the dentin is considered as a weak part in the direct repair process. To clarify the effect of smear layer on different kinds of adhesive is significantly important for dentists to select and correctly use the adhesive in clinical treatment. OBJECTIVE: To evaluate the effect of different diamond burs on the dentin bonding performance of four adhesive systems to dentin after 24 hours and 100 days of artificial saliva-storage. METHODS: Adhesive systems were: (1) VSA (Optibond Versa, Kerr); (2) AIO (Optibond All in One, Kerr); (3) SBU (Single bond Universal, 3M); (4) GLU (Bond 5, Gluma, Heraeus). In present study, 80 extracted human molars were randomly divided into four groups and each group is divided into 4 subgroups. Dentin surfaces were prepared by: (1) 600-grit SiC-paper (control group); (2) super-fine diamond bur; (3) regular diamond bur; (4) coarse diamond bur. Bonding agent was applied according to each manufacturer’s instruction. After light-curing, dentin surfaces were built-up with resin composite (A2, CHARISMA, Heraeus). The micro-tensile bond strength was determined after 24 hours and 100 days of storage in artificial saliva at 37 °C. The fractured surfaces on dentin side were observed by scanning electron microscope. RESULTS AND CONCLUSION: (1) Storage for 24 hours: There was no significant difference among groups under VSA and GLU. Under SBU and AIO, the bond strength in the coarse diamond bur group was significantly lower than that in the control group (P 0. 05). Using coarse diamond bur, the bond strength in the VSA group had significant difference compared with the AIO, GLU and SBU groups (P 0. 05). (2) Storage for 100 days, there was no significant difference among groups under VSA and GLU. Under SBU, the bond strength in the coarse diamond bur group was significantly lower than that in the control group (P 0. 05). Using regular diamond bur, the bond strength showed no significant difference in the GLU group compared with the SBU, and VSA groups (P > 0. 05). Using coarse diamond bur, the bond strength had no significant difference between VSA and AIO groups (P < 0. 05). (3) Using VSA, the bond strength in each group at 100 days showed significant difference compared with that at 24 hours (P < 0. 05). (4)Compared with immersed for 24 hours, the ratio of bond interface and combined crack in the VSA, SBU and GLU groups after immersed for 100 days was increased, especially the VSA group. Compared with the other groups, the ratio of bond interface and combined crack in the GLU group after immersed for 24 hours and 100 days both increased by 50%. (5) These results indicate that preparation by different burs produces different smear layers, which has significant effect to self-etching adhesive system and has no significant effect to total-etching adhesive system. Storage time makes effect on different adhesives.

3.
Artigo | IMSEAR | ID: sea-192185

RESUMO

Objectives: The objective of the present study is to evaluate the bond strength of: (a) Zirconia blocks (tribochemical treatment and zirconia primer) and resin blocks bonded using self-adhesive resin cement (phosphate monomer cement). (b) Zirconia blocks and resin blocks bonded using nonphosphate monomer cement. (c) Micro-tensile bond strength of zirconia and resin blocks, bonded with self-adhesive resin cement and nonphosphate monomer cement after thermocycling. Materials and Methods: Twenty zirconium-dioxide specimens (5 mm × 5.4 mm × 13 mm) were produced using a metal mold. Each zirconium block was duplicated in light-curing resin material specimen (5 mm × 5.4 mm × 13 mm) using a mold made of addition silicon impression material. A total of 40 specimens were made, of which 20 specimens were zirconia blocks and 20 were resin blocks, which would be bonded to each other using phosphate monomer-containing cement (Multilink [10 nos.]) and nonphosphate monomer-containing cement (RELY-X [10 nos.]). The specimens were then divided into two groups of n = 10 each. The surface of zirconium specimen of one group (Group 1) was treated with zirconia primer and bonded with phosphate monomer-containing cement, and the other groups (Group 2) were not treated with any surface conditioning and were bonded with a nonphosphate containing cement. The specimens in each group were further subdivided into two subgroups of n = 5 each as follows: Group 1-1A (subjected to thermocycling), 1B (nonthermocycled) and Group 2-2A (subjected to thermocycling), 2B (nonthermocycled). Then, they were subjected for testing of tensile bond strength under a universal testing machine. Results: Resin cement selection seems to be a more relevant factor in the bonding of zirconia. The phosphate monomer-containing cement has the better bond strength after thermocycling compared to the nonphosphate monomer group. Thermocycling reduced the bond strength of both the groups and a significant difference was seen in the bond strength of nonphosphate monomer cement group subjected to thermocycling compared to the nonthermocycled one. Tensile bond strength values were significantly affected by the luting agent system employed and by thermal aging. Hence, for long-term durability, luting of zirconia with a phosphate monomer-containing cement after the zirconia has been surface treated is preferable as their bond strength did not show much significant difference after being subjected to thermocycling, compared to the nonthermocycled group. Conclusion: Resin cement selection seem to be a more relevent factor in the bonding of zirconia thermocycling does affect adhesion to to zirconium oxide ceramics.

4.
Rev. odontol. UNESP (Online) ; 48: e20180132, 2019. tab, ilus
Artigo em Português | LILACS, BBO | ID: biblio-991494

RESUMO

Resumo Introdução Os cimentos resinosos são extensivamente utilizados na fixação de restaurações indiretas de cerâmica e cerômero, sendo classificados em duas categorias: os cimentos resinosos convencionais, que não apresentam uma adesão inerente à estrutura dental e requerem o uso de um sistema adesivo e os cimentos resinosos autoadesivos, que não requerem um tratamento adesivo prévio do substrato dentário. Objetivo Avaliar a resistência de união de dois cimentos resinosos, convencional e autoadesivo, quando utilizados na cimentação de restaurações cerâmicas e ceroméricas, trazendo elementos para propiciar melhor compreensão da interação adesiva em procedimentos de cimentação com as referidas categorias de cimentos resinosos. Material e método Dentes humanos (n=20), cedidos pelo banco de dentes da Universidade Federal de Alfenas (UNIFAL), foram preparados para que cilindros de cerâmica ou de cerômero fossem cimentados utilizando-se dois tipos de cimentos resinosos (autoadesivo e convencional). Após a cimentação, 20 palitos foram obtidos e submetidos ao teste de tração, avaliando-se a força necessária para a fratura. Os valores obtidos foram submetidos à análise estatística empregando-se a análise de variância (ANOVA) e o teste de Tukey. Resultado As forças mínimas e máximas necessárias ao rompimento do cimento convencional foram superiores às mesmas requeridas para o rompimento da união promovida pelo cimento autoadesivo, bem como as medianas e as médias aritméticas, independentemente do material restaurador empregado. O teste de Tukey demonstrou que as diferenças entre os cimentos empregados são estatisticamente significantes, independentemente do material restaurador. Conclusão Os resultados deste trabalho sugerem que o material utilizado para a confecção dos corpos de prova (cerâmica ou cerômero) não influenciou na resistência à tração, sendo que o cimento convencional apresentou valores superiores de resistência.


Abstract Introduction Resin cements are extensively used in the fixation of indirect restorations of ceramics and ceramics, divided into two categories: conventional resin cements, which do not present an inherent adhesion to the dental structure and require the use of an adhesive system, and the self-adhesive resin cements, which do not require a prior adhesive treatment of the dental substrate. Objective: To evaluate the microtensile bond strength of two resin-based cements, conventional and self-adhesive, according to required operating protocols, when luting ceramic and indirect composite restorations. Material and method Human molars (n=20) donated by UNIFAL teeth bank were prepared and, after being divided into two groups, ceramic or composite cylinders were luted to them with two resin-based cements (conventional and self-adhesive). Prepared teeth were sectioned vertically in both buccal-lingual and mesio-distal directions, to obtain 8 mm high, square-shaped "sticks" that were subject to microtensile bond strength test, and the necessary force to fracture them was evaluated. Results were subject to two-way ANOVA and Tukey test. Result Minimum and maximum forces to disrupt conventional cement were greater than the required one for self-adhesive cement, as well as mean bond strength, despíte of the restorative material. Tukey test showed that diferences were statistically significant, regardless the restorative material. Conclusion Restorative materials did not influence microtensile bond strength values, with no statistically significant differences. The difference between microtensile bond strength values of resin cements tested was statistically significant.


Assuntos
Resistência à Tração , Adesivos , Análise de Variância , Cimentos de Resina , Porcelana Dentária , Resistência ao Cisalhamento , Restauração Dentária Permanente
5.
West China Journal of Stomatology ; (6): 619-622, 2018.
Artigo em Chinês | WPRIM | ID: wpr-772448

RESUMO

OBJECTIVE@#This work aimed to evaluate the influence of smear layer on the bonding effectiveness and durability of the self-adhesive resin cements to dentin.@*METHODS@#A total of 48 fresh caries-free third molars with exposed dentin surface were divided into two groups. The dentin surfaces were treated using a standard grit diamond bur (group A) or further polished using a fine grit diamond bur (group B) and then bonded with either of the two self-adhesive resin cements, namely, Clearfil SA Cement (CSA, Kuraray) and Multilink Speed (MS, Ivoclar Vivadent). After 24 h or 2-year water storage, a microtensile bond strength test was performed.@*RESULTS@#In group A, the dentin surface was rough, the smear layer was thick, and the dentin tubule orifice detritus showed low embolism value. In group B, the dentin surface roughness decreased, the embolism proportion increased, and the smear layer became thin. The initial bonding strengths of CSA and MS in group A were significantly lower than those in group B (P0.05).@*CONCLUSIONS@#The properties of the smear layer and the types of self-adhesive resin cement used affected the bond strength and durability.


Assuntos
Humanos , Resinas Compostas , Colagem Dentária , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Camada de Esfregaço , Propriedades de Superfície , Resistência à Tração
6.
Journal of Practical Stomatology ; (6): 455-459, 2015.
Artigo em Chinês | WPRIM | ID: wpr-463012

RESUMO

Objective:To introduce a new fixation set-up for micro-tensile test.Methods:Dentin-composite were bonded with AdperTM Single Bond 2 (SB2)and sectioned into stick-shaped specimens.Specimens from each tooth(n =6)were equally divided into Ciucchi's jig and the designed set-up(Control and experimental)groups for micro-tensile bond test according to the utilized fixa-tion set-up.The bonding interface failure mode was examined with field-emission scanning electron microscope (FESEM).Three-dimensional models of the two set-ups and the specimen were developed,stress distribution was analyzed by finite element analysis (FEA).Results:The bond strength(MPa)of experimental and control group was 32.76 ±7.43 and 43.58 ±4.72(P <0.05),the ratio of mixed failure was 28 /36 and 20 /36(P <0.05)respectively.FEA showed that the designed set-up for fixing the sticks pro-vided a uniform stress distribution along the long axis of the specimen.FEA and failure mode analysis confirmed such uniform distri-bution was also concentrated at the bonding interface.Conclusion:The new set-up is feasible for micro-tensile test.

7.
Braz. dent. j ; 25(6): 472-478, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-732254

RESUMO

To evaluate the microtensile bond strength (µTBS) of a fluoride-containing adhesive system submitted to a pH-cycling and storage time regimen for primary outcomes. As secondary outcomes the fluoride released amount was evaluated. Twelve dentin surfaces from sound third molar were divided into 2 groups according to adhesive systems: Clearfil SE Protect (PB) and Clearfil SE Bond (SE). Sticks obtained (1.0 mm2) from teeth were randomly divided into 3 subgroups according to storage regimen model: immediate (24h); 5-month deionized water (W); and pH-cycling model (C). All sticks were tested for µTBS in a universal testing machine. Fluoride concentration was obtained from 1-4 days and 30-day in W and 1-4 days in demineralization (DE)/remineralization (RE) solutions from C, using a fluoride-specific electrode. µTBS and fluoride released data were, respectively, submitted to ANOVA in a split plot design and Tukey, and Friedman' tests (a=0.05). There was no significant interaction between adhesive system and storage regimen for µTBS. W showed the lowest µTBS values. There was no significant difference between 24 h and C models for µTBS. There was no significant difference between adhesive systems. Failure mode was predominantly cohesive within composite for the 24 h and W, for the C group it was mixed for SE and cohesive within composite for PB adhesive system. Fluoride concentrations in the DE/RE solutions were less than 0.03125 ppm and not detected in W. In conclusion, the fluoride-containing adhesive system performed similarly to the regular one. Hydrolytic degradation is the main problem with both adhesive systems, regardless of fluoride contents.


O objetivo principal desse estudo foi avaliar a resistência de união à microtração de dois sistemas adesivos (com e sem flúor) após a ciclagem de pH e armazenagem em água deionizada. A quantidade de flúor liberada foi avaliada secundariamente. Doze terceiros molares hígidos foram separados em 2 grupos de acordo com o sistema adesivo: Clearfil SE Protect - com flúor (PB) e Clearfil SE Bond - sem flúor (SE). Os palitos (1 mm2) obtidos do mesmo dente foram aleatoriamente divididos em 3 subgrupos de acordo com o meio de armazenagem: em água deionizada por 24h ou 5 meses e ciclagem de pH. Os palitos foram tracionados em uma máquina de ensaio universal a 0,5 mm/min. A concentração de flúor foi analisada em água deionizada (1-4 dias e 30 dias) e na solução remineralizadora e desmineralizadora (1-4 dias) usando um eletrodo específico. Os dados de resistência de união e liberação de flúor foram, respectivamente, submetidos à Análise de Variância em esquema de parcela subdividida e ao teste de Friedman (a=0,05). Não houve nenhuma interação significativa na resistência de união entre os sistemas adesivos e os meios de armazenagem. Os menores valores de resistência de união à microtração foram encontrados para os palitos armazenados em água deionizada. Não houve nenhuma diferença significativa nos valores de resistência de união após 24h e ciclagem de pH. Nenhuma diferença significativa na resistência de união foi observada entre os 2 sistemas adesivos. O modo de falha foi predominantemente coesivo em compósito para os grupos armazenados em água por 24h ou 5 meses para ambos os sistemas adesivos. No grupo submetido à ciclagem, a falha foi mista para o SE e coesiva em compósito para o PB. A concentração de flúor nas soluções DE/RE foi menor que 0,03125 ppm e não detectada em água deionizada. Concluindo, o sistema adesivo com flúor (PB) apresentou performance similar ao sistema adesivo sem flúor (SE). A degradação hidrolítica foi o principal fator para ambos os sistemas adesivos, independente da adição de flúor.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antineoplásicos/administração & dosagem , Floxuridina/administração & dosagem , Antineoplásicos/toxicidade , Esquema de Medicação , Avaliação de Medicamentos , Tolerância a Medicamentos , Floxuridina/toxicidade , Isomerismo , Neoplasias/tratamento farmacológico
8.
Artigo em Espanhol | LILACS | ID: lil-684729

RESUMO

La técnica de adhesión en dentina es una técnica poco predecible y se agudiza aun más cuando la dentina ha sido afectada por caries ya que las alteraciones histológicas disminuyen la posibilidad de esta unión; no obstante la variación en la técnica de remoción del tejido cariado pudiera influir de manera independiente en la unión. El objetivo de esta investigación es determinar la influencia del método de remoción del tejido cariado en la resistencia adhesiva en micro tracción (µTBS) de resina compuesta unida a dentina humana afectada por caries. Se utilizaron 15 molares humanos afectados por caries y de manera aleatoria simple se dividieron en tres grupos (G1,G2,G3), luego se realizó un corte con disco de diamante (KG Sorensen® /Brasil) perpendicular al eje mayor del diente exponiendo la mayor cantidad de dentina afectada, el G1 fue sometido a remoción con Aire abrasivo de oxido de aluminio de 50 µm a una presión de 40 PSI (Microjato®, Bio-art /Brasil), al G2 se le eliminó la caries con fresa redonda de carburo N° 6 a baja velocidad (KG Sorensen® /Brasil)y al G3 se le eliminó con el método Químico/Mecánico (PAPACARIE ® /Brasil y Cucharita para dentina), la eliminación fue corroborada con fluorescencia laser (DIAGNOdent®, Kavo /Germany), posteriormente se aplicó la técnica de grabado total siguiendo las indicaciones del fabricante para adhesivo Excite ®( Ivoclar Vivadent Inc. /USA), y se restauraron 6 mm oclusales con resina compuesta Brilliant Enamel New Line® (Coltène-Whaledent /Germany.), luego se seccionaron con una sierra de precisión ISOMET 1000® (Buehler /USA) y se obtuvieron muestras de 1x1x10 mm , a continuación las muestras se prepararon para la prueba de micro tracción en la máquina de prueba universales AGS-J (Shimadzu /Japan) a una velocidad de desplazamiento de 0,5mm por min. Los datos fueron recolectados en hoja de cálculo Excel y analizados con un ANOVA de 1 Vía, en un nivel (µBts), el valor de p quedo preestablecido en p?0,05


The dentin adhesion technique is a quite unpredictable one and it is enhanced when the dentin has been affected because histological alterations reduce the chance for this union; however, the variation in the removal technique of caries-affected tissue could have an independent influence on the union. Aim: to determine the influence of the method of caries-affected tissue removal on the adhesive resistance in micro-tensile (µTBS) of composite bonded to human dentin affected by caries. Methods: 15 human molars affected by caries were randomly assigned into three groups (G1, G2, and G3). Then, one cut with a diamond disc (KG Sorensen® /Brasil) was performed perpendicular to the major axis of the teeth exposing the larger amount on affected dentin. G1 condition was removal with abrasive air of aluminum oxide of 50 µm at a 40 PSI (Microjato®, Bio-art /Brasil) pressure. G2 had caries removal with carbide round drill N° 6 at a low speed (KG Sorensen® /Brasil). Finally, for G3 caries was removed with the Chemical/Mechanical method (PAPACARIE ® /Brasil and spoon excavator). The elimination was corroborated by laser fluorescence (DIAGNODENT®, Kavo /Germany); later, the total etching technique was performed by following the manufacturer instructions for Excite ® (Ivoclar Vivadent Inc. /USA) and 6 oclusal mm were restored with composite Brilliant Enamel New Line® (Coltène-Whaledent /Germany.), then they were cut with a precision saw ISOMET 1000® (Buehler /USA) and 1x1x10 mm samples were obtained. The samples were prepared for the micro traction test in the universal testing machine AGS-J (Shimadzu /Japan) a speed of 0,5mm per minute. Data were recorded in Microsoft Excel and a one way ANOVA was performed for one level (µBts), the p value was established at p?0,05. Results: the mean µBts in MPa for each group and the standard deviation (±SD) was as follows: G1= 21,7 (8,6) G2=19,70 (10,5) G3=22,2 (9,7)


Assuntos
Humanos , Masculino , Feminino , Cárie Dentária , Dentina/patologia , Dente Molar , Cimentos de Resina , Odontologia
9.
Journal of Korean Academy of Conservative Dentistry ; : 423-429, 2004.
Artigo em Coreano | WPRIM | ID: wpr-109890

RESUMO

The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s, the second coat was re-applied and light-cured. In group III, after light-curing the second layer, the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system, 3 coats of Adper Prompt L-Pop had significantly thicker than SM, 2 coats of Adper Prompt L-Pop (p 0.05). And SM, 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).


Assuntos
Adesivos , Dentina , Diamante
10.
Journal of Korean Academy of Conservative Dentistry ; : 203-208, 2003.
Artigo em Coreano | WPRIM | ID: wpr-13465

RESUMO

The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of 1.5+/-0.1mm2. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min.. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.


Assuntos
Humanos , Adesivos , Cianoacrilatos , Esmalte Dentário , Instrumentos Odontológicos , Dentina , Diamante , Dente Molar , Saliva , Dente
11.
Journal of Practical Stomatology ; (6)2001.
Artigo em Chinês | WPRIM | ID: wpr-542455

RESUMO

0.05),respectively.The fractured adheisive dentin surface was mainly a mixed failue mode.Conclusions:There is no significant difference in the bond strengths of each of the three bonding agents to ND and CAD.

12.
Journal of Practical Stomatology ; (6)1996.
Artigo em Chinês | WPRIM | ID: wpr-546130

RESUMO

Objective:To evaluate the influence of delayed application of mixed self-etching bonding agent on the tensile bond strength.Methods:Two "two-bottle,one-step" self-etching adhesives,Adper Prompt and Xeno III,were evaluated.The occlusal enamel of human third molar was cut out and the exposed dentin surface was divided in two halves by a 1 mm deep groove in the labial-lingual orientation to allow for evaluation of immediate application and delayed application(0.5,1,2,3,4,5 and 6 h) of mixed self-etching bonding agent in the same specimen,followed by composite resin built-up on the adhesive.The bonded specimens were sectioned into beams of approximately 0.9 mm2 and subsequently subjected to micro-tensile bond strength testing at a crosshead speed of 1.0 mm/min.Results:The specimens bonded with the Adper Prompt within 5 h after mixing showed no different and that with the Xeno III within 3 h after mixing showed no different.Conclusion:The effective period for "two-bottle,one-step" self-etching adhesives after mixing is limited.Different bonding agents have different effective periods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA