Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Dental press j. orthod. (Impr.) ; 28(4): e232333, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1514053

RESUMO

ABSTRACT Introduction: Superposing 3D models is an imminent need. However, current methods rely on marking multiple points on the maxilla and mandible, which could increase point marking and overlapping errors. Objective: This study aimed at developing a method for superimposing 3D models of the maxillary and mandibular arches with Autodesk Inventor® engineering software, using a single universal coordinate system (UCS) point superposition. Methods: A total of 104 STL (stereolithography) models of the maxillary and mandibular arches exported from My iTero® platform were retrospectively selected, in which T0 and T1 were the initial and refinement periods, respectively (n=26 per group). The X, Y, and Z coordinates associated with a single point in each arch were inserted into the models with SlicerCMF® software for model orientation. The arch models with UCS registration were transferred to Autodesk Inventor® for superimposition and to measure tooth movements performed during Invisalign® treatment. Arch expansion, intrusion and rotation were analyzed by two examiners. The statistics were performed using intraclass correlation coefficients (ICC), Dahlberg's formula, and t-test (p<0.05). Results: A reliable method of superimposing 3D digital models using a single UCS point in the maxilla and mandible was developed. ICC showed excellent intra- and inter-examiner correlation (ICC>0.90). A systematic error was not found concerning linear and angular measurements (<1mm and <1.5°, respectively). Digital dental movements could be analyzed, including arch expansion, dental intrusion, and tooth rotation. Conclusions: The developed method was proven reliable and reproducible for superimposing 3D models of the maxillary and mandibular arches by using UCS system.


RESUMO Introdução: A sobreposição de modelos 3D é uma necessidade iminente. No entanto, os métodos atuais dependem da marcação de múltiplos pontos na maxila e na mandíbula, o que pode aumentar a incorporação de erros no processo de sobreposição. Objetivo: O objetivo desse estudo foi desenvolver um método para sobrepor modelos 3D das arcadas superior e inferior utilizando o software de engenharia Autodesk Inventor®, por meio da marcação de um único ponto em cada arcada, usando o sistema de coordenadas universal (UCS). Métodos: No total, 104 modelos STL das arcadas superior e inferior exportados da plataforma My iTero® foram selecionados retrospectivamente, onde T0 foi o período inicial e T1, o de refinamento (n=26 por grupo). As coordenadas X, Y e Z associadas a um único ponto em cada arcada foram inseridas nos modelos usando o software SlicerCMF®. Os modelos com os pontos UCS demarcados foram transferidos para o software Autodesk Inventor® para realizar a sobreposição e medir os movimentos dentários realizados durante o tratamento com Invisalign®. Os movimentos de expansão, intrusão e rotação foram analisados por dois examinadores. A análise estatística foi realizada usando os coeficientes de correlação intra-classe (ICC), fórmula de Dahlberg e teste t (p<0,05). Resultados: Foi desenvolvido um método confiável de sobreposição de modelos digitais 3D usando um único ponto UCS na maxila e mandíbula. O ICC apresentou excelente correlação intra e inter-avaliadores (ICC>0,90). Não foi encontrado erro sistemático nas medidas lineares e angulares (<1mm e <1,5°, respectivamente). Os movimentos dentários puderam ser analisados por meio do método proposto, incluindo expansão da arcada, intrusão e rotação dentária. Conclusão: O método desenvolvido provou ser confiável e reprodutível para sobreposição de modelos 3D das arcadas superior e inferior usando o sistema UCS com marcação de ponto único.

2.
Dental press j. orthod. (Impr.) ; 28(6): e2323110, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1528514

RESUMO

ABSTRACT Objective: The purpose of this prospective clinical trial was to explore the dental and soft tissue changes accompanying the use of skeletally anchored nickel-titanium (NiTi) extrusion arch in the correction of anterior open bite (AOB). Material and Methods: Twenty female patients with a mean age of 16.5 ± 1.5 years and a mean dentoalveolar AOB of 2.38±0.7 mm participated in this study. All patients were treated with an maxillary 0.017×0.025-in NiTi extrusion arch, with the aid of miniscrews inserted between the maxillary second premolars and first molars bilaterally, to act as indirect anchorage. Three-dimensional digital models and lateral cephalometric radiographs were taken just before the insertion of the extrusion arch (T0) and after 10 months (T1). Paired-sample t-tests were used in analyzing the data, to evaluate the changes after treatment (T1-T0). A significance level of p < 0.05 was used. Results: AOB was successfully closed in all patients, with a 4.35 ± 0.61 mm increase in the overbite. Maxillary incisors significantly extruded (2.52 ± 1.02 mm) and significantly reclined (5.78 ± 0.77°), with a resultant decrease in the overjet of 1.58 ± 0.5mm. A significant intrusion of maxillary first molars with no change in their inclination was observed. The upper lip showed a significant retraction tendency to the E-plane, and a significant increase in the nasolabial angle was observed. Conclusion: The skeletally anchored NiTi extrusion arch was an effective technique in treating AOB, with no adverse effects on the molars.


RESUMO Objetivo: O objetivo deste ensaio clínico prospectivo foi avaliar as alterações dentárias e em tecidos moles que acompanham o uso de arco de extrusão de níquel-titânio (NiTi) com ancoragem esquelético na correção da mordida aberta anterior (MAA). Material e Métodos: Participaram deste estudo 20 pacientes do sexo feminino com idade média de 16,5 ± 1,5 anos e MAA dentoalveolar (média de 2,38 ± 0,7 mm). Todos os pacientes foram tratados com arco de extrusão de NiTi 0,017×0,025" superior, com auxílio de mini-implantes inseridos entre os segundos pré-molares e primeiros molares superiores bilateralmente, para atuar como ancoragem indireta. Modelos digitais tridimensionais e radiografias cefalométricas laterais foram realizados imediatamente antes da inserção do arco de extrusão (T0) e após 10 meses (T1). Testes t para amostras pareadas foram utilizados na análise dos dados, para avaliar as alterações após o tratamento (T1-T0). Um nível de significância de p< 0,05 foi usado. Resultados: A MAA foi fechada com sucesso em todos os pacientes, com aumento de 4,35 ± 0,61 mm na sobremordida. Os incisivos superiores foram significativamente extruídos (2,52 ± 1,02 mm) e significativamente reclinados (5,78 ± 0,77°), com uma consequente diminuição na sobressaliência de 1,58 ± 0,5 mm. Foi observada intrusão significativa dos primeiros molares superiores, sem alteração na sua inclinação. O lábio superior apresentou tendência significativa de retração em relação ao plano E, e foi observado aumento significativo do ângulo nasolabial. Conclusão: O arco de extrusão de NiTi esquelético foi uma técnica eficaz no tratamento da MAA, sem efeitos adversos nos molares.

3.
Dental press j. orthod. (Impr.) ; 28(1): e2321331, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1430272

RESUMO

ABSTRACT Objective: To compare dental positional and gingival parameters of maxillary anterior teeth in unilateral cleft lip and palate (UCLP) after orthodontic treatment with canine substitution due to lateral incisor agenesis. Methods: This split-mouth study comprised 57 subjects with UCLP (31 male, 26 female) and agenesis of maxillary lateral incisor at the cleft side, from a single center. Canine substitution was completed after the secondary alveolar bone graft. Dental models were taken between 2 to 6 months after debonding (mean age: 20.4 years). The following variables were measured in the maxillary anterior teeth: crown height, width, proportion, and symmetry, as well as steps between incisal edges, gingival margins, tooth mesiodistal angulation and labiolingual inclination. Paired t-tests with Bonferroni post-hoc correction was used for comparisons between cleft and non-cleft sides (p<0.05). Results: At the cleft side, canines replacing missing lateral incisors had a higher crown height (0.77mm) and an increased width (0.67mm), and first premolars showed a shorter crown height (1.39mm). Asymmetries were observed in the gingival level of central and lateral incisors, with a greater clinical crown at the cleft side (0.61 and 0.81mm, respectively). Cleft side central incisors were more upright than their contralaterals (2.12º). Conclusions: Maxillary anterior teeth demonstrated positional, size and gingival height differences between cleft and non-cleft side after space closure of maxillary lateral incisor agenesis. Slight asymmetries in tooth position and gingival margin in the maxillary anterior teeth should be expected after orthodontic treatment in UCLP patients.


RESUMO Objetivo: O presente trabalho teve como objetivo comparar parâmetros dentários posicionais e gengivais de dentes anteriores superiores em pacientes com fissura labiopalatina transforame unilateral (FLPTU) após tratamento ortodôntico com substituição de incisivo lateral ausente por canino, devido a agenesia. Métodos: Esse estudo de boca dividida reuniu uma amostra, de um mesmo centro especializado de tratamento, de 57 indivíduos com FLPTU (31 homens, 26 mulheres) e agenesia do incisivo lateral superior no lado da fissura. A substituição do incisivo lateral por um canino foi concluída após o enxerto ósseo alveolar secundário. Os modelos dentários foram obtidos entre dois e seis meses após a remoção do aparelho (idade média: 20,4 anos). Foram mensuradas nos dentes anteriores as variáveis: altura, largura, proporção e simetria da coroa, bem como as distâncias entre as bordas incisais, margens gengivais, angulação mesiodistal e inclinação vestibulolingual. O teste t pareado com correção post-hoc de Bonferroni foi usado para comparações entre os lados fissurados e não fissurados (p<0,05). Resultados: No lado fissurado, os caninos que substituíram os incisivos laterais ausentes apresentaram uma altura de coroa maior (0,77 mm) e uma largura aumentada (0,67 mm). Os primeiros pré-molares apresentaram uma altura de coroa menor (1,39 mm). Assimetrias foram observadas no nível gengival dos incisivos centrais e laterais, com maior coroa clínica no lado fissurado (0,61 e 0,81mm, respectivamente). Os incisivos centrais do lado fissurado estavam mais intruídos do que os contralaterais (2,12 mm). Conclusão: Os dentes anteriores superiores demonstraram diferenças de posição, tamanho e altura gengival entre os lados fissurado e não fissurado, após o fechamento do espaço da agenesia dos incisivos laterais superiores. Leves assimetrias na posição do dente e margem gengival nos dentes anteriores superiores devem ser esperadas após o tratamento ortodôntico em pacientes com fissura labiopalatina transforame unilateral.

4.
J. health sci. (Londrina) ; 24(3): 167-172, 20220711.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1412657

RESUMO

The objective of this study was to evaluate the tooth crown inclination in maxillary and mandibular arches in Class III malocclusion individuals, to identify the presence and magnitude of compensation. The study was conducted on 46 plaster casts of individuals with Class III malocclusion, of both genders (25 males and 21 females), with mean age 21 years and 1 month, with indication for compensatory orthodontic treatment. The dental casts models were scanned and the tooth crown inclinations were measured and compared with standard values by the independent t test. All tests considered a significance level of 5% (p<0.05). According to the results there was extensive variation in tooth inclination in Class III malocclusions. Values distribution for incisors highlighted the significant concentration of maxillary incisors in the area of positive values, compared with a very expressive concentration of mandibular incisors in the area of negative values. Compared with normal standards, in Class III malocclusions, the maxillary posterior teeth exhibited smaller palatal inclination than normal, while the mandibular incisors and second molars presented greater lingual inclination. It was concluded that the analysis of inclinations of all crowns of both dental arches in Class III malocclusions, compared with normal standards, evidenced the presence of natural compensation for maxillary posterior teeth, with reduced palatal inclination, as well as increased lingual inclination in mandibular incisors. The parameters of compensation naturally present in Class III malocclusions described, especially in lower incisors, would help clinicians when compensatory treatment is considered. (AU)


O objetivo deste estudo foi avaliar a inclinação das coroas dentárias nas arcadas superior e inferior em indivíduos com má oclusão de Classe III, para identificar a presença e a magnitude da compensação. O estudo foi realizado em 46 modelos de gesso de indivíduos com má oclusão de Classe III, de ambos os sexos (25 homens e 21 mulheres), com média de idade de 21 anos e 1 mês, com indicação de tratamento ortodôntico compensatório. Os modelos de gesso foram digitalizados e as inclinações da coroa dos dentes foram medidas e comparadas com os valores de normalidade pelo teste t independente. Todos os testes estatísticos adotaram um nível de significância de 5% (p <0,05). De acordo com os resultados, houve grande variação na inclinação dentária nas más oclusões de Classe III. A distribuição dos valores para os incisivos destacou a concentração significativa de incisivos superiores na área de valores positivos, em comparação com uma concentração muito expressiva de incisivos inferiores na área de valores negativos. Comparados aos padrões de normalidade, nas más oclusões de Classe III, os dentes posteriores superiores exibiram inclinação palatina menor que o normal, enquanto os incisivos e segundos molares inferiores apresentaram inclinação lingual maior. Concluiu-se que a análise das inclinações de todas as coroas de ambas as arcadas dentárias nas más oclusões de Classe III, comparadas aos padrões de normalidade, evidenciou a presença de compensação natural para os dentes posteriores superiores, com diminuição da inclinação palatina, bem como aumento da inclinação lingual dos incisivos inferiores. Os parâmetros de compensação naturalmente presentes nas más oclusões de Classe III descritos, especialmente nos incisivos inferiores, podem auxiliar o clínico quando o tratamento compensatório é considerado. (AU)

5.
Dental press j. orthod. (Impr.) ; 24(2): 81-91, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001865

RESUMO

Abstract Historically, whether for research purposes or clinical monitoring, orthodontic evaluation of dental movements has been done using plaster study models and two dimensional (2D) radiographs. However, new frontiers for the diagnosis, planning and outcome assessment of orthodontic treatments have arisen, due to the revolutionary digital tools which enable a three dimensional (3D) computerized analysis of dental movements by means of digital models. However, the software for 3D analysis are often costly, resulting in limited access to orthodontists. The present study aims to describe, through a clinical case presented to the Brazilian Board of Orthodontics and Dentofacial Orthopedics, a method for the superimposition of maxillary digital models using an open-source software to evaluate dental movements.


Resumo Historicamente, a avaliação ortodôntica da movimentação dentária, seja com finalidade de pesquisa, seja para monitoramento clínico, tem sido feita por meio de modelos de estudo em gesso e radiografias em duas dimensões (2D). Entretanto, com o desenvolvimento da Ortodontia digital, novas fronteiras para o diagnóstico, planejamento e avaliação dos resultados dos tratamentos ortodônticos têm surgido. Os modelos digitais possibilitam uma análise computadorizada da movimentação dentária nas três dimensões (3D); porém, os softwares usados para as análises 3D geralmente são onerosos e de limitado acesso aos clínicos. O presente artigo visa descrever um método de sobreposição de modelos 3D da arcada dentária superior utilizando um software de livre acesso para avaliar a movimentação dentária, ilustrado por um caso clínico apresentado ao Board Brasileiro de Ortodontia e Ortopedia Facial.


Assuntos
Imageamento Tridimensional , Modelos Dentários , Software , Brasil , Maxila
6.
Dental press j. orthod. (Impr.) ; 22(5): 90-97, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891094

RESUMO

ABSTRACT Objective: To define a map of interradicular spaces where miniscrew can be likely placed at a level covered by attached gingiva, and to assess if a correlation between crowding and availability of space exists. Methods: Panoramic radiographs and digital models of 40 patients were selected according to the inclusion criteria. Interradicular spaces were measured on panoramic radiographs, while tooth size-arch length discrepancy was assessed on digital models. Statistical analysis was performed to evaluate if interradicular spaces are influenced by the presence of crowding. Results: In the mandible, the most convenient sites for miniscrew insertion were in the spaces comprised between second molars and first premolars; in the maxilla, between first molars and second premolars as well as between canines and lateral incisors and between the two central incisors. The interradicular spaces between the maxillary canines and lateral incisors, and between mandibular first and second premolars revealed to be influenced by the presence of dental crowding. Conclusions: The average interradicular sites map hereby proposed can be used as a general guide for miniscrew insertion at the very beginning of orthodontic treatment planning. Then, the clinician should consider the amount of crowding: if this is large, the actual interradicular space in some areas might be significantly different from what reported on average. Individualized radiographs for every patient are still recommended.


RESUMO Objetivo: elaborar um mapa dos espaços inter-radiculares nos quais os mini-implantes podem ser inseridos, em um nível coberto por gengiva inserida; e avaliar se existe correlação entre o apinhamento dentário e a disponibilidade de espaços. Métodos: radiografias panorâmicas e modelos digitais de 40 pacientes foram selecionados seguindo critérios de inclusão. Os espaços inter-radiculares foram medidos nas radiografias panorâmicas, enquanto a discrepância de modelo foi avaliada nos modelos digitais. Realizou-se, então, uma análise estatística para avaliar se os espaços inter-radiculares foram influenciados pela presença do apinhamento dentário. Resultados: na mandíbula, os locais mais adequados para a inserção dos mini-implantes foram os espaços compreendidos entre os segundos molares e primeiros pré-molares; na maxila, entre os primeiros molares e segundos pré-molares, bem como entre caninos e incisivos laterais, e entre os dois incisivos centrais. Os espaços inter-radiculares entre os caninos e incisivos laterais superiores e entre o primeiro e o segundo pré-molares inferiores mostraram-se influenciados pela presença do apinhamento dentário. Conclusões: o mapa dos espaços inter-radiculares mais adequados aqui proposto pode ser adotado como um guia geral para a inserção de mini-implantes, e pode ser usado logo ao início do planejamento do tratamento ortodôntico. Em seguida, o clínico deve levar em consideração a quantidade de apinhamento: caso esse seja grande, o real espaço inter-radicular, em algumas áreas, poderá ser significativamente diferente da média aqui relatada. Assim, recomenda-se que sempre sejam feitas radiografias individualizadas para cada paciente.


Assuntos
Humanos , Parafusos Ósseos , Implantação Dentária Endóssea/métodos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Má Oclusão , Simulação por Computador , Processamento de Imagem Assistida por Computador , Radiografia Panorâmica , Modelos Dentários
7.
Ortodontia ; 49(6): 558-658, nov.-dez 2016. ilus, tab
Artigo em Português | LILACS, BBO | ID: biblio-875260

RESUMO

Introdução: com a crescente utilização dos modelos digitais em Ortodontia, aumenta também a necessidade de se conhecer as opções disponíveis para sua obtenção. Atualmente, a alternativa mais utilizada é o escaneamento de modelos de gesso, que pode ser realizado em scanners a laser, por luz estruturada ou por tomografia computadorizada. O objetivo deste trabalho foi avaliar, através de uma análise por sobreposição de modelos digitais, a acurácia dos modelos digitais gerados por estes três métodos de escaneamento e a influência de dois diferentes níveis de resolução de escaneamento. Material e métodos: 30 pares de modelos de gesso foram escaneados utilizando as três tecnologias. O escaneamento por luz estruturada foi realizado com duas configurações do nível de resolução: máxima e padrão. Os modelos digitais gerados foram sobrepostos e as diferenças entre as superfícies foram calculadas. Mapas de cores foram utilizados para evidenciar as discrepâncias entre os modelos. Resultados: para todos os parâmetros avaliados, foram obtidas diferenças estatisticamente significantes. As diferenças entre os modelos escaneados a laser e por luz estruturada foram menores, o que sugere maior similaridade entre eles. Conclusão: as diferenças encontradas entre os modelos digitais obtidos pelas três tecnologias de escaneamento estudadas foram estatisticamente significantes. No entanto, por serem muito pequenas quantitativamente, não foram consideradas clinicamente significantes. Não houve diferença entre os dois níveis de resolução estudados, portanto, os três métodos de escaneamento avaliados possuem uma acurácia clinicamente aceitável para ser utilizado em Ortodontia.


Introduction: the increasing use of digital models in orthodontics demands knowledge of the available options for their acquisition. Currently, the most used option is the plaster model scanning, which can be made by laser, structured light and computed tomography scanners. The aim of this study was to evaluate, by a model superimposition analysis, the accuracy of digital models acquired by these three scanning methods and the influence of two different resolution levels of scanning. Methods: thirty pairs of plaster models were scanned using three different scanning technologies: laser, structured light and computed tomography. The structured light scanning was performed using two different resolution levels: maximum and standard. The respective digital models were superimposed and their mean differences were compared using color maps by Geomagic Qualify software. Results: for all parameters studied, statistically significant differences were found. Lower differences were presented between models scanned by laser and structured light techniques, which suggests a higher similarity between them. Conclusion: the differences found between digital models obtained by the three scanning technologies were statistically significant. However, they were quantitatively very small, which was considered clinically insignificant. There was no difference between the two resolution levels of scanning studied. Therefore the three scanning methods studied presented accuracy clinically acceptable to be used in orthodontics.


Assuntos
Modelos Dentários , Precisão da Medição Dimensional , Modelos Dentários/tendências , Odontometria/métodos
8.
Ortodontia ; 48(1): 43-58, jan.-fev. 2015. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-761883

RESUMO

Introdução: o objetivo deste estudo foi avaliar a acurácia e a confiabilidade de medições feitas em modelos digitais obtidos com um scanner a laser de superfície (R700; 3Shape, Copenhagen, Dinamarca). Material e métodos: foram selecionados 30 modelos ortodônticos de gesso de dentições permanentes. As medições foram realizadas por três examinadores com um paquímetro digital, diretamente sobre os modelos de gesso, e digitalmente, através do programa Ortho Analyser (3Shape, Copenhagen, Dinamarca), nos modelos digitais. Foram determinadas 62 medidas, incluindo diâmetro e altura dentária, overjet, overbite, distâncias intercanino e intermolar, e relação sagital bilateral. Utilizou-se o teste t pareado para avaliar o erro intraexaminador e a acurácia das medições nos modelos digitais. Avaliou-se a reprodutibilidade entre os examinadores por meio do coeficiente de correlação intraclasse e a confiabilidade pelo teste de Bland e Altman. Resultados: apesar de existirem diferenças estatisticamente significantes entre as medições realizadas entre os modelos de gesso e os digitais, as discrepâncias foram consideradas clinicamente não significantes. Tanto os modelos de gesso quanto os modelos digitais apresentaram altos valores no coeficiente de correlação intraclasse entre os examinadores. Conclusão: os modelos digitais por escaneamento do modelo de gesso, utilizando o scanner R700 e o programa Ortho Analyser, podem ser utilizados com acurácia clinicamente aceitável e uma excelente confiabilidade e reprodutibilidade. Os modelos digitais podem substituir os modelos de gesso com segurança.


Introduction: the aim of this study was to evaluate the accuracy and reliability of measurements made on digital models obtained with a laser scanner surface (R700; 3Shape, Copenhagen, Denmark). Material and methods: thirty orthodontic plaster models of permanent dentition were selected. The measurements were performed by three examiners with a digital caliper directly on the plaster casts and digitally, through Ortho Analyser software (3Shape, Copenhagen, Denmark), in digital models. It was determined sixty two measures, including diameter and tooth height, overjet, overbite, intercanino and intermolar distances and bilateral sagittal relationship. It was used paired t test to assess intra-examiner error and the accuracy of measurements in digital models. It was evaluated the reproducibility between examiners using the intraclass correlation coefficient and reliability by Bland and Altman test. Results: although there were significant differences between the plaster casts and the digital models measurements, the discrepancies were considered clinically insignificant. Plaster casts and digital models showed high values of intraclass correlation coefficient among examiners. Conclusion: digital models by scanning plaster cast using the R700 scanner and Ortho Analyser software can be used with clinically acceptable accuracy and excellent reliability and reproducibility. Digital models can replace the plaster models safely.


Assuntos
Arco Dental , Modelos Dentários , Diagnóstico por Imagem , Precisão da Medição Dimensional , Odontometria
9.
Rev. Clín. Ortod. Dent. Press ; 13(5): 31-38, out.-nov. 2014. tab, ilus
Artigo em Português | LILACS, BBO | ID: biblio-856012

RESUMO

Introdução: as seis chaves de oclusão normal, descritas por Lawrence Andrews em meados da década de 60, descrevem os parâmetros de inclinação e angulação normais individuais de cada dente. Objetivo: diante dos avanços tecnológicos, esse artigo tem como objetivo descrever um novo método de mensuração tridimensional da inclinação e angulação de dentes, usando modelos digitais. Métodos: após escaneamento dos modelos....., os arquivos foram importados para o software VistaDent 3D (Dentsply - Nova York, EUA), onde uma análise denominada C-TA foi criada utilizando um módulo de cefalometria tridimensional para avaliar a inclinação e angulação de cada um dos elementos dentários... Para análise da reprodutibilidade de método, foram realizadas duas mensurações de 100 elementos dentários, por um mesmo examinador calibrado. Resultados: o novo método introduzido mostrou-se excelente replicabilidade, sem diferenças estatisticamente significativas entre as duas medições realizadas, com erro casual relativamente pequeno e alto índice de correlação, estatisticamente significativa. Conclusões: a metodologia inovadora mostrou-se apta a reproduzir, de maneira fiel, o mais importante estudo da Ortodontia referente à inclinação e angulação dentária. A excelente replicabilidade e simplicidade do método permite que seja empregado em pesquisas com modelos tridimensionais, descortinando os limites da movimentação e compensação dentária, bem como explicitando os valores da oclusão normal não tratada, em diferentes grupos étnicos e padrões faciais.


Assuntos
Imageamento Tridimensional/métodos , Modelos Anatômicos , Anormalidades Dentárias , Guias como Assunto , Torque
10.
Ortodontia ; 47(1): 75-82, jan.-fev. 2014. ilus
Artigo em Português | LILACS, BBO | ID: lil-715156

RESUMO

O modelo digital pode se tornar em breve uma realidade na clínica ortodôntica, pois apresenta grandes vantagens e facilita o planejamento dos casos clínicos, com a possibilidade de inter-relação com outros arquivos digitais. Os trabalhos publicados na literatura demonstraram que os modelos digitais apresentam precisão e confiabilidade aceitáveis para serem aplicados como método de diagnóstico, além de auxiliar no planejamento ortodôntico. No entanto, este recurso ainda é pouco explorado no Brasil. Este trabalho objetiva apresentar o panorama atual da utilização dos modelos digitais em Ortodontia.


The digital model may soon become a reality in clinical orthodontics because it presents great advantages and facilitates treatment planning, with the possibility of interrelation with other digital files. The published papers have shown that digital models exhibit acceptable accuracy and reliability to be applied as a method to assist the diagnosis and orthodontic planning. However, this resource is still little explored in Brazil. This paper aims to present a current overview of the use of digital models in orthodontics.


Assuntos
Diagnóstico por Imagem , Imageamento Tridimensional , Teste de Materiais , Modelos Dentários/tendências , Modelos Dentários , Tecnologia Odontológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA