Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo | IMSEAR | ID: sea-192324

RESUMO

In elderly patients with few remaining teeth, overdenture is a good treatment option. Roots beneath the denture protect the alveolar ridge, offer proprioception and improve retention, stability and masticatory efficiency of dentures. Customization of attachments available is a viable alternative for some patients in which prefabricated attachments cannot be placed or in which cost is a factor; to improve the final outcome of the treatment. Due to competitive commercialization, implant treatment has become the norm in current dentistry and the concept of tooth supported overdentures has eclipsed, but with proper case selection, thorough treatment planning and modifications in the denture such as customization of attachments, amalgam stops, cross-linked teeth, and metallic mesh can be applied to prolong the longevity and success of the attachment overdenture prosthesis.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 79-82, 2011.
Artigo em Chinês | WPRIM | ID: wpr-414045

RESUMO

Objective To facilitate activity measurement by using the thimble ionization chamber in hospitals,to obtain air kerma scatter correction factor of medical afterloading of 192Ir source by developing an available and convenient calculation method.Methods According to International Atomic Energy Agency (IAEA) 1079 Report to calculate the scatter correction factor of 192 Ir source,to measure air kenna of 192Ir source with and without lead shield using thimble ionization chamber.Simulation measurement conditions were used to calculate scatter correction factor of 192Ir source and comparison was made between experimental results and literature records.At the same time,the different ionization chamber models were simulated at different room sizes to obtain scattering correction factor of 192 Ir source.ResultsComparison was made between the simulation scatter correction factors of 192Ir source and experiment by the shadow shield,and the relative deviation was 0.8%.The deviation of the 192 Ir activity calculated according to the simulated scatter correction factor and measured by well type ionization chamber was 2.4%.By comparison between the calculated results by using two kinds of spherical ionization chamber and those ones deduced by IAEA 1079 Report,the relative deviations ranged within 0.3%-0.4%.Five different types of thimble ionization chamber and different room sizes were simulated and calculated by MC simulation,with the relative deviation within 3%.Conclusions Monte Carlo simulation method for calculating afterloading 192 Ir source's scatter correction factor is feasible,and this method is convenient for use in the thimble chamber for brachytherapy QA work in the hospital.

3.
Korean Journal of Dermatology ; : 237-239, 2010.
Artigo em Coreano | WPRIM | ID: wpr-196351

RESUMO

Green nail syndrome is a chronic nail infection by Pseudomonas aeurginosa. Infected lesions can involve both finger and toe nails and cause greenish discoloration and onycholysis. Environmental factors such as frequent hydration and external trauma are predisposing factors. A 37-year-old patient was diagnosed with green nail syndrome on the right thumb. She used a thimble for a long time as a dress designer. Herein, we describe an uncommon case of green nail syndrome by chronic thimble use as a rare and an educational report.


Assuntos
Adulto , Humanos , Dedos , Unhas , Onicólise , Pseudomonas , Pseudomonas aeruginosa , Serratia marcescens , Polegar , Dedos do Pé
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA