Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
West China Journal of Stomatology ; (6): 568-572, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1007940

RESUMO

OBJECTIVES@#This study aimed to remove occlusal veneers of varied thicknesses and compositions by Er:Yag laser in vitro and analyze the interfacial microstructure between veneers and tooth that irradiated by laser, by which experimental evidence could be provided to support the non-invasive removal of occlusal veneerby laser.@*METHODS@#Fresh mandibular premolars extracted for orthodontic requirements were collected for tooth preparation. Three kinds of ceramic materials (Vita Suprinity, Vita Mark Ⅱ, and Upcera Hyramic) were selected to fabricate occlusal veneer with different thicknesses (1.0, 1.5, and 2.0 mm). One week later, Er:Yag laser (2.5 W and 3.5 W) was used to irradiate and remove the occlusal veneer and recorded the timespan. After the removal operation, the micro-morphologies of samples were examined by scanning electron microscope.@*RESULTS@#Upcera Hyramic veneer failed to be removed (>20 min); the operation span at 2.5 W, Vita Suprinity (96.0 s±16.0 s) was longer than Vita MarkⅡ(84.5 s±19.5 s) in the 1.0 mm group (P<0.05), and Vita Suprinity (246.5 s±13.5 s) was longer than Vita MarkⅡ(170.0 s±14.0 s) in the 1.5 mm group (P<0.05). At 3.5 W, Vita Suprinity (381.0 s±24.0 s) was longer than Vita MarkⅡ(341.5 s±26.5 s) in the 2.0 mm group.@*CONCLUSIONS@#Increasing laser power could shorten the operation span and facilitate the removal of occlusal veneers with the same thickness and composition. The occlusal veneer was sustained when insufficient laser power was applied. With the same laser power and ceramic thickness, laser penetration could interfere with the integral of the ceramic structure when the laser interacted with the bonding layer. With the same ceramic composition and laser power, the operation span and laser power increased with the thickness of the occlusal veneer. However, the laser was incapable of removing occlusal resin veneer directly.


Assuntos
Lasers de Estado Sólido , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Dente Pré-Molar , Facetas Dentárias
2.
Odovtos (En línea) ; 24(3)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1406149

RESUMO

Abstract To evaluate stress distribution when applying vertical and tangential forces to 1mm thick occlusal veneers with different finish lines preparations, using the finite element method. One extracted third molar was prepared for occlusal veneers, firstly without any bevel. It was scanned in order to design two groups of lithium disilicate (G1A, G2A) and composite resin (G1B, G2B) occlusal veneers. Then, the third molar preparation was modified, beveling the finish line and it was subsequently scanned again to design the occlusal veneer groups with bevel (LD: G3A, G4A and CR: G3B, G4B). The four groups were subjected to different forces (400 N vertical and 900 N tangential). At 400 N, the non-beveled veneers showed slightly higher Von Mises stress values (G1A: 783 MPa and G1B 736.5 MPa) than the beveled veneers (G3A: 685.7 MPa and G3B: 675.8 MPa). However, when 900 N tangential forces were applied, the beveled occlusal veneers showed higher Von Mises stress values (G4A: 4297 MPa and G4B: 4133 MPa) than the non-beveled occlusal veneers (G2A: 2581.1 MPa and G2B: 3519.1 MPa). Furthermore, it was observed that the tissue under the occlusal veneers with bevel showed higher Von Mises stress values than the models without any bevel. Beveled and non-beveled occlusal veneers of lithium disilicate and composite resin presented similar stress distribution values when vertical forces of 400 N were applied; whereas with tangential forces of 900 N applied near to the finish line, the beveled groups presented notably higher stress values than the non-beveled groups. However, both finish line preparations presented adequate values for possible clinical performance.


Resumen Evaluar la distribución de estrés al aplicar fuerzas verticales y tangenciales en carillas oclusales de 1mm de espesor con diferentes líneas de terminación marginal por el método de elementos finitos. Se preparó un tercer molar extraído para carilla oclusal, primero sin bisel. Se escaneó para diseñar dos grupos de carillas oclusales de disilicato de litio (G1A, G2A) y resina compuesta (G1B, G2B). Después, esta preparación molar fue modificada, biselando la línea de terminación y escaneándola nuevamente para diseñar los grupos de carillas oclusales con bisel (DL: G3A, G4A and RC: G3B, G4B). Los 4 grupos fueron sometidos a fuerzas diferentes (400 N vertical y 900 N tangencial). Con 400 N, las carillas sin bisel presentaron ligera mayor tensión de Von Mises (G1A: 783 MPa y G1B 736.5 MPa) que las carillas con bisel (G3A: 685.7 MPa y G3B: 675.8 MPa). De distinta forma, al aplicar fuerzas tangenciales de 900 N, las carillas oclusales con bisel presentaron mayor tensión de Von Mises (G4A: 4297 MPa y G4B: 4133 MPa) que las carillas oclusales sin bisel (G2A: 2581.1 MPa y G2B: 3519.1 MPa). Además, se observó que los tejidos subyacentes a las carillas oclusales con bisel, presentaron mayor tensión de Von Mises, frente a los modelos sin bisel. Las carillas oclusales con y sin bisel de disilicato de litio y resina compuesta presentaron una distribución de estrés similar con fuerzas verticales de 400 N, por otro lado, con fuerzas tangenciales de 900 N, los grupos con bisel presentaron notablemente mayor tensión que los grupos sin bisel. Sin embargo, ambos diseños de terminación marginal presentaron valores adecuados para un posible desempeño clínico.


Assuntos
Humanos , Força de Mordida , Resinas Compostas , Facetas Dentárias
3.
Braz. dent. j ; 33(4): 71-78, July-Aug. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1394085

RESUMO

Abstract This study was aimed to evaluate the fit of occlusal veneer restoration for two CAD/CAM materials with different cement space settings, using microCT scans. Sixty resin dies were made and divided into two groups (n=30) according to the materials, (I): Hybrid all-ceramic, and (II): zirconia-reinforced lithium silicate glass-ceramic. Each group was subdivided into three subgroups (n=10) according to the cement space parameters (30, 40, and 50 µm). Occlusal veneers for the six subgroups were milled. A circle with 20 different sections was placed at the center of every scanned specimen to measure four different locations (Occlusal, Axial, Marginal, and Absolute marginal discrepancy). Data were analyzed using two-way ANOVA at a 0.05 level of significance. There was no statistically significant effect of material type on the mean values of internal and marginal gaps for the three cement space parameters (P>0.05). There were no statistically significant differences in the occlusal and axial gap between the cement space parameters, furthermore, there were statistically significant differences in marginal gap distances and absolute marginal discrepancies (P>0.05). Hybrid all-ceramic showed smaller marginal and internal discrepancies than zirconia-reinforced lithium silicate glass-ceramic without statistically significant differences, and, for both materials, 50 µm cement space significantly improved the marginal fit and absolute marginal discrepancy.


Resumo Este estudo teve como objetivo avaliar o ajuste da restauração de facetas oclusais para dois materiais CAD/CAM com diferentes configurações de espaço de cimento, usando microCT. Foram feitos sessenta moldes de resina e divididos em dois grupos (n=30) de acordo com os materiais, (I): cerâmica pura híbrida, e (II): cerâmica de vidro de silicato de lítio reforçada com zircónia. Cada grupo foi subdividido em três subgrupos (n=10), de acordo com os parâmetros do espaço de cimento (30, 40, e 50 µm). As facetas oclusais para os seis subgrupos foram fresadas. Um círculo com 20 secções diferentes foi colocado no centro de cada amostra digitalizada para medir quatro locais diferentes (Oclusal, Axial, Marginal, e discrepância marginal absoluta). Os dados foram analisados utilizando ANOVA bidireccional a um nível de significância de 0,05. Não houve efeito estatisticamente significativo do tipo de material nos valores médios das aberturas internas e marginais para os três parâmetros do espaço de cimento (P>0,05). Não houve diferenças estatisticamente significativas no intervalo oclusal e axial entre os parâmetros do espaço de cimento, além disso, houve diferenças estatisticamente significativas nas distâncias do intervalo marginal e discrepâncias marginais absolutas (P>0,05). A cerâmica pura híbrida mostrou discrepâncias marginais e internas menores do que a cerâmica de vidro de silicato de lítio reforçada com zircónia sem diferenças estatisticamente significativas, e, para ambos os materiais, 50 µm de espaço de cimento melhoraram significativamente o ajuste marginal e a discrepância marginal absoluta.

4.
Journal of Peking University(Health Sciences) ; (6): 977-982, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942284

RESUMO

OBJECTIVE@#To evaluate the morphology accuracy of direct occlusal veneer using two types of modified stamp-technique, comparing the Results of two types of stamp and different composite resin.@*METHODS@#Model scanner was used to get the original data from the standard resin teeth in plastic model. Two types of stamps were made: solid silicon stamp and transparent silicon stamp. In the study, 54 resin tooth were randomly divided into 9 groups: Groups 1-8 were restored by direct composite resin, using general and bulk-filled composite resin in occlusal veneer (1 mm or 2 mm) with two types of stamp-technique (the solid silicon, and the transparent silicon), and the control group was restored by indirect way using CAD/CAM composite resin restoration by biocopy technique to mimic the original shape of the teeth. After the resin teeth were prepared for occlusal veneer, the direct and indirect composite resins were restored. After the restoration was finished, the data were obtained again by the same model scanner in the plastic model. 3D comparisons were made using the original and restoration data, the average difference and the root mean square of difference (RMS) were recoded from the software. The RMS of all the groups were analyzed using one way ANOVA (α=0.05).@*RESULTS@#The RMS of occlusal surface in solid silicon stamp group was (0.136±0.031) mm, in transparent silicon group was (0.130±0.024) mm, and in control group was (0.130±0.009) mm. There were no significant difference. While the RMS of buccal/lingual surface in solid silicon stamp group was the smallest [(0.135±0.020) mm, P < 0.05], and in transparent silicon group it was (0.147±0.021) mm, and control group (0.153±0.014) mm. The general composite resin using the two types of stamp had the largest occlusal RMS in 2 mm occlusal veneer, which were significantly larger than control group (P < 0.05).@*CONCLUSION@#The direct occlusal veneer using two types of modified "stamp-technique" had relatively good morphology accuracy. Direct occlusal veneer using bulk-filled composite resin made with two types of stamp technique had even more accurate morphology than using general composite resin. The solid silicon stamp had a better morphology accuracy in buccal/lingual surface than the transparent silicon stamp.


Assuntos
Humanos , Resinas Compostas , Desenho Assistido por Computador , Restauração Dentária Permanente , Teste de Materiais , Dente , Fraturas dos Dentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA