Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Crit. Care Sci ; 36: e20240158en, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557677

RESUMO

ABSTRACT Objective: To evaluate the association of biomarkers with successful ventilatory weaning in COVID-19 patients. Methods: An observational, retrospective, and single-center study was conducted between March 2020 and April 2021. C-reactive protein, total lymphocytes, and the neutrophil/lymphocyte ratio were evaluated during attrition and extubation, and the variation in these biomarker values was measured. The primary outcome was successful extubation. ROC curves were drawn to find the best cutoff points for the biomarkers based on sensitivity and specificity. Statistical analysis was performed using logistic regression. Results: Of the 2,377 patients admitted to the intensive care unit, 458 were included in the analysis, 356 in the Successful Weaning Group and 102 in the Failure Group. The cutoff points found from the ROC curves were −62.4% for C-reactive protein, +45.7% for total lymphocytes, and −32.9% for neutrophil/lymphocyte ratio. These points were significantly associated with greater extubation success. In the multivariate analysis, only C-reactive protein variation remained statistically significant (OR 2.6; 95%CI 1.51 - 4.5; p < 0.001). Conclusion: In this study, a decrease in C-reactive protein levels was associated with successful extubation in COVID-19 patients. Total lymphocytes and the neutrophil/lymphocyte ratio did not maintain the association after multivariate analysis. However, a decrease in C-reactive protein levels should not be used as a sole variable to identify COVID-19 patients suitable for weaning; as in our study, the area under the ROC curve demonstrated poor accuracy in discriminating extubation outcomes, with low sensitivity and specificity.


RESUMO Objetivo: Avaliar a associação de biomarcadores com o sucesso do desmame ventilatório em pacientes com COVID-19. Métodos: Trata-se de estudo observacional, retrospectivo e de centro único realizado entre março de 2020 e abril de 2021. Foram avaliados a proteína C-reativa, os linfócitos totais e a relação neutrófilos/linfócitos durante o atrito e a extubação; mediu-se a variação desses valores de biomarcadores. O desfecho primário foi o sucesso da extubação. As curvas ROC foram desenhadas para encontrar os melhores pontos de corte dos biomarcadores segundo a sensibilidade e a especificidade. A análise estatística foi realizada por meio de regressão logística. Resultados: Dos 2.377 pacientes admitidos na unidade de terapia intensiva, 458 foram incluídos na análise, 356 no Grupo Sucesso do desmame e 102 no Grupo Fracasso do desmame. Os pontos de corte encontrados nas curvas ROC foram −62,4% para proteína C-reativa, +45,7% para linfócitos totais e −32,9% para relação neutrófilo/linfócito. Esses pontos foram significativamente associados ao maior sucesso da extubação. Na análise multivariada, apenas a variação da proteína C-reativa permaneceu estatisticamente significativa (RC 2,6; IC95% 1,51 - 4,5; p < 0,001). Conclusão: Neste estudo, uma diminuição nos níveis de proteína C-reativa foi associada ao sucesso da extubação em pacientes com COVID-19. Os linfócitos totais e a relação neutrófilos/linfócitos não mantiveram a associação após a análise multivariada. No entanto, uma diminuição nos níveis de proteína C-reativa não deve ser usada como única variável para identificar pacientes com COVID-19 adequados para o desmame; como em nosso estudo, a área sob a curva ROC demonstrou baixa precisão na discriminação dos resultados de extubação, com baixas sensibilidade e especificidade.

2.
Biomédica (Bogotá) ; 43(Supl. 1): 181-193, ago. 2023.
Artigo em Espanhol | LILACS | ID: biblio-1533903

RESUMO

Introducción. La colonización por microorganismos patógenos de los dispositivos médicos usados en las unidades de cuidados intensivos es un factor de riesgo para el aumento de infecciones asociadas con la atención en salud y, por lo tanto, al de la morbilidad y la mortalidad de los pacientes intubados. En Colombia, no se ha descrito la colonización por hongos de los tubos endotraqueales, con lo cual se podrían considerar nuevas opciones terapéuticas para el beneficio de los pacientes. Objetivo. Describir los hongos que colonizan los tubos endotraqueales de los pacientes en unidades de cuidados intensivos, junto con su perfil de sensibilidad a los antifúngicos. Materiales y métodos. Se realizó un estudio observacional, descriptivo, en dos centros hospitalarios durante 12 meses. Se recolectaron tubos endotraqueales de pacientes de las unidades de cuidados intensivos. Estos fueron procesados para cultivar e identificar hongos, y para establecer su perfil de sensibilidad a los antifúngicos. Resultados. Se analizaron 121 tubos endotraqueales obtenidos de 113 pacientes. De estos, el 41,32 % se encontró colonizado por los hongos Candida albicans (64,61 %), C. no-albicans (30,77 %), Cryptococcus spp. (3,08 %) o mohos (1,54 %). Todos los hongos evaluados presentaron una gran sensibilidad a los antifúngicos, con un promedio del 91 %. Conclusión. Se encontró colonización fúngica en los tubos endotraqueales de pacientes con asistencia respiratoria mecánica. El perfil de sensibilidad en estos pacientes fue favorable. Se requiere un estudio clínico para correlacionar los microorganismos colonizadores y su capacidad de generar infección.


Introduction. Medical device colonization by pathogenic microorganisms is a risk factor for increasing infections associated with health care and, consequently, the morbidity and mortality of intubated patients. In Colombia, fungal colonization of endotracheal tubes has not been described, and this information could lead to new therapeutic options for the benefit of patients. Objective. To describe the colonizing fungi of the endotracheal tubes from patients in the intensive care unit, along with its antifungal sensitivity profile. Materials and methods. We conducted a descriptive, observational study in two health centers for 12 months. Endotracheal tubes were collected from patients in intensive care units. Samples were processed for culture, fungi identification, and antifungal sensitivity profile assessment. Results. A total of 121 endotracheal tubes, obtained from 113 patients, were analyzed: 41.32 % of the tubes were colonized by Candida albicans (64.62%), C. non-albicans (30.77%), Cryptococcus spp. (3.08%) or molds (1.54%). All fungi evaluated showed a high sensitivity to antifungals, with a mean of 91%. Conclusion. Fungal colonization was found in the endotracheal tubes of patients under invasive mechanical ventilation. The antifungal sensitivity profile in these patients was favorable. A clinical study is required to find possible correlations between the colonizing microorganisms and infectivity.


Assuntos
Microbiota , Intubação Intratraqueal , Pneumonia Associada à Ventilação Mecânica , Micobioma , Unidades de Terapia Intensiva
3.
Medicina (B.Aires) ; 83(2): 219-226, jun. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1448624

RESUMO

Resumen Introducción: Alrededor del 50% de los pacientes hos pitalizados por injuria cerebral adquirida grave requie ren traqueostomía y cuidados a largo plazo. El objetivo principal de este estudio fue describir la evolución de enfermos con injuria cerebral adquirida grave (ICAg) traqueostomizados que ingresaron a rehabilitación. Se cundariamente se estudió el fracaso de la decanulación y la supervivencia a los 12 meses del alta. Métodos: estudio cuantitativo observacional prospec tivo de centro único. Se incorporó al estudio, de forma prospectiva y consecutiva, usuarios mayores de 18 años, traqueostomizados posterior a ICAg ingresados a un cen tro de rehabilitación entre abril de 2018 y marzo de 2020. Resultados: se incluyeron para el análisis 50 pacien tes. La estancia en el centro fue de 203 (RIQ 93-320) días. Al alta de la institución, 32 (64%) pacientes pudieron ser decanulados exitosamente. El tiempo transcurrido desde el ingreso al centro hasta la decanulación fue de 49 (12-172) días. No se observó fracaso de la decanula ción. La mortalidad a los 12 meses de seguimiento fue de 32%, cinco (16%) de los 32 pacientes que pudieron ser decanulados y 11 (61%) de los 18 que no lograron la decanulación fallecieron dentro de los 12 meses de seguimiento. La relación entre la decanulación y la mortalidad a los 12 meses de seguimiento resultó esta dísticamente significativa (p = 0.002). Discusión: La supervivencia global fue relativamente elevada, el proceso de decanulación resulta relevante ya que puede tener impacto en la supervivencia a largo plazo.


Abstract Introduction: About 50% of patients hospitalized for severe acquired brain injury require tracheostomy, and many of them need long-term care. The main objective of this study was to describe the evolution of patients with severe acquired brain injury (sABI) tracheotomized who entered rehabilitation. Secondarily, mortality re lated to the success or failure of decannulation and survival at 12 months of discharge were studied. Methods: A single-center prospective observational quantitative study. Users over 18 years of age were recruited prospectively and consecutively, tracheosto mized after sABI, and admitted to a rehabilitation center between April 2018 and March 2020. Results: Fifty patients were included for analysis. The stay in the center was 203 (RIQ 93-320) days. At discharge to the institution, 32 (64%) patients managed to be successfully decannulated. The median number of days from admission to the center to decannulation was 49 (12-172). No decannulation failure was observed. Mortality at 12 months follow-up was 32%, five (16%) of the 32 patients who managed to be decannulated, and 11 (61%) of 18 who failed to achieve decannulation died within 12 months of follow-up. The relationship between decannulation success and mortality at 12 months of follow-up was statistically significant (p= 0.002). Discussion: Addressing the decannulation process early and properly guided is relevant as it may impact long-term survival.

4.
Crit. Care Sci ; 35(1): 44-56, Jan. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448080

RESUMO

ABSTRACT Objective: To investigate whether protocol-directed weaning in neurocritical patients would reduce the rate of extubation failure (as a primary outcome) and the associated complications (as a secondary outcome) compared with conventional weaning. Methods: A quasi-experimental study was conducted in a medical-surgical intensive care unit from January 2016 to December 2018. Patients aged 18 years or older with an acute neurological disease who were on mechanical ventilation > 24 hours were included. All patients included in the study were ready to wean, with no or minimal sedation, Glasgow coma score ≥ 9, spontaneous ventilatory stimulus, noradrenaline ≤ 0.2μgr/kg/ minute, fraction of inspired oxygen ≤ 0.5, positive end-expiratory pressure ≤ 5cmH2O, maximal inspiratory pressure < -20cmH2O, and occlusion pressure < 6cmH2O. Results: Ninety-four of 314 patients admitted to the intensive care unit were included (50 in the Intervention Group and 44 in the Control Group). There was no significant difference in spontaneous breathing trial failure (18% in the Intervention Group versus 34% in the Control Group, p = 0.12). More patients in the Intervention Group were extubated than in the Control Group (100% versus 79%, p = 0.01). The rate of extubation failure was not signifiantly diffrent between the groups (18% in the Intervention Group versus 17% in the Control Group; relative risk 1.02; 95%CI 0.64 - 1.61; p = 1.00). The reintubation rate was lower in the Control Group (16% in the Intervention Group versus 11% in the Control Group; relative risk 1.15; 95%CI 0.74 - 1.82; p = 0.75). The need for tracheotomy was lower in the Intervention Group [4 (8%) versus 11 (25%) in the Control Group; relative risk 0.32; 95%CI 0.11 - 0.93; p = 0.04]. At Day 28, the patients in the Intervention Group had more ventilator-free days than those in the Control Group [28 (26 - 28) days versus 26 (19 - 28) days; p = 0.01]. The total duration of mechanical ventilation was shorter in the Intervention Group than in the Control Group [5 (2 - 13) days versus 9 (3 - 22) days; p = 0.01]. There were no diffrences in the length of intensive care unit stay, 28-day free from mechanical ventilation, hospital stay or 90-day mortality. Conclusion: Considering the limitations of our study, the application of a weaning protocol for neurocritical patients led to a high percentage of extubation, a reduced need for tracheotomy and a shortened duration of mechanical ventilation. However, there was no reduction in extubation failure or the 28-day free of from mechanical ventilation compared with the Control Group. ClinicalTrials.gov Registry:NCT03128086


RESUMO Objetivo: Investigar se o desmame por protocolo em pacientes neurocríticos reduz a taxa de falha de extubação (desfecho primário) e as complicações associadas (desfecho secundário) em comparação com o desmame convencional. Métodos: Realizou-se um estudo quase experimental em uma unidade de terapia intensiva médico-cirúrgica de janeiro de 2016 a dezembro de 2018. Foram incluídos pacientes com 18 anos de idade ou mais, com doença neurológica aguda e em ventilação mecânica > 24 horas. Todos os pacientes incluídos no estudo estavam prontos para o desmame, com nenhuma ou mínima sedação, escala de coma de Glasgow ≥ 9, estímulo ventilatório espontâneo, noradrenalina ≤ 0,2μgr/kg/minuto, fração inspirada de oxigênio ≤ 0,5, pressão expiratória positiva final ≤ 5cmH2O, pressão inspiratória máxima < -20cmH2O e pressão de oclusão < 6cmH2O. Resultados: Foram incluídos 94 dos 314 pacientes admitidos à unidade de terapia intensiva, sendo 50 no Grupo Intervenção e 44 no Grupo Controle. Não houve diferença significativa na falha do ensaio respiratório espontâneo (18% no Grupo Intervenção versus 34% no Grupo Controle, p = 0,12). Foram extubados mais pacientes no Grupo Intervenção do que no Controle (100% versus 79%; p = 0,01). A taxa de falha de extubação não foi significativamente diferente entre os grupos (18% no Grupo Intervenção versus 17% no Grupo Controle, risco relativo de 1,02; IC95% 0,64 - 1,61; p = 1,00). A taxa de reintubação foi menor no Grupo Controle (16% no Grupo Intervenção versus 11% no Grupo Controle; risco relativo de 1,15; IC95% 0,74 -1,82; p = 0,75). A necessidade de traqueotomia foi menor no Grupo Intervenção [4 (8%) versus 11 (25%) no Grupo Controle; risco relativo de 0,32; IC95% 0,11 - 0,93; p = 0,04]. Aos 28 dias, os pacientes do Grupo Intervenção tinham mais dias sem ventilador do que os do Grupo Controle [28 (26 - 28) dias versus 26 (19 - 28) dias; p = 0,01]. A duração total da ventilação mecânica foi menor no Grupo Intervenção do que no Controle [5 (2 - 13) dias versus 9 (3 - 22) dias; p = 0,01]. Não houve diferenças no tempo de internação na unidade de terapia intensiva, 28 dias sem ventilação mecânica, internação hospitalar ou mortalidade em 90 dias. Conclusão: Considerando as limitações de nosso estudo, a aplicação de um protocolo de desmame em pacientes neurocríticos levou à maior proporção de extubação, à menor necessidade de traqueotomia e à menor duração da ventilação mecânica. Entretanto, não houve redução na falha de extubação ou 28 dias sem ventilação mecânica em comparação com o Grupo de Controle. Registro ClinicalTrials.gov:NCT03128086

5.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 41: e2021382, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1441057

RESUMO

Abstract Objective: This study aimed to investigate whether neonatal intensive care units (NICUs) in Brazilian hospitals use a protocol for weaning from noninvasive ventilation (NIV), how this ventilatory support is withdrawn, and whether there is consensus among the methods used by the institutions. Methods: A cross-sectional survey was conducted from December 2020 to February 2021, based on responses to an electronic questionnaire, filled out by physical therapists working in NICU in Brazilian hospitals about the routine of physical therapy and the use of NIV and its weaning. Results: A total of 93 answers to the electronic questionnaire met the study criteria: 52.7% were from public health institutions, with an average of 15 NICU beds (15.2±15.9), 85% of the physical therapists worked exclusively in the NICU, 34.4% of the NICU had 24-h physical therapy care, 66.7% of the units use the continuous positive airway pressure (CPAP) as ventilatory mode, and 72% the nasal prong as NIV interface; 90% of the NICU physical therapists answered that their NICU had no NIV weaning protocol, with various methods of weaning reported, the most cited being pressure weaning. Conclusions: Most Brazilian NICUs have no NIV weaning protocol. The most used method among institutions, with or without a protocol, is pressure weaning. Although most of the participating physical therapists work exclusively in NICU, many hospitals do not have the recommended workload, which can be one of the negative factors in the organization of protocols and in the progress of ventilatory weaning.


RESUMO Objetivo Investigar se as unidades de terapia intensiva neonatal (UTIN) dos hospitais brasileiros utilizam protocolo para desmame de ventilação não invasiva (VNI), de que forma é realizada a retirada desse suporte ventilatório e se há consenso entre os métodos utilizados pelas instituições. Métodos Foi realizado um estudo de corte transversal de dezembro de 2020 a fevereiro de 2021, com base nas respostas a um questionário eletrônico, preenchidas por fisioterapeutas que trabalham em UTIN de hospitais brasileiros sobre a rotina da fisioterapia, o uso de VNI e seu desmame. Resultados Preencheram os critérios do estudo 93 respostas ao questionário eletrônico: 52,7% foram de instituições públicas de saúde, com média de 15 leitos de UTIN (15,2 ±15,9); 85% dos fisioterapeutas trabalhavam exclusivamente na UTIN, 34,4% das UTIN possuíam atendimento fisioterapêutico 24 horas por dia; 66,7% das unidades utilizam o Continuous Positive Airway Pressure (CPAP) como modo ventilatório e 72% a pronga nasal como interface de VNI; 90,3% dos fisioterapeutas responderam que suas UTIN não possuíam protocolo de desmame de VNI, com métodos de desmame relatados variados, sendo mais citado o desmame de pressão. Conclusões A maior parte das UTIN brasileiras não possui protocolo de desmame de VNI; o método mais utilizado entre as instituições que possuem ou não protocolo é o desmame de pressão. Apesar de a maioria dos voluntários trabalhar exclusivamente em UTIN, muitos hospitais não possuem a carga horária recomendada, o que pode ser um dos fatores negativos na organização dos protocolos e no andamento do desmame ventilatório.

6.
J. bras. pneumol ; 49(4): e20230131, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514417

RESUMO

ABSTRACT Objective: To identify factors associated with prolonged weaning and mortality in critically ill COVID-19 patients admitted to ICUs and under invasive mechanical ventilation. Methods: Between March of 2020 and July of 2021, we retrospectively recorded clinical and ventilatory characteristics of critically ill COVID-19 patients from the day of intubation to the outcome. We classified the patients regarding the weaning period in accordance with established criteria. A logistic regression analysis was performed to identify variables associated with prolonged weaning and mortality. Results: The study involved 303 patients, 100 of whom (33.0%) had a prolonged weaning period. Most of the patients were male (69.6%), 136 (44.8%) had more than 50% of pulmonary involvement on chest CT, and 93 (30.6%) had severe ARDS. Within the prolonged weaning group, 62% died within 60 days. Multivariate analysis revealed that lung involvement greater than 50% on CT and delay from intubation to the first separation attempt from mechanical ventilation were significantly associated with prolonged weaning, whereas age and prolonged weaning were significantly associated with mortality. Conclusions: Prolonged weaning can be used as a milestone in predicting mortality in critically ill COVID-19 patients. Lung involvement greater than 50% on CT and delay from intubation to the first separation attempt from mechanical ventilation were identified as significant predictors of prolonged weaning. These results might provide valuable information for healthcare professionals when making clinical decisions regarding the management of critically ill COVID-19 patients who are on mechanical ventilation.


RESUMO Objetivo: Identificar fatores associados ao desmame prolongado e à mortalidade em pacientes críticos com COVID-19 admitidos em UTI e sob ventilação mecânica invasiva. Métodos: Entre março de 2020 e julho de 2021, registramos retrospectivamente as características clínicas e ventilatórias de pacientes críticos com COVID-19 desde o dia da intubação até o desfecho. Os pacientes foram classificados quanto ao período de desmame de acordo com critérios estabelecidos. Foi realizada análise de regressão logística para identificar variáveis associadas ao desmame prolongado e à mortalidade. Resultados: O estudo incluiu 303 pacientes, 100 dos quais (33,0%) apresentaram período de desmame prolongado. A maioria dos pacientes era do sexo masculino (69,6%), 136 (44,8%) apresentaram mais de 50% de acometimento pulmonar na TC de tórax, e 93 (30,6%) apresentaram SDRA grave. No grupo desmame prolongado, 62% foram a óbito em 60 dias. A análise multivariada revelou que o acometimento pulmonar maior que 50% na TC e a demora na primeira tentativa de retirada da ventilação mecânica após a intubação apresentaram associação significativa com o desmame prolongado, enquanto a idade e o desmame prolongado apresentaram associação significativa com a mortalidade. Conclusões: O desmame prolongado pode ser utilizado como marco na predição de mortalidade em pacientes críticos com COVID-19. O acometimento pulmonar maior que 50% na TC e a demora na primeira tentativa de retirada da ventilação mecânica após a intubação foram identificados como preditores significativos de desmame prolongado. Esses resultados podem fornecer informações valiosas para os profissionais de saúde na tomada de decisões clínicas sobre o manejo de pacientes críticos com COVID-19 e em ventilação mecânica.

7.
Crit. Care Sci ; 35(2): 163-167, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448097

RESUMO

ABSTRACT Objective: To assess the outcome of extubation in COVID-19 patients and the use of noninvasive ventilation in the weaning process. Methods: This retrospective, observational, single-center study was conducted in COVID-19 patients aged 18 years or older who were admitted to an intensive care unit between April 2020 and December 2021, placed under mechanical ventilation for more than 48 hours and progressed to weaning. Early extubation was defined as extubation without a spontaneous breathing trial and immediate use of noninvasive ventilation after extubation. In patients who underwent a spontaneous breathing trial, noninvasive ventilation could be used as prophylactic ventilatory assistance when started immediately after extubation (prophylactic noninvasive ventilation) or as rescue therapy in cases of postextubation respiratory failure (therapeutic noninvasive ventilation). The primary outcome was extubation failure during the intensive care unit stay. Results: Three hundred eighty-four extubated patients were included. Extubation failure was observed in 107 (27.9%) patients. Forty-seven (12.2%) patients received prophylactic noninvasive ventilation. In 26 (6.8%) patients, early extubation was performed with immediate use of noninvasive ventilation. Noninvasive ventilation for the management of postextubation respiratory failure was administered to 64 (16.7%) patients. Conclusion: We found that COVID-19 patients had a high rate of extubation failure. Despite the high risk of extubation failure, we observed low use of prophylactic noninvasive ventilation in these patients.


RESUMO Objetivo: Avaliar o desfecho da extubação em pacientes com COVID-19 e o uso da ventilação não invasiva no processo de desmame. Métodos: Este estudo retrospectivo, observacional e unicêntrico foi realizado em pacientes com COVID-19 com 18 anos ou mais, internados em uma unidade de terapia intensiva entre abril de 2020 e dezembro de 2021, colocados sob ventilação mecânica por mais de 48 horas com progressão para o desmame. A extubação precoce foi definida como a extubação sem um teste de ventilação espontânea e com uso imediato de ventilação não invasiva após a extubação. Em pacientes submetidos a um teste de ventilação espontânea, a ventilação não invasiva poderia ser usada como assistência ventilatória profilática, quando iniciada imediatamente após a extubação (ventilação não invasiva profilática), ou como terapia de resgate em casos de insuficiência respiratória pós-extubação (ventilação não invasiva terapêutica). O desfecho primário foi falha de extubação durante a internação na unidade de terapia intensiva. Resultados: Foram incluídos 384 pacientes extubados. A falha de extubação foi observada em 107 (27,9%) pacientes. Quarenta e sete (12,2%) pacientes receberam ventilação não invasiva profilática. Em 26 (6,8%) pacientes, a extubação precoce foi realizada com o uso imediato de ventilação não invasiva. A ventilação não invasiva para o manejo da insuficiência respiratória pós-extubação foi administrada em 64 (16,7%) pacientes. Conclusão: Os pacientes com COVID-19 apresentaram alta taxa de falha de extubação. Apesar do alto risco de falha de extubação, observamos baixo uso de ventilação não invasiva profilática nesses pacientes.

8.
Braz. j. otorhinolaryngol. (Impr.) ; 88(6): 907-916, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420785

RESUMO

Abstract Introduction: Craniofacial growth is modified by chronic mouth breathing. Rapid maxillary expansion leads to separation of the mid-palatal suture, improving the occlusion and the upper airway size. Aim: Systematically evaluate scientific articles on the effects of rapid maxillary expansion on airway dimensions and classify the quality of the evidence of the information. Methods: Searches on PUBMED, LILACS, EMBASE, SCOPUS, WEB OF SCIENCE and COCHRANE, as well as in the grey literature were performed. The articles found were selected and evaluated both for the risk of bias (ROBINS-I) and for the quality of evidence (GRADE). Results: Of the 309 works found, 26 papers were selected for full reading, of which 22 were excluded. Data compilation and analysis were performed in four papers, two being controlled non-randomized clinical trials and two non-randomized and uncontrolled clinical trials. No randomized clinical trial was found. Conclusions: The meta-analysis found an increase in the internasal and inter-zygomatic distances and oropharyngeal volume after rapid maxillary expansion, which, together with clinical findings, makes the recommendation favorable to the intervention. The quality of the evidence for each outcome was considered very low.


Resumo Introdução: O crescimento craniofacial é modificado pela respiração oral crônica. A expansão rápida da maxila promove a separação da sutura palatino mediana, melhora a oclusão e a dimensão da via aérea superior. Objetivo: Avaliar de forma sistematizada os artigos científicos dos efeitos da expansão rápida da maxila sob as dimensões das vias aéreas e classificar a qualidade da evidência das informações. Método: Foi feita a busca nas plataformas Pubmed, Lilacs, Embase, Scopus, Web of Science e Cochrane, bem como a literatura cinzenta. Os artigos foram selecionados e avaliados quanto aos riscos de viés (ROBINS-I), e feita a avaliação da qualidade da evidência (GRADE). Resultados: De 309 estudos encontrados, 26 artigos foram selecionados para leitura completa, dos quais 22 excluídos, restaram 4 artigos para a análise e compilamento de dados, dois ensaios clínicos não randomizados controlados e dois ensaios clínicos não randomizados e não controlados. Nenhum ensaio clínico randomizado foi encontrado. Conclusões: As metanálises mostraram aumento de distância internasal, interzigomática e volume orofaríngeo após a expansão rápida da maxila, o que, juntamente aos achados clínicos, torna a recomendação favorável à intervenção. A qualidade da evidência de cada desfecho foi considerada muito baixa.

9.
Arq. ciências saúde UNIPAR ; 26(3): 315-327, set-dez. 2022.
Artigo em Português | LILACS | ID: biblio-1399066

RESUMO

O objetivo deste estudo foi comparar os desfechos clínicos dos pacientes em suporte ventilatório invasivo por período curto e prolongado e correlacionar funcionalidade e tempo de ventilação mecânica (VM). Estudo documental retrospectivo, realizado na UTI neurocirúrgica de um hospital escola. Dos prontuários clínicos foram coletados: idade, sexo, hipótese diagnóstica de internação, tempo de internação e de VM em dias, o desfecho sucesso ou falha da extubação e o nível de funcionalidade. Os prontuários foram divididos em grupo um (GI): pacientes em VM por até três dias e grupo dois (GII): pacientes em VM por mais de três dias. Foram analisados 210 prontuários, 73% dos pacientes permaneceram menos de três dias em VM. A idade média de GI foi 51,8±15,5 anos e GII 48,7±16,3 anos (p=0,20), prevalência do sexo masculino em GI (59%) e GII (68%). O acidente vascular cerebral foi o diagnóstico mais prevalente no GI (18%) e o tumor cerebral no GII (21%) e hipertensão arterial, a comorbidade mais prevalente em GI (28%) e GII (25%). O GII permaneceu maior tempo (p<0,0001) em VM e internação na UTI que o GI e percentual de sucesso no desmame/extubação menor (p=0,01) que o GI. Não houve correlação significativa entre funcionalidade e tempo de VM em GI e GII (p>0,05). Os pacientes em suporte ventilatório invasivo por período prolongado evoluíram com maior permanência em VM, maior tempo de internação na UTI e menor taxa de sucesso no desmame/extubação. O tempo de permanência em suporte ventilatório invasivo não interferiu na funcionalidade desses pacientes.


The aim of this study was to compare the clinical outcomes of patients on short- and long-term invasive ventilatory support and to correlate functionality and duration of mechanical ventilation (MV). Retrospective documental study, carried out in the neurosurgical ICU of a teaching hospital. The following were collected from the clinical records: age, gender, diagnostic hypothesis of hospitalization, length of hospital stay and MV in days, the outcome of success or failure of extubation and the level of functionality. The medical records were divided into group one (GI): patients on MV for up to three days and group two (GII): patients on MV for more than three days. A total of 210 medical records were analyzed, 73% of the patients remained on MV for less than three days. The mean age of GI was 51.8±15.5 years and GII 48.7±16.3 years (p=0.20), male prevalence in GI (59%) and GII (68%). Stroke was the most prevalent diagnosis in GI (18%) and brain tumor in GII (21%) and hypertension was the most prevalent comorbidity in GI (28%) and GII (25%). GII remained longer (p<0.0001) in MV and ICU admission than GI and the percentage of success in weaning/extubation was lower (p=0.01) than GI. There was no significant correlation between functionality and time on MV in GI and GII (p>0.05). Patients on invasive ventilatory support for a long period evolved with longer MV stays, longer ICU stays and lower weaning/extubation success rates. The length of stay on invasive ventilatory support did not interfere with the functionality of these patients.


El objetivo de este estudio fue comparar los resultados clínicos de los pacientes con soporte ventilatorio invasivo a corto y largo plazo y correlacionar la funcionalidad y el tiempo de ventilación mecánica (VM). Se trata de un estudio documental retrospectivo, realizado en la UCI neuroquirúrgica de un hospital universitario. Se recogieron los siguientes datos de las historias clínicas: edad, sexo, hipótesis diagnóstica, duración de la estancia y tiempo de VM en días, el resultado éxito o fracaso de la extubación y el nivel de funcionalidad. Las historias clínicas se dividieron en el grupo uno (GI): pacientes bajo VM hasta tres días y el grupo dos (GII): pacientes bajo VM durante más de tres días. Se analizaron 210 historias clínicas, el 73% de los pacientes permanecieron menos de tres días con VM. La edad media de GI fue de 51,8±15,5 años y la de GII de 48,7±16,3 años (p=0,20), con prevalencia masculina en GI (59%) y GII (68%). El ictus fue el diagnóstico más prevalente en GI (18%) y el tumor cerebral en GII (21%) y la hipertensión, la comorbilidad más prevalente en GI (28%) y GII (25%). El GII permaneció más tiempo (p<0,0001) en la VM y la estancia en la UCI que el GI y el porcentaje de éxito en el destete/extubación fue menor (p=0,01) que el GI. No hubo correlación significativa entre la funcionalidad y el tiempo de VM en GI y GII (p>0,05). Los pacientes con soporte ventilatorio invasivo a largo plazo evolucionaron con una mayor estancia en la VM, una mayor estancia en la UCI y una menor tasa de éxito de destete/extubación. La duración de la estancia con soporte ventilatorio invasivo no interfirió en la funcionalidad de estos pacientes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Respiração Artificial/instrumentação , Tempo de Permanência , Suporte Ventilatório Interativo/enfermagem , Suporte Ventilatório Interativo/instrumentação , Unidades de Terapia Intensiva , Tempo de Internação , Neoplasias Encefálicas/complicações , Desmame do Respirador/instrumentação , Comorbidade , Prontuários Médicos/estatística & dados numéricos , Modalidades de Fisioterapia/enfermagem , Acidente Vascular Cerebral/complicações , Extubação/instrumentação , Hospitalização , Hospitais de Ensino , Hipertensão/complicações
10.
Arch. argent. pediatr ; 120(2): 89-98, abril 2022. tab, ilus
Artigo em Inglês, Espanhol | BINACIS, LILACS | ID: biblio-1363662

RESUMO

Introducción: los beneficios de la ventilación asistida ajustada neuronalmente (NAVA) en los recién nacidos prematuros son inciertos. El objetivo de este estudio fue explorar si la NAVA no invasiva (NIV) era más beneficiosa para los recién nacidos prematuros que la presión positiva continua nasal (NCPAP). Diseño del estudio: metanálisis de tres ensayos clínicos: dos ensayos controlados aleatorizados y un estudio de grupos cruzados. Se comparó la NAVA-NIV con la NCPAP y se informó sobre el fracaso del tratamiento, la mortalidad y los eventos adversos como resultados principales. Resultados: tres estudios con 173 pacientes (89 recibieron NAVA-NIV) cumplieron los criterios de inclusión en este metanálisis. No se observaron diferencias en el fracaso del tratamiento entre la NAVA-NIV y la NCPAP (razón de riesgos [RR] = 1,09; intervalo de confianza [IC] del 95 % = 0,65-1,84; diferencia de riesgos = 0,02; IC95% = -0,10-0,14; I2 = 33 %; P = 0,23). De manera similar, no hubo diferencias en la mortalidad (RR = 1,52; IC95% = 0,51-4,52; no aplica heterogeneidad). En comparación con la NCPAP, la NAVA-NIV redujo significativamente el uso de cafeína (RR = 0,85; IC 95% = 0,74-0,98; I2 = 71 %; P = 0,03). Conclusiones: en comparación con la NCPAP, no hay evidencia suficiente para sacar una conclusión sobre los beneficios o daños de la NAVA-NIV en los recién nacidos prematuros. Los hallazgos de esta revisión deben confirmarse en ensayos clínicos con una metodología rigurosa y potencia adecuada


Introduction: The benefits of neurally adjusted ventilatory assist (NAVA) in preterm infants are unclear. This study aimed to explore if noninvasive NAVA is more beneficial for preterm infants than nasal continuous positive airway pressure (NCPAP). Study design: Meta-analysis was performed in three clinical trials comprising two randomized controlled trials and one crossover study. We compared NIV-NAVA and NCPAP and reported treatment failure, mortality, and adverse events as the primary outcomes. Results: Three studies including 173 patients (89 of whom underwent NIV-NAVA) were eligible for this meta-analysis. This review found no difference in treatment failure between NIV-NAVA and NCPAP (RR 1.09, 95% CI 0.65 to 1.84; RD 0.02, 95% CI -0.10-0.14; I2=33%, P=0.23). Similarly, there was no difference in mortality (RR 1.52, 95% CI 0.51-4.52, heterogeneity not applicable). Compared with NCPAP, NIV-NAVA significantly reduced the use of caffeine (RR 0.85, 95% CI 0.74-0.98, I2=71%, P=0.03). Conclusions: Compared with NCPAP, there is insufficient evidence to conclude on the benefits or harm of NIV-NAVA therapy for preterm infants. The findings of this review should be confirmed using methodologically rigorous and adequately powered clinical trials.


Assuntos
Humanos , Recém-Nascido , Suporte Ventilatório Interativo/efeitos adversos , Recém-Nascido Prematuro , Falha de Tratamento , Estudos Cross-Over , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos
11.
Rev. Soc. Bras. Clín. Méd ; 20(2): 95-102, 2022.
Artigo em Português | LILACS | ID: biblio-1428796

RESUMO

Introdução: A extubação no serviço de emergência não é realizada com frequência, mas pode ser segura em pacientes selecionados sendo que sua falha e subsequente reintubação é associada com aumento do tempo de ventilação mecânica e mortalidade. Objetivo: Estabelecer as variáveis preditivas de insucesso da extubação na sala de emergência para a identificação dos pacientes potencialmente elegíveis para o procedimento com maior assertividade. Métodos: Estudo retrospectivo através da análise de prontuário de pacientes que foram extubados no serviço de emergência do Hospital de Base de São José de Rio Preto/SP no período de julho de 2018 a julho de 2021. Dados clínicos e demográficos foram coletados, como idade, sexo, causa da intubação e doenças associadas. Os demais dados analisados após a extubação do paciente foram necessidade de reintubação, tempo de internação hospitalar, necessidade de terapia intensiva, alta hospitalar e óbito. Resultados: Os preditores de reintubação orotraqueal avaliados foram idade, sexo masculino, duração da intubação, doenças cardíacas, pulmonares, gastrointestinais e infecciosas, traumatismo cranioencefálico, ventilação não invasiva pós-extubação e estridor. Os preditores com maior Odds Ratio foram estridor, doenças infecciosas e ventilação não invasiva pós-extubação, com aumento da chance de reintubação comparado aos outros pacientes. Conclusão: A análise conjunta das variáveis clínicas mais a identificação dos fatores de insucesso apresentados estimulam a equipe assistencial a buscar a extubação de pacientes selecionáveis dentro da sala de emergência com maior assertividade


Introduction: Extubation in the emergency department is not performed frequently, but it can be safe in selected patients, and its failure and subsequent reintubation is associated with increased duration of mechanical ventilation and mortality. Objective: To establish predictive variables of extubation failure in the emergency room to identify patients potentially eligible for the procedure with greater assertiveness. Methods: Retrospective study by analyzing the medical records of patients who were extubated in the emergency department of the Hospital de Base de São José de Rio Preto/SP from July 2018 to July 2021. Clinical and demographic data were collected, such as age, sex, cause of intubation and associated diseases. The other data analyzed after extubation of the patient were need for reintubation, length of hospital stay, need for intensive care, hospital discharge and death. Results: The predictors of orotracheal reintubation evaluated were age, male gender, duration of intubation, cardiac, pulmonary, gastrointestinal and infectious diseases, traumatic brain injury, non-invasive post-extubation ventilation and stridor. The predictors with the highest Odds Ratio were stridor, infectious diseases and post-extubation noninvasive ventilation, with an increased chance of reintubation compared to other patients. Conclusion: The joint analysis of clinical variables plus the identification of failure factors presented encourage the care team to seek the extubation of selectable patients within the emergency room with greater assertiveness.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Serviço Hospitalar de Emergência/estatística & dados numéricos , Extubação/estatística & dados numéricos , Respiração Artificial/estatística & dados numéricos , Modelos Logísticos , Demografia , Análise Multivariada , Intubação Intratraqueal/estatística & dados numéricos
12.
CoDAS ; 34(2): e20200251, 2022. tab
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1345837

RESUMO

RESUMO Objetivo Verificar a relação entre o processamento sensorial e as alterações das funções do Sistema Estomatognático de crianças respiradoras orais, caracterizando o processamento sensorial destas e comparando-o com o de respiradoras nasais. Método Foram selecionadas 50 crianças (5 a 12 anos) que apresentaram diagnóstico de respiração oral e 50 sem sinais e sintomas de respiração oral ou rinite alérgica para fazer parte do grupo controle, pareadas por idade e sexo. As crianças respiradoras orais e nasais passaram por avaliação do processamento sensorial, através da Sensory Processing Measure - Home form, e as respiradoras orais por avaliação da motricidade orofacial através da Avaliação Miofuncional Orofacial com Escore. Os resultados foram apresentados em forma de tabela e com suas respectivas frequências absoluta e relativa. Resultados A maioria das crianças avaliadas foi do sexo masculino, estando com idade média de 8 anos. A maioria dos respiradores orais apresentou alteração no processamento de todos os sentidos, com relação estatisticamente significativa quando comparados com os respiradores nasais. Houve relação, nos respiradores orais, entre o processamento sensorial proprioceptivo e o movimento das bochechas, processamento sensorial visual e movimentação da cabeça durante a deglutição e entre o tipo de mastigação e o processamento sensorial tátil. Conclusão Após análise dos dados foi possível perceber que o processamento sensorial de todos os sistemas se apresenta com alteração nos respiradores orais e que esse mau processamento se relaciona a mobilidade orofacial, bem como com funções do Sistema Estomatognático, além do tipo de mastigação dessa população.


ABSTRACT Purpose To verify the relationship between sensory processing and changes in the functions of the stomatognathic system in mouth breathing children, characterizing their sensory processing and comparing it with that of nasal breathing children. Methods 50 children (5 to 12 years) who were diagnosed with mouth breathing and 50 without signs and symptoms of mouth breathing or allergic rhinitis were selected to be part of the control group, matched for age and sex. Oral and nasal breathing children underwent sensory processing evaluation, through the Sensory Processing Measure - home form, and mouth breathers, through the evaluation of orofacial motricity through the Orofacial Myofunctional Evaluation with score. The results were presented in table form and with their respective absolute and relative frequencies. Results Most of the children evaluated were male, with an average age of eight years. Most mouth breathers presented alteration in the processing of all senses, with a statistically significant relationship when compared to nasal breathers. There was a relationship, in mouth breathers, between proprioceptive sensory processing and the movement of the cheeks, visual sensory processing and head movement during swallowing, and between the type of chewing and tactile sensory processing. Conclusion After analyzing the data, it was possible to see that the sensory processing of all systems presents with changes in mouth breathers and that this poor processing is related to orofacial mobility, as well as functions of the stomatognathic system, in addition to the type of chewing of this population.

13.
Rev. peru. med. exp. salud publica ; 38(3): 391-398, jul.-sep. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1357384

RESUMO

RESUMEN Objetivo: Desarrollar una metodología para evaluar el nivel de protección respiratoria de respiradores, mascarillas quirúrgicas y mascarillas comunitarias que usa la población peruana, usando partículas de un tamaño similar a las que contienen al virus activo del SARS-CoV-2. Materiales y métodos: Se ha determinado una relación lineal directa entre el logaritmo de la concentración de partículas suspendidas en aire y el tiempo transcurrido; por lo cual es posible comparar la cantidad de partículas internas y externas a la mascarilla o respirador en un mismo periodo y conocer el porcentaje de protección respiratoria de cada muestra evaluada. Resultados: Se ha logrado implementar una metodología para evaluar el nivel de protección respiratoria ante aerosoles menores a 5,0 µm. Asimismo, el empleo de accesorios como ligas o ajustadores detrás de cabeza y nuca, y el uso de clips nasales robustos, incrementan significativamente el nivel de protección respiratoria ante partículas con alta probabilidad de contener al SARS-CoV-2. Conclusiones: Se observa una concordancia entre los valores de protección respiratoria obtenidos y los esperados, considerando el nivel de filtración del material empleado de cada mascarilla quirúrgica o respirador, y su nivel de ajuste. Se observó un incremento significativo en los niveles de protección respiratoria.


ABSTRACT Objective: To develop a methodology for evaluating the level of respiratory protection provided by respirators, surgical masks and community face masks used by the Peruvian population; protection was evaluated against particles of a size similar to those containing active SARS-CoV-2 virus. Materials and methods: A direct linear relationship has been determined between the logarithm of the concentration of airborne particles and the elapsed time; thus, it is possible to compare the quantity of particles inside and outside of the mask or respirator in the same time period, as well as to obtain the percentage of respiratory protection for each evaluated sample. Results: A methodology was established to evaluate the level of respiratory protection against aerosols smaller than 5.0 μm. Also, the use of accessories such as rubber bands or adjusters behind the head and neck, and the use of robust nasal clips, significantly increased the level of respiratory protection against particles with a high probability of containing SARS-CoV-2. Conclusions: We found concordance between the obtained respiratory protection values and those expected, considering the filtration level of the material used for each surgical mask or respirator, as well as the tightness. A significant increase in the levels of respiratory protection was observed.


Assuntos
Dispositivos de Proteção Respiratória , Transmissão de Doença Infecciosa , SARS-CoV-2 , COVID-19 , Máscaras , Ventiladores Mecânicos , Aerossóis , Níveis Máximos Permitidos , Pandemias , Filtração
15.
Rev. bras. ter. intensiva ; 33(2): 304-311, abr.-jun. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1280170

RESUMO

RESUMO Para a extubação orotraqueal em pacientes pediátricos, é fortemente recomendada a avaliação de sua prontidão. No entanto, a utilização de um dispositivo ou prática que fosse superior ao julgamento clínico ainda não foi determinada com exatidão. Assim, é importante realizar uma revisão sobre as técnicas preditoras de escolha na prática clínica para prever a falha de extubação orotraqueal em pacientes pediátricos. A partir de uma busca nas bases de dados PubMed®, Biblioteca Virtual em Saúde, Cochrane Library e Scopus, realizamos um levantamento das variáveis preditoras de falha de extubação orotraqueal mais comumente utilizadas na prática clínica em pacientes pediátricos. Dos oito preditores descritos, observamos três mais usados: teste de respiração espontânea, índice de respiração rápida e superficial e pressão inspiratória máxima. Embora a disparidade dos dados apresentados nos estudos tenha inviabilizado um tratamento estatístico, foi possível, a partir desse meio, descrever e analisar o desempenho desses testes.


ABSTRACT For extubation in pediatric patients, the evaluation of readiness is strongly recommended. However, a device or practice that is superior to clinical judgment has not yet been accurately determined. Thus, it is important to conduct a review on the techniques of choice in clinical practice to predict extubation failure in pediatric patients. Based on a search in the PubMed®, Biblioteca Virtual em Saúde, Cochrane Library and Scopus databases, we conducted a survey of the predictive variables of extubation failure most commonly used in clinical practice in pediatric patients. Of the eight predictors described, the three most commonly used were the spontaneous breathing test, the rapid shallow breathing index and maximum inspiratory pressure. Although the disparity of the data presented in the studies prevented statistical treatment, it was still possible to describe and analyze the performance of these tests.


Assuntos
Humanos , Criança , Desmame do Respirador , Extubação , Unidades de Terapia Intensiva Pediátrica
16.
Fisioter. Pesqui. (Online) ; 27(3): 306-311, jul.-set. 2020. tab
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1154244

RESUMO

RESUMO A realização da traqueostomia precoce pode reduzir o tempo de ventilação do paciente, facilitando o desmame da prótese ventilatória. Além disso, reduz os custos de internação. Este estudo tem como objetivo analisar o tempo de retirada do respirador no paciente traquestomizado precocemente após sete dias de ventilação. Trata-se de pesquisa documental, retrospectiva, de carácter descritivo, sendo a coleta de dados realizada nos documentos de indicadores hospitalares de unidade de terapia intensiva de um hospital da Zona da Mata mineira. Foram coletados dados de 50 pacientes que obtiveram sucesso e preencheram os critérios de desmame da ventilação mecânica, entre homens e mulheres, com média de idade de 56,6 anos. Para análise estatística, os pacientes foram divididos em dois grupos: grupo precoce, de pacientes que realizaram traqueostomia com menos de sete dias de intubação orotraqueal; e grupo tardio, de pacientes que permaneceram por mais de sete dias com tubo orotraqueal até a realização da traqueostomia. Obtivemos um resultado significativo (p=0,04) quanto aos dias em ventilação mecânica após a realização de traqueostomia, demonstrando que nos pacientes com traqueostomia precoce houve menos dias em ventilação mecânica invasiva do que nos pacientes com traqueostomia tardia. Foi constatado um resultado significativamente menor do tempo de ventilação dos pacientes traquestomizados precocemente quando comparados com a traqueostomia tardia. Ensaios clínicos randomizados de alta qualidade são necessários para avaliar melhor as possíveis diferenças da retirada da ventilação mecânica entre pacientes traqueostomizados.


RESUMEN La realización de traqueotomía temprana puede reducir el tiempo de ventilación del paciente, facilitando la desconexión del soporte ventilatorio. Además, reduce los costes de hospitalización. Este estudio tiene como objetivo analizar el tiempo de retiro del ventilador en los pacientes traqueostomizados tempranamente después de siete días de soporte ventilatorio. Se trata de una investigación documental, retrospectiva, descriptiva, que recopiló los datos de documentos hospitalarios de la unidad de cuidados intensivos de un hospital en Zona da Mata en Minas Gerais (Brasil). Se recogieron datos de 50 pacientes, entre hombres y mujeres con promedio de edad de 56,6 años, que tuvieron éxito y cumplieron los criterios para la desconexión del ventilador mecánico. Para el análisis estadístico, se dividieron a los pacientes en dos grupos: Grupo temprano, pacientes que se sometieron a traqueotomía con menos de siete días de intubación orotraqueal; y Grupo tardío, pacientes que permanecieron más de siete días con un tubo orotraqueal hasta la realización de la traqueotomía. Hubo un resultado significativo (p=0,04) con respecto a los días de ventilación mecánica tras la realización de traqueotomía, lo que demuestra que los pacientes con traqueotomía temprana pasaron menos días con ventilador mecánico invasivo que los pacientes con traqueotomía tardía. Se encontró un resultado significativamente menor del tiempo de ventilación de los pacientes con traqueostomía temprana en comparación a los pacientes con traqueotomía tardía. Se necesitan ensayos clínicos aleatorios de alta calidad para evaluar mejor las posibles diferencias en el retiro del ventilador mecánico entre los pacientes traqueostomizados.


ABSTRACT Early tracheostomy can reduce patient ventilation time, facilitating the weaning process and reducing hospitalization costs. This study analyzes the removal time of ventilators in patients submitted to early tracheostomy, after seven days of ventilation. This is a documentary, retrospective, and descriptive research. Data were collected from documents with hospital indicators of an intensive care unit in the Zona da Mata region in Minas Gerais. Data consisted of 50 patients who were successful in the weaning of mechanical ventilation and met the study criteria. They were both men and women, with a mean age of 56.6 years. For statistical analysis, the patients were divided into two groups: an early group - patients who underwent tracheostomy with less than seven days of orotracheal intubation; and a late group - patients who remained for more than seven days with orotracheal tube before tracheostomy. We obtained a significant result (p=0.04) regarding the days on mechanical ventilation after tracheostomy, demonstrating that patients with early tracheostomy remained fewer days on invasive mechanical ventilation than patients with late tracheostomy. A significantly lower result of ventilation time was observed in patients submitted to early compared with late tracheostomy. High-quality randomized clinical trials are needed to better evaluate the possible differences in mechanical ventilation withdrawal among tracheostomized patients.

17.
Rev. enferm. UFSM ; 10: 67, 2020.
Artigo em Inglês, Português | BDENF, LILACS | ID: biblio-1127945

RESUMO

Objetivo: verificar a associação do teste de respiração espontânea com o diagnóstico de enfermagem Resposta disfuncional ao desmame ventilatório (00034) e identificar as medidas de acurácia do teste de respiração espontânea para o diagnóstico de enfermagem. Método: estudo transversal com 42 pacientes em cuidado crítico. O Teste Exato de Fischer verificou a associação, e as medidas de acurácia foram calculadas com o Medcalc Software Online®. Resultados: a associação entre o teste e o diagnóstico foi significativa (p=0,0079). As medidas de acurácia destacadas foram especificidade 77,42% (58,90 ­ 90,41), razão de verossimilhança positiva 3,22 (1,53 ­ 6,79) e odds ratio diagnóstica 9,14 (1,90 ­ 44,01). Conclusão: o estudo verificou a existência de associação entre o desfecho do teste de respiração espontânea e a Resposta disfuncional ao desmame ventilatório (00034), com significância estatística. Também indicou adequação de três medidas de acurácia para o diagnóstico de enfermagem.


Objective: to verify the association of the spontaneous breathing test with the nursing diagnosis of Dysfunctional Ventilatory Weaning Response (00034) and to identify the accuracy measures of the spontaneous breathing test for the nursing diagnosis. Method: a cross-sectional study conducted with 42 patients in critical care. Fischer's exact test verified the association, and the accuracy measures were calculated with Medcalc Software Online®. Results: the association between the test and the diagnosis was significant (p=0.0079). The highlighted accuracy measures were 77.42% specificity (58.90 ­ 90.41), positive likelihood ratio of 3.22 (1.53 ­ 6.79), and diagnostic odds ratio of 9.14 (1.90 ­ 44.01). Conclusion: the study verified the existence of an association between the outcome of the spontaneous breathing test and the Dysfunctional Ventilatory Weaning Response (00034), with statistical significance. It also indicated the adequacy of three accuracy measures for the nursing diagnosis.


Objetivo: verificar la asociación de la prueba de respiración espontánea con el diagnóstico de enfermería de Respuesta disfuncional a la desconexión del ventilador (00034) e identificar las medidas de exactitud de la prueba de respiración espontánea para el diagnóstico de enfermería. Método: estudio transversal realizado con 42 pacientes en cuidados críticos. La prueba exacta de Fischer verificó la asociación, y las medidas de exactitud se calcularon con Medcalc Software Online®. Resultados: la asociación entre la prueba y el diagnóstico fue significativa (p=0,0079). Las medidas de exactitud destacadas fueron las siguientes: especificidad, 77,42% (58,90 ­ 90,41), razón de verosimilitud positiva, 3,22 (1,53 ­ 6,79) y Odds Ratio diagnóstica, 9,14 (1,90 ­ 44,01). Conclusión: el estudio verificó la existencia de una asociación entre el resultado de la prueba de respiración espontánea y la Respuesta disfuncional a la desconexión del ventilador (00034), con significancia estadística. También indicó la adecuación de tres medidas de exactitud para el diagnóstico de enfermería.


Assuntos
Humanos , Respiração Artificial , Testes de Função Respiratória , Diagnóstico de Enfermagem , Desmame do Respirador , Tomada de Decisões
18.
Int. j. odontostomatol. (Print) ; 14(3): 310-315, 2020.
Artigo em Espanhol | LILACS | ID: biblio-1114897

RESUMO

El SARS-CoV-2 es un tipo de coronavirus con un alto grado de contagio entre pacientes y personal de salud, por lo que ha provocado la emergencia sanitaria más grande de los últimos años. Los equipos de protección personal (EPP) tienen como indicación un único uso, sin embargo, la escasez de estos ha llevado a buscar métodos para descontaminarlos y reutilizarlos, asegurando su disponibilidad. La evidencia presenta múltiples procedimientos para descontaminar mascarillas con filtro respirador tipo N95 (MFR N95), pero el método ideal debe inactivar al patógeno, asegurar la integridad del filtro respirador, el ajuste de la mascarilla y la salud del personal que la utilizará. La descontaminación con peróxido de hidrógeno vaporizado, irradiación germicida ultravioleta e incubación con calor húmedo se presentan como los métodos más eficaces contra distintos patógenos. Ante la creciente demanda de EPP y MFR N95, se sugiere realizar más estudios clínicos, que evalúen la eficacia de los métodos de descontaminación específicamente contra SARS-CoV-2 y se generen protocolos que permitan reutilizar con total seguridad este vital elemento para el personal de salud.


SARS-CoV-2 is a type of coronavirus with a high risk of contagion among patients and health care workers (HCW), being the cause of the largest health emergency in recent years. Personal Protective Equipment (PPE) are indicated for a single use. However, shortage has led to research new methods to decontaminate and reuse them, ensuring its availability. Evidence presents multiple procedures to decontaminate Filtering Facepiece Respirators type N95 (FFR), despite this, the ideal treatment should inactivate the pathogen, to ensure filter integrity, mask adjustments and the safety of who use this elements. Decontamination methods as vaporized hydrogen peroxide, ultraviolet germicidal irradiation and moist heat are the most effective procedures against different pathogens. Facing the rising demand of PPE and FFR, it's suggested to conduct researches to evaluate decontamination methods efficacy, and specifically against SARS-CoV-2, to generate protocols in ways to let to HCW reuse FFR N95 totally safe.


Assuntos
Humanos , Pneumonia Viral/prevenção & controle , Dispositivos de Proteção Respiratória , Descontaminação/métodos , Infecções por Coronavirus/prevenção & controle , Pandemias/prevenção & controle , Desinfecção , Contaminação de Equipamentos/prevenção & controle , Reutilização de Equipamento , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Filtração , Betacoronavirus , Máscaras
19.
J. bras. pneumol ; 46(4): e20190005, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1090817

RESUMO

ABSTRACT Objective: The aim of this study was to describe practices for weaning from mechanical ventilation (MV), in terms of the use of protocols, methods, and criteria, in pediatric ICUs (PICUs), neonatal ICUs (NICUs), and mixed neonatal/pediatric ICUs (NPICUs) in Brazil. Methods: This was a cross-sectional survey carried out by sending an electronic questionnaire to a total of 298 NICUs, PICUs, and NPICUs throughout Brazil. Results: Completed questionnaires were assessed for 146 hospitals, NICUs accounting for 49.3% of the questionnaires received, whereas PICUs and NPICUs accounted for 35.6% and 15.1%, respectively. Weaning protocols were applied in 57.5% of the units. In the NICUs and NPICUs that used weaning protocols, the method of MV weaning most commonly employed (in 60.5% and 50.0%, respectively) was standardized gradual withdrawal from ventilatory support, whereas that employed in most (53.0%) of the PICUs was spontaneous breathing trial (SBT). During the SBTs, the most common ventilation mode, in all ICUs, was pressure-support ventilation (10.03 ± 3.15 cmH2O) with positive end-expiratory pressure. The mean SBT duration was 35.76 ± 29.03 min in the NICUs, compared with 76.42 ± 41.09 min in the PICUs. The SBT parameters, weaning ventilation modes, and time frame considered for extubation failure were not found to be dependent on the age profile of the ICU population. The findings of the clinical evaluation and arterial blood gas analysis are frequently used as criteria to assess readiness for extubation, regardless of the age group served by the ICU. Conclusions: In Brazil, the clinical practices for weaning from MV and extubation appear to vary depending on the age group served by the ICU. It seems that weaning protocols and SBTs are used mainly in PICUs, whereas gradual withdrawal from ventilatory support is more widely used in NICUs and NPICUs.


RESUMO Objetivo: Descrever as práticas de desmame da ventilação mecânica (VM), quanto ao uso de protocolos, métodos e critérios, em UTIs pediátricas (UTIPs), neonatais (UTINs) e mistas - neonatais e pediátricas (UTINPs) - no Brasil. Métodos: Estudo transversal, tipo inquérito, realizado por meio do envio de questionário eletrônico a 298 UTINs, UTIPs e UTINPs de todo o país. Resultados: Foram avaliados 146 questionários respondidos (49,3% recebidos de UTINs, 35,6%, de UTIPs e 15,1%, de UTINPs). Das unidades pesquisadas, 57,5% aplicavam protocolos de desmame. Nas UTINs e UTINPs que utilizavam esses protocolos, o método de desmame da VM mais empregado (em 60,5% e 50,0%, respectivamente) foi a redução gradual padronizada do suporte ventilatório, enquanto o empregado na maioria (53,0%) das UTIPs foi o teste de respiração espontânea (TRE). Durante o TRE, o modo ventilatório predominante em todas as UTIs foi a ventilação com pressão de suporte (10,03 ± 3,15 cmH2O) com pressão expiratória final positiva. A duração média do TRE foi de 35,76 ± 29,03 min nas UTINs, contra 76,42 ± 41,09 min nas UTIPs. Os parâmetros do TRE, modos ventilatórios de desmame e tempo considerado para falha de extubação não se mostraram dependentes do perfil etário da população das UTIs. Os resultados da avaliação clínica e da gasometria arterial são frequentemente utilizados como critérios para avaliar a prontidão para extubação, independentemente da faixa etária atendida pela UTI. Conclusões: No Brasil, a prática clínica na condução do desmame da VM e extubação varia de acordo com a faixa etária atendida pela UTI. Protocolos de desmame e o TRE são utilizados principalmente nas UTIPs, enquanto a redução gradual do suporte ventilatório é mais utilizada nas UTINs e UTINPs.


Assuntos
Humanos , Recém-Nascido , Criança , Respiração Artificial/métodos , Unidades de Terapia Intensiva Pediátrica/normas , Desmame do Respirador/métodos , Respiração Artificial/estatística & dados numéricos , Insuficiência Respiratória/terapia , Brasil , Estudos Transversais , Inquéritos e Questionários , Pesquisas sobre Atenção à Saúde
20.
Rev. latinoam. enferm. (Online) ; 28: e3334, 2020. tab, graf
Artigo em Inglês | BDENF, LILACS | ID: biblio-1126991

RESUMO

Objective: to clinically validate the nursing diagnosis of Dysfunctional Ventilatory Weaning Response in adult patients admitted to Intensive Care Units. Method: a concurrent cohort performed with 93 patients admitted to Intensive Care Units. The incidence and incidence density of the diagnosis were estimated, its related factors were identified based on bivariate analysis and clinical indicators for determining its occurrence, according to the global and temporal presentation. Results: the overall incidence of the diagnosis was 44.09% and the incidence density was 14.49 occurrences for every 100 extubations/day. The factors related to the diagnosis were the following: age, clinical severity, fluid balance, oliguria, hemodialysis, edema in upper/lower limbs, anasarca, number of antibiotics, hypothermia, hyperthermia, amount of secretion, muscle retraction, anxiety score, heart rate, use of vasopressors and non-invasive ventilation after extubation. The clinical indicators most frequently identified for determining the diagnosis were the following: tachypnea, drop of saturation and tachycardia. Temporal progression in the severity of these manifestations was found. Conclusion: the Dysfunctional Ventilatory Weaning Response is a common finding in critically ill patients. Some components of the diagnosis of the NANDA-International (2018) version could be clinically validated. It is noteworthy that there are variables not yet described in the taxonomy, demonstrating the need to review this nursing diagnosis.


Objetivo: validar clinicamente o diagnóstico de enfermagem Resposta Disfuncional ao Desmame Ventilatório em pacientes adultos internados em Unidades de Terapia Intensiva. Método: coorte concorrente realizada com 93 pacientes internados em Unidades de Terapia Intensiva. Foram estimadas a incidência e a densidade de incidência do diagnóstico, identificados seus fatores relacionados a partir de análise bivariada e indicadores clínicos de determinação da sua ocorrência, segundo apresentação global e temporal. Resultados: a incidência global do diagnóstico foi de 44,09% e a densidade de incidência de 14,49 ocorrências a cada 100 extubações/dia. Os fatores relacionados ao diagnóstico foram: idade, gravidade clínica, balanço hídrico, oligúria, hemodiálise, edema em membros superiores/inferiores, anasarca, número de antibióticos, hipotermia, hipertermia, quantidade de secreção, retração muscular, escore de ansiedade, frequência cardíaca, uso de vasopressores e ventilação não invasiva após a extubação. Os indicadores clínicos identificados mais frequentemente para a determinação do diagnóstico foram: taquipneia, queda de saturação e taquicardia. Verificou-se progressão temporal da gravidade dessas manifestações. Conclusão: a Resposta Disfuncional ao Desmame Ventilatório é um achado comum em pacientes críticos. Alguns componentes do diagnóstico da versão NANDA-International (2018) puderam ser validados clinicamente. Destaca-se que existem variáveis ainda não descritas na taxonomia, demonstrando a necessidade de revisão desse diagnóstico de enfermagem.


Objetivo: validar clínicamente el diagnóstico de enfermería Respuesta Ventilatoria Disfuncional al Destete en pacientes adultos internados en Unidades de Cuidados Intensivos. Método: cohorte concurrente realizada con 93 pacientes internados en Unidades de Cuidados Intensivos. Se estimó la incidencia y densidad de incidencia del diagnóstico y se identificaron los factores vinculados a partir de análisis bivariados e indicadores clínicos para determinar su ocurrencia, de acuerdo con la presentación global y temporal. Resultados: la incidencia global del diagnóstico fue de 44,09% y la densidad de incidencia de 14,49 casos por cada 100 extubaciones/día. Los factores relacionados con el diagnóstico fueron: edad, gravedad clínica, balance hídrico, oliguria, hemodiálisis, edema en miembros superiores/inferiores, anasarca, número de antibióticos, hipotermia, hipertermia, cantidad de secreción, retracción muscular, grado de ansiedad, frecuencia cardíaca, uso de vasopresores y ventilación no invasiva después de la extubación. Los indicadores clínicos identificados con mayor frecuencia para determinar el diagnóstico fueron: taquipnea, disminución de la saturación de oxígeno y taquicardia. Se verificó una progresión temporal en la gravedad de estas afecciones. Conclusión: La Respuesta Ventilatoria Disfuncional al Destete es un hallazgo común en pacientes críticos. Algunos componentes del diagnóstico de la versión NANDA-International (2018) podrían validarse clínicamente. Es de destacar que hay variables aún no descriptas en la taxonomía, lo que demuestra la necesidad de revisar este diagnóstico de enfermería.


Assuntos
Humanos , Masculino , Feminino , Adulto , Vasoconstritores , Diagnóstico de Enfermagem , Desmame do Respirador , Enfermagem , Falha de Tratamento , Estudo de Validação , Extubação , Ventilação não Invasiva , Unidades de Terapia Intensiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA