Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. j. pharm. sci ; 50(2): 423-429, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722195

RESUMO

The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle), 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS) as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA) method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.


O presente estudo descreve o desenvolvimento e validação de um método de dissolução in vitro para avaliação da liberação de diclofenaco potássico suspensão oral. O teste de dissolução foi desenvolvido e validado de acordo com as diretrizes internacionais. Parâmetros como linearidade, especificidade, precisão e exatidão foram avaliados, bem como a influência da velocidade de rotação e a concentração de tensoativono meio. Depois de selecionar as melhores condições, o método foi validado usando o aparato 2 (pás), velocidade de rotação de 50 rpm, 900 mL de água com 0,3% de lauril sulfato de sódio (LSS) como meio de dissolução a 37,0 ± 0,5 ºC. As amostras foram analisadas pelo método de CLAE-UV (PDA). Os resultados obtidos foram satisfatórios para os parâmetros avaliados. O método desenvolvido pode ser útil na rotina de controle de qualidade para as indústrias farmacêuticas que produzem suspensões orais contendo diclofenaco potássico.


Assuntos
Diclofenaco/classificação , Cromatografia Líquida de Alta Pressão/métodos , Estudo de Validação , Controle de Qualidade , Dissolução/métodos
2.
Braz. j. pharm. sci ; 49(3): 589-597, July-Sept. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-689913

RESUMO

A rapid, simple and low cost method was developed to determine diclofenac potassium (DP) in oral suspension, using a reverse-phase column (C8, 150 mm x 4.6 mm, 5 µm), mobile phase containing methanol/buffer phosphate (70:30 v/v, pH 2.5), at a flow rate of 1.0 mL/min, isocratic method, and ultraviolet detection at 275 nm. A linear response (r = 1.0000) was observed in the range of 10.0-50.0 µg/mL. Validation parameters such as linearity, specificity, precision, accuracy and robustness were evaluated. The method presented precision (repeatability: relative standard deviation = 1.21% and intermediate precision: between-analyst = 0.85%). The specificity of the assay was evaluated by exposure of diclofenac potassium under conditions of stress such as hydrolysis, photolysis, oxidation and high temperature. The method presented accuracy values between 98.28% and 101.95%. The results demonstrate the validity of the proposed method that allows determination of diclofenac potassium in oral suspension and may be used as an alternative method for routine analysis of this product in quality control.


Desenvolveu-se método simples, de baixo custo para determinar o diclofenaco potássico (DP) em suspensão oral, usando coluna de fase reversa (C8, 150 mm x 4,6 mm, 5 µm), fase móvel contendo metanol/tampão fosfato (70:30 v/v, pH 2,5), com fluxo de 1,0 mL/min, método isocrático e detecção no ultravioleta a 275 nm. Observou-se resposta linear (r = 1,0000) na faixa de 10,0-50,0 µg/mL. Avaliaram-se parâmetros de validação, como linearidade, especificidade, precisão, exatidão e robustez. O método apresentou precisão (repetibilidade: desvio padrão relativo = 1,21% e precisão intermediária: entre analista = 0,85%). A especificidade do ensaio foi avaliada pela exposição do diclofenaco potássico a condições de estresse, tais como hidrólise, fotólise, oxidação e alta temperatura. O método apresentou valores de exatidão entre 98,28% e 101,95%. Os resultados mostram a validade do método proposto, que permite a determinação de diclofenaco potássico em suspensão oral e pode ser utilizado como alternativa para análise de rotina desse produto no controle de qualidade.


Assuntos
Diclofenaco/análise , Cromatografia Líquida/métodos , Comprimidos/classificação , Anti-Inflamatórios/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA