Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Biomedical Engineering Letters ; (4): 413-424, 2019.
Artigo em Inglês | WPRIM | ID: wpr-785532

RESUMO

Segmentation of fundamental heart sounds–S1 and S2 is important for automated monitoring of cardiac activity including diagnosis of the heart diseases. This pa-per proposes a novel hybrid method for S1 and S2 heart sound segmentation using group sparsity denoising and variation mode decomposition (VMD) technique. In the proposed method, the measured phonocardiogram (PCG) signals are denoised using group sparsity algorithm by exploiting the group sparse (GS) property of PCG signals. The denoised GS-PCG signals are then decomposed into subsequent modes with specific spectral characteristics using VMD algorithm. The appropriate mode for further processing is selected based on mode central frequencies and mode energy. It is then followed by the extraction of Hilbert envelope (HEnv) and a thresholding on the selected mode to segment S1 and S2 heart sounds. The performance advantage of the proposed method is verified using PCG signals from benchmark databases namely eGeneralMedical, Littmann, Washington, and Michigan. The proposed hybrid algorithm has achieved a sensitivity of 100%, positive predictivity of 98%, accuracy of 98% and detection error rate of 1.5%. The promising results obtained suggest that proposed approach can be considered for automated heart sound segmentation.


Assuntos
Benchmarking , Diagnóstico , Cardiopatias , Ruídos Cardíacos , Coração , Métodos , Michigan , Washington
2.
Investigative Magnetic Resonance Imaging ; : 215-223, 2016.
Artigo em Inglês | WPRIM | ID: wpr-213520

RESUMO

PURPOSE: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called “Slice Encoding for Metal Artifact Correction (SEMAC)” is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. MATERIALS AND METHODS: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, l1 minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. RESULTS: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. CONCLUSION: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.


Assuntos
Artefatos , Análise dos Mínimos Quadrados , Imageamento por Ressonância Magnética , Métodos , Ruído , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA