Braz. dent. sci ; 26(4): 1-11, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1523131

RESUMO

Objective: This study aimed to evaluate the efficacy and sustainability of using low level LASER therapy and CAD/CAM Michigan splint on improving the range of mandibular movements, muscle activity and reducing the pain. Material and Methods: 56 female patients were randomly divided into two groups. Group A: Patients received applications of low-level LASER therapy using semiconductor InGaAsp diode LASER type 940 nm with continuous mode of operation, applied for 180 sec per session for 12 sessions. Group B: Patients received Michigan splint of 2 mm thickness constructed on their upper teeth, the splint was 3D digitally printed. Electromyography was used to evaluate muscle activity, visual analogue scale was used to evaluate the pain intensity, ARCUS digma facebow was used to evaluate range of mandibular movements, and maximum mouth opening was taken using a millimeter ruler. They were measured before the beginning of the treatment, and at three and six month follow-up periods. Results: The results revealed that both low-level LASER therapy and Michigan splint reduce the myofascial pain, improved the range of the mandibular movements, and the muscles activity, but the effect of the low-level LASER therapy was more profound and sustainable. After 6 months from the beginning of the treatment, changes in masseter muscle activity (P= 0.001; effect size= 1.757), pain intensity (P= 0.003; effect size= 3), and range of mandibular movement (P= 0.001, effect size= 1.729) differed significantly between the two groups. Conclusions: Low-level LASER therapy had a better and more sustainable effect on reducing the pain intensity and improving the muscle activity as well as the mandibular movement when compared to Michigan splint (AU)


Objetivo: Este estudo teve como objetivo avaliar a eficácia e a durabilidade do uso da terapia LASER de baixa potência e da placa de Michigan CAD/CAM na melhora da amplitude dos movimentos mandibulares, atividade muscular e redução da dor. Material e Métodos: 56 pacientes do sexo feminino foram divididos aleatoriamente em dois grupos. Grupo A: os pacientes receberam aplicações de terapia LASER de baixa potência utilizando diodo semicondutor InGaAsp LASER tipo 940 nm em modo contínuo de operação, aplicado por 180 segundos por sessão durante 12 sessões. Grupo B: os pacientes receberam a placa de Michigan com uma espessura de 2 mm confeccionada sobre a arcada superior, a placa foi impressa digitalmente em 3D. A eletromiografia foi utilizada para avaliar a atividade muscular, a escala visual analógica foi utilizada para avaliar a intensidade da dor, o arco facial ARCUS digma foi utilizado para determinar a amplitude dos movimentos mandibulares e a abertura máxima da boca foi medida com uma régua milimétrica. Todas as medidas foram realizadas antes do início do tratamento e nos períodos de acompanhamento de três e seis meses. Resultados: Os resultados revelaram que tanto a terapia LASER de baixa potência como a placa de Michigan reduziram a dor miofascial, aumentaram a amplitude dos movimentos mandibulares e melhoraram a atividade muscular, mas o efeito da terapia LASER de baixa potência foi mais profundo e duradouro. Após 6 meses do início do tratamento, as alterações na atividade do músculo masseter (P= 0. 001; tamanho do efeito= 1,757), intensidade da dor (P= 0,003; tamanho do efeito= 3), e amplitude de movimento mandibular (P= 0,001, tamanho do efeito= 1,729) diferiram significativamente entre os dois grupos. Conclusão: A terapia com LASER de baixa potência teve um efeito melhor e mais duradouro na redução da intensidade da dor e na melhora da atividade muscular, bem como do movimento mandibular, quando comparada à placa de Michigan(AU)


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Dor Facial/radioterapia , Transtornos da Articulação Temporomandibular/radioterapia , Placas Oclusais , Terapia com Luz de Baixa Intensidade , Medição da Dor , Amplitude de Movimento Articular , Eletromiografia , Músculos da Mastigação/fisiopatologia
2.
Rio de Janeiro; s.n; 2015. 68 p. ilus, graf.
Tese em Português | LILACS | ID: lil-755448

RESUMO

O sucesso do tratamento endodôntico depende da cuidadosa realização de todas as suas fases, terminando com uma obturação tridimensional que alcance todo o sistema de canais radiculares. Desta forma, os materiais obturadores, ou as substâncias liberadas, entrarão em contato com os tecidos perirradiculares, o que poderá influenciar a resposta inflamatória e o processo de reparo. A terapia laser de baixa potência (TLBP) tem sido estudada quanto à sua ação anti-inflamatória, favorecendo o reparo. O objetivo deste estudo foi investigar a produção das citocinas IL-1β, IL-6 e IL-8 por fibroblastos de gengiva humana (linhagem FMM1) como resposta à presença dos extratos dos cimentos endodônticos AH Plus, MTA Fillapex e EndoSequence BC Sealer, bem como a eficácia da TLBP, neste modelo. Para isto, extratos destes cimentos, recém-manipulados e após 24 h do endurecimento, foram preparados em meio de cultura DMEM fresco, conforme as normas ISO 10993-12. Inicialmente, a citotoxicidade dos cimentos foi avaliada, após a interação das células com a diluição seriada destes extratos (1:1 a 1:16), por meio do ensaio MTT. Para a análise da produção de citocinas, 106 células por poço foram cultivadas em placas de cultura de 24 poços, para a interação com os extratos dos cimentos, na diluição 1:4. Estabeleceram-se os grupos não irradiado e irradiado. No grupo irradiado, as culturas celulares receberam duas irradiações do laser InGaAlP (660 nm, 30 mW, 5 J/cm2 e área do feixe de 0,028 cm2), com intervalo de 12 h. O grupo não irradiado foi submetido às mesmas condições ambientais que o irradiado. Os sobrenadantes das culturas foram coletados, centrifugados, aliquotados e armazenados congelados, para a posterior análise pelo ensaio de ELISA. Todos os dados obtidos (médias ± erro padrão) foram tratados estatisticamente por ANOVA one-way, complementado pelo teste de Tuckey e ANOVA...


Endodontic treatment success depends on careful accomplishment of all steps, finishing with a three-dimensional obturation that reachs the entire root canal system. Thus, the obturation materials or the substances that are released will be in contact with perirradicular tissues, which may influence the inflammatory response and the repair process. Low-level laser therapy (LLLT) has been studied about its anti-inflammatory action, improving the repair. The aim of this study was to investigate the production of IL-1β, IL-6 and IL-8 cytokines by human gingival fibroblasts (FMM1 lineage) as a response to the extracts of the endodontic cements AH Plus, MTA Fillapex and EndoSequence BC Sealer, besides the effectiveness of LLLT in this model. For that, freshly mixed and 24 h-set elutes of these sealers were prepared, in fresh DMEM, in accordance with ISO 10993-12. Firstly, cytotoxicity was assessed after cells were treated with cements extracts serial dilution (1:1 to 1:16), by MTT assay. To evaluate the cytokines production, 106 cells per well were cultured at 24-well-plates to interact with the 1:4 dilution of sealers extracts. Non-irradiated and irradiated groups were established. On the irradiated group, the cell culture received two InGaAlP laser irradiation (660 nm, 30 mW, 5 J/cm2, 0.028 cm2 spot size) at 12h-interval. The non-irradiated group was submitted to the same environment conditions of the irradiated group. The culture supernatants were collected, centrifuged, aliquoted and stored frozen to further analyse by ELISA assay. Data obtained (media ± standard error) were treated by ANOVA one-way, complemented by Tuckey’s test and ANOVA two-way, with Bonferroni correction (p< 0.05). The cytotoxicity of AH Plus and EndoSequence BC Sealer was related to time/dose-dependent manner, whilst MTA Fillapex cytotoxicity was showed...


Assuntos
Humanos , Meios de Cultura , Cimentos Dentários , Endodontia , Fibroblastos , Inflamação/radioterapia , Terapia com Luz de Baixa Intensidade , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Análise de Variância , Brasil , Gengiva
3.
Rio de Janeiro; s.n; 2015. 68 p. ilus, graf.
Tese em Português | LILACS, BBO | ID: biblio-867244

RESUMO

O sucesso do tratamento endodôntico depende da cuidadosa realização de todas as suas fases, terminando com uma obturação tridimensional que alcance todo o sistema de canais radiculares. Desta forma, os materiais obturadores, ou as substâncias liberadas, entrarão em contato com os tecidos perirradiculares, o que poderá influenciar a resposta inflamatória e o processo de reparo. A terapia laser de baixa potência (TLBP) tem sido estudada quanto à sua ação anti-inflamatória, favorecendo o reparo. O objetivo deste estudo foi investigar a produção das citocinas IL-1β, IL-6 e IL-8 por fibroblastos de gengiva humana (linhagem FMM1) como resposta à presença dos extratos dos cimentos endodônticos AH Plus, MTA Fillapex e EndoSequence BC Sealer, bem como a eficácia da TLBP, neste modelo. Para isto, extratos destes cimentos, recém-manipulados e após 24 h do endurecimento, foram preparados em meio de cultura DMEM fresco, conforme as normas ISO 10993-12. Inicialmente, a citotoxicidade dos cimentos foi avaliada, após a interação das células com a diluição seriada destes extratos (1:1 a 1:16), por meio do ensaio MTT. Para a análise da produção de citocinas, 106 células por poço foram cultivadas em placas de cultura de 24 poços, para a interação com os extratos dos cimentos, na diluição 1:4. Estabeleceram-se os grupos não irradiado e irradiado. No grupo irradiado, as culturas celulares receberam duas irradiações do laser InGaAlP (660 nm, 30 mW, 5 J/cm2 e área do feixe de 0,028 cm2), com intervalo de 12 h. O grupo não irradiado foi submetido às mesmas condições ambientais que o irradiado. Os sobrenadantes das culturas foram coletados, centrifugados, aliquotados e armazenados congelados, para a posterior análise pelo ensaio de ELISA. Todos os dados obtidos (médias ± erro padrão) foram tratados estatisticamente por ANOVA one-way, complementado pelo teste de Tuckey e ANOVA ...


Endodontic treatment success depends on careful accomplishment of all steps, finishing with a three-dimensional obturation that reachs the entire root canal system. Thus, the obturation materials or the substances that are released will be in contact with perirradicular tissues, which may influence the inflammatory response and the repair process. Low-level laser therapy (LLLT) has been studied about its anti-inflammatory action, improving the repair. The aim of this study was to investigate the production of IL-1β, IL-6 and IL-8 cytokines by human gingival fibroblasts (FMM1 lineage) as a response to the extracts of the endodontic cements AH Plus, MTA Fillapex and EndoSequence BC Sealer, besides the effectiveness of LLLT in this model. For that, freshly mixed and 24 h-set elutes of these sealers were prepared, in fresh DMEM, in accordance with ISO 10993-12. Firstly, cytotoxicity was assessed after cells were treated with cements extracts serial dilution (1:1 to 1:16), by MTT assay. To evaluate the cytokines production, 106 cells per well were cultured at 24-well-plates to interact with the 1:4 dilution of sealers extracts. Non-irradiated and irradiated groups were established. On the irradiated group, the cell culture received two InGaAlP laser irradiation (660 nm, 30 mW, 5 J/cm2, 0.028 cm2 spot size) at 12h-interval. The non-irradiated group was submitted to the same environment conditions of the irradiated group. The culture supernatants were collected, centrifuged, aliquoted and stored frozen to further analyse by ELISA assay. Data obtained (media ± standard error) were treated by ANOVA one-way, complemented by Tuckey’s test and ANOVA two-way, with Bonferroni correction (p< 0.05). The cytotoxicity of AH Plus and EndoSequence BC Sealer was related to time/dose-dependent manner, whilst MTA Fillapex cytotoxicity was showed ...


Assuntos
Humanos , Meios de Cultura , Cimentos Dentários , Endodontia , Fibroblastos , Inflamação/radioterapia , Terapia com Luz de Baixa Intensidade , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Análise de Variância , Brasil , Gengiva