Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. cuba. invest. bioméd ; 39(3): e634, jul.-set. 2020. tab, graf
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1138935

RESUMO

Introducción: El carcinoma papilar de tiroides es la causa más frecuente de cáncer de naturaleza endocrina. Constituye la variante histológica de mejor pronóstico, sin embargo, en ocasiones es motivo de importantes dudas diagnósticas con otras variantes de evolución tórpida, lo que dificulta que un mayor número de pacientes se beneficie con un tratamiento individualizado y conservador. Por esta razón, se desarrollan estudios en los que cada vez más se añaden procedimientos morfométricos y densitométricos, los que permiten disminuir la subjetividad en el diagnóstico histopatológico. Objetivo: Determinar la densidad óptica nuclear en el carcinoma papilar de tiroides. Método: Se realizó un estudio morfométrico de serie de casos con 12 pacientes con carcinoma papilar de tiroides, atendidos en el Hospital Provincial Universitario Vladimir Ilich Lenin. Se seleccionaron 36 campos y se midieron 965 núcleos celulares, lo que constituyó la muestra del estudio. Se determinó la densidad óptica nuclear como indicador morfométrico del carcinoma papilar de tiroides. Resultados: El valor de la densidad óptica nuclear fue 1,14, considerado bajo. Conclusiones: Se determinó la densidad óptica nuclear del carcinoma papilar de tiroides en los casos estudiados, lo que puede contribuir a su diagnóstico histopatológico(AU)


Background: Papillary thyroid carcinoma is the most frequent cause of endocrine cancer. It is an histological variant with the best prognosis, however, sometimes it is a reason for significant diagnostic doubts with other variants of torpid evolution, which makes it difficult for a greater number of patients to benefit from an individualized and conservative treatment. For this reason, studies are developed in which more and more morphometric and densitometric procedures are added, which allow reducing the subjectivity in the histopathological diagnosis and could represent a tool of great value. Objective: To determine the nuclear optical density in papillary thyroid carcinoma. Method: A morphometric study of a series of cases was carried out with 12 patients with this histopathological diagnosis, attended at the Vladimir Ilich Lenin University Provincial Hospital. We chose 36 fields and 965 cell nuclei were measured, which constituted the study sample. Nuclear optical density was determined as a morphometric indicator of papillary thyroid carcinoma. Results: The value of nuclear optical density was 1, 14. It is considered low. Conclusion: Nuclear optical density of papillary thyroid carcinoma was determined in the studied cases that may contribute to histopathological diagnosis(AU)


Assuntos
Humanos , Masculino , Feminino , Neoplasias da Glândula Tireoide/ultraestrutura , Câncer Papilífero da Tireoide/diagnóstico , Prognóstico , Contagem de Células/métodos , Câncer Papilífero da Tireoide/secundário
2.
Braz. j. vet. res. anim. sci ; 45(5): 339-347, 2008. tab, ilus
Artigo em Inglês | LILACS | ID: lil-504627

RESUMO

Acupuncture promotes peripherical sensory stimulation and local and distant release of neuropeptides and can influence bone healing. The aim of this controlled and prospective clinical study was to evaluate the effects of electroacupuncture (EA) in bone healing and bone mineral content of canine radius-ulna fracture after closed reduction and external immobilization. Ten dogs with radius-ulna fractures were randomly allocated to 1 of 2 treatment groups. Group 1 dogs (n=5) received percutaneous EA immediately after closed reduction and external immobilization; after this first treatment, the frequency of application was twice a week during 4 weeks. Group 2 dogs (n=5) did not receive EA treatment. Radiographic score (RS) system and Radiographic optical densitometry (ROD) were used to assessment of fracture healing at the first day of clinical evaluation (M1), 30 days (M30) and 45 days after treatment (M45). Values of P<0.05 were considered significant. Mean±SD ROD values (mmAl) between groups 1 and 2 did not differ significantly (P=0.15) at all periods, respectively M1 values (4.94±0.94; 4.3±1.14), M30 (5.19±1,24; 4,91±1.45) and M45 (5.16±1.12; 5.31±1.71). Mean±SD RS values of group 1 at M30 (2.8±0.83) was significantly different (P=0.003) from M45 (4.6±0.54). However, mean±SD RS values of group 2 at M30 (4.4±1.51) was not significantly different (P=0.30) from M45 (5.16±0.75). Comparisons of mean±SD RS values between groups 1 and 2 showed no significant difference at M30 (P=0.07) and M45 (P=0.19). Results demonstrated that EA treatment did not accelerate bone healing and did not enhance bone mineral density in canine radius-ulna fracture during the 45 days of follow-up.


Acupuntura promove estimulação sensorial periférica e liberação de neuropeptídeos, podendo influenciar a consolidação óssea. O objetivo deste estudo clínico prospectivo foi avaliar os efeitos da eletroacupuntura (EA) na consolidação óssea e densidade mineral óssea em cães com fratura de rádio-ulna (FRU) após redução fechada e imobilização externa. Dez cães com FRU foram aleatoriamente destinados em dois grupos. Grupo 1 (n=5) recebeu EA percutânea imediatamente após a redução fechada e imobilização externa; após este primeiro momento, foram feitas aplicações duas vezes por semana durante 4 semanas. Grupo 2 (n=5) não recebeu EA. Um sistema de escore radiográfico (ER) e densitometria óptica radiográfica (DOR) foram utilizados para avaliar a consolidação da fratura no primeiro dia de avaliação clínica no hospital (M1), 30 dias (M30) e 45 dias (M45) após tratamento. O nível de significância adotado foi de 5%. Valores (média ±DP) de DOR (mmAl) entre os grupos 1 e 2 não tiveram diferença significativa (P=0.15) em todos os momentos, respectivamente valores de M1 (4.94±0.94; 4.3±1.14), M30 (5.19±1,24; 4,91±1.45) e M45 (5.16±1.12; 5.31±1.71). Média±DP de ER do grupo 1 no M30 (2.8±0.83) foi significativamente diferente (P=0.003) do M45 (4.6±0.54). Entretanto, média±DP de ER do grupo 2 no M30 (4.4±1.51) não teve diferença significativa (P=0.30) do M45 (5.16±0.75). Comparações dos valores de ER entre os grupos 1 e 2 não tiveram diferença significativa no M30 (P=0.07) e M45 (P=0.19). Conclui-se que a EA não acelerou a consolidação óssea e não aumentou a densidade mineral óssea em cães com FRU durante os 45 dias avaliados após o tratamento.


Assuntos
Animais , Regeneração Óssea , Cães , Densitometria/métodos , Eletroacupuntura/efeitos adversos , Eletroacupuntura/métodos , Fraturas Ósseas/prevenção & controle , Radiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA