Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 385-390, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932615

RESUMO

Objective:To conduct radiation detection and dose assessment in selective internal radiotherapy with 90Y resin microspheres for the purpose of providing a reference for radiological protection. Methods:The dose rates from radiotherapy with 90Y resin microspheres were detected in the process of each operation at different distances from the body surface of patients the levels of dose to the persons concerned were compared with the relevant national regulations and standards. Results:The estimated dose rates were 1.12-454 μSv/h during 90Y resin microspheres dispensing and 2.06-58.2 μSv/h during surgical procedure. The dose rates at 0.5 h after surgery were 22.7-64.1 μSv/h at 5 cm and 0.82-2.55 μSv/h at 1 m from three patient′s body surface. Assuming treating 200 patients a year, the annual individual effective dose to the radiation workers was 0.12-1.03 mSv/year. The annual individual effective dose to the public, comforters and carers of patients was 0.02-0.24 mSv/year after release of a patient. Conclusions:During the treatment, nursing and release of patients, the radiation doses to workers, carers and the public are lower than the individual dose limit given in the GB18871-2002 basic standards for protection against ionizing radiation and for the safety of radiation sources and the management target value set by of the relevant medical institutions.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 460-463, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956807

RESUMO

Objective:To evaluate 90Y activity concentration in renal excretions during the first 48 hours after being treated with 90Y resin microspheres seleceive internal radiation therapy(SIRI) and to provide advice on the management of patient excreta after surgery. Methods:After surgery, urine excreted from 3 patients during 0-24 h and 24-48 h was collected respectively, and the 90Y activity concentration in urine was tested and analyzed. Results:90Y radioctivity in the urine excreted from 3 patients after surgery was (1 266±258)kBq/GBq during 0-24 h and (140±106) kBq/GBq during 24-48 h, respectively, and 90Y activity concentration were (640±113) kBq/L during 0-24 h and (53±12) kBq/L during 24-48 h. Conclusions:90Y radioactivity in patient′s urine excreted at 1 d was about 10 times higher than that at 2 d. After surgery, patients can accelerate the reduction of free 90Y activity by increasing excretion. Urine excreted by the patients during hospitalization should be handled in accordance with the requirements of the national standard HJ 1188-2021 Radiation protection and safety requirements for nuclear medicine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA