Chinese Medical Equipment Journal ; (6): 54-56, 2018.
Artigo em Chinês | WPRIM | ID: wpr-699991

RESUMO

Objective To observe the effects of Class 5 and 6 chemical indicative cards used for monitoring pressure steam sterilization to standardize the procedure for selecting the monitoring substance of pressure steam sterilization. Methods Several pieces of Class 5 and 6 cards were placed at the four corners and center of the clave to undergo sterilization with the conventional parameters of 134 ℃, 240 s and 220 kPa as well as the simulation critical parameters of 134 ℃, 120 s and 220 kPa.The two kinds of cards had their qualification rates compared with two sets of parameters.SPSS 19.0 software was used for data analysis and Chi-square test was applied to comparison.Results The two kinds of cards had the qualification rates being 100% with the conventional parameters;with the simulation critical parameters,Class 5 card had the qualification rate being 100%,while Class 6 card had the rate of 66.67%,and there were significant difference between the qualification rates of the two cards(P<0.05).Conclusion Class 6 chemical indicative card has higher resistance and efficiency with the same conditions when compared with Class 5 card,which can be combined with the tube cavity challenger to execute mass monitoring with unstable parameters.

2.
China Medical Equipment ; (12): 39-41, 2017.
Artigo em Chinês | WPRIM | ID: wpr-667883

RESUMO

Objective: To explore the drying effect of pressure steam sterilization under different packing planes of non-woven fabrics so as to avoid the phenomenon of wet packages. Methods: 600 apparatus packages that packed by using non-woven fabrics were divided into A group(the packaging plane of apparatus bag used convex shape, that the center was higher and the periphery was lower), B group(The packaging plane of apparatus bag used horizontal shape) and C group (The packaging plane of apparatus bag used concave shape, that the center was lower and the periphery was higher)as random number table. All of the three groups adopted same package (the inner package was cotton and the outside package used non-woven fabrics of double-deck). Through pressure steam of impulse vacuum to achieve sterilization, and then the wet package rates of three groups were compared. Results: The wet package rates of the three groups were 1%, 8.5% and 37.5%, respectively, and the differences of wet package rates among the three groups were statistically significant (x2=10.135, P<0.05). Conclusion: The wet package rate of A group was lower than that of B group and C group, respectively. Therefore, this method of A group can ensure drying effect and guarantee the safety of clinical use.

3.
Modern Clinical Nursing ; (6): 26-29, 2017.
Artigo em Chinês | WPRIM | ID: wpr-686645

RESUMO

Objective To explore the effect of loading density of different rigid containers on wet package of orthopedic instruments in the department of orthopedics and to provide the basis for right loading of rigid container so as to ensure the success of the sterilization. Methods About 120 cases of orthopedic exotic instruments for knee surgery were selected from our hospital, according to size and weight of the knee surgery instrument and then evenly divided into Groups A, B, C, 40 pieces in each group. Each group for loading had the same length and width. In Group A, the loading was at 1/2 of the container height, in Group B, the loading was at 2/3 of the container height and in Group C the loading was 4/5 of the container height. The 3 groups were given high pressure steam sterilization, the sterilization temperature, sterilization time and drying time were the same, while biological and chemical monitoring was done. After sterilization, the three groups were compared in terms of the biological and chemical monitoring results as well as the incidence of wet pack. Results There were no significant differences between the 3 groups in the qualification rate of indicator cards and the biological monitoring after sterilization in the 5 kinds of packages among the 3 groups of rigid containers (P>0.05). The incidence of wet package in Group A was significantly lower than that of Group C (χ2=6.80, P=0.009<0.017), but no difference was found between Groups B and C ,Group B and C Group . Conclusions The loading density of different rigid containers affects the incidence of wet package of the orthopedic instruments. Our findings indicate that the loading of the instruments in a rigid container reaches the 2/3~4/5 height of the container, for it can reduce the incidence of wet package of orthopedic instruments.

4.
China Medical Equipment ; (12): 64-67, 2014.
Artigo em Chinês | WPRIM | ID: wpr-459335

RESUMO

Objective: Discuss different sterilization solution on the disinfection effect of fiberoptic bronchoscopy biopsy forceps. Methods:To ethylene oxide sterilization, glutaraldehyde immersion disinfection and high pressure steam sterilization of three methods of fiberoptic bronchoscopy biopsy forceps disinfection sterilization rate, the contamination rate and use fixed number of year for effect comparison. Results: Qualification rate of epoxy ethane sterilizing method were higher than in glutaraldehyde soaking method and high pressure steam sterilization disinfection method, and the pollution rate is significantly lower than the other two groups, the service life of the equipment increase. Conclusion:Low-temperature ethylene oxide sterilization of fiberoptic bronchoscopy biopsy forceps sterilization effect is good, and the pollution rate is low, service life is longer.

5.
Chinese Journal of Practical Nursing ; (36): 23-24, 2012.
Artigo em Chinês | WPRIM | ID: wpr-426974

RESUMO

ObjectiveTo observe the discoloration of chemical indicator cards in different positions in pressure steam sterilization bags and stetilization effect.MethodsFrom January 2009 to January 2011,168 packages needing sterilization were divided into group A and group B randomiy with 84 packages in each.We put chemical indicator cards on different positions in the packages.Then discoloration of chemical indicator cards and the qualified rate of bacteriology detection were observed.ResultsThere were 9cases of uneven discoloration in group A,and the incidence rate was 10.71%,higher than group B.The unqualified rate of bacteriology detection in group A was 2.38%,higher than group B(1.19%),but the difference was not statistically significant.ConclusionsChemical indicator cards could reflect the effect of sterilization,but placing them in different positions can appear different results.The chemical indicator cards that placed between the two packing layer could provide powerful evidence for sterilization effects for clinicians,and avoid unnecessary economic waste in Sterilization and Supply Center,which is worthy of being widely used in Sterilization and Supply Center.

6.
Chinese Journal of Nosocomiology ; (24)2006.
Artigo em Chinês | WPRIM | ID: wpr-593437

RESUMO

OBJECTIVE To observe and compare the application result of two kinds of chemical indicator(CI)card contained in high pressure-steam sterilization chemical monitoring testing package for providing correct credible evidence of supplying material in each batch after high pressure-steam sterilization and to avoid resource lost because of fault estimation.METHODS The chemical monitoring testing package was made according Sterilization Criteria published in 2002,with the 3M 1250 and 1243 CI cards and 1292 biology indicator(BI) to observe the results in tested package after sterilization.RESULTS The BI in chemical monitoring testing package was all qualified,the qualified rate of 1250 was 70%,while of 1243 was 100%.CONCLUSIONS If there is no BI for monitoring,1243 CI card should be chosen in high pressure-steam sterilization chemical monitoring testing package for supplying material in each batch after high pressure-steam sterilization which is not influenced by moisture and the contacted material and is easy to read and evaluate,the resource lost caused by fault estimation can be avoided.

7.
Chinese Journal of Nosocomiology ; (24)2006.
Artigo em Chinês | WPRIM | ID: wpr-586725

RESUMO

OBJECTIVE To investigate the expiry date of sterile articles packed by 4 different materials and preserved in different conditions after pressure steam sterilizing. METHODS The bacteria growth of the materials sterilized by pressure steam sterilizing method and stored in the supply department,treatment room,dressing room,nursing cabinet and ambulance vehicle was observed. RESULTS The axenic periods of the sterile materials in the supply department preserved by methods A,B,C,D were 14 days,14 days,7 months and 8 months,respectively in summer;while the sterile periods of the materials in the treatment room,dressing room,nursing cabinet and ambulance vehicle preserved by methods A,B,C,D were 11 days,11days,6 months and 7 months,respectively. CONCLUSIONS Management of expiry date of sterile materials is an important measure to guarantee safe use of sterile materials and prevent against nosocomial infection.

8.
Chinese Journal of Nosocomiology ; (24)2005.
Artigo em Chinês | WPRIM | ID: wpr-593189

RESUMO

OBJECTIVE To study the influence to the sterilizing effect of these factors,which were preheating the sterilizer,the positions of the articles placed and the cleanness of the internal wall.METHODS A total of 120 clinical used dental handpieces,according to the high-pressure steam sterilizer disposal procedure,were divided into four groups,with 30 handpieces in each group.Those only with high-pressure steam sterilizer process were chosen as the control group.Preheating 30 minutes,wipping the internal wall with 0.5% chlorine disinfectant before using high-pressure steam sterilizer and acting both of two steps were all chosen as the experimental groups.Each group was put in the interior,middle and exterior of the high-pressure steam sterilizer separately.The Rapid Readout Biological Indicators(3M Attest,the USA) were used to test the sterilizing effect.RESULTS The different methods of the high-pressure steam sterilizer had the significant differences to the handpieces sterilizing effect(P0.05).CONCLUSIONS To achieve ideal sterilization,it is suggested to wipe the internal wall and the temperature control probe head with 0.5% chlorine disinfectant and preheat the sterilizer for 30 minutes before put handpieces in the high-pressure steam sterilizer.

9.
Chinese Medical Equipment Journal ; (6)2003.
Artigo em Chinês | WPRIM | ID: wpr-587483

RESUMO

The weakness of the boiler high pressure steam sterilizer is put forward.The development process and actual application value of the hot steam electrical generator is mainly introduced.

10.
Chinese Journal of Nosocomiology ; (24)1994.
Artigo em Chinês | WPRIM | ID: wpr-588191

RESUMO

OBJECTIVE To study effective and convenient method for paraffin oil sterilization.METHODS By using carrier qualitative germicidal test,to compare pressure steam sterilization,dry heat sterilization and cobalt-60(gamma)-ray radiation sterilization to test the sterilizing effect and operating procedure.RESULTS Pressure steam sterilization was unable to achieve 100% sterilizing effect,whether we extended the time or use the intermittent(sterilization).After dry heat or radiation sterilization processes,no microorganism was found.CONCLUSIONS Effect of sterilization with dry heat or radiation sterilization is trustable,but its packing,operation and equipment are requested strictly,and pressure steam sterilization may be not good for paraffin oil.