Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
The Journal of Korean Academy of Prosthodontics ; : 41-48, 2016.
Artigo em Coreano | WPRIM | ID: wpr-122204

RESUMO

Edentulous patients with severe alveolar bone resorption have trouble with using traditional complete denture. In order to overcome these problems, implant-retained overdenture was developed. SFI-bar(R) system can save time and cost compared to other existing bar systems which need complicated laboratory procedures because it can be adjusted directly in a patient's mouth. A 55-year-old male, who had experienced a fractured lower old implant-retained overdenture, wanted a durable and painless denture. The fractured Locator(R) attachments were removed and edentulous mandible was restored with SFI-bar(R). A 77-year-old female with a medical history of the Parkinson's disease and severely absorbed alveolar bone of mandible, wanted to wear a retentive mandibular denture without pain. After placing two implants in front of mental foramen, two adaptors were connected to two implants and a tube bar was connected to the adaptors. A female part fitted to the bar was attached to the new denture. These clinical reports describe two-implant-retained overdenture using the SFI-bar(R) system in mandibular edentulous patients. Since the patients were satisfied esthetically and functionally during 2 years' observation, we would like to report cases.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reabsorção Óssea , Implantes Dentários , Prótese Total , Revestimento de Dentadura , Dentaduras , Mandíbula , Boca , Doença de Parkinson
2.
The Journal of Advanced Prosthodontics ; : 323-328, 2015.
Artigo em Inglês | WPRIM | ID: wpr-44181

RESUMO

PURPOSE: This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+Metaux, Switzerland). MATERIALS AND METHODS: Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, alpha< or =.05). RESULTS: All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION: Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.


Assuntos
Feminino , Humanos , Mastigação , Plásticos , Silicones
3.
The Journal of Korean Academy of Prosthodontics ; : 331-337, 2014.
Artigo em Coreano | WPRIM | ID: wpr-201567

RESUMO

In conventional bar- and clip-retained overdentures, all errors during impression making and cast fabrication result in non-passive fit of bars. SFI bar is prefabricated and assembled in the patient's mouth without the use of soldering, laser welding or conventional bonding techniques, thus reducing stress transmission to, bone loss around the implants and leading to fewer errors and lower costs. A clinical case will be presented below to demonstrate the use of the SFI Bar (Stress Free on Implant Bar) to restore an severe atrophy edentulous maxilla. In this case, no lateral stress could be applied to the implants due to the telescopic design of the bar joints. However, periodic recall check is necessary and long-term clinical results are required.


Assuntos
Atrofia , Revestimento de Dentadura , Articulações , Maxila , Boca , Reabilitação Bucal , Soldagem
4.
The Journal of Advanced Prosthodontics ; : 47-50, 2011.
Artigo em Inglês | WPRIM | ID: wpr-173935

RESUMO

Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar(R) (Cendres et Metaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.


Assuntos
Idoso , Feminino , Humanos , Implantes Dentários , Revestimento de Dentadura , Dentaduras , Mandíbula , Retenção Psicológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA