Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Radiol. bras ; 55(1): 13-18, Jan.-Feb. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1360671

RESUMO

Abstract Objective: To compare 68Ga-DOTA-DPhe1,Tyr3-octreotate (68Ga-DOTATATE) positron-emission tomography/computed tomography (PET/CT) findings with those of conventional 111In-octreotide scintigraphy in patients with neuroendocrine tumors (NETs). Materials and Methods: This was a single-center prospective study including 41 patients (25 males; mean age, 55.4 years) with biopsy-proven NETs who underwent whole-body 111In-octreotide scintigraphy and whole-body 68Ga-DOTATATE PET/CT. The patients had been referred for tumor staging (34.1%), tumor restaging (61.0%), or response evaluation (4.9%). Images were compared in a patient-by-patient analysis to identify additional lesions, and we attempted to determine the impact that discordant findings had on treatment planning. Results: Compared with 111In-octreotide scintigraphy, 68Ga-DOTATATE PET/CT revealed more lesions, the additional lesions typically being in the liver or bowel. Changes in management owing to the additional information provided by 68Ga-DOTATATE PET/CT occurred in five patients (12.2%), including intermodal changes in three (7.3%) and intramodal changes in two (4.9%). In addition, 68Ga-DOTATATE PET/CT yielded incidental findings unrelated to the primary NET in three patients (7.3%): Hürthle cell carcinoma of the thyroid, bowel non-Hodgkin lymphoma, and a suspicious breast lesion. Conclusion: We conclude that 68Ga-DOTATATE PET/CT is superior to conventional 111In-octreotide scintigraphy for the management of NETs because of its ability to determine the extent of the disease more accurately, which, in some cases, translates to changes in the treatment plan.


RESUMO Objetivo: Comparar os achados da PET/CT com 68Ga-DOTATATE em relação aos da cintilografia com 111In-octreotide em pacientes com tumores neuroendócrinos (TNEs). Materiais e Métodos: Estudo prospectivo unicêntrico incluindo 41 pacientes (25 homens; média de idade: 55,4 anos) com TNEs comprovados por biópsia submetidos a cintilografia de corpo inteiro com 111In-octreotide e PET/CT com 68Ga-DOTATATE. Os pacientes incluídos foram encaminhados para estadiamento do tumor (34,1%), reestadiamento (61,0%) ou avaliação da resposta (4,9%). As imagens foram comparadas para identificar lesões adicionais e o impacto dos achados discordantes no planejamento terapêutico. Resultados: Na comparação com a cintilografia com 111In-octreotide, a PET/CT com 68Ga-DOTATATE revelou mais lesões, mais frequentemente localizadas no fígado e intestino. Mudanças no tratamento devidas às informações adicionais reveladas pela PET/ CT ocorreram em 5/41 pacientes (12,2%), incluindo mudanças intermodalidade em três casos (7,3%) e intramodalidade em dois casos (4,9%). A PET/CT também identificou achados incidentais não relacionados ao TNE em 3/41 pacientes (7,3%), incluindo um carcinoma de células de Hürthle da tireoide, um linfoma não Hodgkin de intestino e uma lesão mamária suspeita. Conclusão: A PET/CT com 68Ga-DOTATATE é superior à cintilografia convencional com 111In-octreotide para o manejo de pacientes com TNEs, em virtude da sua capacidade de detectar a extensão da doença com mais precisão, o que se traduz, em alguns casos, em alterações terapêuticas.

2.
Rev. argent. radiol ; 83(3): 102-112, set. 2019. ilus
Artigo em Espanhol | LILACS | ID: biblio-1057408

RESUMO

El intervencionismo en mama se inició con la localización preoperatoria de lesiones no palpables. En una segunda etapa, el desarrollo de técnicas de biopsias en las tres modalidades (mamografía, ultrasonido y resonancia magnética), reforzaron las indicaciones de localización de lesiones con histología ya confirmada. La técnica de localización en Argentina se basó casi exclusivamente en la inserción de alambres con arpones e inyección de carbón. A partir del año 2001, se ofreció como alternativa a las localizaciones con arpones la inserción de semilla de Iodo-125, considerando las ventajas para la paciente, el cirujano y el sistema hospitalario al desacoplar los turnos de quirófano y servicios de imágenes, otorgando acceso a cualquier cuadrante con incisiones cosméticas. La provisión del isótopo es la clave para instalar y atender la demanda de los usuarios, una vez que han conocido los méritos del procedimiento. En todos los ámbitos y distintos países, se verificó una lenta incorporación a la rutina de localización de lesiones con material radioactivo, primariamente por las regulaciones fundamentales y justificadas para la adquisición del isótopo. En nuestro medio y en una labor conjunta con la Autoridad Regulatoria Nuclear (ARN), logramos finalmente, en el año 2017, el reconocimiento de la práctica. Revisamos la bibliografía, describimos la técnica y la logística para lograr autorización de aquellos centros interesados en aplicar un procedimiento universalmente adoptado por sus ventajas respecto a los métodos tradicionales.


Diagnostic intervention in breast disease started with preoperative localization of non- palpable lesions. Later, with the histological diagnosis obtained through biopsy techniques in mammography, ultrasound and magnetic resonance imaging, the localization of lesions has become a must. Traditionally, in Argentina, the localization technique was exclusively based on the insertion of harpoon-shaped guided wires and carbon suspension. Since 2001, the iodine-125 radioactive seed localization has emerged as a reliable and advantageous alternative for the patient, the surgeon and the hospital system, reducing scheduling conflicts between the breast imaging department and the surgical department, and allowing access to any quadrant with cosmetic incisions. The isotope provision is the key to satisfying the users demand, once they have known the merits of the procedure. The implementation of radioactive material for the localization of lesions has been tardy in all fields and in different countries, mainly due to justified regulations related to the acquisition of the isotope. As a result of joint efforts with the Autoridad Regulatoria Nuclear (Nuclear Regulatory Authority), the practice finally gained its deserved recognition in 2017. We conducted a review of the existing literature and described the technique and the logistics to obtain the approval of the sites that were interested in the deployment of a widely used procedure that has proved to be more advantageous than traditional methods.


Assuntos
Humanos , Neoplasias da Mama/diagnóstico por imagem , Medicina Nuclear/métodos , Argentina , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia
3.
Int. j. cardiovasc. sci. (Impr.) ; 32(3): 302-309, May-June 2019. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1002221

RESUMO

This paper is about the Guideline for Ventilation / Perfusion Scintigraphy. It has been developed by the Brazilian Society of Nuclear Medicine to be a best practices guide used in Nuclear Medicine. Its function is to be an educational tool to help the Nuclear Medicine Services in Brazil to guarantee a quality care to the patients


Assuntos
Humanos , Masculino , Feminino , Relação Ventilação-Perfusão , Guias como Assunto/normas , Artéria Pulmonar/patologia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Cintilografia/métodos , Medicina Nuclear/normas
4.
Radiol. bras ; 51(6): 385-390, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-976753

RESUMO

Abstract Objective: To evaluate the use of pulmonary inhalation-perfusion scintigraphy as an alternative method of investigation and follow-up in patients with bronchopleural fistula (BPF). Materials and Methods: Nine patients with BPFs were treated through the off-label use of a transcatheter atrial septal defect occluder, placed endoscopically, and were followed with pulmonary inhalation-perfusion scintigraphy, involving inhalation, via a nebulizer, of 900-1300 MBq (25-35 mCi) of technetium-99m-labeled diethylenetriaminepentaacetic acid and single-photon emission computed tomography with a dual-head gamma camera. Results: In two cases, there was a residual air leak that was not identified by bronchoscopy or the methylene blue test but was detected only by pulmonary inhalation-perfusion scintigraphy. Those results correlated with the evolution of the patients, both of whom showed late signs of air leak, which confirmed the scintigraphy findings. In the patients with complete resolution of symptoms and fistula closure seen on bronchoscopy, the scintigraphy was completely negative. In cases of failure to close the BPF, the scintigraphy confirmed the persistence of the air leak. In two patients, scintigraphy was the only method to show residual BPF, the fistula no longer being seen on bronchoscopy. Conclusion: We found pulmonary inhalation-perfusion scintigraphy to be a useful tool for identifying a residual BPF, as well as being an alternative method of investigating BPFs and of monitoring the affected patients.


Resumo Objetivo: Avaliar a cintilografia por inalação-perfusão pulmonar como método alternativo de investigação e acompanhamento em pacientes com fístula broncopleural (FBP). Materiais e Métodos: Nove pacientes com FBPs foram tratados de forma endoscópica com o uso off label de um oclusor transcateter de defeito do septo interatrial e foram seguidos com cintilografia de inalação-perfusão pulmonar usando tomografia computadorizada por emissão de fóton único com câmera de cintilação de duas cabeças e inalação com 900-1300 MBq (25-35 mCi) de ácido dietilenotriaminopentacético marcado com tecnécio-99m, inserido num nebulizador. Resultados: Broncoscopia e teste de azul de metileno não foram capazes de detectar dois casos de vazamento residual, detectados apenas por cintilografia por inalação-perfusão pulmonar. Esses resultados foram correlacionados com a evolução desses pacientes que tardiamente apresentaram sinais de vazamento de ar confirmando os achados da cintilografia. Pacientes com resolução completa dos sintomas e com aspecto broncoscópico do fechamento da fístula apresentaram cintilografia negativa completa. Em casos de falha no fechamento da FBP, a cintilografia por inalação-perfusão confirmou a persistência da fuga de ar. Em dois pacientes, a cintilografia foi o único método a mostrar FBP residual, apesar da ausência da fístula por avaliação broncoscópica. Conclusão: Neste estudo, a cintilografia de inalação-perfusão pulmonar mostrou ser um instrumento útil para identificar FBP residual e como método alternativo de investigação e seguimento de pacientes com FBPs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA