Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Assunto principal
Intervalo de ano
1.
International Eye Science ; (12): 1012-1016, 2023.
Artigo em Chinês | WPRIM | ID: wpr-973796

RESUMO

AIM: To investigate the difference, correlation, and consistency of corneal thickness and the thinnest point position detected by Pentacam HR corneal topography map and RTVue optical coherence tomography(OCT)in patients with keratoconus.METHODS: Cross-sectional comparative study. The corneal curvature map, corneal thickness map, thinnest point position, and thinnest point thickness were detected by Pentacam HR and RTVue OCT. Paired sample t-test was used for data consistent with normal distribution, and paired sample rank sum test was used for data inconsistent with normal distribution. Spearman correlation analysis and Bland-Altman analysis were used for the correlation and consistency of the two measurement methods.RESULTS: A total of 63 patients(105 eyes)with keratoconus were included in this study, including 49 males(77.8%)and 14 females(22.2%), aged 22.24±6.19 years; among them, relevant data of Pentacam HR topographic map: Km was 47.85±4.73D and Kmax was 55.43±8.72D. In measuring central corneal thickness and the thinnest point thickness of keratoconus, the Pentacam HR was 4.70μm and 19.46μm thicker than the mean value measured by RTVue OCT(P<0.05). There was no significant difference between the horizontal and vertical coordinates of the thinnest points measured by the two devices(P>0.05). The central corneal thickness and the thinnest point thickness measured by the two devices were highly correlated, the horizontal coordinate of the thinnest point was moderately correlated, and the vertical coordinate of the thinnest point was weakly correlated. Bland-Altman analysis showed that the central corneal thickness, the thinnest point thickness, the horizontal coordinate of the thinnest point, and the vertical coordinate of the thinnest point were 95.2%(100/105)and 93.3%(98/105), 95.2%(100/105), 95.2%(100/105)respectively, which were within the 95% consistency limit, while the consistency ranges were -36.00~+26.62μm, -42.27~+3.36μm, -0.80~+0.84mm, and -1.95~+1.06mm, respectively.CONCLUSION: In keratoconus, the central corneal thickness and the thinnest point thickness measured by Pentacam HR were higher than those measured by RTVue OCT. It is not recommended that the central corneal thickness and the thinnest point thickness measured by the two instruments be interchangeable in clinical use because of the wide range of consistency between the two instruments' results. The position of the thinnest corneal point measured by the two instruments is similar and consistent, so it could be considered to replace the measured values of the two instruments in clinical use.

2.
International Eye Science ; (12): 1036-1039, 2022.
Artigo em Chinês | WPRIM | ID: wpr-924228

RESUMO

@#AIM: To investigate the difference and consistency among iTrace, IOL Master 700 and Pentacam HR in measuring corneal astigmatism before cataract surgery.<p>METHODS: Across-sectional study. From May 2020 to May 2021, a total of 149 cataract patients(181 eyes)were collected in our hospital. Presurgery, steep keratometry(Ks), flat keratometry(Kf), mean keratometry(Km), astigmatism magnitude(Cyl), and steep astigmatic axis values measured by the three instruments of the iTrace, IOL Master 700 and the Pentacam HR. The difference and consistency of the measurement indexes of the three instruments were analyzed.<p>RESULTS: Statistical differences existed in Ks, Kf, Km among the three instruments(<i>F</i>=4.912, 3.514, 4.873, all <i>P</i><0.05)and there was no difference in Cyl and Axis(<i>F</i>=0.523, 0.128, all <i>P</i>>0.05). Bland-Altman analysis showed the outcomes revealed that the Ks and Kf measured by iTrace and the other two instruments have poor consistency, and the consistency of Cyl and Axis was good. But the difference of Axis is not clinically acceptable. There were no statistically differences between the iTrace and the other two devices among the low astigmatism(50 eyes), moderate astigmatism(34 eyes)and high astigmatism(18 eyes)groups(all <i>P</i>>0.05). <p>CONCLUSION: In the preoperative measurement of cataract patients except for the good consistency of astigmatism, the iTrace, IOL Master 700 and Pentacam HR showed different Ks and Kf, and the Axis difference exceeded the clinically acceptable range, especially in the highly astigmatism group. The measurement of corneal astigmatism before cataract surgery should be evaluated by multiple measurement methods and make comprehensive planning for the surgical plan.

3.
Indian J Ophthalmol ; 2014 Mar ; 62 (3): 367-370
Artigo em Inglês | IMSEAR | ID: sea-155578

RESUMO

Pellucid marginal degeneration (PMD) is an uncommon cause of inferior peripheral corneal thinning disorder, characterized by irregular astigmatism. We analyzed a case of bilateral PMD patient and treated one eye with corneal collagen cross-linking (CXL) therapy. Corneal topography was characteristic for PMD. Visual acuity, slitlamp examinations, tonometry, and corneal thickness were observed. Simulated keratometric and topographic index values were detected with corneal topography. Uncorrected, LogMAR visual acuity has improved from +0.8 to +0.55 during the 6 months and +0.3 during the 8 months followup after CXL. Pachymetry values and intraocular pressure showed no changes. Keratometric values and topografic indexes disclosed no progression of the disease. CXL may postpone or eliminate the need of corneal transplantation in cases with PMD.

4.
Journal of the Korean Ophthalmological Society ; : 1758-1764, 2014.
Artigo em Coreano | WPRIM | ID: wpr-140820

RESUMO

PURPOSE: To investigate the correlations of keratometry and corneal high order aberrations (HOAs) between the Keratron Scout videokeratoscope and the Pentacam HR Scheimpflug camera. METHODS: From December 2012 to February 2013, keratometry and corneal HOAs were determined using the Keratron Scout videokeratoscope and Pentacam HR Scheimpflug camera in 23 healthy individuals (46 eyes). RESULTS: Average keratometry showed high correlation with 95% confidence interval -0.155 +/- 0.37 between the Keratron Scout and Pentacam HR. When comparing HOAs of the Keratron Scout and total corneal HOAs of Pentacam HR, total root-mean-square (RMS), and spherical aberration were positively correlated between the 2 devices (r = 0.67, p < 0.001 and r = 0.74, p < 0.001, respectively). When comparing HOAs of Keratron Scout and anterior corneal HOAs of Pentacam HR, total RMS, spherical aberration and coma were positively correlated between the 2 devices (r = 0.62, p < 0.001, r = 0.81, p < 0.001, and r = 0.52, p = 0.047, respectively). CONCLUSIONS: Although the 2 devices are based upon different principles, the Keratron Scout videokeratoscope and Pentacam HR Scheimpflug camera showed positive correlations in keratometry, total RMS, spherical aberration, and coma. Both devices may be useful for clinical applications.


Assuntos
Coma
5.
Journal of the Korean Ophthalmological Society ; : 1758-1764, 2014.
Artigo em Coreano | WPRIM | ID: wpr-140817

RESUMO

PURPOSE: To investigate the correlations of keratometry and corneal high order aberrations (HOAs) between the Keratron Scout videokeratoscope and the Pentacam HR Scheimpflug camera. METHODS: From December 2012 to February 2013, keratometry and corneal HOAs were determined using the Keratron Scout videokeratoscope and Pentacam HR Scheimpflug camera in 23 healthy individuals (46 eyes). RESULTS: Average keratometry showed high correlation with 95% confidence interval -0.155 +/- 0.37 between the Keratron Scout and Pentacam HR. When comparing HOAs of the Keratron Scout and total corneal HOAs of Pentacam HR, total root-mean-square (RMS), and spherical aberration were positively correlated between the 2 devices (r = 0.67, p < 0.001 and r = 0.74, p < 0.001, respectively). When comparing HOAs of Keratron Scout and anterior corneal HOAs of Pentacam HR, total RMS, spherical aberration and coma were positively correlated between the 2 devices (r = 0.62, p < 0.001, r = 0.81, p < 0.001, and r = 0.52, p = 0.047, respectively). CONCLUSIONS: Although the 2 devices are based upon different principles, the Keratron Scout videokeratoscope and Pentacam HR Scheimpflug camera showed positive correlations in keratometry, total RMS, spherical aberration, and coma. Both devices may be useful for clinical applications.


Assuntos
Coma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA