Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Odovtos (En línea) ; 23(3)dic. 2021.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386559

RESUMO

ABSTRACT: There is insufficient information about the chairside polishing methods of polyether ether ketone material. Therefore, it is aimed in this study to investigate the effects of different polishing processes on polyether ether ketone surface roughness and hardness. A total of 66 disc-shaped specimens made of polyether ether ketone were used in this study. The specimens were polished conventionally and randomly divided into three groups (n=22). One group was designated as the control group, and no further treatment was applied. In the other two groups, the specimens' surfaces were abraded with diamond burs and polished using two different polishing kits. Their surface roughness and Vickers hardness were measured, and environmental scanning electron microscopy and atomic force microscopy examinations were performed. The data were statistically analysed using analysis of variance and Tukey's honest significant difference test (α=0.05). There were no statistically significant differences between the control and polishing kit groups in terms of either surface roughness or Vickers hardness (p>0.05). The polishing kits can be used reliably and effectively for polishing polyether ether ketone materials.


RESUMEN: No existe información suficiente sobre los métodos de pulido del material poliéter éter cetona. Por tanto, este estudio tiene como objetivo evaluar el efecto de diferentes procedimientos de pulido sobre la rugosidad y dureza de superficie de un material a base de poliéter éter acetona. Un total de 66 muestras en forma de disco fueron realizadas. Los especímenes fueron divididos en tres grupos (n=22). Un grupo fue designado como grupo de control, siendo que no se aplicó ningún tratamiento. En los otros dos grupos, las superficies de las muestras se lijaron con fresas de diamante y se pulieron con dos kits de pulido diferentes. Se investigó la rugosidad de superficie y la dureza Vickers en los diferentes grupos. También fueron evaluadas muestras representativas en microscopía electrónica de barrido y microscopía de fuerza atómica. Los datos se analizaron estadísticamente mediante el análisis de varianza (ANOVA) y el método de Tukey (α=0.05). No hubo diferencias estadísticamente significativas entre los grupos en términos de rugosidad de superficie o Dureza Vickers (p>0,05). Los kits de pulido se pueden utilizar de forma eficaz para el pulido de materiales a base de poliéter éter acetona.


Assuntos
Polietilenos , Polimento Dentário , Dentifrícios/análise
2.
Odovtos (En línea) ; 22(3)dic. 2020.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386494

RESUMO

Abstract Avoiding biofilm formation on dentures is associated with maintaining the surface properties of acrylic-based dentures. The aim of the study is to investigate the effects of two different cleaning agents (Corega and Klorhex 0.2% chlorhexidine gluconate) on surface roughness of the denture regarding efficacy of curing procedures. A total of sixty disc-shaped specimens were prepared with two different methods as long and short curing processes. The specimens were divided into subgroups according to the immersion solutions (distilled water, Corega tablet group and Klorhex 0.2% chlorhexidine gluconate group) (n=10). The samples were kept in a solution for 8 hours per day during a month. The average Ra1 (before exposure to the cleanser agent) and Ra2 (after exposure to the cleanser agent) of each sample was measured. A two- way ANOVA and post hoc Tukey test was used for statistical analysis. The solutions significantly increased the Ra values in both acrylic groups (p0.05). The long-term curing time is highly effective in decreasing the surface roughness of the acrylic base material.


Resumen Evitar la formación de biopelículas en las prótesis dentales se asocia con el mantenimiento de las propiedades de la superficie de las prótesis de base acrílica. El objetivo del estudio es investigar los efectos de dos agentes de limpieza diferentes (Corega y Klorhex 0,2% gluconato de clorhexidina) en la rugosidad de la superficie de la dentadura postiza en cuanto a la eficacia de los procedimientos de curado. Se prepararon un total de sesenta muestras en forma de disco con dos métodos diferentes como procesos de curado largos y cortos. Las muestras se dividieron en subgrupos según las soluciones de inmersión (agua destilada, grupo de pastillas Corega y grupo de gluconato de clorhexidina al 0,2%) (n=10). Las muestras se mantuvieron en una solución durante 8 horas al día durante un mes. Se midió el promedio de Ra1 (antes de la exposición al agente de limpieza) y Ra2 (después de la exposición al agente de limpieza) de cada muestra. Para el análisis estadístico se utilizó un ANOVA de dos vías y una prueba post hoc de Tukey. Las soluciones aumentaron significativamente los valores de Ra en ambos grupos acrílicos (p 0,05). El tiempo de curado a largo plazo es muy eficaz para disminuir la rugosidad de la superficie del material de base acrílica.


Assuntos
Prótese Dentária , Desinfetantes de Equipamento Odontológico , Higiene Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA