Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Biosci. j. (Online) ; 33(2): 522-536, mar./apr. 2017. tab, ilus, graf
Artigo em Inglês | LILACS | ID: biblio-966210

RESUMO

Shrinkage is a limitation of resin composite, compromising the clinical longevity of the restorative procedure. In an attempt to reduce their harmful effects, researchers have studied monomers with lower values of contraction. As a result, low-shrinkage composites were developed. This study evaluated quantitatively the shrinkage as a function of power density increase based on methacrylates, comparing them with silorane based resin, and qualitatively regarding gap formation between the adhesive interface as function of tooth substrate. Resin Filtek P90 and Filtek Z250 were polymerized with the device Blue Star 3 with 200, 400, 600, 800 and 1000 mW/cm2 keeping volume constant in 12 mm3. For qualitative analysis of restorative interface, class V cavity preparations in bovine incisors were restored in (2x2x2 mm3), photoactivated with the same values of irradiance, and analyzed by scanning electron microscopy at the interface of the wall surrounding enamel, dentin and axial. The quantitative results of the polymerization shrinkage were analyzed by two-way ANOVA and Tukey's test (p<0.05), while qualitative data were submitedd to Mann-Whitney's, Kruskal-Wallis' and Miller's tests. The progressive increase in power density directly influenced the polymerization shrinkage of the materials studied, although the silorane based resin demonstrated significantly lower values. The marginal integrity was influenced by the dental substrate and the power density used.


Este estudo avaliou quantitativamente a contração de polimerização em função do aumento dos valores de densidade de potência irradiados em compósitos à base de metacrilatos e silorano, e qualitativamente a interface restauradora em relação à abertura de fendas marginais, em função da variação do tipo de substrato dentário. As resinas Filtek Z250 e Filtek P90 foram fotoativadas com 200, 400, 600, 800 e 1000 mW/cm2, em um volume constante de 12mm3, e os valores de contração foram aferidos por meio da máquina de ensaios universal. Para análise qualitativa da interface restauradora, preparos cavitários classe V de (2x2x2mm3) foram restaurados em incisivos bovinos, fotoativados com os mesmos valores de irradiância, e analisados em microscopia eletrônica de varredura nas interfaces da parede circundante em esmalte, parede circundante em dentina e parede axial. Os resultados quantitativos da contração de polimerização foram analisados pelo teste ANOVA a dois critérios e Tukey (p<0,05) enquanto para os dados qualitativos os testes Mann- Whitney, Kruskal-Wallis e Miller foram empregados. O aumento progressivo da densidade de potência influenciou diretamente na contração de polimerização dos materiais estudados, não obstante a resina composta à base de silorano ter demonstrado valores significativamente menores. A integridade marginal sofreu influência do substrato dentário bem como da densidade de potência utilizada, para as duas resinas estudadas.


Assuntos
Resinas Compostas , Polimerização , Resinas de Silorano , Metacrilatos
2.
Bauru; s.n; 2011. 161 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-865843

RESUMO

Este estudo avaliou quantitativamente a contração de polimerização em função do aumento dos valores de densidade de potência irradiados em compósitos à base de metacrilatos e silorano, e qualitativamente a interface restauradora em relação à abertura de fendas marginais, em função da variação do tipo de substrato dentário. As resinas Filtek Z250 e Filtek P90 foram fotoativadas com 200, 400, 600, 800 e 1000 mW/cm2, em um volume constante de 12 mm3, e os valores de contração aferidos por meio da máquina de ensaios universal. Para análise qualitativa da interface restauradora, preparos cavitários classe V de 2x2x2 mm foram restaurados em incisivos bovinos, fotoativados com os mesmos valores de irradiância, e analisados em microscopia eletrônica de varredura nas interfaces da parede circundante em esmalte, parede circundante em dentina e parede axial. Os resultados quantitativos da contração de polimerização foram analisados pelo teste ANOVA a dois critérios e Tukey (p0,05), enquanto para os dados qualitativos os testes Mann-Whitney, Kruskal-Wallis e Miller foram empregados. O aumento progressivo da densidade de potência influenciou diretamente na contração de polimerização dos materiais estudados, não obstante a resina composta à base de silorano ter demonstrado valores significativamente menores. A integridade marginal sofreu influência do subtrato dentário bem como da densidade de potência utilizada, para as duas resinas estudadas.


Shrinkage is a limitation of resin composite, compromising the clinical longevity of the restorative procedure. In an attempt to reduce their harmful effects, researchers have studied monomers with lower values of contraction. As a result, low-shrinkage composites wer developed. This study evaluated quantitatively the shrinkage by a universal testing machine as a function of power density increase based on methacrylates, comparing them with silorane based resin, and qualitatively regarding gap formation between the adhesive interface as function of tooth substrate. Resin Filtek P90 and Filtek Z250 were polymerized with the device Blue Star 3 with 200, 400, 600, 800 and 1000 mW/cm2 keeping volume constant in 12 mm3. For qualitative analysis of restorative interface, class V cavity preparations in bovine incisors were restored in (2x2x2 mm), photoactivated with the same values of irradiance, and analyzed by scanning electron microscopy at the interface of the wall surrounding enamel, dentin and axial. The quantitative results of the polymerization shrinkage were analyzed by two-way ANOVA and Tukey's test (p0,05), while qualitative data for the Mann-Whitney, Kruskal-Wallis and Miller were employed. The progressive increase in power density directly influenced the polymerization shrinkage of the materials studied, despite the silorane based resin have demonstrated significantly lower values. The marginal integrity was influenced by the dental substrate and the power density used.


Assuntos
Adesivos Dentinários/química , Adaptação Marginal Dentária , Metacrilatos/química , Polimerização , Resinas Compostas/química , Análise de Variância , Esmalte Dentário/química , Teste de Materiais , Estatísticas não Paramétricas , Fatores de Tempo
3.
Braz. dent. j ; Braz. dent. j;22(2): 105-110, 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-583797

RESUMO

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.


O objetivo do presente estudo foi avaliar a compatibilidade tecidual de um sistema resinoso à base de silorane (FiltekTM Silorane) e de uma resina nanoparticulada à base de metacrilato (FiltekTM Supreme XT), após implantação no tecido conjuntivo subcutâneo de camundongos isogênicos. Um total de 135 camundongos isogênicos BALB/c machos foram randomicamente divididos em 12 grupos experimentais e em 3 grupos controles, de acordo com o material implantado e com o período experimental (7, 21 e 63 dias). Ao final de cada período, os animais foram mortos, sendo os tubos removidos com o tecido circundante e processados para análise microscópica. As lâminas foram submetidas a análise descritiva e análise semi-quantitativa empregando um sistema de escores de 4 pontos (0-3), a fim de avaliar a formação de fibras colágenas e o infiltrado inflamatório. Os dados obtidos foram submetidos à análise estatística por meio do teste de Kruskal Wallis (?=0,05). Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos experimentais e controles, considerando os três períodos de avaliação (p>0,05). As resinas à base de silorane e à base de metacrilato apresentaram resposta tecidual semelhante à do tubo vazio (controle), após implantação no tecido conjuntivo de camundongos isogênicos.


Assuntos
Animais , Masculino , Camundongos , Resinas Compostas/toxicidade , Siloxanas/toxicidade , Tela Subcutânea/efeitos dos fármacos , Resinas Compostas/química , Reação a Corpo Estranho , Colágenos Fibrilares/biossíntese , Implantes Experimentais , Teste de Materiais , Camundongos Endogâmicos BALB C , Metacrilatos/toxicidade , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA