Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 216-222, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1006866

RESUMO

Objective@#To explore an accurate method to obtain an intraoral model of patients with specific limited mouth opening (microstomia) due to systemic scleroderma.@*Methods@#This study followed medical ethics, and informed consent has been obtained from patients. A case of Ken's Type I mandibular dentition defect scleroderma with limited mouth opening was addressed with digital technology as the leading method combined with the traditional impression method of segmental impression. Individual trays were made based on the patient's left and right mandibular dentition, and segmented molds were obtained. Simultaneously, intraoral scanning was performed to obtain the morphological data of both the soft and hard tissues of the upper and lower mandibles. After each part of the model was obtained, the mandibular model was scanned and digitally aligned to form the final denture model, and the final removable partial denture was designed and made by computer aided design/computer aided manufacturing (CAD/CAM) technology. At the same time, combined with the literature, the diagnosis and treatment of removable partial denture in patients with limited mouth opening were retrospectively analyzed.@*Results@#The denture was well retained and achieved a good repair effect. The patients expressed satisfaction with the mastication efficiency and other functions of the denture. The findings of the literature review show that the integration of digital technology with the traditional impression method, along with computer fitting, can accurately obtain the patient's oral model and facilitate successful follow-up repairs. However, when the anterior mandibular dentition of the patient is absent, the margin of error is increased in this procedure, which deserves further exploration.@*Conclusion@#Utilizing digital technology as the leading method, combined with the traditional impression method of segmental impression, for the repair of dental defects in patients with limited mouth opening, has proven to be effective. Thus, patients report a positive medical experience with high satisfaction, indicating that this approach is worthy of clinical promotion.

2.
Rev. Odontol. Araçatuba (Impr.) ; 44(2): 24-29, maio-ago. 2023. ilus
Artigo em Português | LILACS, BBO | ID: biblio-1428024

RESUMO

As próteses parciais removíveis (PPRs) são uma alternativa de tratamento viável na prática clínica para reabilitar arcos parcialmente desdentados. Entretanto, o planejamento dessas próteses e preparo bucal prévio são frequentemente negligenciados. O presente artigo tem como objetivo relatar o caso clínico de uma reabilitação oral com PPRs superior e inferior após abordagem multidisciplinar, de modo a enfatizar as fases de um planejamento criterioso e de preparo prévio dos dentes pilares, visando o sucesso e a longevidade da reabilitação. Paciente do sexo masculino de 57 anos de idade compareceu à clínica da Faculdade de Odontologia de Bauru, Universidade de São Paulo, queixando-se da estética de seu sorriso e de algumas ausências dentárias. O indivíduo utilizava uma PPR provisória inferior insatisfatória e apresentava perda de dimensão vertical de oclusão (DVO). Após o exame clínico, radiográfico e estudo do caso em articulador semi-ajustável, realizou-se o planejamento com abordagens restauradoras, endodônticas, periodontais e protéticas. Após tratamento periodontal, foi realizada endodontia dos elementos 12, 15 e 47, confecção de núcleos e coroas nos dentes 12 e 15, restauração a nível gengival para apoio residual no dente 47, restaurações nos dentes 11, 13, 22, 24 e 44 e, por fim, a confecção das PPRs superior e inferior. A abordagem multidisciplinar utilizada neste caso clínico viabilizou o restabelecimento da DVO e possibilitou o sucesso da reabilitação protética(AU)


Removable partial dentures (RPDs) are a viable treatment alternative in clinical practice to rehabilitate partially edentulous arches. However, the planning of these dentures and prior oral preparation are often neglected. This article aims to report the clinical case of an oral rehabilitation with upper and lower RPDs after a multidisciplinary approach, to emphasize the phases of careful planning and prior preparation of the abutment teeth, aiming at the success and longevity of the rehabilitation. A 57-year-old male patient came to the clinic of the Bauru School of Dentistry, University of São Paulo, complaining about the esthetics of his smile and some missing teeth. The subject was using an unsatisfactory lower provisional prosthesis and had a loss of vertical dimension of occlusion (OVD). After the clinical and radiographic examination and the case study in a semi-adjustable articulator, planning was carried out with restorative, endodontic, periodontal and prosthetic approaches. After periodontal treatment, endodontics were performed on elements 12, 15 and 47, creation of cores and crowns on teeth 12 and 15, restoration at the gingival level for residual support on tooth 47, restorations on teeth 11, 13, 22, 24 and 44 and, finally, the making of the upper and lower PPRs. The multidisciplinary approach used in this clinical case enabled the restoration of the OVD and enabled the success of the oral rehabilitation(AU)


Assuntos
Humanos , Masculino , Adulto , Dimensão Vertical , Arcada Edêntula/terapia , Planejamento de Prótese Dentária , Prótese Parcial Removível , Dentaduras , Arcada Edêntula , Coroas , Estética Dentária
3.
Odontol. sanmarquina (Impr.) ; 26(2): e24770, Marzo 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1437079

RESUMO

Objetivo: El objetivo de este estudio fue desarrollar e implementar un software educativo bidimensional para el proceso de aprendizaje del diseño de Prótesis Parciales Removibles.Materiales y métodos: Se utilizó el método científico y procedimientos de evaluación educativa para abordar las necesidades de la asignatura de Prótesis Parcial Removible en la Facultad de Odontología de la UNMSM de Perú en el año 2022. Se utilizó análisis, síntesis y encuestas. Se examinó la aplicabilidad del software y el cumplimiento de los requerimientos de enseñanza y aprendizaje, no sólo en la UNMSM sino en cualquier universidad con requerimientos y características similares. Resultados: La aplicación in-terna del software arrojó un valor final del 96%, mientras que la evaluación de alumnos y docentes mostró un 90% de aceptación, al considerar que el SEDUPPR es sencillo para instalar, sencillo en su manejo y funcionamiento, y es muy útil para aprender diseño de PPR. Conclusiones: El software educativo bidimensional diseñado para el proceso de aprendizaje de Prótesis Parcial Removible es aplicable y puede ser implementado en diferentes ámbitos educativos.


Objective: The objective of this study was to develop and implement a two-dimensional educational software for the learning process of designing Removable Partial Prostheses.Materials and Methods: The scientific method and educational evaluation procedures were utilized to address the needs of the Removable Partial Prosthesis subject in the Fa-culty of Dentistry at the UNMSM in Peru in 2022. Analysis, synthesis, and surveys were used. The software's applicability and fulfillment of teaching and learning requirements were examined, not only at the UNMSM but also in any university with similar require-ments and characteristics. Results: The internal application of the software yielded a final value of 96%, while the evaluation of students and teachers showed a 90% acceptance rate, considering that SEDUPPR is simple to install, easy to use and operate, and is very useful for learn PPR design. Conclusion: The two-dimensional educational software designed for the learning process of Removable Partial Prosthesis is applicable and can be implemented in different educational settings.

4.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1442902

RESUMO

Objective: This study aims to compare the strain induced in the supporting structures of unilateral mandibular removable partial denture frameworks retained by extra-coronal attachments fabricated with three different materials. Material and Methods: Three mandibular class II digitally designed and printed acrylic models with detachable abutments were used to fabricate three removable partial denture framework with extra coronal attachments from three different materials. A total of 33 models were prepared for strain testing (n=11). Models were divided into three groups according to framework's material: porcelain fused to cobalt chromium (PFM), polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) group. Unilateral load of 60 N was applied in the three groups and strains were measured around the main abutment and saddle area using strain gauge. Results: Statistical analysis was performed using Shapiro-Wilk's test and by checking data distribution. Data were found to be non-parametric and were analysed using Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. PFM group showed significantly the highest strain values around abutment, slot 1 (1mm distal to the socket of the last abutment) and slot 2 (1 cm away from slot 1) respectively (843.00±23.08, 91.00±6.52 and 1274.00±65.71) than the other tested groups (p<0.05) at same tested sites respectively followed by PEKK group (384.00±37.48, 81.00±2.24 and 135.00±0.00) and PEEK group (29.00±4.18, 63.00±4.47 and 52.00±5.70). Conclusions: PEEK and PEKK for partial denture framework with extra coronal attachments are adequate alternative to PFM due to their good mechanical response applying less strain on supportive structures in free-end cases. PEEK induces lower strain magnitude on the supporting structures when compared to PEKK. (AU)


Objetivo: Este estudo tem como objetivo comparar a tensão induzida nas estruturas de suporte de estruturas de próteses parciais removíveis mandibulares unilateraisretidas por encaixes extracoronários fabricados com três materiais diferentes. Material e Métodos: Três modelos mandibulares de classe II digitalmente projetados e impressos em acrílico com pilares destacáveis foram usados para fabricar três estruturas de próteses parciais removíveis com encaixes extracoronários de três materiais diferentes. Um total de 33 modelos foram preparados para testes de deformação (n=11). Os modelos foram divididos em três grupos de acordo com o material da estrutura: porcelana fundida com cobalto-cromo (PFM), poliétercetonacetona (PEKK) e polieteretercetona (PEEK). Carga unilateral de 60 N foi aplicada nos três grupos e as deformações foram medidas em torno do pilar principal e área de sela usando medido de tensão. Resultados: A análise estatística foi realizada por meio do teste de Shapiro-Wilk e com a verificação da distribuição dos dados. Os dados mostraram-se não paramétricos e foram analisados pelo teste de Kruskal-Wallis seguido pelo de Dunn com correção de Bonferroni. O grupo PFM mostrou significativamente os maiores valores de tensão ao redor do pilar, slot 1 (1mm distal do último pilar) e slot 2 (1 cm de distância do slot 1) respectivamente (843,00±23,08, 91,00±6,52 e 1274,00±65,71) do que os outros grupos testados (p<0,05) nos mesmos locais testados, respectivamente, seguido pelo grupo PEKK (384,00±37,48, 81,00±2,24 e 135,00±0,00) e grupo PEEK (29,00±4,18, 63,00±4,47 e 52,00±5,70). Conclusão: PEEK e PEKK para estrutura de prótese parcial com encaixes extracoronários são alternativas adequadas ao PFM devido à sua boa resposta mecânica aplicando menos tensão nas estruturas de suporte em casos de extremidade livre. O PEEK induz menor magnitude de deformação nas estruturas de suporte quando comparado ao PEKK (AU)


Assuntos
Prótese Parcial , Prótese Parcial Removível , Encaixe de Precisão de Dentadura
5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 871-877, 2022.
Artigo em Chinês | WPRIM | ID: wpr-942640

RESUMO

Objective@# To investigate the effect of a metal occlusal surface and stress interruption design on minimally invasive prosthodontics for patients with distal extension absence and insufficient occlusal gingival distance.@*Methods @# We retrospectively studied the case of minimally invasive prosthodontic (Vitallium 2000) combined with a metal occlusal surface for distal extension absence in a patient with insufficient occlusal gingival distance; the stress breaking design and pressure impression technology are examined, and relevant articles are reviewd. @*Results@#The design effectively solves the problems of insufficient occlusal gingival distance, large occlusal force and easy denture fracture. Reviewing the relevant literature, stress interruption design can effectively protect abutment teeth, but the behavior of stress interruption design and stress conduction phenomena in the mouths of patients has not been reported. The T-scan test results of this study showed that before and after wearing the denture, the occlusal force distribution ratio of the patient changed from 77.5% on the left and 22.5% on the right to 61.3% on the left and 38.7% on the right. The occlusal force distribution ratio of the right dentition to the total occlusal force increased by 16.2%, and the occlusal force became better distributed. Further analysis showed that the occlusal forces on the left and right sides were nearly the same in the initial occlusion stage. As the occlusal force was further increased, the proportion of the occlusal force on the right side decreased in the middle of the occlusion stage and further decreased in the final occlusion stage until it reached a dynamic balance. The above T-scan test and literature review results suggest that this dynamic balance phenomenon of bite force is related to the stress interruption design and the stress conduction effect of the split framework.@* Conclusion @#The composite of stress interruption design and metal occlusal surface allows for minimally invasive prosthodontics for the treatment of distal extension absence in patients with insufficient occlusal gingival distance.

6.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 902-906, 2022.
Artigo em Chinês | WPRIM | ID: wpr-942768

RESUMO

@#Polyetheretherketone (PEEK) is known as a high-grade engineering plastic with good mechanical properties, chemical stability and biocompatibility. Currently, PEEK materials have been widely used in prosthodontics, such as complete dentures and removable partial dentures. The relevant research shows that PEEK posts are superior to glass fiber posts, which have high tensile bond strength and bending strength. At present, few case reports of PEEK postcores have been published, and clinical case reports suggest that PEEK postcores have good oral prosthetic aesthetics and are ideal and reliable postcore crown materials. However, the preparation and surface treatment methods of PEEK require further refinement. A review of the related properties of PEEK and the prospects of its application in the field of postcore crown restoration will be presented in this paper.

7.
Journal of Peking University(Health Sciences) ; (6): 406-412, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942195

RESUMO

OBJECTIVE@#To compare the differences and indications of three evaluation methods for fitness evaluation of removable partial denture (RPD).@*METHODS@#A RPD was fabricated and seated on the stone cast of a partially edentulous mandible, and the spaces between RPD and stone cast were recorded with polyvinyl siloxane (PVS) impression material forming PVS replicas. Using cross sectional measurement, the average thicknesses of PVS replicas were measured under stereomicroscope with different numbers of selected measuring points in the denture base, major connector, occlusal rest of the RPD, and the average thicknesses of the PVS replicas measured with different numbers of measuring points were compared using one-way analysis of variance (ANOVA) and independent sample t test. Three kinds of method, including cross sectional measurement, three-dimensional analysis on the stone cast, and three-dimensional analysis on the polyether cast, were applied to measure the average thicknesses of the PVS replicas, and the average thicknesses of the PVS replicas measured by these three evaluation methods were compared with ANOVA.@*RESULTS@#For cross sectional measurement, statistically significant differences were found in the average thicknesses of the PVS replicas in the denture base and the major connector among the different numbers of measuring points (P < 0.05), but no differences were found in the average thicknesses of the PVS replicas in the occlusal rest (P>0.05). There were significant differences among the average thicknesses of the PVS replicas measured by these three evaluation methods in each component of the RPD (P < 0.01). The average thickness measured by three-dimensional analysis on the stone cast and three-dimensional analysis on polyether cast were smaller than that measured by cross sectional measurement (P < 0.05). And there were no differences between the average thicknesses of PVS replicas measured by three-dimensional analysis on stone cast and three-dimensional analysis on polyether cast (P>0.05).@*CONCLUSION@#For cross sectional measurement, the average thickness of the PVS replicas was influenced by the number of measuring points, and the measurement accuracy of cross sectional measurement was not reliable enough. Three-dimensional analysis on stone cast which is suitable for evaluation in vitro and three-dimensional analysis on polyether cast which is suitable for evaluation in vivo can evaluate the fitness of RPD more comprehensively and effectively than that of cross sectional measurement.


Assuntos
Desenho Assistido por Computador , Estudos Transversais , Prótese Parcial Removível , Exercício Físico , Projetos de Pesquisa
8.
Archives of Orofacial Sciences ; : 49-55, 2021.
Artigo em Inglês | WPRIM | ID: wpr-962190

RESUMO

ABSTRACT@#Good denture hygiene is crucial for the prevention of various periodontal diseases, dental caries and dental stomatitis, which can give rise to a negative impact on the general health of denture users. A comparison exercise was conducted, to determine the effectiveness of information on denture care, provided by different groups of dental personnel. A self-administered and structured questionnaire was distributed to patients who attended Hospital USM’s dental clinics, from 2014 to 2019 based on the attendance register of the clinic. The denture hygiene status of 100 participants was assessed during the interview session. The results derived through the questionnaire revealed that 100% of the respondents, who received both verbal and written instructions, practiced good dental hygiene. It was observed that the most effective instructions received by the respondents were delivered by the dental specialists. Respondents, who clean their dentures with denture cleaning tablets, soap, or denture cleaning paste, were observed to possess better denture hygiene than those who do not. Also, respondents who visit their dentists once every six months for routine dental examinations boasted a higher percentage of good denture hygiene (81.8%). A positive association was perceived, between knowledge and the status of denture hygiene.

9.
The Journal of Korean Academy of Prosthodontics ; : 58-66, 2020.
Artigo em Coreano | WPRIM | ID: wpr-786591

RESUMO

Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.


Assuntos
Humanos , Coroas , Revestimento de Dentadura , Prótese Parcial Removível , Próteses e Implantes , Retenção da Prótese , Reabilitação , Dente
10.
West China Journal of Stomatology ; (6): 475-478, 2020.
Artigo em Chinês | WPRIM | ID: wpr-827510

RESUMO

This study aims to apply a new expert system to design removable partial denture (RPD) framework. The RPD design is completed in three steps, namely, "selecting missing teeth", "selecting abutment condition", and "selecting personalized clasp". The system can help auxiliary dentists develop personalized treatment plans to reduce their clinical workload. It can also generate a dental preparation guideline for clinical preparation, which can prevent tooth preparation mistakes. By generating the standard electronic drawings of the framework design, the system can reduce the inconvenience caused by manual drawing, thereby facilitating dentist-technician communication and reducing the rate of remade.


Assuntos
Dente Suporte , Planejamento de Dentadura , Prótese Parcial Removível , Sistemas Inteligentes , Dente
11.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 231-235, 2020.
Artigo em Chinês | WPRIM | ID: wpr-819108

RESUMO

Objective@#To investigate the effect of denture stomatitis of selective laser melting (SLM) titanium alloy for removable partial denture frameworks.@*Methods @#Twenty patients with dentition defects in our hospital were divided into two groups according to the different methods of creating a removable partial denture framework: the SLM group and casting group. The success rate, placement rate, masticatory efficiency and incidence of denture stomatitis were compared. Experimental data were analyzed with SPSS20.0.@*Results @# The success rate of the SLM framework group was 100.00%, which was higher than that of the casting group (90.00%) (P < 0.01). The rate of framework placement in the SLM group was slightly lower than that in the casting group (P < 0.05). The masticatory efficiency of the SLM group was higher than that of the casting group (0.783 ± 0.030 vs. 0.699 ± 0.037, P < 0.001). The incidence of denture stomatitis (10.00%) in the SLM group was significantly lower than that in the casting group (30.00%) (P < 0.001). @*Conclusion @#SLM is superior to the traditional casting method in mastication efficiency and reducing the incidence of denture stomatitis. This method can meet the clinical requirements, but the accuracy of the long-term stent needs to be improved.

12.
Chinese Journal of Tissue Engineering Research ; (53): 544-548, 2020.
Artigo em Chinês | WPRIM | ID: wpr-848136

RESUMO

BACKGROUND: There is no mature computer-aided design and manufacturing system for the preparation of removable partial denture in China so far. There is no report involving large sample size. Most of the existing studies only investigated the wear effect of a few cases, and there is a need to accumulate and enrich clinical data. OBJECTIVE: To explore the application value of intraoral scanning and 3D printing in the manufacture of removable partial dentures for patients. METHODS: Sixty-three patients with Kennedy class I dentition defect who received treatment in the Shanghai Ninth People’s Hospital, Shanghai JiaoTong University School of Medicine, China were included in this study. These patients consisted of 29 males and 34 females and were aged 44-63 years. In the study group, 23 patients were treated with denture scaffolds by intraoral scanning and three-dimensional printing, while in the control group, 40 patients were treated with denture scaffolds by traditional impression. The wear effect was compared between two groups after repair. The masticatory efficiency was compared between two groups before and 6, 12 and 24 months after repair. At the last follow-up, patients' satisfaction and complications were compared between the study and control groups. This study was approved by Shanghai Ninth People’s Hospital, Shanghai JiaoTong University School of Medicine (approval No. TJBDYY-2014-13-R1) in March, 2014. RESULTS AND CONCLUSION: The fitness (96% vs. 70%), retention (83% vs. 58%) and stability index (83% vs. 53%) of the study group were significantly higher than those of the control group (all P 0.05). At 12 and 24 months after repair, the masticatory efficiency in the study group was significantly higher than that in the control group (P 0.05). These results suggest that intraoral scanning and 3D printing could obtain a more accurate stent model in the manufacture of partial dentures compared with traditional impression, thereby has a higher application value.

13.
RGO (Porto Alegre) ; 68: e20200012, 2020. graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1101367

RESUMO

ABSTRACT This study aimed to report treatment of a patient with Kennedy's class l maxillary and class II mandibular arch with removable partial dentures supported on an external hexagon (HE) anterior type implant of regular diameter fitted with an O'ring type of attachment. This clinical case reports the oral rehabilitation of a senile patient whose clinical examination revealed missing dentition in the upper and lower arches, attrition of the lower anterior teeth, caries, and motor impairment affecting hygiene, mastication, and esthetic functions. Due to few severely impaired teeth, the pre-prosthetic preparation included extractions and restorations, followed by the fabrication of upper and lower removable partial dentures supported by an HE-type implant. This study is important because it addresses the current challenges faced in the implementation of treatment involving removable partial dentures combined with implants, which is a topic that still needs long-term follow-up and research.


RESUMO Este trabalho tem por objetivo relatar o tratamento reabilitador com próteses removíveis classe l de Kennedy superior e classe ll de Kennedy inferior associada a um implante de diâmetro regular, do tipo hexágono externo (HE) superior anterior, com o sistema de encaixe do tipo O'ring. O presente trabalho, relata um caso clínico em reabilitação oral em um paciente senil no qual apresentava ao exame clínico ausências dentárias no arco superior e inferior, desgaste por atrição nos dentes anteriores inferiores, cáries e comprometimento motor, prejudicando a higienização, função mastigatória e estética. Em virtude do grau de comprometimento de alguns dentes, o preparo pré-protético foi realizado com exodontias, restaurações e, por fim, a confecção de próteses parciais removíveis inferior e superior conjugada com um implante do tipo HE. O presente estudo é importante porque aborda os desafios atuais da implantação da prótese parcial removível combinada com o implante, um tema que ainda necessita de pesquisas de acompanhamento a longo prazo.

14.
Artigo | IMSEAR | ID: sea-202366

RESUMO

Introduction: Awareness among patients regarding use ofimplants is in need and for which effective and adequatecommunication is vital. Aims and Objectives: To gauge theawareness and knowledge regarding dental implants as anoption of treatment to replace missing teeth among patients inHyderabad, India.Material and Methods: A standardized self- explanatoryquestionnaire was prepared and distributed in five dentalclinics of Hyderabad. The questionnaires were handed tothe patients during their regular dental visits. A total of 450subjects were included in this survey.Results: We found that 62.5% (250) patients had someknowledge about dental implants. The main source ofinformation regarding dental implants was form their friendsand relatives (35%; 140 subjects) and dentists being thesecondary source for 30% (120) of the sample. The majorhindering factor that prevents patients from choosing implantswas cost effectiveness in 87.5% (350) of the cases.Conclusion: The awareness and knowledge about dentalimplants in the subjects were acceptable among a selectedsample of dental patients in Hyderabad, India. Still there is aneed for providing more general and accurate information tothe patients about this latest treatment modality

15.
The Journal of Korean Academy of Prosthodontics ; : 42-48, 2019.
Artigo em Coreano | WPRIM | ID: wpr-719551

RESUMO

In the case of a patient with a small number of unilateral remaining teeth in the mandible, a restoration with conventional removable partial denture cannot provide sufficient retention and resistance. A harmful stress from the poor stability of denture on remaining teeth occurs due to alveolar bone resorption in edentulous area. Although implant fixed prosthesis can provide multiple benefits over conventional removable partial denture, there are limitations come from anatomic structures and costs. In this case, an implant-assisted removable partial denture (IARPD) with a couple of implants placed in strategic positions can be a treatment modality. The objective of this article is to present a case report of two patients showed satisfactory clinical outcomes during three-year follow-up period describing the fabrication and advantages of removable partial denture assisted by teeth and implants (IARPD) for a patient with a small number of unilateral remaining teeth in mandible using Locator as an implant attachment.


Assuntos
Humanos , Reabsorção Óssea , Prótese Parcial Removível , Dentaduras , Seguimentos , Mandíbula , Próteses e Implantes , Reabilitação , Dente
16.
The Journal of Korean Academy of Prosthodontics ; : 57-65, 2019.
Artigo em Coreano | WPRIM | ID: wpr-719549

RESUMO

Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.


Assuntos
Humanos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Odontologia , Prótese Parcial Removível , Restaurações Intracoronárias , Reabilitação Bucal , Boca , Próteses e Implantes , Dente , Fluxo de Trabalho
17.
The Journal of Korean Academy of Prosthodontics ; : 490-494, 2019.
Artigo em Coreano | WPRIM | ID: wpr-761441

RESUMO

Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.


Assuntos
Humanos , Coroas , Cárie Dentária , Prótese Parcial Removível , Próteses e Implantes , Dente
18.
The Journal of Korean Academy of Prosthodontics ; : 254-262, 2019.
Artigo em Coreano | WPRIM | ID: wpr-761432

RESUMO

As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.


Assuntos
Humanos , Masculino , Prótese Parcial Removível , Dentaduras , Esperança , Programas Nacionais de Saúde , Próteses e Implantes , Dente
19.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 369-373, 2019.
Artigo em Inglês | WPRIM | ID: wpr-786152

RESUMO

This paper describes a patient with an insufficient vestibular depth for a removable partial denture who underwent vestibuloplasty with a free gingival graft using a titanium mesh in the anterior mandible. Free gingiva was harvested from the palatal mucosa, and a partial thickness flap was elevated at the recipient site. After minimal suturing for the graft, a titanium mesh was fixed over the graft. The mesh was removed four weeks after surgery. The patient obtained an adequate vestibular depth and keratinized gingiva eight weeks after surgery without any complications. In this case, an appropriate vestibular depth and keratinized gingiva were easily obtained by vestibuloplasty using a titanium mesh.


Assuntos
Humanos , Prótese Parcial Removível , Gengiva , Mandíbula , Mucosa , Titânio , Transplantes , Vestibuloplastia
20.
The Journal of Korean Academy of Prosthodontics ; : 176-181, 2019.
Artigo em Coreano | WPRIM | ID: wpr-742100

RESUMO

Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may be lowered due to patient's discomfort and damage of the abutment. Recently, it has been reported that the unilateral posterior extension partial denture is used as a bilateral posterior extension partial denture using implant fixed prostheses as abutments. In this case, by using implant surveyed crown prostheses, bilateral posterior extension partial denture is fabricated in site that is predicted to have a poor prognosis. This resulted in improved support, maintenance, and stabilization of the removable partial denture, which were economically beneficial to patient and satisfied with use.


Assuntos
Humanos , Coroas , Prótese Parcial , Prótese Parcial Removível , Prognóstico , Próteses e Implantes , Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA