Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
J. oral res. (Impresa) ; 12(1): 195-203, abr. 4, 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1516516

RESUMO

Aim: Correct orientation of the occlusal plane plays a vital role in achieving the perfect occlusal balance and function of complete dentures. This study aimed to evaluate the most reliable posterior reference point of the ala-tragus line (ATL) concerning occlusal plane (OP) in a sample of the dentate Sudanese population. Materials and Methods: A total of 150 subjects with healthy and well-aligned permanent teeth were randomly selected. Right lateral profile photographs were taken with subjects having a fox plane placed intra-orally, contacting the occlusal plane. Reference points corresponding to inferior, middle, and superior borders of the tragus and inferior border of the ala of the nose were marked on photographs. The angles between the lines were measured using the Auto-CAD software program, and the most parallel relationship was determined. Descriptive statistics in terms of means and standard deviations were presented. Independent t-test and one-way ANOVA tests were used to compare as appropriate. A p-value < 0.05 was considered significant. Results: The mean angle formed by the OP and ATL was 8.5±3.69º for the superior level, 4.68±3.13º for the middle line, and 2.89±2.57º for the inferior line. A significant difference was found between the means of the three angles (p< 0.001), while no significant difference (p> 0.05) was found between both genders regarding the measured angles. Conclusions: The line joining the inferior border of the ala of the nose with the inferior border of the tragus of the ear was the most reliable line in terms of parallelism to determine the occlusal plane orientation.


Antecedentes: La orientación correcta del plano oclusal juega un papel vital para lograr el equilibrio oclusal perfecto y la función de las prótesis completas. Este estudio tuvo como objetivo evaluar el punto de referencia posterior más confiable de la línea ala-trago (ATL) con respecto al plano oclusal (OP) en una muestra de la población dentada de Sudán. Materiales y Métodos: Se seleccionaron aleatoriamente un total de 150 sujetos con dientes permanentes sanos y bien alineados. Se tomaron fotografías de perfil lateral derecho de sujetos a los que se les colocó un plano de zorro intraoralmente, en contacto con el plano oclusal. En las fotografías se marcaron los puntos de referencia correspondientes a los bordes inferior, medio y superior del trago y al borde inferior del ala de la nariz. Los ángulos entre las líneas se midieron utilizando el programa de software Auto-CAD y se determinó la relación más paralela. Se presentaron estadísticas descriptivas en términos de medias y desviaciones estándar. Se utilizaron prueba-t independiente y prueba ANOVA unidireccional para las comparaciones, según correspondiera. Se consideró significativo un valor de p<0,05. Resultados: El ángulo medio formado por OP y ATL fue de 8,5±3,69º para el nivel superior, 4,68±3,13º para la línea media y 2,89±2,57º para la línea inferior. Se encontró una diferencia significativa entre las medias de los tres ángulos (p< 0,001), mientras que no se encontró diferencia significativa (p>0,05) entre ambos sexos con respecto a los ángulos medidos. Conclusión: La línea que une el borde inferior del ala de la nariz con el borde inferior del trago de la oreja fue la línea más confiable en términos de paralelismo para determinar la orientación del plano oclusal.


Assuntos
Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Pontos de Referência Anatômicos , Prostodontia , Sudão , Cefalometria , Estudos Transversais , Prótese Total
2.
Acta Paul. Enferm. (Online) ; 36: eAPE00662, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS, BDENF | ID: biblio-1439045

RESUMO

Resumo Objetivo Sumarizar as evidências científicas sobre os marcos anatômicos, na radiografia, utilizados para avaliar a ponta distal do cateter central de inserção periférica em recém-nascidos. Métodos Trata-se de uma revisão integrativa da literatura realizada nas bases de dados Web of Science, National Library of Medicine (PubMed/MEDLINE) e Scopus, entre os anos de 2017 e 2021. Resultados Dos 263 documentos encontrados nas bases, 13 preencheram os critérios de elegibilidade e foram selecionados para análise. Destes, 12 eram estudos observacionais e um experimental. Quanto ao país de origem, apenas um estudo foi publicado no Brasil, cinco na China, dois nos Estados Unidos da América e um estudo na Itália, Alemanha, Canadá, Irã e Índia. As evidências encontradas demonstraram a existência de sete marcos anatômicos utilizados na radiografia para visualização da ponta do cateter percutâneo em neonatos, sendo a unidade vertebral o referencial norteador predominante. Conclusão Para cateteres inseridos em membros superiores, os marcos anatômicos que mais se aproximam da junção cavo-atrial são a quinta e sétima vértebra torácica, ou duas unidades vertebrais abaixo da carina. Para os membros inferiores, o posicionamento da ponta do cateter deve estar entre a nona e décima vértebra torácica ou acima da quarta vértebra lombar.


Resumen Objetivo Sintetizar las evidencias científicas sobre los puntos anatómicos, en radiografías, utilizados para evaluar el extremo distal del catéter central de inserción periférica en recién nacidos. Métodos Se trata de una revisión integradora de la literatura realizada en las bases de datos Web of Science, National Library of Medicine (PubMed/MEDLINE) y Scopus, entre los años 2017 y 2021. Resultados De los 263 documentos encontrados en las bases, 13 cumplieron con los criterios de elegibilidad y fueron seleccionados para análisis. Entre ellos, 12 eran estudios de observación y uno era experimental. Con relación al país de origen, únicamente un estudio fue publicado en Brasil, cinco en China, dos en Estados Unidos de América y un estudio en Italia, Alemania, Canadá, Irán e India. Las evidencias encontradas demostraron la existencia de siete puntos anatómicos utilizados en la radiografía para la visualización de la extremidad del catéter percutáneo en neonatos, y la unidad vertebral fue el referente orientador predominante. Conclusión Para catéteres insertados en miembros superiores, los puntos anatómicos que más se aproximaron a la unión cavoatrial son la quinta y la séptima vértebra torácica o dos unidades vertebrales por debajo de la carina. Para los miembros inferiores, la ubicación de la extremidad del catéter debe estar entre la novena y la décima vértebra torácica o sobre la cuarta vértebra lumbar.


Abstract Objective To summarize the scientific evidence on anatomical landmarks on radiography used to evaluate the distal tip of the peripherally inserted central catheter in newborns. Methods This is an integrative literature review performed between 2017 and 2021 in Web of Science, National Library of Medicine (PubMed/MEDLINE) and Scopus databases. Results Thirteen out of 263 documents found in the databases met the eligibility criteria and were selected for analysis. Of these, 12 were observational studies and one was experimental. As for the country of origin, only one study was published in Brazil, five in China, two in the United States of America; and Italy, Germany, Canada, Iran and India with one study each. The evidence found demonstrated the existence of seven anatomical landmarks used in radiography to visualize the tip of the percutaneous catheter in newborns, and the vertebral body as the predominant guiding reference. Conclusion For catheters inserted in the upper limbs, the anatomical landmarks closer to the cavo-atrial junction are the fifth and seventh thoracic vertebrae, or two vertebral bodies below the level of the carina. For the lower limbs, the catheter tip should be positioned between the ninth and tenth thoracic vertebrae or above the fourth lumbar vertebra.

3.
Coluna/Columna ; 21(2): e263305, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1384654

RESUMO

ABSTRACT Objective: Rate and compare radiographic measurements of thoracic kyphosis and lumbar lordosis using anatomical and dynamic parameters. Methods: Measurements were performed on lateral radiographs of 10 adults of both sexes without spinal disease or deformity. Thoracic kyphosis and lumbar lordosis were measured using anatomical parameters (T1-T12, T4-T12, T5-T12 and L1-S1) or dynamic parameters (cervicothoracic or thoracolumbar inflection point). Results: Thoracic kyphosis and lumbar lordosis were different in 30% of subjects. Differences in thoracic kyphosis values were observed according to the anatomical reference used for measurement. Lumbar lordosis wasn`t statistical difference considering the anatomical or dynamic reference, but in 30% of the individuals the inflection point was different from the anatomical reference. Conclusions: Thoracic kyphosis and lumbar lordosis values differ according to anatomical and dynamic references. The reference used must be considered in the measurement and interpretation of values. Level of evidence IV; Case series.


RESUMO: Objetivo: Avaliar e comparar as mensurações radiográficas da cifose torácica e lordose lombar utilizando parâmetros anatômicos e dinâmicos. Métodos: As mensurações foram realizadas nas radiografias em perfil de 10 adultos de ambos os sexos sem doença ou deformidade da coluna vertebral. A cifose torácica e a lordose lombar foram mensuradas utilizando parâmetros anatômicos (T1-T12,T4-T12, T5-T12 e L1-S1) ou dinâmicos (ponto de inflexão cervicotorácico ou toracolombar) Resultados: As referências anatômicas e dinâmicas para a identificação da cifose torácica e lordose lombar foram diferentes em 30% dos indivíduos. Foi observado diferença dos valores da cifose torácica de acordo com a referência anatômica utilizada para a mensuração. A lordose lombar não apresentou diferença estatística considerando a referência anatômica ou dinâmica, mas em 30% dos indivíduos o ponto de inflexão era diferente da referência anatômica. Conclusões: Os valores da cifose torácica e lordose lombar apresentam diferenças de acordo com as referências anatômicas e dinâmicas. A referência utilizada deve ser considerada na mensuração e interpretação dos valores. Nível de evidência IV; Série de casos.


RESUMEN: Objetivo: Calificar y comparar medidas radiográficas de cifosis torácica y lordosis lumbar utilizando parámetros anatómicos y dinámicos. Métodos: Las mediciones se realizaron en radiografías laterales de 10 adultos de ambos sexos sin enfermedad o deformidad de la columna. La cifosis torácica y la lordosis lumbar se midieron mediante parámetros anatómicos (T1-T12, T4-T12, T5-T12 y L1-S1) o dinámicos (punto de inflexión cervicotorácico o toracolumbar). Resultados: La cifosis torácica y la lordosis lumbar fueron diferentes en el 30% de los sujetos. Se observaron diferencias en los valores de cifosis torácica según la referencia anatómica utilizada para la medición. La lordosis lumbar no fue diferencia estadística considerando la referencia anatómica o dinámica, pero en el 30% de los individuos el punto de inflexión fue diferente de la referencia anatómica. Conclusiones: Los valores de cifosis torácica y lordosis lumbar difieren según referencias anatómicas y dinámicas. La referencia utilizada debe ser considerada en la medición e interpretación de los valores. Nivel de evidencia IV; Series de casos.


Assuntos
Humanos , Adulto , Ortopedia
4.
Coluna/Columna ; 14(4): 317-319, Oct.-Dec. 2015. graf
Artigo em Inglês | LILACS | ID: lil-770238

RESUMO

Microsurgical landmarks of the facet joint complex were defined to provide guidance and security within the tubular retractor during transforaminal surgery. A retrospective observational study was performed in segments L4-L5 by the left side approach. Microsurgical relevant photos, anatomical models and drawing were used to expose the suggested landmarks. The MI-TLIF technique has advantages compared with conventional open TLIF technique, however minimally invasive technique implies lack of security for the surgeon due to the lack of defined microanatomical landmarks compared to open spine surgery, and disorientation within the tubular retractor, the reason why to have precise microsurgical references and its recognition within the surgical field provide speed and safety when performing minimally invasive technique.


Foram definidas referências anatômicas microcirúrgicas do complexo facetário para obter orientação e segurança no interior do retrator tubular durante a cirurgia transforaminal. Realizou-se um estudo observacional retrospectivo dos procedimentos MI-TLIF nos segmentos L4-L5 com acesso lateral esquerdo. Foram empregados fotos microcirúrgicas relevantes, modelo anatômico e esquemas para expor as referências sugeridas. A técnica de MI-TLIF tem vantagens quando comparada com a técnica TLIF a céu aberto convencional, no entanto, a técnica minimamente invasiva implica falta de segurança para o cirurgião, devido à ausência de referências microanatômicas definidas em comparação com a cirurgia a céu aberto, além de falta de orientação no interior do retrator tubular. Por isso, ter referências microcirúrgicas precisas e seu reconhecimento dentro do campo cirúrgico proporciona rapidez e segurança ao realizar a técnica minimamente invasiva.


Se definieron las referencias anatómicas microquirúrgicas del complejo facetario para aportar orientación y seguridad dentro del portal tubular durante la cirugía transforaminal. Se realizó un estudio observacional retrospectivo de procedimientos MI-TLIF en segmentos L4-L5 abordados del lado izquierdo. Se utilizaron fotos microquirúrgicas relevantes, modelo anatómico y esquemas para exponer las referencias anatómicas sugeridas. La técnica de MI-TLIF tiene ventajas comparada con la técnica abierta convencional de TLIF, sin embargo la técnica mínimamente invasiva confiere falta de seguridad para el cirujano debido a la carencia de referencias microanatómicas definidas comparado con la cirugía abierta y desorientación dentro del acceso tubular por lo que tener referencias microquirúrgicas precisas y su reconocimiento dentro del campo quirúrgico aportan rapidez y seguridad al realizar la técnica mínimamente invasiva.


Assuntos
Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Fusão Vertebral , Pontos de Referência Anatômicos , Vértebras Lombares
5.
Rev. biol. trop ; 60(3): 1249-1258, Sept. 2012. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-659585

RESUMO

Calliphoridae is one of the families with the greatest number of species with forensic importance, which immature stages feed and develop on decaying material. in Venezuela, there are few studies on this taxon reporting the dominance of Chrysomya over other carrion flies. The goal of this study was to analyze the variations on wing morphometrics, to support the identification of two forensic flies. For this we photographed a total of 168 wings from C. albiceps (n=111) and C. megacephala (n=57). Landmark coordinate (x, y) configurations were registered and aligned by Generalized Procrustes Analysis. Principal Component Analysis and shape significance test based on Procrustes distance were implemented. Statistical analysis of variance found significant differences in wing isometric size (Kruskal-Wallis). The PCA showed the separation between species, and shape test showed significant differences (F Goodall´s). The main differences between both species were localized on subcosta rupture, join of R2+3 with wing border, join of dm-cu, and join of Cu with bm-cu, suggesting that wing morphometrics is a suitable tool in the discrimination of blowfly species.


Calliphoridae es una de las familias con el mayor número de especies de importancia forense, donde sus fases inmaduras se alimentan y desarrollan sobre material en descomposición. En Venezuela, son pocos los estudios en este taxon, sin embargo se ha reportado la dominancia del género Chrysomya sobre los otros dípteros. El objetivo fue analizar la variación morfométrica en la arquitectura alar, como herramienta de apoyo a la identificación de dípteros de importancia forense. Se fotografiaron 168 alas de C. albiceps (n=111) y C. megacephala (n=57) y se registraron configuraciones de coordenadas (x, y), se alinearon mediante Análisis Generalizado de Procrustes. Se efectuaron Análisis de Componentes Principales y comparaciones pareadas entre distancia parcial de Procrustes. El análisis estadístico de varianza encontró diferencias en el tamaño isométrico del ala (Kruskal-Wallis). El ACP mostró la separación de ambas especies, y la prueba de configuraciones determinó diferencias significativas (F Goodall). Las principales diferencias entre ambas especies se encontraron en: ruptura de la subcosta, unión de R2+3 con el borde del ala, unión dm-cu, y unión de Cu con dm-cu, lo que confirma que la morfometría alar es una herramienta idónea en la discriminación de especies de Calliphoridae.


Assuntos
Animais , Bovinos , Ratos , Dípteros/anatomia & histologia , Dípteros/classificação , Asas de Animais/anatomia & histologia , Medicina Legal , Análise de Componente Principal , Ratos Sprague-Dawley , Venezuela
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA