Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Ultrasonography ; (12): 963-967, 2015.
Artigo em Chinês | WPRIM | ID: wpr-672291

RESUMO

Objective To evaluate the feasibility and therapeutic efficacy of real-time virtual navigation system (RVS) combined with contrast-enhanced ultrasonography (CEUS) for hepatocellular carcinoma undetectable by conventional ultrasound and CEUS.Methods A total of 213 patients with 265 lesions (undetectable on conventional ultrasound but detectable by other imaging examinations) were enrolled in this study.CEUS was performed,and lesions which were detected with CEUS were given CEUS guided radio-frequency ablation (RFA) (CEUS group).RVS combined with CEUS was performed to locate the rest lesions and guide RFA (RVS + CEUS group).Diagnostic value and therapeutic efficacy of RVS + CEUS were assessed.Results In 256 lesions,174 (65.7%) could be detected with CEUS,and among the rest 91 lesions,82 (90.1%) lesions could be detected by RVS combined with CEUS.The technique effectiveness rate of RVS + CEUS was significantly higher than that of CEUS (x2 =18.85,P <0.0001).Complete ablation rate after one month in RVS+ CEUS group was 9t.5% (75/82),which was significantly higher than that in CEUS group [86.2% (150/174),P <0.05].Local progression in one year in CEUS group and RVS + CEUS group were 13.4% and 10.9%,respectively.Conclusions RVS combined with CEUS is feasible for hepatocellular carcinoma undetectable by conventional ultrasonography and CEUS,and the therapeutic efficacy of RVS + CEUS guided RFA is satisfactory.

2.
Chinese Journal of Ultrasonography ; (12): 887-889, 2011.
Artigo em Chinês | WPRIM | ID: wpr-422684

RESUMO

ObjectiveTo verify the feasibility and the accuracy for the biopsy of targets not visible on sonography but shown on CT in a phantom by using real-time virtual navigation system(RVS).Methods The tissue mimicking phantom,made of gel,contained 30 red spheres which were 10 mm in diameter,randomly placed.These spheres were invisible on sonography,but visible on CT.A junior operator and a senior operator performed the biopsy respectively,and each sphere was biopsied once guide by both RVS and conventional ultrasound for each operator.The red dye in thebiopsied sample meant successful performance.The success rate of biopsy and the length of the red dyed sample were recorded.Results There was no statistically difference between the performance results of the two operators.The success rate and the median length of red dyed sample biopsy of RVS were respectively 96.7% (58/60) and 7.5 mm (rang,6-9 mm) which were statistically higher and longer than that of conventional ultrasound,43.3%(26/60) and 0 mm(rang,0 - 5 mm) ( P <0.05).ConclusionsBiopsy guided by RVS for the target invisible to ultrasound is a feasible and accuracy method,which will be a new guided method for interventional ultrasound.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA