Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Radiation Oncology ; (6): 508-512, 2016.
Artigo em Chinês | WPRIM | ID: wpr-493041

RESUMO

Objective To study the effect of amplitude of respiratory movements on dose distribution of static intensity-modulated radiotherapy (IMRT),and to provide a basis for dose correction against respiratory movements.Methods A two-dimensional matrix driven by the QUASAR program-controlled respiratory movement instrument was used to simulate human respiratory movements in the head/foot direction.The dose distribution was evaluated on the isocenter plane with different amplitudes of respiratory movements.The Verisoft software and absolute dose analysis were used to analyze dose distribution,percentage errors of absolute dose,and passing rates of radiation field for both collected data and planned dose distribution.Results In spite of little effect on dose distribution in target volume,respiratory movements increased the dose outside the marginal target volume along the movement direction.When the respiratory amplitude was lower than 6 mm,the passing rate of γdistribution met the requirement of clinical dose verification;when the respiratory amplitude was larger than 8 mm,the passing rate of γ distribution was reduced with the increasing respiratory amplitude and fell below the clinical standard.Conclusions Respiratory movements have a blurring effect on static IMRT.It is possible to introduce some compensation methods to static IMRT in the treatment of tumor with periodic respiratory movements.The normal tissue at the edge of target volume along the respiratory movement direction is exposed to a higher radiation dose than expected.Therefore,the radiation dose for the normal tissue around target volume should be made as low as possible in the radiotherapy plan.For the patients with relatively large respiratory amplitude,action should be taken to lower respiratory amplitude and elevate the radiation dose in target volume.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 220-224, 2016.
Artigo em Chinês | WPRIM | ID: wpr-488592

RESUMO

Objective To study the effect of the respiratory amplitude on the dose distribution of volumetric modulated arc therapy (VMAT).Methods Respiratory motion simulation phantom (QUASAR) was used to simulate the respiratory movement from head to toe,and a two-dimensional ionization chamber matrix was used to collect the dose distribution in isocenter with different respiratory amplitude.Verisoft software and absolute dose analysis were used to analyze dose distribution,percentage errors of absolute dose in isocenter,passing rates of radiation field for the data collected,and results were compared to planned dosage.Results The effect on isocenter target dose of respiratory motion was below dose tolerance 5% (t =-22.614--10.756,P < 0.05).The respiratory movement made the dose on the edge of the target area higher,with fewer hot spots and more cold spots in the target area.As the respiratory amplitude increased,the effect of respiratory movement on the overall dose distribution in the target area was greater.The difference of the whole beam γ passing rate between 6,8,10 mm and stationary state was significant (t =3.095,8.685,14.096,P < 0.05).The difference of target γ passing rate between 8,10 mm and stationary state was significant (t =6.081,9.841,P <0.05).Conclusions The respiratory movement could cause the dose transmission errors of VMAT,the error increased with increased range of motion.The actual radiation dose for normal tissues along the direction of respiratory movement on the target edge was higher than what was planned.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA