Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-1008913

RESUMO

In this paper, the differences between air probe and filled probe for measuring high-frequency dielectric properties of biological tissues are investigated based on the equivalent circuit model to provide a reference for the methodology of high-frequency measurement of biological tissue dielectric properties. Two types of probes were used to measure different concentrations of NaCl solution in the frequency band of 100 MHz-2 GHz. The results showed that the accuracy and reliability of the calculated results of the air probe were lower than that of the filled probe, especially the dielectric coefficient of the measured material, and the higher the concentration of NaCl solution, the higher the error. By laminating the probe terminal, liquid intrusion could be prevented, to a certain extent, to improve the accuracy of measurement. However, as the frequency decreased, the influence of the film on the measurement increased and the measurement accuracy decreased. The results of the study show that the air probe, despite its simple dimensional design and easy calibration, differs from the conventional equivalent circuit model in actual measurements, and the model needs to be re-corrected for actual use. The filled probe matches the equivalent circuit model better, and therefore has better measurement accuracy and reliability.


Assuntos
Reprodutibilidade dos Testes , Cloreto de Sódio , Calibragem
2.
Artigo em Chinês | WPRIM | ID: wpr-828923

RESUMO

OBJECTIVE@#To investigate the sensing volume of open-ended coaxial probe technique for measurement of dielectric characteristics.@*METHODS@#A measurement model combining macro- measurement device with a layer model of dielectric properties parameters was established for evaluating the sensing volume of open-ended coaxial probe technique. We defined sensing depth and sensing diameter to describe the distance that could be detected in vertical and horizontal direction. Using a variety of materials with different dielectric properties (Teflon, deionized water, ethanol, and gradient concentration sodium chloride solution), a layered model of dielectric properties differentiation was established. The total combined uncertainties (TCU) were calculated for different output power, and the output power was controlled to increase from -50 dBm to 15 dBm to calibrate the error range of the dielectric properties measurement system. The optimal output power range was determined based on the results of TCU test. In sensing volume measurement experiment, we set the control groups based on measurement parameters that potentially affect the sensing volume including output power (-10, -5, 0, 3, 6, and 9 dBm), frequency (1-500 MHz), Teflon, deionized water, and ethanol to form a dielectric constant difference between high and low contrast groups. Different concentrations of sodium chloride solution and Teflon were used to generate a conductivity difference between high and low contrast groups. These groups were tested in the sensing depth and sensing diameter measurement experiments.@*RESULTS@#The result of TCU test indicated that accurate and stable measurement results could be obtained when the output power was greater or equal to-10 dBm (TCU < 2%). Sensing volume measurement experiment revealed a positive correlation between the sensing depth and output power ( < 0.05). As the measured power increased, the sensing depth gradually increased in deionized water and ethanol, and the difference reached 70 μm. The sensing depth was negatively correlated frequency ( < 0.05). As the concentration of sodium chloride solution increased, the corresponding sensing depth gradually decreased, with a difference reaching 270 μm. The sensing depth of high dielectric materials was greater than that pf low dielectric materials. The results of sensing diameter measurement were not obviously affected by the measurement parameters, and the sensing diameter was stable in a fixed range (1.0 to 1.8 mm) between the diameter of the inner conductor and the diameter of the insulation layer, and was less than the diameter of the probe.@*CONCLUSIONS@#The sensing volume of open-ended coaxial probe technique is affected by measurement parameters and dielectric properties of materials, which significantly affect the sensing depth.


Assuntos
Algoritmos , Condutividade Elétrica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA