Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1442902

RESUMO

Objective: This study aims to compare the strain induced in the supporting structures of unilateral mandibular removable partial denture frameworks retained by extra-coronal attachments fabricated with three different materials. Material and Methods: Three mandibular class II digitally designed and printed acrylic models with detachable abutments were used to fabricate three removable partial denture framework with extra coronal attachments from three different materials. A total of 33 models were prepared for strain testing (n=11). Models were divided into three groups according to framework's material: porcelain fused to cobalt chromium (PFM), polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) group. Unilateral load of 60 N was applied in the three groups and strains were measured around the main abutment and saddle area using strain gauge. Results: Statistical analysis was performed using Shapiro-Wilk's test and by checking data distribution. Data were found to be non-parametric and were analysed using Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. PFM group showed significantly the highest strain values around abutment, slot 1 (1mm distal to the socket of the last abutment) and slot 2 (1 cm away from slot 1) respectively (843.00±23.08, 91.00±6.52 and 1274.00±65.71) than the other tested groups (p<0.05) at same tested sites respectively followed by PEKK group (384.00±37.48, 81.00±2.24 and 135.00±0.00) and PEEK group (29.00±4.18, 63.00±4.47 and 52.00±5.70). Conclusions: PEEK and PEKK for partial denture framework with extra coronal attachments are adequate alternative to PFM due to their good mechanical response applying less strain on supportive structures in free-end cases. PEEK induces lower strain magnitude on the supporting structures when compared to PEKK. (AU)


Objetivo: Este estudo tem como objetivo comparar a tensão induzida nas estruturas de suporte de estruturas de próteses parciais removíveis mandibulares unilateraisretidas por encaixes extracoronários fabricados com três materiais diferentes. Material e Métodos: Três modelos mandibulares de classe II digitalmente projetados e impressos em acrílico com pilares destacáveis foram usados para fabricar três estruturas de próteses parciais removíveis com encaixes extracoronários de três materiais diferentes. Um total de 33 modelos foram preparados para testes de deformação (n=11). Os modelos foram divididos em três grupos de acordo com o material da estrutura: porcelana fundida com cobalto-cromo (PFM), poliétercetonacetona (PEKK) e polieteretercetona (PEEK). Carga unilateral de 60 N foi aplicada nos três grupos e as deformações foram medidas em torno do pilar principal e área de sela usando medido de tensão. Resultados: A análise estatística foi realizada por meio do teste de Shapiro-Wilk e com a verificação da distribuição dos dados. Os dados mostraram-se não paramétricos e foram analisados pelo teste de Kruskal-Wallis seguido pelo de Dunn com correção de Bonferroni. O grupo PFM mostrou significativamente os maiores valores de tensão ao redor do pilar, slot 1 (1mm distal do último pilar) e slot 2 (1 cm de distância do slot 1) respectivamente (843,00±23,08, 91,00±6,52 e 1274,00±65,71) do que os outros grupos testados (p<0,05) nos mesmos locais testados, respectivamente, seguido pelo grupo PEKK (384,00±37,48, 81,00±2,24 e 135,00±0,00) e grupo PEEK (29,00±4,18, 63,00±4,47 e 52,00±5,70). Conclusão: PEEK e PEKK para estrutura de prótese parcial com encaixes extracoronários são alternativas adequadas ao PFM devido à sua boa resposta mecânica aplicando menos tensão nas estruturas de suporte em casos de extremidade livre. O PEEK induz menor magnitude de deformação nas estruturas de suporte quando comparado ao PEKK (AU)


Assuntos
Prótese Parcial , Prótese Parcial Removível , Encaixe de Precisão de Dentadura
2.
Rev. inf. cient ; 101(2)abr. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1409523

RESUMO

RESUMEN Introducción: El Camphenol Plus es un derivado clorofenólico empleado como medicación intraconducto durante los tratamientos pulporradiculares en Estomatología. Son escasos los reportes científicos sobre el papel de los canales de iones potasio en la dinámica contráctil del músculo liso arterial inducida por dicho medicamento. Objetivo: Determinar el papel de los canales de iones potasio en la dinámica contráctil del músculo liso arterial inducida por Camphenol Plus. Método: Se realizó una investigación experimental preclínica en el Instituto de Fisiología "Oscar Langerdorff", Facultad de Medicina, Universidad de Rostock, Alemania, entre octubre y diciembre de 2018, con el empleo de 30 anillos de aorta obtenidos de 10 ratas Wistar (n=10). Las preparaciones biológicas se colocaron en baño de órganos y se preactivaron con solución Krebs concentrada en iones potasio, registrándose luego la tensión desarrollada por el músculo liso vascular tras la adición de soluciones de Camphenol Plus durante diferentes intervalos de tiempo. Se utilizaron las pruebas de Wilcoxon y U de Mann-Whitney. Resultados: El 31,4 % de la musculatura lisa vascular se relajó por acción del Camphenol Plus tras la preactivación con solución Krebs concentrada en iones potasio. El mayor descenso del tono vascular se produjo con el uso de soluciones del medicamento al 7 % entre el primer y tercer minutos. Conclusiones : El efecto vasorrelajante in vitro producido por Camphenol Plus sobre el músculo liso arterial está mediado por canales de iones potasio sensibles a voltaje, a calcio y a trifosfato de adenosina del endotelio vascular y el sarcolema.


ABSTRACT Introduction: Camphenol Plus is a chlorophenolic derivative commonly used as an intra - duct medication for pulporadicular treatments in Dentistry. Scientific reports about the use of this medication on the role of potassium ion channels in the contractile dynamics of induced arterial smooth muscle are low. Objective: To determine the role of potassium ion channels in the contractile dynamics of Camphenol Plus - induced arterial smooth muscle. Method: A preclinical experimental investigation was performed at the "Oscar Langerdorff" Institute of Physiology, Rostock University Medical Center, Rostock, Germany, between October and December 2018. A total of 30 aortic rings obtained from 10 Wistar rats (n=10) were used. The biological preparations were placed in an organ bath and preactivated with Krebs solution concentrated in potassium ions, afterwards it was recorded the tension developed by the vascular smooth muscle after applying the Camphenol Plus solutions in different time intervals. The Mann-Whitney U test and Wilcoxon test were applied. Results: The 31.4% of vascular smooth muscle was relaxed by the effect of Camphenol Plus after preactivation with Krebs solution concentrated in potassium ions. The greatest decrease in vascular tone occurred between the first and third minutes after the use of the drug solutions prepared at 7 %. Conclusions: The in vitro vasorelaxant effect produced by the Camphenol Plus medication on arterial smooth muscle is mediated by the potassium ion channels sensitive to voltage, calcium and the adenosine triphosphate of the vascular endothelium and sarcolemma.


RESUMO Introdução: Camphenol Plus é um derivado clorofenólico utilizado como medicação intracanal durante tratamentos pulporradiculares em Estomatologia. Existem poucos relatos científicos sobre o papel dos canais iônicos de potássio na dinâmica contrátil do músculo liso arterial induzida pela referida droga. Objetivo: Determinar o papel dos canais iônicos de potássio na dinâmica contrátil do músculo liso arterial induzida por Camphenol Plus. Método: Uma investigação experimental pré-clínica foi realizada no Instituto de Fisiologia "Oscar Langerdorff" da Faculdade de Medicina da Universidade de Rostock, Alemanha, entre outubro e dezembro de 2018, utilizando 30 anéis aórticos obtidos de 10 ratos Wistar (n=10). As preparações biológicas foram colocadas em banho de órgãos e pré-ativadas com solução de Krebs concentrada em íons potássio, registrando-se então a tensão desenvolvida pelo músculo liso vascular após a adição de soluções de Camphenol Plus em diferentes intervalos de tempo. Foram utilizados os testes U de Wilcoxon e Mann-Whitney. Resultados: 31,4% da musculatura lisa vascular relaxada pela ação do Camphenol Plus após pré-ativação com solução de Krebs concentrada em íons potássio. A maior diminuição do tônus vascular ocorreu com o uso de soluções medicamentosas a 7% entre o primeiro e o terceiro minutos. Conclusões: O efeito vasorrelaxante in vitro produzido pelo Camphenol Plus no músculo liso arterial é mediado por canais de íons de potássio sensíveis à voltagem, trifosfato de cálcio e adenosina do endotélio vascular e do sarcolema.

3.
Braz. dent. sci ; 25(3): 1-8, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1378428

RESUMO

Objective: The objective of this study was to evaluate the stress distribution in bone-surrounding implants placed in different levels in a mandibular overdenture. Material and Methods: A Computerized Tomography (CT) scan of an edentulous mandible was used to generate the models. Two implants with an internal connection were placed perpendicular to the occlusal plane in the Canine sites of the mandible. The implant in the left side was placed 1mm higher than the other side. Dolder bar and ball attachments were designed. Loading was performed by clenching the teeth with reconstruction of the muscles. In the anterior loading condition, force was applied to the central incisors and in the posterior loading conditions, it was applied to the molars and premolars. Then the Maximum Principal Stresses in the peri implant bone was evaluated with finite element analysis. Results:In both models, the highest stress values were recorded in the cortical bone surrounding the higher implant except in the ball model with unilateral load application on the right side (64.7 MPa). In almost all loading conditions the stress value differences in models with bar and ball attachments were low. Only in the anterior loading condition, the stress magnitude was higher in two implants of the ball model (60.5 MPa in the left side and 21 MPa in the right side) compared to the bar model (54.5 MPa in the left side and 17.5 MPa in the right side). Conclusion: The stress concentration did not affected considerably by the attachment system. High stress values were found adjacent the implant with a higher level. To reduce the amount of stress, bilateral balance occlusion should be considered. (AU)


Objetivo: O objetivo deste estudo foi avaliar a distribuição de tensões em tecido ósseo ao redor de implantes instalados em diferentes níveis em uma Overdenture mandibular. Material e Métodos: Uma tomografia computadorizada (TC) de uma mandíbula edêntula foi usada para gerar os modelos. Dois implantes de conexão interna foram instalados perpendicularmente ao plano oclusal na região de caninos inferiores. O implante do lado esquerdo foi instalado 1mm acima do que do lado direito. A barra Dolder e o pilar tipo bola foram projetados. A carga foi realizada apertando os dentes com reconstrução dos músculos. Na condição de carga anterior, a força foi aplicada nos incisivos centrais e nas condições de carga posterior, foi aplicada nos molares e pré-molares. Em seguida, as Tensões Máximas Principais no osso periimplantar foram avaliadas com análise de elementos finitos. Resultados: Em ambos os modelos, os maiores valores de tensão foram registrados ao redor do osso cortical ao redor do implante superior, exceto no modelo tipo bola com aplicação de carga unilateral no lado direito (64,7 MPa). Em quase todas as condições de carregamento, as diferenças nos valores de tensão nos modelos com fixações de barra e tipo bola foram baixas. Apenas na condição de carregamento anterior, a magnitude da tensão foi maior em dois implantes do modelo tipo bola (60,5 MPa no lado esquerdo e 21 MPa no lado direito) em relação ao modelo barra (54,5 MPa no lado esquerdo e 17,5 MPa no lado direito). Conclusão:A concentração de tensão não foi afetada considerando o sistema de retenção. Maiores valores de tensão foram encontrados adjacentes ao implante com um nível mais alto. Para reduzir a quantidade de tensão, a oclusão bilateral balanceada deve ser considerada.(AU)


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Análise do Estresse Dentário , Revestimento de Dentadura
4.
Dental press j. orthod. (Impr.) ; 27(4): e2120492, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1404486

RESUMO

ABSTRACT Objective: To analyze and compare the Von Mises stress and principal stress distribution in palatal bone around the palatal implant in lingual orthodontics (LiO) for single and double palatal implant systems with varying lengths of lever arm. Methods: Two groups were assessed: single (Group 1) and double (Group 2) palatal implant systems, which were further divided into two subgroups, based on lever arm length, for analyzing stress in the palatal bone around the implant. Hence, two 3D finite element models of bilateral maxillary first premolar extraction cases were constructed in each system. Lingual brackets (0.018-in slot) were positioned at the center of the clinical crown. In both systems, 150g of retraction force was applied, and ANSYS v. 12.1 software was used to analyze and compare stress in the palatal bone around the palatal implant. Results: In this study, higher stress was observed at the inner threaded interface of cortical bone. Magnitude of Von Mises stress was higher in Group 2 (0.63 MPa and 0.65 MPa) in comparison to Group 1 (0.29 MPa and 0.29 MPa). Similarly, magnitude of principal stress was higher in Group 2, in comparison to Group 1. Higher stress was observed in the apical region of the implant-bone interface of cancellous bone. Conclusion: This study concluded that the Von Misses stress as well as principal stress in the palatal bone were within the optimal limit in both groups. Finally, it can be concluded that both systems (single and double palatal implant) were safe for the patients in clinical use of 150g of retraction force.


RESUMO Objetivo: Analisar e comparar as tensões de Von Mises e a distribuição das tensões principais no osso palatino ao redor de implantes palatinos em Ortodontia Lingual (OL) para sistemas de implantes palatinos unitários ou duplos com comprimentos variados do braço de alavanca. Métodos: Foram delineados dois grupos para o presente estudo: Grupo 1 - com sistema de implante palatino unitário e Grupo 2 - com sistema de implantes palatinos duplos. Em seguida, os grupos foram divididos em dois subgrupos, com base no comprimento do braço de alavanca, para analisar as tensões no osso palatino ao redor do implante. Para cada sistema, foram construídos dois modelos 3D de elementos finitos (MEF) de casos com extração bilateral de primeiros pré-molares superiores. Braquetes linguais (slot 0,018") foram posicionados no centro das coroas clínicas. Nos dois sistemas, foram aplicados 150g de força de retração nos dentes anteriores, e o software ANSYS v. 12.1 foi usado para analisar e comparar as tensões no osso palatino ao redor dos implantes. Resultados: Foram observados maiores níveis de tensões na parte interna rosqueada no osso cortical. A magnitude das tensões de Von Mises foi maior no Grupo 2 (0,63MPa e 0,65MPa) em comparação ao Grupo 1 (0,29MPa e 0,29MPa). De forma semelhante, foi observada maior magnitude das tensões principais no Grupo 2 do que no Grupo 1. Maiores tensões foram observadas na região apical da interface osso/implante no tecido ósseo esponjoso. Conclusão: A tensões de Von Mises e as tensões principais no osso palatino ficaram dentro do limite ideal em ambos os grupos. Ambos os sistemas de implantes palatinos (unitário e duplo) foram seguros para o uso clínico em pacientes com força de retração de 150g.

5.
Cad. saúde colet., (Rio J.) ; 29(4): 575-584, out.-dez. 2021. tab
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1360331

RESUMO

Resumo Introdução Síndrome de burnout (SB) é um distúrbio emocional caracterizado por extremo esgotamento físico e mental decorrente de situações laborais estressantes. Já depressão é uma alteração afetiva decorrente de experiências pessoais negativas, sem referência a contextos específicos. Objetivo Analisar possível associação entre burnout e tensão emocional e depressão em profissionais de enfermagem de um hospital em Campina Grande, Paraíba. Método O delineamento foi quantitativo-correlacional, sendo "tensão emocional e depressão" a variável dependente e os fatores de burnout ("exaustão emocional" - EE; "cinismo" - CI; "ineficácia no trabalho" - IT) variáveis independentes, não pressupondo relações de causalidade. Participaram 220 sujeitos. Foram aplicados os instrumentos MBI (HSS), QSG-12 e Ficha Sociodemográfica. Foram efetuadas análises descritivas, de correlação (Spearman) e de regressão. Resultados Da amostra, 15% apresentaram elevada EE, 8,6%, moderada tensão, e 3,2%, depressão. Foi observada predição compartilhada entre os três fatores da SB com a "tensão emocional e depressão", sendo EE o mais forte preditor, explicando 17% da variância. Conclusão Os dados oferecem forte sugestão de que elevados níveis de EE influenciam a depressão, sendo imprescindível enfrentá-los e oferecer suporte psicológico, educativo e material para a recomposição da energia física e mental sugada pela sobrecarga laboral.


Abstract Background Burnout Syndrome (BS) is an emotional disorder characterized by extreme physical and mental exhaustion resulting from stressful work situations; depression is an affective alteration resulting from negative personal experiences, without reference to specific contexts. Objective to analyze a possible association between burnout and emotional tension and depression in nursing professionals at a hospital in Campina Grande - PB. Method The design was quantitative-correlational, with Emotional Tension and Depression as the dependent variable and the burnout factors (Emotional Exhaustion - EE, Cynicism - CI, Ineffectiveness at Work - IT) independent variables, not assuming causal relationships. The participants were 220 individuals The instruments MBI (HSS), QSG-12, and Sociodemographic Record were applied. Descriptive, correlation (Spearman), and regression analyzes were performed. Results 15% of the sample shows high EE, 8.6% moderate tension, and 3.2% depression. There was a shared prediction between the three factors of BS with Emotional Tension and Depression, with EE being the strongest predictor, explaining 17% of the variance. Conclusion The data offer a strong suggestion that high levels of EE influence depression, and it is essential to face them by offering psychological, educational, and material support to restore the physical and mental energy caused by work overload.

6.
Arq. bras. oftalmol ; 84(2): 158-162, Mar,-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1153111

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the appropriate timing of capsular tension ring implantation in cases of zonular weakness due to pseudoexfoliation syndrome. Methods: This prospective, comparative study was performed at the Ophthalmology Department of Inonu University, Malatya, Turkey. There were 43 patients included in the study. Group 1 (16 patients) had early capsular tension ring implantation, and group 2 (27 patients) had late capsular tension ring implantation. Patients with pseudoexfoliation syndrome who underwent phacoemulsification surgery, posterior chamber intraocular lens implantation, and capsular tension ring implantation were included in the study. Intraoperative complications and difficulties with either capsular tension ring implantation or cortex removal were evaluated in each eye. Results: There was no significant difference between the groups in the difficulty of capsular tension ring implantation (p=0.124). The difficulty of cortex removal differed significantly between the groups (p=0.003). Intraoperative complications were observed in 3 patients in group 1 and 11 patients in group 2; the difference between the groups was not significant (p=0.18). Posterior capsule fluctuations were observed in 8 patients (29.5%) in group 2, which resulted in posterior capsule rupture in 2 patients. Conclusions: Cortex removal is more difficult with early capsular tension ring implantation, and posterior capsule fluctuations may cause problems with late capsular tension ring implantation. The surgeon must consider the risk-to-benefit ratio of early versus late insertion for the optimal timing of capsular tension ring implantation.


RESUMO Objetivo: Avaliar o momento apropriado para implante de anel de tensão capsular em casos de fraqueza zonular devida à síndrome pseudoesfoliativa. Métodos: Este foi um estudo prospectivo e comparativo realizado no Departamento de Oftalmologia da Universidade İnönü. Foram incluídos 43 pacientes, sendo 16 no grupo 1 e 27 no grupo 2. O grupo 1 era composto de pacientes que se submeteram ao implante precoce do anel de tensão capsular, enquanto no grupo 2 os pacientes tiveram implante tardio. Foram incluídos pacientes com síndrome pseudoesfoliativa submetidos à cirurgia de facoemulsificação e ao implante de lente intraocular na câmara posterior e anel de tensão capsular. Em cada olho, foram avaliadas as complicações intraoperatórias e as dificuldades tanto com a implantação do anel de tensão capsular quanto com a remoção do córtex. Resultados: Não houve diferença significativa entre os grupos quanto à dificuldade de implante do anel de tensão capsular (p=0,124). Ao se comparar as remoções do córtex, observou-se diferença significativa entre os grupos (p=0,003). Complicações intraoperatórias foram observadas em 3 pacientes do grupo 1 e 11 pacientes do grupo 2; porém, não houve diferença significativa entre os grupos (p=0,18). No grupo 2, observaram-se flutuações da cápsula posterior em 8 pacientes (29,5%), com ruptura da cápsula posterior em dois deles. Conclusões: A remoção do córtex é mais difícil no implante precoce do anel de tensão capsular e flutuações da cápsula posterior podem causar problemas no implante tardio do anel de tensão capsular. O cirurgião deve ponderar a relação risco/benefício do implante precoce e tardio ao avaliar o momento ideal para implante de anel de tensão capsular.


Assuntos
Humanos , Extração de Catarata/reabilitação , Facoemulsificação/instrumentação , Análise Custo-Eficiência , Estudos Prospectivos
7.
Rev. méd. Paraná ; 79(Supl): 44-46, 2021.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1372802

RESUMO

A síndrome pré-menstrual se caracteriza pelo conjunto de sinais e sintomas que ocorrem na fase lútea tardia do ciclo menstrual, cessando no primeiro dia do ciclo, em que ocorre o fluxo menstrual. Os objetivos deste estudo foram entender quais os sintomas e sinais mais prevalentes durante o período lúteo de seu ciclo menstrual. O presente estudo teve caráter descritivo, tendo sido feita análise de prevalência em 143 mulheres entre 18 e 40 anos. O instrumento de coleta foi o questionário disponibilizado pelo American College of Obstetricians and Gynecologists (ACOG) e respondido de maneira anônima e consensual pelas participantes. Também foi aplicado um questionário com perguntas elaboradas pelos próprios autores deste estudo para melhor identificar seus perfis, como idade, período atual da faculdade, paridade (histórico de gestações), presença de comorbidades e uso de método contraceptivo (especificando qual). Em conclusão, a síndrome prémenstrual, além ser queixa comum em idade reprodutiva, é de importante avaliação multidisciplinar para que se diferenciem os sintomas de quadros psiquiátricos primários. O uso de métodos contraceptivos hormonais pode ser vantajoso na queixa de mastalgia durante o período lúteo.


Premenstrual syndrome is characterized by the set of signs and symptoms that occur in the late luteal phase of the menstrual cycle, ending on the first day of the cycle, when menstrual flow occurs. The objectives of this study were to understand the most prevalent symptoms and signs during the luteal period of menstrual cycle. It was descriptive in nature, with an analysis of prevalence in 143 women aged between 18 and 40 years. The data collection instrument was the questionnaire provided by the American College of Obstetricians and Gynecologists (ACOG) and answered anonymously and consensually by the participants. A questionnaire was also applied with questions prepared by the authors of this study to better identify their profiles, such as age, current period at college, parity (history of pregnancies), presence of comorbidities and use of contraceptive methods (specifying which one). In conclusion, premenstrual syndrome, in addition to being a common complaint in reproductive age, is an important multidisciplinary assessment to differentiate symptoms from primary psychiatric conditions. The use of hormonal contraceptive methods can be advantageous in complaints of breast tenderness during the luteal period.

8.
Rev. bras. ciênc. esporte ; 43: e007420, 2021. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1251123

RESUMO

ABSTRACT The study aimed to investigate the prevalence and effects of premenstrual syndrome (PMS) on the psychological factors of university students who do and do not participate in resistance training. The initial sample consisted of 81 participants, and the prevalence of PMS was 64.2%. Forty women diagnosed with PMS were divided into two groups: women who participated in (GP) and did not participate in (GNP) resistance training. The intergroup comparison showed significant differences (with higher scores in the GNP) in the items: difficulty concentrating, lack of energy, and feeling under pressure, and they reported a greater influence of the symptoms on their family relationships. It is concluded that women who participate in resistance training have reduced indicators of some psychological symptoms of PMS.


RESUMO O estudo objetivou investigar a prevalência e os efeitos da Síndrome Pré-Menstrual (SPM) nos fatores psicológicos de universitárias praticantes e não praticantes de treinamento resistido. A amostra inicial consistiu em 81 participantes, e a prevalência da SPM foi de 64,2%. Quarenta mulheres diagnosticadas com SPM foram divididas em dois grupos: praticantes (GP) e não-praticantes (GNP) de treinamento resistido. A comparação intergrupos apresentou diferenças significativas (com maiores escores do GNP) referentes aos itens: dificuldade de concentração, falta de energia, e sentindo-se sob pressão, tendo maior interferência dos sintomas em seus relacionamentos familiares. Conclui-se que mulheres praticantes de treinamento resistido apresentam indicadores reduzidos de alguns sintomas psicológicos da SPM.


RESUMEN El objetivo fue investigar la prevalencia y los efectos del síndrome premenstrual (SPM) sobre los factores psicológicos de las universitarias que practican y no practican el entrenamiento de resistencia. La muestra inicial consistió en 81 mujeres, y la prevalencia del SPM fue del 64,2%. Cuarenta mujeres diagnosticadas con SPM se dividieron en dos grupos: practicantes (GP) y no practicantes (GNP) de entrenamiento de resistencia. La comparación intergrupal mostró diferencias significativas (con puntajes de GNP más altos) con respecto a: dificultad para concentrarse, falta de energía y sentirse bajo presión, con una mayor interferencia de síntomas en sus relaciones familiares. Las mujeres que practican el entrenamiento de resistencia han reducido los indicadores de algunos síntomas psicológicos del SPM.

9.
Rev inf cient ; 100(5): 1-11, 2021. ilus
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1348797

RESUMO

Introducción: El p-clorofenol alcanforado es un derivado clorofenólico de uso común como medicación intraconducto en Endodoncia. Son escasos los reportes científicos sobre sus efectos en la musculatura lisa vascular arterial y la regulación del flujo sanguíneo local. Objetivo: Determinar el efecto del p-clorofenol alcanforado sobre la dinámica contráctil del músculo liso vascular arterial en el tiempo. Método: Se realizó una investigación experimental preclínica utilizando 14 anillos de aorta obtenidos de ratas Wistar. Los anillos se colocaron en baño de órganos y se preactivaron con noradrenalina, registrándose luego la tensión desarrollada por el músculo liso vascular tras la adición de p-clorofenol alcanforado durante diferentes intervalos de tiempo. Resultados: El 51,4 porciento de la musculatura lisa vascular se relajó por la acción del p-clorofenol alcanforado. El mayor descenso del tono vascular se produjo entre el tercer y quinto minuto de añadido el medicamento. Las pruebas de Wilcoxon de los rangos con signos evidenciaron diferencias significativas entre la tensión base inicial y la registrada en los diferentes intervalos de tiempo estudiados. Conclusiones: el p-clorofenol alcanforado, induce in vitro, relajación del músculo liso arterial a través de un acoplamiento excitación-contracción de tipo farmacomecánico, la cual se incrementa en función del tiempo(AU).


Introduction: Camphorated p-chlorophenol is a chlorophenolic derivative commonly used as an intra-oral medication in endodontics. Scientific reports on its effects in arterial vascular smooth muscle and local blood flow regulation are scarce. Objective: To determine the effect of camphorated p-chlorophenol on the contractile dynamics of arterial vascular smooth muscle. Method: An experimental and preclinical research was conducted with the use of 14 aortic rings of Wistar rats. The rings were placed in an organ bath and preactivated with noradrenaline, and the tension developed by the vascular smooth muscle at different time intervals was recorded after induction of camphorated p-chlorophenol. Results: Most of the vascular smooth muscle (51.4 percent) relaxed with the use of camphorated p-chlorophenol. The greatest decrease in vascular tone occurred between the third and fifth minute after use the drug. Wilcoxon rank tests showed significant differences between tension observed at baseline and those recorded at the different time intervals studied. Conclusions: Camphorated p-chlorophenol, induces in vitro, relax the arterial smooth muscle through a pharmacomechanical excitation-contraction link, which increases according to the time(AU).


Introdução: O cânfora-clorofenol é um derivado clorofenólico comumente utilizado como medicamento intracanal em Endodontia. Relatórios científicos sobre seus efeitos no músculo liso vascular arterial e na regulação do fluxo sanguíneo local são escassos. Objetivo: Determinar o efeito da cânfora-clorofenol na dinâmica contrátil do músculo liso vascular arterial ao longo do tempo. Método: Foi realizada investigação experimental pré-clínica com 14 anéis aórticos obtidos de ratos Wistar. Os anéis foram colocados em banho de órgãos e pré-ativados com norepinefrina, em seguida, a tensão desenvolvida pela musculatura lisa vascular foi registrada após a adição de cânfora-clorofenol em diferentes intervalos de tempo. Resultados: 51,4 porcento dos músculos lisos vasculares estavam relaxados pela ação do cânfora-clorofenol. A maior diminuição do tônus vascular ocorreu entre o terceiro e o quinto minuto após a adição do medicamento. Os testes de Wilcoxon das faixas com sinais mostraram diferenças significativas entre a tensão base inicial e a registrada nos diferentes intervalos de tempo estudados. Conclusões: O cânfora-clorofenol induz, in vitro, relaxamento da musculatura lisa arterial por meio de um acoplamento excitação-contração do tipo farmacomecânico, que aumenta em função do tempo(AU).


Assuntos
Animais , Ratos , Clorofenóis/administração & dosagem , Músculo Liso Vascular/efeitos dos fármacos , Tono Muscular/efeitos dos fármacos , Ratos Wistar , Alemanha
10.
Multimed (Granma) ; 24(6): 1283-1299, nov.-dic. 2020. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1143332

RESUMO

RESUMEN Introducción: los estilos de vida modernos y la modificación de los hábitos alimentarios han convertido al síndrome metabólico en un problema de salud pública. La incidencia de los trastornos metabólicos en la infancia y la adolescencia han experimentado un importante despunte que amerita mayor estudio y evaluación, y permite establecer estrategias de prevención y pesquisa, para así evitar o limitar el daño en la vida adulta. Objetivo: realizar la caracterización químico sanguíneo del síndrome metabólico en estudiantes del preuniversitario Micaela Riera Oquendo del municipio Manzanillo, provincia Granma en el año 2018. Métodos: se estudiaron 50 estudiantes del preuniversitario Micaela Riera Oquendo del municipio Manzanillo, provincia Granma en el año 2018, a partir de un estudio descriptivo prospectivo en el que evaluaron variables como: edad, sexo, exámenes complementarios, toma de la presión arterial, determinación del índice de masa corporal y los tipos de obesidad. Resultados: la mayor parte de las muestras de sangre tomadas dieron positivas a la hiperglicemia, existió un predominio de estudiantes con sobre peso, prevaleció el tipo de obesidad severa. Existieron 14 estudiantes obesos, 20 con hipertensión arterial y 30 con hiperglicemia, factor determinante del síndrome metabólico. Conclusión: existió un predominio de la hiperglicemia como factor determinante del síndrome metabólico.


ABSTRACT Introduction: the styles of modern life and the modification of the habits food, they have converted the syndrome metabolic in a problem of public health. The incident of the disorders metabolic in the childhood and the adolescence has experienced an important it blunt needing a bigger study and evaluation, allowing to establish strategies of prevention and investigation, for so avoid or limit the damage in the grown life. Objective: to make the characterization sanguine chemical of the syndrome metabolic in students of the Micaela Riera Oquendo preuniversity of the Manzanillo municipality, Granma county in the year 2018. Methods: 50 students were studied in the Micaela Riera Oquendo preuniversity of the Manzanillo municipality, Granma county in the year 2018, starting from a descriptive prospective study in the that they evaluated variables like: age, sex, complementary text, taking of the arterial pressure, determination of the IMC and the types of obesity. Results: most they of the patterns of taken blood gave positive to the hyperglycemia, students' prevalence existed with on peso, prevailed the type of severe obesity. They existed 14 obese students, 20 with HTA and 30 with hyper glycaemia, being this the factor decisive of the SM. Conclusion: a prevalence of the hyper glycaemia, like factor existed decisive of the SM.


RESUMO Introdução: estilos de vida modernos e mudanças nos hábitos alimentares tornaram a síndrome metabólica um problema de saúde pública. A incidência de distúrbios metabólicos na infância e na adolescência tem experimentado um aumento significativo que merece um estudo e avaliação mais aprofundados, e permite estabelecer estratégias de prevenção e pesquisa, a fim de evitar ou limitar os danos na vida adulta. Objetivo: realizar a caracterização química sanguínea da síndrome metabólica em alunos da pré-universidade Micaela Riera Oquendo do município de Manzanillo, província de Granma em 2018. Métodos: 50 alunos da pré-universidade Micaela Riera Oquendo, do município de Manzanillo, província de Granma, em 2018, foram estudados a partir de um estudo descritivo prospectivo no qual avaliaram variáveis como: idade, sexo, exames complementares, ingestão de pressão arterial, determinação do índice de massa corporal e tipos de obesidade. Resultados: a maioria das amostras de sangue colhidas deram positivo para hiperglicemia, houve predominância de estudantes com sobrepeso, prevaleceu o tipo de obesidade grave. Havia 14 estudantes obesos, 20 com pressão alta e 30 com hiperglicemia, determinante da síndrome metabólica. Conclusão: houve predomínio da hiperglicemia como fator determinante na síndrome metabólica.

11.
Biosci. j. (Online) ; 36(Supplement1): 238-248, Dec. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1355253

RESUMO

Synthetic auxin herbicides constitute major alternatives for managing tough-to-kill weeds such as Ipomoea spp. Adjuvant use is known to positively affect the biological efficacy of pesticides by modifying key spraying solution and droplet properties. Determining to what extent the use of adjuvants could change spray solution parameters and affect synthetic auxin herbicides' efficiency for Ipomoea spp. control were the research goals. The study was conducted in two phases: laboratory and field, respectively. In the laboratory, the pH, the surface tension, and the resources of the herbicide drops were measured. In the field, weed control was evaluated. All adjuvants modified spray solution properties, lowering surface tension values. Most adjuvants decreased pH values as well as number and density of droplets due to an increase in droplet size. Regardless of adjuvant usage, Ipomoea spp. control levels rose more rapidly following 2,4-D spraying rather than dicamba, resulting in lower biomass accumulation when the former was used. Dicamba-containing treatments displayed slightly but significantly lower Ipomoea spp. control levels at the end of the evaluation period. Herbicide efficacy for Ipomoea spp. control was not improved upon the addition to the spray solution of any of the tested adjuvants. Adjuvant use altered spraying solution and droplet properties. 2,4-D spraying allowed for lower Ipomoea spp. biomass and greater control levels relative to dicamba, suggesting it might constitute a better option for Ipomoea spp. control. Even though herbicide efficacy was not improved with adjuvants, their use should still be considered given favorable spraying solution alterations, mainly with some alteration in droplet sizes despite the use of similar spray nozzles tips - maintaining weed control efficacy.


Os herbicidas mimetizadores da auxina constituem alternativas importantes para o manejo de plantas daninhas de difícil controle, como Ipomoea spp. Sabe-se que o uso de adjuvante afeta positivamente a eficácia biológica dos pesticidas, modificando as principais propriedades da solução e do espectro de gotas da pulverização. Os objetivos desse trabalho foram determinar em que medida o uso de adjuvantes pode alterar os parâmetros da solução de pulverização e afetar a eficiência dos herbicidas mimetizadores da auxina para Ipomoea spp. Os estudos foram conduzidos em duas fases: em laboratório e em campo. Em laboratório foi avaliado o pH, tensão superficial e características das gotas dos herbicidas. Em campo foi avaliado o controle da planta daninha. Todos os adjuvantes modificaram as propriedades da solução de pulverização, diminuindo os valores de tensão superficial. A maioria dos adjuvantes diminuiu os valores de pH, bem como o número e a densidade de gotas. Independentemente do uso de adjuvante, os níveis de controle de Ipomoea spp. aumentaram mais rapidamente após a pulverização com 2,4-D do que com o dicamba, resultando em menor acúmulo de biomassa quando o primeiro foi usado. Os tratamentos contendo dicamba apresentaram ligeiramente menor controle de Ipomoea spp. A aplicação de 2,4-D promoveu menor biomassa e maiores níveis de controle em relação ao dicamba de Ipomoea spp., sugerindo que possa constituir uma opção melhor de controle. Embora a eficácia do herbicida não tenha sido melhorada com adjuvantes, seu uso ainda deve ser considerado com alterações favoráveis da solução de pulverização, principalmente tamanhos de gotas em qualquer uso de pontas de pulverização - mantendo a eficácia do controle de plantas daninhas.


Assuntos
Reguladores de Crescimento de Plantas , Convolvulus , Controle de Plantas Daninhas , Herbicidas
12.
Eng. sanit. ambient ; 24(6): 1209-1219, nov.-dez. 2019. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1056127

RESUMO

RESUMO Os biossurfactantes apresentam inúmeras aplicações ambientais e são produzidos por diversos microrganismos. Os provenientes da levedura Saccharomyces cerevisiae são pouco estudados para fins ambientais, sendo atóxicos. Objetivou-se o estudo da produção de biossurfactantes intra e extracelular por essa levedura, desenvolvida em meio de cultivo contendo 0,5% de extrato de levedura e 1% de peptona, além de concentrações variadas de sacarose e indutores oleosos - glicerol e óleos de soja e diesel. Os experimentos foram realizados durante 96 horas, e a produção de biossurfactantes foi avaliada diariamente, por meio da redução da tensão superficial e de estabilização de emulsões. O biossurfactante extracelular foi extraído da biomassa obtida, com posterior precipitação e caracterização química por intermédio de espectrometria de massa. As maiores produtividades de emulsificantes extracelulares foram obtidas com glicerol (0,20 UE.h-1) e óleo de soja (0,21 UE.h-1), em 48 horas de cultivo. Em ensaios posteriores, realizados com aumento da concentração de indutor, foi verificado um aumento das produtividades extracelulares para 0,45 UE.h-1 para o glicerol e 0,30 UE.h-1 para o óleo de soja. A maior redução da tensão superficial foi de 9,89%, em 72 horas, para o indutor óleo diesel. A diminuição dessa tensão, aliada ao aumento das atividades emulsificantes, é um importante indicativo da utilização do substrato hidrofóbico pelo microrganismo. O estudo comprova aumento na produção de biossurfactantes extracelulares quando realizada otimização de cultivo. Para a produção dos intracelulares, a necessidade de processo de rompimento celular aumenta os custos do bioprocesso.


ABSTRACT Biosurfactants implicate many environmental applications, being produced by a wide range of microorganisms. Those from the Saccharomyces cerevisiae yeast are still poorly studied for environmental purposes and are non-toxic. The aim of the study was the production of intra- and extracellular biosurfactants by the Saccharomyces cerevisiae yeast. The yeast was grown in cultured medium containing 0.5% yeast extract, 1% peptone and variable concentrations of sucrose and oily inducers. Inducers used were glycerol, soybean oil and diesel oil. Experiments were conducted for 96 h, and the daily production of biosurfactants was evaluated by reducing surface tension and stabilizing emulsions. Extracellular biosurfactant was extracted from the obtained biomass, with subsequent precipitation and chemical characterization by mass spectrometry. The highest extracellular emulsifier yields were achieved with glycerol inductor (0.20 UE h-1) and soybean oil (0.21 UE h-1) in 48h of cultivation. In later tests performed with increasing concentration of inducer, an increase in extracellular yields was noticed in these experiments (0.45 UE h-1 for glycerol and 0.30 UE h-1 for the soybean oil). The greatest reduction in surface tension was 9.89% in 72 h for diesel oil inducer. The reduction of surface tension combines with the increase of emulsifying activities in an important indicator of the use of hydrophobic substrate by the microorganism. The study confirms an increase in the production of extracellular biosurfactants when optimizing cultivation. The production of intracellular biosurfactants has also been verified, however the process of cellular disruption increases the cost of the bioprocess.

13.
Rev. bras. cir. plást ; 34(3): 331-335, jul.-sep. 2019. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-1047148

RESUMO

Introdução: Em 1988, Baroudi et al. publicaram um trabalho descrevendo a utilização de pontos de adesão entre o retalho dermoadiposo e a bainha anterior do músculo reto do abdome, no intuito de diminuir a formação de seroma. O presente estudo propõe-se a demonstrar uma provável correlação entre os pontos de adesão de Baroudi com a força tensional do retalho, através da medida da distância da cicatriz abdominal inferior ao xifoide antes e após os pontos de Baroudi, no transoperatório de dermolipectomia. Métodos: Trata-se de um estudo prospectivo observacional. Foram selecionadas submetidas a lipoabdominoplastia no Serviço de Cirurgia Plástica da Santa Casa de Misericórdia de Porto Alegre, no período de janeiro a abril de 2019. Aferiram-se as medidas transoperatórias da distância do apêndice xifoide esternal à cicatriz umbilical, e da primeira à cicatriz cirúrgica, pré e pós-realização dos pontos de adesão de Baroudi. A análise estatística foi realizada com o software Excel®. Resultados: Verificou-se a diminuição das distâncias apêndice xifoidecicatriz umbilical e apêndice xifoide-cicatriz após a realização da sutura de Baroudi (média de 1,5cm), pressupondo-se diminuição da tensão da cicatriz. Conclusão: As medidas aferidas no presente estudo mostraram uma diminuição da distância xifoide-cicatriz umbilical e xifoide-cicatriz abdominal inferior após a realização dos pontos de Baroudi, evidenciando uma menor tensão na cicatriz. Sugere-se estudos para avaliar como essas medidas se comportam a longo prazo e se realmente se correlacionam a uma cicatriz de melhor qualidade.


Introduction: In 1988, Baroudi et al. published a paper describing the use of adhesion points between the dermoadipose flap and the anterior rectus abdominis sheath to reduce seroma formation. This study aimed to demonstrate a probable correlation between the use of Baroudi adhesion points and reduction in flap tension force by measuring the distance from the lower abdominal scar to the xiphoid before and after using Baroudi points in dermolipectomy transoperatory. Methods: This was a prospective observational study that selected patients who underwent lipoabdominoplasty at the Santa Casa de Misericórdia Plastic Surgery Service of Porto Alegre from January to April 2019. The transoperatory measurements of distance from the sternal xiphoid appendix to the umbilical scar and from the pre-xiphoid to the postxiphoid scar before and after execution of Baroudi's adhesion points were compared. Statistical analysis was performed using Excel® software. Results: A reduction in the distances between the xiphoid-umbilical scar appendix and xiphoidscar appendix was verified after execution of Baroudi suture (mean 1.5 cm), indicating a decrease in scar tension. Conclusion: There was a decrease in the xiphoid-umbilical scar and xiphoid-lower abdominal scar distance after Baroudi stitches, indicating lower scar-tissue tension. Further studies should be conducted to evaluate these measurements in the long term and their correlation with a better-quality scar.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , História do Século XXI , Pesos e Medidas , Interpretação Estatística de Dados , Estudos Prospectivos , Cicatriz , Pontos de Referência Anatômicos , Abdominoplastia , Pesos e Medidas/normas , Cicatriz/cirurgia , Cicatriz/complicações , Pontos de Referência Anatômicos/cirurgia , Pontos de Referência Anatômicos/lesões , Abdominoplastia/efeitos adversos , Abdominoplastia/métodos , /métodos
14.
Fisioter. Bras ; 20(3): 392-399, Junho 11, 2019.
Artigo em Português | LILACS | ID: biblio-1281324

RESUMO

Introdução: Na fase reprodutiva das mulheres surgem sintomas relacionados ao ciclo menstrual. A Tensão Pré-Menstrual (TPM) é a junção de perturbações que aparecem antes da menstruação mensal e que afetam bastante a vida da mulher. Objetivo: Quantificar a prevalência da TPM entre universitárias. Métodos: Estudo epidemiológico de corte transversal, realizado com 152 universitárias em agosto de 2017. Foram aplicados dois questionários: um para o conhecimento do perfil epidemiológico e o Menstrual Symptoms Questionnaire (MSQ) que é uma escala para avaliar os sintomas menstruais. Foi realizada uma análise estatística descritiva e analítica, e todas as conclusões foram realizadas com o p-valor de 0,05. Resultados: A prevalência da TPM na amostra foi de 87,5%. 94,1% das mulheres encontravam-se na faixa etária de 18 a 26 anos. Ao analisar a história reprodutiva não foi observada nenhuma associação com a TPM. Os sintomas mais prevalentes no estudo foram: estresse, tensão, dores, irritabilidade e mudanças de humor. Por fim, quando associamos o MSQ com a presença da TPM foi observada uma associação em todos os itens pesquisados. Conclusão: Com base nos resultados obtidos, observou-se uma alta prevalência da TPM entre universitárias. (AU)


Introduction: On reproductive phase of women appear symptoms related to menstrual cycle. Premenstrual tension (PMT) is the junction of disturbances that appear before the monthly menstruation and affecting the woman's life. Objective: To quantify the prevalence of PMS among university students. Methods: Cross-sectional epidemiological study, conducted with 152 students in August 2017. We applied two questionnaires: one for the knowledge of the epidemiological profile and the Menstrual Symptoms Questionnaire (MSQ), to assess the menstrual symptoms. A descriptive statistical analysis and analytical was conducted, and all findings were carried out with p-value of 0.05. Results: The prevalence of PMT in the sample was 87.5%. 94.1% of the women were 18 to 26 years old. When analyzing the reproductive story was not observed any association with PMT. The most prevalent symptoms in the study were: stress, tension, pain, irritability and mood swings. Finally, when we combine the MSQ with the presence of PMS we observed an association in all items surveyed. Conclusion: Based on the results obtained, we observed a high prevalence of PMT among university students. (AU)


Assuntos
Humanos , Feminino , Adulto Jovem , Estudantes , Síndrome Pré-Menstrual , Estudos Epidemiológicos , Prevalência , Menstruação
15.
Eng. sanit. ambient ; 23(5): 913-922, set.-out. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-975147

RESUMO

RESUMO Neste artigo foi proposto um modelo matemático simplificado para inferir sobre a capacidade erosiva de um escoamento lamoso em regime laminar com presença de roll waves (efeito pulsante) na superfície livre. Na perspectiva de aplicação de resultados no contexto de desastres naturais (corridas de lama), foi determinada a evolução da velocidade média e da tensão de cisalhamento no fundo do canal. O modelo proposto é baseado nas equações de águas rasas e na reologia de Herschel-Bulkley, como representativa das lamas. A validação e a aplicação do modelo foram feitas a partir de dados experimentais de roll waves geradas em canal no laboratório confrontados com resultados de simulações numéricas. Os resultados obtidos mostram um incremento na capacidade erosiva, na presença de roll waves, da ordem de 12% em relação ao escoamento base, valor este em concordância com os 10% apontados por Ng e Mei (1994) para uma reologia mais simplificada.


ABSTRACT In this paper, we proposed and validated a simplified mathematical model to estimate the erosive capacity of a muddy laminar flow with roll waves (pulsating effect) on the free surface. From the perspective of applying results in the context of natural disasters (mudflows), the evolution of mean velocity and bottom shear stress in the channel were determined. The proposed model is based on shallow water equations and Herschel-Bulkley rheology as representative of the muds. The model was validated by comparison with results of numerical simulations and experimental data of roll waves generated in a channel. In-depth comparative analyses were made for inferring the erosive capacity of this sort of flow. The obtained results show an increase of erosive capacity (12%) due to the presence of roll waves in relation to the uniform flow's. Similar values (10%) were found by Ng and Mei (1994) for a more simplified rheology model.

16.
Cienc. act. fís. (Talca, En línea) ; 19(2): 1-11, jul. 2018. tab
Artigo em Português | LILACS | ID: biblio-994795

RESUMO

Objetivo: analizar las repeticiones máximas (RM) y el tiempo de tensión (TST) entre los órdenes multiarticular para monoarticular y monoarticular para multiarticular en ejercicios resistidos. Métodos: 15 hombres entrenados (23,53±2,07 años; 74,8±5,1 kg; 173,8±4,6 cm) realizaron la prueba de 10RM en los ejercicios supino horizontal (SH) y rosca tríceps en el pulley (RT). Después de 48 horas realizaron repeticiones máximas para los mismos ejercicios en diferentes órdenes multiarticular-monoarticular y monoarticular-multiarticular. En los dos protocolos propuestos, el número máximo de repeticiones y el tiempo de tensión (TST) se contabilizaron sólo en el último ejercicio realizado. Resultado: La prueba T de Student pareado apuntó reducciones significativas en el número de RM en los dos protocolos analizados cuando comparados a la prueba de 10RM (p <0,005 y p <0,001). Los resultados mostraron no haber diferencias significativas en el TST en ninguna de las condiciones evaluadas. Conclusión: el orden de los ejercicios influenció el número de repeticiones realizadas, aunque no afectó el TST.


Objetivo: analisar as repetições máximas (RM) e o tempo sob tensão (TST) entre as ordens multiarticular para monoarticular e monoarticular para multiarticular em exercícios resistidos. Métodos: quinze homens treinados (23,53±2,07anos; 74,8±5,1kg; 173,8±4,6cm) realizaram teste 10RM nos exercícios supino horizontal (SH) e rosca tríceps no pulley (RT). Após quarenta e oito horas realizaram repetições máximas para os mesmos exercícios nas diferentes ordens multiarticular-monoarticular e monoarticular-multiarticular. Nos dois protocolos propostos, o númeexercício realizado. Resultado: O Teste T de Student pareado apontou reduções significativas no número de RM nos dois protocolos analisados quando comparados ao teste de 10RM (p<0,005 e p<0,001). Os resultados mostraram ainda não haver diferenças significativas para o TST em nenhuma das condições avaliadas. Conclusão: A ordem dos exercícios influenciou o número de repetições realizadas, embora não tenha afetado o tempo sob tensão.


Objective: was to analyze maximal repetitions (MR) and time under tension (TUT) between multi-joint to single-joint order and single-joint to multi-joint order in resistance exercises. Methods: Fifteen trained men (23.53 ± 2.07 years, 74.8 ± 5.1 kg, 173.8 ± 4.6cm) performed a 10RM test in the Bench Press (BP) and Arm Extension (AE). After 48h performed maximal repetitions for the same exercises in different orders, single-joint and multi-joint. In both protocols were measured the maximal repetitions (MR) and time under tension (TUT) only for the last exercise realized. Results: The paired Student's T test showed significant reductions for MR in both analyzed protocols when compared to the 10RM test (p <0.005 and p <0.001). The results showed that there were no significant differences for TUT in any of the conditions evaluated. Conclusion: The order of the exercises influenced the number of repetitions performed, although it did not affect the time under tension.


Assuntos
Humanos , Masculino , Adulto , Treinamento Resistido/métodos , Articulações/fisiologia , Educação Física e Treinamento , Fatores de Tempo
17.
Univ. sci ; 23(1): 129-139, Jan.-Apr. 2018. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-963362

RESUMO

Abstract Humidity is one of the most important ambient factors influencing torque calibration readings. The present study addresses the effects of relative humidity on the readings of reference torque transduction and amplification devices. The results revealed a linear effect of increasing humidity on the readings of a DMP40 torque amplifier and a torque transducer at different temperatures. Furthermore, humidity effects were smaller on the DMP40 amplifier than on the torque transducer, even at different temperatures. The results also showed that the summed effect of humidity changes on torque calibration readings of the amplifier and the torque transducer, when assessed simultaneously, but with each device under different controlled humidity conditions, is greater than the observed effect on the readings when both devices were subjected to humidity changes together. Therefore, it is recommended to test the effect of humidity in setups where these two devices are both under common humidity conditions. This is likely to lower the uncertainty parameter of the obtained torque calibration readings and is a useful consideration for inter-laboratory comparisons and performance testing.


Resumen La humedad es uno de los factores ambientales que más influyen sobre las lecturas de calibración de mediciones de torque. En este trabajo se estudiaron los efectos de la variación de la humedad relativa sobre las lecturas de aparatos de referencia para transducción y amplificación de torque. Los resultados mostraron una relación lineal y positiva entre el aumento de la humedad relativa y el componente de error de las mediciones de referencia de un transductor y un amplificador de torque DMP40 bajo cuatro temperaturas distintas. Sin importar la temperatura, las mediciones del transductor de torque fueron más susceptibles de ser afectadas por la humidad relativa que las del amplificador DMP40. Se observó también que la suma de los efectos de la humedad relativa en las lecturas de referencia del amplificador y el transductor fueron mayores cuando ambos aparatos fueron operados bajo condiciones de humedad relativa y temperatura distintas (i.e. el amplificador se encontraba en una cámara climática controlada y el transductor fuera de ella, y viceversa) que cuando ambos aparatos fueron operados bajo las mismas condiciones ambientales (i.e. ambos dentro de la cámara climática controlada). En consecuencia, se recomienda llevar a cabo evaluaciones de la humedad en espacios donde ambos aparatos estén bajo las mismas condiciones de temperatura y humedad relativa. Esto puede reducir el componente de incertidumbre de lecturas de calibración de torque y es un factor a considerar al llevar a cabo comparaciones entre laboratorios y tests de desempeño en aplicaciones industriales.


Resumo A umidade é um dos fatores ambientais que mais influenciam as leituras de calibração de medições de torque. O presente estudo analisou os efeitos da umidade relativa sobre as leituras de equipamentos de referência para transdução e amplificação de torque. Os resultados mostraram um efeito linear do aumento da umidade relativa na medição de referência de um transdutor e um amplificador de torque DMP40 em quatro temperaturas diferentes. Adicionalmente, os efeitos da umidade foram menores no amplificador DMP40 do que no transdutor de torque em todas as quatro temperaturas. Os resultados também mostraram que a soma dos efeitos da umidade relativa nas leituras de referência do amplificador e do transdutor foram maiores quando ambos equipamentos foram operados em condições de umidade relativa e temperatura distintas (p.e. o amplificador se encontrava em uma câmara climática controlada e o transdutor fora da câmara, e vice-versa) do que quando ambos equipamentos eram operados nas mesmas condições ambientais (p.e. ambos dentro da câmara climática controlada). Assim sendo, se recomenda avaliar o efeito da umidade em espaços onde ambos equipamentos estejam expostos a mesmas condições de temperatura e umidade relativa. Esso pode reduzir o parâmetro de incerteza das leituras de calibração de torque e é um fator a ser considerado ao realizar comparações entre laboratórios e testes de desempenho em aplicações industriais.


Assuntos
Calibragem , Torque , Umidade
18.
Biosci. j. (Online) ; 34(2): 534-539, mar./apr. 2018. ilus, graf
Artigo em Inglês | LILACS | ID: biblio-966765

RESUMO

This study was to analyze the in vivo distribution of wall shear stress (WSS), velocity and inplane pressure difference in normal carotid artery by using computational fluid dynamics (CFD) based on contrastenhanced MRA (CE-MRA) data and to determine whether there were differences in these hemodynamic parameters between atherosclerosis-free and atherosclerosis-prone areas. CE-MRA was performed on 16 normal carotid arteries to obtain carotid three-dimensional surface data. CFD analysis was then performed to estimate those parameters in atherosclerosis-free (distal common carotid artery and distal internal carotid artery) and atherosclerosis-prone (carotid bifurcation) areas. One-way analysis of variance (ANOVA) was conducted to analyze differences among these three areas. CFD analysis revealed that WSS and velocity were significantly lower in carotid bifurcation compared to distal common carotid artery (CCA) (P =0.011, P <0.001, respectively) and distal internal carotid artery (ICA) (P <0.001, P <0.001, respectively). While in-plane pressure difference was significantly higher in carotid bifurcation compared to distal CCA (P <0.001) and distal ICA (P =0.005). Hemodynamic environment in carotid bifurcation of normal carotid artery which assessed by using CFD analysis appeared to be with lower WSS and lower velocity, while with higher in-plane pressure difference. These characterizations might facilitate the initiation of atherosclerosis.


Este estudo teve como objetivo analisar a distribuição in vivo da tensão de cisalhamento da parede (WSS), velocidade e plano diferença de pressão na artéria carótida normal usando dinâmica de fluidos computacional (CFD) baseada em contraste Dados do MRA (CE-MRA) e para determinar se houve diferenças nesses parâmetros hemodinâmicos entre áreas livres de aterosclerose e propensas à aterosclerose. O CE-MRA foi realizado em 16 artérias carótidas normais para obter dados de superfície tridimensional da carótida. A análise CFD foi então realizada para estimar esses parâmetros em livre de aterosclerose (artéria carótida comum distal e artéria carótida interna distal) e propensa a aterosclerose (carótida bifurcação). Análise de variância unidirecional (ANOVA) foi realizada para analisar as diferenças entre essas três áreas. A análise de CFD revelou que o WSS e a velocidade foram significativamente menores na bifurcação carotídea em comparação com a comum distal artéria carótida (ACC) (P = 0,011, P <0,001, respectivamente) e artéria carótida interna distal (ACI) (P <0,001, P <0,001, respectivamente). Enquanto a diferença de pressão no plano foi significativamente maior na bifurcação carotídea em comparação com a CCA distal (P <0,001) e ICA distal (P = 0,005). Ambiente hemodinâmico na bifurcação carotídea da artéria carótida normal que avaliada por meio de análise de CFD parece estar com menor WSS e menor velocidade, enquanto com maior pressão no plano diferença. Essas caracterizações podem facilitar o início da aterosclerose.


Assuntos
Doenças das Artérias Carótidas , Hemodinâmica , Angiografia , Artérias Carótidas , Biologia Computacional , Acidente Vascular Cerebral
19.
Aval. psicol ; 17(2): 180-187, 2018. il, tab
Artigo em Português | LILACS | ID: biblio-967699

RESUMO

Os estudos sobre variáveis exclusivamente femininas são raros na literatura nacional. O presente estudo teve como objetivo identificar evidências de validade da Escala de Síndrome Pré-menstrual (ESPm). O instrumento foi construído a partir de descrições de sintomas comumente relatados na literatura especializada e passou pelo crivo de juízes que avaliaram os itens e fatores propostos. Posteriormente, o instrumento foi aplicado em 391 trabalhadoras, por meio de um link disponibilizado virtualmente. Os indicadores de validade foram identificados, a partir da análise fatorial confirmatória, onde a melhor adequação foi apresentada por um modelo bifatorial, com menor qui-quadrado, menos graus de liberdade, além de um RMSEA de 0,04 e um CFI de 0,98. Os dois fatores que compõem a escala final (fator emocional e fator físico) contém ao todo 38 itens. (AU)


Studies on exclusively female variables are rare in national literature. The present study aimed at a preliminary validation of the Premenstrual Syndrome Scale (PmSS). The instrument was elaborated based on proposals from nursing and nutrition specialists and was reviewed by judges who evaluated the proposed items and factors. Subsequently, the instrument was applied to 391 workers through a virtual link. The validity indicators were identified from the confirmatory factor analysis, where the best fit was presented by a two-factor model, with a lower chi-square, fewer degrees of freedom, in addition to a RMSEA of 0.04 and an CFI of 0.98. The two factors that make up the final scale (emotional factor and physical factor) contain a total of 38 items. (AU)


Los estudios sobre variables exclusivamente femeninas, no son muy frecuentes em la literatura nacional. El presente estudio, tuvo como objetivo realizar una validación preliminar de la Escala de Síndrome Pre-menstrual (ESPm). El instrumento fue construído a partir de propuestas provenientes de la enfermería y nutrición y pasó por eltamiz de jueces que evaluaron los ítems y factores propuestos. Posteriormente, el instrumento fue aplicado a 391 trabajadoras, a través de um link disponibilizado virtualmente. Los indicadores de validez fueron identificados, a partir de análisis factorial confirmatorio, donde la mejor adecuación fue presentada por un modelo bifactorial, con menor qui-cuadrado, menos grados de libertad, además de un RMSEA de 0,04 y un CFI de 0,98. Los dos factores que componenla escala final (factor emocional y factor físico) contienenen total 38 ítems. (AU)


Assuntos
Humanos , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Síndrome Pré-Menstrual , Reprodutibilidade dos Testes , Análise Fatorial , Transtorno Disfórico Pré-Menstrual
20.
Ciênc. agrotec., (Impr.) ; 41(6): 713-723, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890662

RESUMO

ABSTRACT Fabricated food gels involving the use of hydrocolloids are gaining polpularity as confectionery/convenience foods. Starch is commonly combined with a hydrocolloid (protein our polyssacharides), particularly in the food industry, since native starches generally do not have ideal properties for the preparation of food products. Therefore the texture studies of starch-protein mixtures could provide a new approach in producing starch-based food products, being thus acritical attribute that needs to be carefully adjusted to the consumer liking. This work investigated the texture and rheological properties of mixed gels of different concentrations of rice starch (15%, 17.5%, and 20%) and whey protein isolate (0%, 3%, and 6%) with different crosshead velocities (0.05, 5.0, and 10.0 mm/s) using a Box-Behnken experimental design. The samples were submitted to uniaxial compression tests with 80% deformation in order to determinate the following rheological parameters: Young's modulus, fracture stress, fracture deformation, recoverable energy, and apparent biaxial elongational viscosity. Gels with a higher rice starch concentration that were submitted to higher test velocities were more rigid and resistant, while the whey protein isolate concentration had little influence on these properties. The gels showed a higher recoverable energy when the crosshead velocity ​​was higher, and the apparent biaxial elongational viscosity was also influenced by this factor. Therefore, mixed gels exhibit different properties depending on the rice starch concentration and crosshead velocity.


RESUMO Géis fabricados que envolvem o uso de hidrocolóides estão ganhando polpularidade como alimentos de confeitaria/conveniência. O amido é geralmente combinado com um hidrocolóide (proteínas ou polissacarideos), particularmente na indústria de alimentos, uma vez que os amidos nativos geralmente não têm propriedades ideais para a preparação de produtos alimentares. Por conseguinte, os estudos de textura de misturas de amido-proteína podem proporcionar uma nova abordagem na produção de produtos alimentares à base de amido, sendo assim um atributo acrítico que precisa ser cuidadosamente ajustado ao gosto do consumidor. Este trabalho investigou as propriedades reológicas de textura de géis mistos de diferentes concentrações de amido de arroz (15%, 17,5% e 20%) e isolado proteico de soro (0%, 3% e 6%) com diferentes velocidades de teste (0,05, 5,0 e 10,0 mm/s) utilizando um delineamento experimental por Box-Behnken. As amostras foram submetidas a testes de compressão uniaxial com deformação de 80% para determinar os seguintes parâmetros reológicos: módulo de Young, tensão de fratura, deformação da fratura, energia recuperável e aparente viscosidade elongacional biaxial. Géis com maior concentração de amido de arroz e que foram submetidos a velocidades de teste mais altas mostraram-se mais rígidos e resistentes, enquanto que a concentração de isoldado proteico de soro teve pouca influência nessas propriedades. Os géis mostraram uma energia recuperável mais alta quando a velocidade de teste foi maior, e a viscosidade elongacional biaxial aparente também foi influenciada por este fator, exibindo propriedades diferentes dependendo da concentração de amido de arroz e da velocidade de teste.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA