Rev. bras. anestesiol ; 70(2): 175-177, Mar.-Apr. 2020.
Artigo em Inglês, Português | LILACS | ID: biblio-1137157

RESUMO

Abstract Background: The Argon Beam Coagulator (ABC) achieves hemostasis but has potential complications in the form of argon gas embolisms. Risk factors for embolisms have been identified and ABC manufacturers have developed guidelines for usage of the device to prevent embolism development. Case report: A 49 year-old male with history of recurrent cholangiocarcinoma status post resection presented for resection of a cutaneous biliary fistula. Shortly after initial use of the ABC, the patient underwent cardiac arrest. After resuscitation, air bubbles were observed in the left ventricle via Transesophageal Echo (TEE). Conclusion: Although argon embolisms have been described more commonly during laparoscopies, this patient most likely experienced an argon gas embolism during an open resection of a cutaneous biliary fistula via the biliary tract or vein with possible transpulmonary passage of the embolism. Consequently, a high degree of suspicion should be maintained for an argon gas embolism during ABC use in laparoscopic, open, and cutaneous surgeries.


Resumo Introdução: A Coagulação por Feixe de Argônio (CFA) promove hemostasia, mas pode levar a complicações na forma de embolia por gás argônio. Os fatores de risco para embolias foram identificados e os fabricantes de aparelhos de CFA desenvolveram diretrizes para o uso do dispositivo para impedir a ocorrência de embolia. Relato de caso: Paciente masculino de 49 anos com história de colangiocarcinoma recorrente pós-ressecção foi submetido à ressecção de fístula cutâneo-biliar. Logo após o início do uso do aparelho de CFA, o paciente apresentou parada cardíaca. Após o retorno da atividade cardíaca, a Eecocardiografia Transesofágica (ETE) detectou bolhas de ar no ventrículo esquerdo. Conclusões: Embora a embolia associada ao argônio seja mais frequentemente descrita durante laparoscopia, este paciente mais provavelmente apresentou embolia provocada pelo argônio durante cirurgia aberta para ressecção de fístula cutâneo-biliar, após o argônio ganhar acesso à circulação sanguínea através das vias biliares ou da veia biliar e possível passagem do êmbolo pela circulação pulmonar. Desta maneira, deve-se suspeitar de embolia por argônio, de forma judiciosa, durante o uso de CFA em procedimento cirúrgico laparoscópico, aberto ou cutâneo.


Assuntos
Humanos , Masculino , Fístula Biliar/cirurgia , Fístula Cutânea/cirurgia , Embolia Aérea/etiologia , Coagulação com Plasma de Argônio/efeitos adversos , Complicações Intraoperatórias/etiologia , Pessoa de Meia-Idade
2.
Arq. bras. med. vet. zootec ; 67(1): 55-61, 2/2015. tab, fig
Artigo em Inglês | LILACS | ID: lil-741112

RESUMO

In the current experimental study, two different instruments were compared for prophylactic hemostasis during a 3-port technique of laparoscopic ovariohysterectomy (OVH) in bitches. Moreover, the need for port enlargement for specimen retrieval using 5mm or 10mm trocartes, technical difficulties and complications were assessed. Ultrasonic energy and a vascular sealing system were tested. Duration of surgery, patient weight and diameter of the uterine arteries and veins were compared among the groups. Fifteen dogs randomly divided into three groups (GI, GII, GIII) were submitted to ovariohysterectomy with hemostasis from the use of ultrasonic scalpel or vascular sealing equipment. In GI and GII the LigaSure(tm) impedance-controlled bipolar vessel-sealing device was used, differing in the size of trocartes used between groups, and in GIII Autosonix(tm) was used. Patients' weight, duration of surgery, technical difficulties and complications were compared among the groups. Statistical analysis showed no difference between the data analyzed among the groups. In conclusion, both methods of hemostasis were effective for 3-port total laparoscopic ovariohysterectomy in bitches. However, 5mm trocartes were not adequate for retrieval of the uterus and ovaries without need for enlargement of the port incision.


No presente experimento, foram comparados dois diferentes equipamentos, um com emprego de energia ultrassônica, e outro utilizando sistema de selamento vascular, como única forma de hemostasia em ovário-histerectomias laparoscópicas com três portais em cadelas. Ademais, a necessidade de ampliação da incisão do portal de 5mm ou de 10mm para a remoção dos espécimes ressecados, dificuldades técnicas e complicações foram avaliadas. Quinze cadelas aleatoriamente distribuídas em três grupos (GI, GII, GIII) foram submetidas à ovário-histerectomia com hemostasia a partir da utilização de bisturi ultrassônico ou equipamento de selamento vascular. Nos GI e GII foi utilizado um sistema de selamento vascular eletrotérmico bipolar (LigaSure(r)), diferindo-se no tamanho dos portais utilizados; em GIII foi utilizado bisturi ultrassônico (Autosonix(r)). A análise estatística não demonstrou diferença significativa entre os dados analisados nos três grupos. Conclui-se que ambos os métodos de hemostasia utilizados mostraram-se adequados e viabilizaram a realização de ovário-histerectomia laparoscópica em cadelas. Todavia, o trocarte de 5mm não foi adequado para remoção do útero e ovários sem necessidade de ampliação da incisão de acesso.


Assuntos
Animais , Feminino , Cães , Ovariectomia/veterinária , Laparoscopia/estatística & dados numéricos , Laparoscopia/veterinária , Histerectomia