Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Assunto principal
Intervalo de ano
1.
Journal of Dental Rehabilitation and Applied Science ; : 80-88, 2018.
Artigo em Coreano | WPRIM | ID: wpr-739869

RESUMO

PURPOSE: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. MATERIALS AND METHODS: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. RESULTS: The mean ISQ value of the implants was 69.4 ± 10.2 at the time of implant placement (baseline) and 81.4 ± 6.9 at the time of healing abutment connection (P 0.05). CONCLUSION: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.


Assuntos
Feminino , Humanos , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA