Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 485
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1024469

RESUMO

Objective To observe the influence of different energy windows of the medium-energy general-purpose(MEGP)collimator on image quality,so as to optimize the energy window of yttrium-90(90Y)bremsstrahlung SPECT imaging.Methods 90Y bremsstrahlung spectrum was acquired,and the sensitivity,percentage of the source counts in useful field of view(S/FOV%)and signal-to-background ratio(S/B)of 90Y bremsstrahlung SPECT imaging at MEGP under different energy windows were compared.Results The energy spectrum of 90Y bremsstrahlung was a continuous curve,with the peak of 76.2 keV with MEGP collimator.The images obtained with MEGP collimator were clear,and no significant differences of S/FOV%nor S/B was found between 10%and 20%window width groups(both P>0.05),but the sensitivities of the latter was higher than the former(P<0.05).The sensitivity of 70-90 keV images was relatively high,while the S/FOV%and S/B had decreased.The S/FOV%and S/B of images ranging from 40-60 keV were high,but the sensitivity was low.Images acquired with 100 keV±20%showed fairly high sensitivity,S/FOV%and S/B,which was 69.73%,0.62 and 1.64,respectively.Conclusion When performing 90Y bremsstrahlung SPECT with MEGP collimator,the image quality at 20%window width was better than at 10%window width,and 100 keV±20%showed fairly high sensitivity and not significantly decreased S/FOV%and S/B.

2.
China Medical Equipment ; (12): 51-54, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1026444

RESUMO

Objective:To investigate the application value of digital X-ray radiotherapy and single photon emission computed tomography(SPECT)radionuclide bone imaging in the diagnosis of intertrochanteric fracture of femur.Methods:A total of 70 patients who were diagnosed as intertrochanteric fracture of femur in Shijiazhuang People's hospital from January 2017 to December 2020 were selected,and they were divided into study group and control group according to random number method,with 35 cases in each group.Digital X-ray radiography combined with SPECT radionuclide bone imaging was used in the study group,and digital X-ray radiography was used in the control group.And then,the accuracy of the diagnostic results between the two groups were compared.Results:The radiographic examination indicated that 31 cases(88.6%)of 35 cases in the study group were confirmed,and 24 cases(68.6%)of 35 cases in the control group were confirmed.The diagnostic accuracy rate of the study group was significantly higher than that of the control group,and the difference was statistically significant(x2=4.158,P<0.05).The preoperative imaging diagnosis indicated that diagnosed number of fracture blocks in the study group was(3.57±0.50),which was significantly higher than that(2.67±0.40)in the control group,and the difference of that between two groups was statistically significant(t=8.315,P<0.05).In the actual intraoperative examining for bone continuity,5 cases were continuity and 30 cases were non-continuity.In the bone stability,13 cases were stability and 22 cases were non-stability.The study group was closer to intraoperative bone continuity and bone stability,and the differences of them between two groups were statistically significant(x2=12.857,4.644,P<0.05),respectively.Conclusion:The combination of digital X-ray radiography and SPECT radionuclide bone imaging has higher diagnostic value for intertrochanteric fracture of femur,which can provide important reference for clinical diagnosis.

3.
Artigo em Chinês | WPRIM | ID: wpr-1027926

RESUMO

Objective:To investigate the prognostic value of myocardial flow reserve (MFR) measured by SPECT myocardial blood flow (MBF) quantitative technique in patients with intermediate stenoses of coronary arteries.Methods:From September 2019 to May 2021, patients with intermediate stenoses (50% to 80%) identified by invasive coronary angiography in Fuwai Hospital, Chinese Academy of Medical Sciences, Fuwai Center China Cardiovascular Hospital, and TEDA International Cardiovascular Hospital were prospectively included. All patients underwent a one-day rest/stress SPECT myocardial perfusion imaging (MPI) and SPECT MBF quantification. The radioactivity distribution of each segment of the MPI bullseye polar maps were obtained according to the standard 5-point method to obtain the summed stress score (SSS) and the summed difference score (SDS) to determine the existence of abnormality. ROC curve analysis was used to obtain the optimal prognostic cut-off value for MFR. The primary endpoint was defined as cardiovascular endpoint events. Survival and prognostic analyses were conducted by Kaplan-Meier method and Cox proportional hazard models. The difference of AUCs was analyzed by Delong test.Results:A total of 314 patients (194 males, 120 females; age (59.4±8.6) years) were enrolled. Over a median follow-up duration of 754 (range: 628-914) d, 54 patients had endpoint events. ROC curve showed that the prediction ability of MFR was significantly better than that of conventional MPI (AUCs: 0.713 and 0.512; z=3.76, P<0.001). The optimal prognostic cut-off value for MFR to predict endpoint events in patients with intermediate stenoses was 2.04. Cox multivariate analysis showed that MFR (hazard ratio ( HR)=0.434, 95% CI: 0.282-0.669, P<0.001) was an independent predictor of endpoint events in patients with intermediate stenoses. Kaplan-Meier survival analysis showed that the prevalence of endpoint events in patients with MFR≤2.04 was significantly higher than that in patients with MFR>2.04 (25.4%(43/169) vs 7.6%(11/145); χ2=21.27, P<0.001). Conclusion:The MFR measured by SPECT MBF quantitative technique has an independent predictive value for cardiovascular endpoint events in patients with intermediate stenoses.

4.
Artigo em Chinês | WPRIM | ID: wpr-1027942

RESUMO

Objective:To investigate the value of 99Tc m-hydrazinonicotinamide (HYNIC)-prostate specific membrane antigen(PSMA) SPECT/CT imaging in biochemical recurrence of prostate cancer (PCa). Methods:From January 2018 to March 2023, 112 patients with biochemical recurrence of PCa (age (72.6±6.1) years) who underwent 99Tc m-HYNIC-PSMA SPECT/CT imaging in Henan Provincial People′s Hospital were retrospectively analyzed. According to the level of prostate specific antigen (PSA), patients were divided into 0.2 μg/L<PSA≤1 μg/L group, 1 μg/L<PSA≤2 μg/L group, and PSA>2 μg/L group. According to the Gleason score, patients were divided into Gleason score≥8 group and Gleason score <8 group. The detection rate between groups was analyzed by χ2 test, and the difference of the PSA level between groups was compared by Mann-Whitney U test. Results:PSMA imaging was positive in 77 cases and negative in 35 cases, with the detection rate of 68.8%(77/112). The detection rates of local recurrence, lymph node metastasis, bone metastasis and lung metastasis were 8.9%(10/112), 43.8%(49/112), 28.6%(32/112) and 0.9%(1/112), respectively. The detection rates of 0.2 μg/L<PSA≤1 μg/L, 1 μg/L<PSA≤2 μg/L and PSA>2 μg/L groups were 44.7%(21/47), 8/12 and 90.6%(48/53), respectively ( χ2=24.44, P<0.001). The detection rates of Gleason score ≥8 group and <8 group were 76.4%(55/72) and 55.0%(22/40) ( χ2=5.47, P=0.032); the PSA level between the two groups was statistically different (3.11(0.75, 5.91) and 0.84(0.44, 2.92) μg/L; z=-2.99, P=0.003). Of the patients with PSMA positive imaging, 84.4%(65/77) changed their treatment regimen and 15.6%(12/77) continued to observe or maintain the original treatment plan. Of the patients with PSMA negative imaging, 40.0%(14/35) changed the treatment plan, 51.4%(18/35) continued to observe or maintain the original treatment plan, and 8.6%(3/35) discontinued the original treatment because no tumor metastasis was found. Conclusion:99Tc m-HYNIC-PSMA SPECT/CT imaging can provide reference for the lesion detection, treatment decision-making and follow-up observation of biochemical recurrence of PCa.

5.
Artigo em Chinês | WPRIM | ID: wpr-1031589

RESUMO

【Objective】 To evaluate the role of quantitative flow ratio (QFR) in percutaneous coronary intervention (PCI) by using regadenoson stress dynamic single-photon emission computed tomography (D-SPECT). 【Methods】 We selected 200 patients with unstable angina admitted to Department of Cardiology, Hebei Medical University First Hospital, from June 31, 2021 to June 31, 2023 for elective PCI. The patients were aged 57.56±8.23 years and were randomly divided into a conventional group (n=100) and a QFR group (n=100) according to a random number table. The trial was conducted using a double-blind method. The conventional group received PCI treatment based on the experience of the physician, while the QFR group received PCI treatment based on the QFR measurement results. All enrolled patients underwent pre-operative and 7-day post-operative D-SPECT stress imaging using regadenoson stress D-SPECT, and their images were acquired from short axis, vertical long axis, and horizontal long axis to calculate the total myocardial perfusion score and the total myocardial ischemia segment number under the distribution of 17 myocardial segments. 【Results】 There was no significant difference in the number of myocardial ischemia segments (7.59±3.14 vs. 7.48±3.36, P=0.811) or the total myocardial perfusion score (15.87±7.61 vs. 15.63±5.97, P=0.860) between the two groups before PCI. The number of myocardial ischemia segments (5.58±3.36 vs. 6.51±2.14, P=0.020) and the total myocardial perfusion score (10.55±4.41 vs. 12.96±6.50, P=0.002) in the QFR group were significantly better than those in the conventional group 7 days after PCI (P<0.05). 【Conclusion】 Applying QFR guidance for PCI can better improve the degree of myocardial ischemia in patients.

6.
Journal of Practical Radiology ; (12): 270-274, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1020199

RESUMO

Objective To evaluate the maturity and metabolic status of heterotopic ossification(HO)by single-photon emission computed tomography(SPECT)/CT fusion bone imaging.Methods The clinical and SPECT/CT fusion bone imaging data of 57 patients with HO confirmed by pathology or follow-up were analyzed retrospectively.HO was graded by CT,and the characteristics of radioactive concentration of HO were analyzed.Results Of 57 cases,single lesion in 52 cases,and multiple lesions in 5 cases,with a total of 63 lesions,mostly located in the hip joint(55.6%,35/63)and thigh(19.0%,12/63).There were 41 lesions in the middle stage and 22 lesions in the late stage.In the visual evaluation of SPECT/CT fusion bone imaging,the middle stage lesions were mostly clumps or flakes,with moderate or high radioactive concentration(75.6%,31/41),furthermore,the concentration range was larger than or equal to the total or limited range of CT ossification(21/41,50.1%),with high concentration mainly located in the mixed areas of ossification density.The concentration of the late stage lesions was mostly non-radioactive(72.7%,16/22).Conclusion SPECT/CT fusion bone imaging can show the range,degree and maturity of HO radioactive concentration,and can accurately locate the area with osteoblastic activity,which provides scientific basis for the selection of surgical timing.

7.
Journal of Practical Radiology ; (12): 306-310, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1020208

RESUMO

Objective To investigate the value of single photon emission computed tomography/computed tomography(SPECT/CT)fusion imaging for post-implantation dose verification of 125I particles in patients with bone metastases.Methods Forty patients with metastatic bone tumors treated with 125I particles implantation were selected.Within 24 h after 125I particles implantation,patients underwent SPECT/CT fusion imaging and the radioactivity per unit(RPU)was calculated.The treatment planning system(TPS)was then used to obtain the isodose profiles of SPECT/CT fusion imaging results and to calculate the tumor target coverage.The patient's preoperative and postoperative 1 month clinical outcomes,including local tumour remission,pain assessment,quality of life and serum alkaline phosphatase(ALP)levels were compared,and a receiver operating characteristic(ROC)curve was applied to evaluate the predictive value of tumor target coverage on postoperative outcomes.Results The mean number of particles implanted in the target area was 32.52±12.87.Within 24 h of 125I particles implantation,SPECT/CT fusion imaging analysis confirmed a strong positive correlation between the RPU of the radioactive concentration area and the mean dose received by the patient(r=0.786,P<0.05).The predicted area under the curve(AUC)for local tumor remission,pain relief,quality of life improvement and change in ALP levels was 0.789,0.757,0.804 and 0.833,respectively.Conclusion SPECT/CT fusion imaging can be used for postoperative dose verification of 125I particles for metastatic bone tumors and has some predictive value for clinical outcomes.

8.
Artigo em Espanhol | LILACS, UNISALUD, BINACIS | ID: biblio-1552286

RESUMO

La evaluación de la perfusión miocárdica con SPECT combina una prueba de esfuerzo (ergometría o estrés farmacológico) junto a imágenes de perfusión con radioisótopos. Este estudio es útil para establecer el diagnóstico de enfermedad arterial coronaria, estratificar el riesgo de infarto y tomar decisiones terapéuticas. Un resultado normal aporta un alto valor predictivo negativo, es decir, una muy baja probabilidad de que el paciente presente eventos cardiovasculares. El hallazgo de signos de isquemia en la ergometría podría poner en jaque el valor predictivo negativo de una perfusión normal. En presencia de este resultado, el paso siguiente es evaluar los predictores de riesgo en la ergometría, el riesgo propio del paciente en función de los antecedentes clínicos y el puntaje cálcico coronario, cuando este se encuentra disponible. Ante la presencia concomitante de otros marcadores de riesgo se sugiere completar la evaluación con un estudio anatómico.El uso de nuevas tecnologías podría mejorar la precisión en la predicción de eventos. (AU)


Assessment of myocardial perfusion with SPECT combines a stress test (ergometry or pharmacological stress) with radioisotope perfusion imaging. This test is helpful to diagnose coronary artery disease, stratify the risk of heart attack, and make therapeutic decisions. A normal result provides a high negative predictive value; therefore, the probability of cardiovascular events is very low. Signs of ischemia on an ergometry could jeopardize the negative predictive value of normal perfusion. In this clinical setting, the next step is to evaluate the risk predictors in the stress test, the individual risk based on the clinical history, and the coronary calcium score when available. Given the simultaneous presence of other risk markers,completing the evaluation with an anatomical study is suggested. The use of new technologies could improve the accuracy of event prediction. (AU)


Assuntos
Humanos , Tomografia Computadorizada de Emissão de Fóton Único , Ergometria , Isquemia Miocárdica/diagnóstico por imagem , Medição de Risco/métodos , Imagem de Perfusão do Miocárdio , Infarto do Miocárdio/prevenção & controle , Prognóstico , Sobrevida , Doença da Artéria Coronariana/diagnóstico por imagem , Sensibilidade e Especificidade , Teste de Esforço , Tomada de Decisão Clínica
9.
Radiol. bras ; 56(3): 137-144, May-June 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1449034

RESUMO

Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.


Resumo Objetivo: Desenvolver corregistro automático e testar seu desempenho com ou sem marcador fiducial em imagens de tomografia computadorizada de emissão de fóton único (SPECT). Materiais e Métodos: Três SPECT/CTs foram adquiridas para cada rotação de um simulador de Jaszczak em relação ao eixo da maca (0°, 5° e 10°), com e sem fiducial. Dois métodos de corregistro inelástico foram aplicados - SPM12 e NMDose-coreg -, e a porcentagem do erro quadrático médio (%RMSE) foi usada para analisar a qualidade do corregistro. Uniformidade, contraste e resolução foram medidos antes e após o corregistro. NMDose com corregistro automático foi usado para calcular a dose renal de 12 pacientes tratados com 177Lu-DOTATATE e comparado com OLINDA/EXM. Resultados: A marcação fiducial não modificou a qualidade do corregistro das imagens SPECT, medida pela %RMSE (p = 0,40). Não houve impacto na uniformidade, contraste e resolução após o corregistro de imagens adquiridas com ou sem fiduciais. Aplicação clínica preliminar mostrou tempo total de processamento de 9 ± 3 min/paciente para NMDose e 64 ± 10 min/paciente para OLINDA/EXM, com alta correlação entre ambos, apesar de menor dose renal em NMDose. Conclusão: NMDose-coreg permite o corregistro rápido de imagens SPECT, sem perda de uniformidade, contraste ou resolução. O uso da marcação fiducial não aumentou a precisão do corregistro em fantomas.

10.
Artigo em Chinês | WPRIM | ID: wpr-961156

RESUMO

Objective @#To investigate the feasibility of epidural catheters in parotid gland duct anastomosis and the function of the affected side gland after parotid gland duct anastomosis. @* Methods@# Thirteen patients who were treated in the Department of Oral and Maxillofacial Surgery of Xuzhou Central Hospital using an epidural catheter as the scaffold for parotid gland catheter anastomosis were enrolled from Jan. 2019 to June 2021. The swelling, salivary fistula and catheter patency in the parotid gland area were evaluated two weeks after the operation. 99mTcO4- single photon emission computed tomography (SPECT) was used for quantitative detection of salivary gland secretion function@*Results@# Thirteen patients had no swelling or salivary fistula in the parotid gland area of the affected side two weeks after the operation, and the catheter secretion was unobstructed. There was no significant difference in the uptake rate between the parotid gland on the affected side and the parotid gland on the healthy side (t = -0.859, P = 0.399), and there was no significant difference in the excretion rate between the parotid gland on the affected side and the parotid gland on the healthy side (t = 0.693, P = 0.495). The parotid gland excretion function of the affected side was excellent three months after the operation.@*Conclusion @#Parotid duct anastomosis with an epidural catheter as the stent has good feasibility, and parotid gland secretion function recovers well after the operation, which is worthy of clinical application.

11.
Artigo em Chinês | WPRIM | ID: wpr-1024179

RESUMO

Reflex epilepsy is a type of partial or generalized seizure induced by specific or nonspecific stimulation in individuals without a prior history of seizures. Mahjong epilepsy is a special form of complex reflex epilepsy induced by playing or watching mahjong, with a low incidence rate and complex pathogenesis. Due to the lack of comprehensive understanding, clinical studies of mahjong epilepsy are still mainly based on case reports. Now, we will analyze and summarize the etiology, pathogenesis, clinical diagnosis, electroencephalogram, treatment, and prognosis of mahjong epilepsy to raise awareness of mahjong epilepsy among clinical medical workers.

12.
Artigo em Chinês | WPRIM | ID: wpr-1027882

RESUMO

Objective:To explore the potential clinical value of 99Tc m-methoxyisobutylisonitrile(MIBI) SPECT/CT muscle imaging in the diagnosis of cervical dystonia (CD). Methods:From January 2021 to April 2022, 50 patients with CD (14 males, 36 females; age (45.8±12.5) years) who were treated in Second Affiliated Hospital of Soochow University were prospectively included. The 99Tc m-MIBI SPECT/CT muscle imaging results of 400 pieces of muscle (bilateral sternocleidomastoid, musculus scapulae, splenius capitis and musculus trapezius; each of 100 pieces) in 50 patients were analyzed and divided into the dystonic muscle group and normal muscle group according to the electromyography (EMG). Toronto western spasmodic torticollis rating scale (TWSTRS) score, SUV max and target-to-background ratio (TBR) of single superficial cervical muscle and total cervical muscle, and EMG diagnosis results were obtained before botulinum toxin injection. ROC curves of SUV max and TBR of dystonic muscles were constructed to determine AUCs and the difference was compared by Delong test. Differences of SUV max and TBR between 2 groups were analyzed by Mann-Whitney U test. Spearman rank correlation analysis was used to analyze the correlation of SUV max, TBR and TWSTRS scores of total cervical muscle. Results:There were 205 pieces of muscle in dystonic muscle group and 195 pieces of muscle in normal muscle group. The uptake of 99Tc m-MIBI in dystonic muscle was significantly increased in CD patients, and the non-whole uptake of 99Tc m-MIBI was increased in some dystonic muscles, which was manifested as uneven uptake of the whole muscle. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of visual analysis were 95.12%(195/205), 75.90%(148/195), 85.75%(343/400), 85.58%(195/242) and 93.67%(148/158), respectively. There were significant differences of SUV max (1.74(1.42, 2.12) vs 0.92(0.81, 0.99)) and TBR (2.55(1.92, 3.27) vs 1.44(1.22, 1.73)) between the dystonic muscle group and the normal muscle group ( z value: -15.29, -12.69, both P<0.001). The diagnostic efficiency of SUV max in dystonic muscle was better than TBR (AUC: 0.942 vs 0.867; z=5.03, P<0.001). SUV max, TBR and TWSTRS score in the neck muscles of patients with CD showed positive correlation ( rs values: 0.44, 0.45, both P<0.001). Conclusion:99Tc m -MIBI SPECT/CT muscle imaging is a good diagnostic method for dystonic muscle in patients with CD.

13.
Artigo em Chinês | WPRIM | ID: wpr-993548

RESUMO

Objective:To evaluate the efficacy of balloon pulmonary angioplasty (BPA) in chronic thromboembolic pulmonary hypertension (CTEPH) using 99Tc m-macroaggregated albumin (MAA) pulmonary perfusion tomography imaging. Methods:Twenty-five patients (4 males, 21 females; age (56.5±12.3) years) with CTEPH who underwent BPA from January 2017 to April 2020 in Beijing Chaoyang Hospital, Capital Medical University were enrolled retrospectively. Effect of BPA on the improvement of pulmonary lobe/pulmonary segment perfusion was analyzed, and the proportions of improved and unimproved pulmonary lobe/pulmonary segment perfusion by BPA were calculated. The percentages of perfusion defect scores (PPDs%) of lung perfusion tomography imaging before BPA and after 4-6 times BPA were compared and analyzed (paired t test). The correlations between PPDs% and mean pulmonary artery pressure (mPAP) before BPA and after BPA were analyzed respectively, and the correlation between decreased percentage of PPDs% and decreased percentage of mPAP after BPA were also analyzed (Pearson correlation analysis). Results:Among 150 lobes of 25 patients, 96.00%(144/150) lobes showed perfusion abnormalities before BPA. After BPA, 11.11%(16/144) showed complete improvement, 57.64%(83/144) showed partial improvement, and 31.25%(45/144) showed no improvement. Among 450 pulmonary segments of 25 patients, 62.44%(281/450) showed perfusion abnormalities before BPA. After BPA, 30.60%(86/281), 37.37%(105/281), 32.03%(90/281) showed complete, partial and no improvement, respectively. The post-BPA PPDs% was significantly lower than that of pre-BPA ((39.08±10.88)% vs (57.88±10.46)%; t=10.40, P<0.001). The post-BPA mPAP was significantly lower than that of pre-BPA ((32.36±10.57) vs (49.08±10.23) mmHg; 1 mmHg=0.133 kPa; t=10.25, P<0.001). There was no significant correlation between PPDs% and mPAP either before BPA ( r=0.01, P=0.953) or after BPA ( r=0.27, P=0.199), but there was a positive correlation between the changes of PPDs% and mPAP ( r=0.40, P=0.045). Conclusions:BPA can significantly improve the pulmonary perfusion and reduce mPAP in CTEPH patients. Pulmonary perfusion tomography imaging can be used to evaluate the efficacy of BPA in CTEPH.

14.
Artigo em Chinês | WPRIM | ID: wpr-993568

RESUMO

Objective:To evaluate the relationship between regional coronary flow reserve (CFR) obtained from cadmium-zinc-telluride SPECT(CZT SPECT) myocardial functional perfusion imaging (MFPI) and invasive fractional flow reserve (FFR) measured during coronary angiography (CAG) and its clinical value in guiding coronary interventions.Methods:Forty-two patients (30 males, 12 females, age (63.3±9.8) years) who completed CZT SPECT MFPI in the First Affiliated Hospital of Nanjing Medical University from June 2022 to September 2022 and underwent CAG within 3 months were included retrospectively. The concordance of CFR and FFR for diagnosing myocardial ischemia (CFR<2.0 and FFR<0.8) was calculated at the vascular level. The diagnostic efficacy of coronary stenosis≥70% for decreased myocardial blood flow (CFR<2.0) was calculated. Kappa test was used to analyze the data. Results:A total of 126 major coronary arteries were identified in 42 patients, of which 30(23.8%) had a CFR<2.0 by CZT SPECT and 33(26.2%) had stenosis≥70% in CAG. A total of 32 coronary vessels were performed with MFPI CFR and FFR measurements, of which 6 were both decreased and 21 were both normal, so the concordance rate was 84.4%(27/32)( Kappa=0.612, P<0.001). Among 33 coronary vessels with stenosis≥70%, 13 were with CFR≥2.0. Among 30 coronary vessels with CFR<2.0, 10 were with stenosis<70%. When using stenosis≥70% to diagnose CFR decreasing, the sensitivity was 66.7%(20/30), specificity was 86.5%(83/96), positive predictive value was 60.6%(20/33), negative predictive value was 89.2%(83/93), and accuracy was 81.7%(103/126). Conclusions:The concordance between CFR and FFR for the diagnosis of myocardial ischemia is good. Nearly 1/3 of the coronary arteries with decreased CFR have stenosis<70%, whereas nearly 40% of the coronary arteries with stenosis≥70% are not result in myocardial ischemia. Regional CFR determined by CZT SPECT may have potentially significant clinical value in the diagnosis of coronary artery disease and decision-making of coronary intervention.

15.
Artigo em Chinês | WPRIM | ID: wpr-993570

RESUMO

Objective:To establish the normal reference value of left ventricular function parameters by cadmium-zinc-tellurium (CZT) SPECT stress gated myocardial perfusion imaging (G-MPI) in low-likelihood of stable coronary artery disease (SCAD).Methods:From March 2022 to August 2022, 348 consecutive SCAD patients (146 males, 202 females, age (58±10) years) who underwent exercise or pharmacological stress G-MPI (CZT SPECT) in Beijing Anzhen Hospital, Capital Medical University were retrospectively recruited. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) were acquired using quantitative gated SPECT (QGS) analysis. EDV and ESV were corrected by body surface area (BSA) to obtain EDV index (EDVI) and ESV index (ESVI), respectively. Independent-sample t test, one-way analysis of variance and Mann-Whitney U test were used for data analysis. The influences of EDV, ESV, EDVI, ESVI and LVEF were analyzed by multiple regressions for linear models. Results:There were 314 patients with low-likelihood of SCAD (128 males, 186 females, age (58±10) years) and 34 normal controls (18 males, 16 females, age (55±10) years). There were no significant differences of basic clinical characteristics and left ventricular function parameters in different genders between 2 groups ( z values: from -1.74 to -0.02, t values: from -1.16 to 1.17, all P>0.05). Using the 95% CI as the cut-off value for left ventricular function parameters in patients with a low-likelihood of SCAD, the upper limits of EDV, ESV, EDVI and ESVI in females and males were 84 and 111 ml, 30 and 44 ml, 47 and 54 ml/m 2, 17 and 21 ml/m 2, respectively, and the lower limit of LVEF in females and males were 58% and 55%, respectively. In the low-likelihood of SCAD group, the EDV ((58±13) vs (77±17) ml) and ESV ((16±7) vs (26±9) ml) of females were smaller than those of males ( t values: 10.65, 10.35, both P<0.001), while LVEF of females was higher than that of males ((72±7)% vs (67±6)%; t=-6.23, P<0.001). However, there were no significant differences in left ventricular function parameters among different age groups with the same gender ( F values: 0.12-2.19, all P>0.05). Based on multiple regression for linear models, the primary predictors of EDV, ESV and LVEF were gender and weight ( β values: from -0.380 to 0.358, all P<0.05). Conclusions:Normal reference values of left ventricular function parameters are established by CZT SPECT stress G-MPI in low-likelihood of SCAD patients. Left ventricular EDV and ESV of females are smaller than those of males, while LVEF of females is higher than that of males. The influence of gender on left ventricular function parameters should be considered in clinical practice.

16.
Artigo em Chinês | WPRIM | ID: wpr-993590

RESUMO

Objective:To study the value of myocardial perfusion imaging (MPI) and coronary flow reserve (CFR) combined with coronary artery calcium score (CACS) in the diagnosis of obstructive coronary artery disease (CAD).Methods:From January 2019 to December 2020, 96 confirmed or suspective CAD patients (65 males, 31 females; age: 30-81 years) who completed rest/stress MPI, CFR and CACS defection in Fuwai Central China Cardiovascular Hospital were retrospectively analyzed. Coronary angiography (CAG) was used as the diagnostic standard to calculate the sensitivity and accuracy of MPI, CFR and MPI/CFR combined with CACS in the diagnosis of CAD. The χ2 test was used to compare the diagnostic efficiency of different methods. Results:The diagnostic sensitivity of MPI was 76.06%(54/71), and the accuracy was 75.00%(72/96), while the sensitivity increased to 97.18%(69/71; χ2=13.67, P<0.001) and the accuracy increased to 87.50%(84/96; χ2=4.92, P=0.020) with significant differences after combined with CACS. The sensitivity and accuracy of CFR were 91.55%(65/71)and 87.50%(84/96), which increased to 97.18%(69/71; χ2=2.12, P=0.137) and 89.58%(86/96; χ2=0.21, P=0.411) with no significant differences after combined with CACS. The sensitivity of MPI in the diagnosis of three-vessel CAD was 70.00%(21/30), which increased to 100%(30/30; χ2=7.75, P=0.004) after combined with CACS; while the sensitivity of MPI combined with CACS in the diagnosis of single-vessel and double-vessel CAD were not significantly improved ( χ2 values: 3.29, 1.51, P values: 0.114, 0.416). Conclusion:The combination of MPI and CACS can significantly improve the diagnostic efficiency of CAD, contributed by the improvement of the diagnostic sensitivity in three-vessel disease; whereas the diagnostic efficiency of CFR for CAD is not significantly improved after combined with CACS.

17.
Artigo em Chinês | WPRIM | ID: wpr-993591

RESUMO

Objective:To evaluate the value of 99Tc m-methoxyisobutylisonitrile(MIBI) SPECT/CT imaging for the identification of dystonic muscles in patients with primary cervical dystonia (PCD). Methods:A total of 10 patients with PCD (3 males, 7 females, age (47.3±9.9) years) and 10 healthy subjects (4 males, 6 females, age (43.5±9.4) years; control group) between August 2019 and October 2021 in China-Japan Friendship Hospital were enrolled prospectively. All subjects underwent 99Tc m-MIBI SPECT/CT scan. The SUV max of 8 bilateral representative muscles, including rectus capitis posterior major, obliquus capitis inferior, splenius capitis, semispinalis, sternocleidomastoid, trapezius, musculus scalenus muscle and levator scapulae were evaluated in control group. In PCD group, muscles with abnormal uptake were determined. ROI was drawn and SUV max was measured. Independent-sample t test was used to analyze the differences of SUV max between normal and abnormal muscles. The detecting rates of neck MRI and SPECT/CT for abnormal muscles were analyzed by χ2 test. Results:Normal muscles of healthy subjects showed mild symmetrical radioactivity distribution, with the SUV max of 1.10±0.19. A total of 60 muscles with abnormal uptake in 10 patients were found, including 7 rectus capitis posterior major, 10 obliquus capitis inferior, 8 splenius capitis, 8 semispinalis, 10 sternocleidomastoid, 5 trapezius, 3 musculus scalenus muscle and 9 levator scapulae. The SUV max of muscles with abnormal uptake was 1.81±0.43, which was higher than that of normal muscles ( t=17.05, P<0.001). Only 30 pieces abnormal hypertrophy muscle were found by neck MRI, and the detecting rate was much lower than that of SPECT/CT (18.75%(30/160) vs 37.50%(60/160); χ2=28.03, P<0.001). Conclusion:99Tc m-MIBI SPECT/CT may be a useful method for identifying dystonic muscles and a guide to precision therapy in patients with PCD.

18.
Journal of Preventive Medicine ; (12): 152-154, 2023.
Artigo em Chinês | WPRIM | ID: wpr-962276

RESUMO

Objective@#To investigate the changes of ambient dose equivalent rate in 99mTcO4- single photon emission computed tomography (SPECT) of the thyroid among patients with hyperthyroidism, so as to provide insights into radiation protection guidance.@*Methods@#Patients with hyperthyroidism who underwent 99mTcO4- SPECT of the thyroid in a tertiary hospital were enrolled. The ambient dose equivalent rate was measured at different time points following 99mTcO4- infection and at sites with different distances from patients' neck, and the effects of time post-injection, distance from patients' neck, 24-hour thyroidal radioiodine uptake and thyroid weight on the ambient dose equivalent rate were examined using a generalized linear mixed model.@*Results@#Totally 100 patients with hyperthyroidism were enrolled, including 24 men and 76 women and with a mean age of (38.5±14.0) years. The generalized linear mixed model was statistically significant (F=6 610.165, P<0.001), and patients' thyroid weight, time post-injection and distance from patients' neck significantly affected the ambient dose equivalent rate (F=57.967, 15 988.574, 11 200.645, all P<0.001), and the ambient dose equivalent rate positively correlated with patients' thyroid weight and negatively correlated with time post-injection and distance from patients' neck.@*Conclusions@#The ambient dose equivalent rate is affected by patients' thyroid weight, time post-injection and distance from patients' neck among patients with hyperthyroidism undergoing 99mTcO4- SPECT of the thyroid. Delay in contact with patients or keeping distance from patients may be effective for radiation protection.

19.
Artigo em Chinês | WPRIM | ID: wpr-973178

RESUMO

@#The combination of conventional single-photon emission computed tomography (SPECT) and computed tomography (CT) may display the morphological changes of lesions and distribution of imaging agents, which is effective to improve the imaging sensitivity and specificity of tumors and non-tumor diseases. SPECT/CT is feasible to analyze the anatomical structure and metabolic status through displaying multi-site lesions with single imaging, thereby improving differential diagnosis and diagnostic accuracy of diseases. In addition, the novel mixed SPECT/CT device shortens the duration of image acquisition and provides precise attenuation correction and fusion imaging, which provides a scientific basis for rational selection of treatment regimens in clinical practice. This review describes the advances in clinical application of SPECT/CT.

20.
Organ Transplantation ; (6): 605-2023.
Artigo em Chinês | WPRIM | ID: wpr-978505

RESUMO

With the changes of the disease spectrum of liver transplantation and organ allocation system, more and more patients complicated with cardiovascular complications have entered the waiting list for liver transplantation. However, surgical stress, severe infection and adverse reactions of immunosuppressive drugs will significantly increase the risk of postoperative cardiac complications and affect the short-and long-term survival of the recipients. Therefore, comprehensive evaluation of cardiac structure and function of the recipients before liver transplantation is of significance for improving clinical prognosis of the recipients. In this article, the main causes for the increased risk of heart disease during the perioperative period of liver transplantation, the time and methods of heart disease risk assessment for liver transplant recipients were reviewed, and existing assessment approaches for common heart diseases before liver transplantation were illustrated, aiming to provide reference for further reducing the incidence of heart complications after liver transplantation, improving the survival rates of grafts and recipients and enhancing clinical prognosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA