Asian Spine Journal ; : 194-198, 2012.
Artigo em Inglês | WPRIM | ID: wpr-68123

RESUMO

Surgical treatment of a hangman's fractures is technically demanding, even when using the standard open procedure. In this case report, a type II hangman's fracture was treated by percutaneous posterior screw fixation, without a midline incision, using intraoperative, full rotation, three-dimensional (3D) image (O-arm)-based navigation. A 48-year-old woman was injured in a motor vehicle accident and diagnosed with a unilateral hangman's fracture associated with subluxation of the C2 vertebral body on C3. After attaching the reference arc of the 3D-imaging system to the headholder, the cervical spine was screened using an O-arm without anatomical registration. Drilling and screw fixation were performed using a guide tube while referring to the reconstructed 3D-anatomical views. The operation was successfully completed without technical difficulties or neurovascular complications. This percutaneous procedure requires less dissection of normal tissue, which may allow earlier recovery. However, further validation of this procedure for its effectiveness and safety is required.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Imageamento Tridimensional , Mandrillus , Veículos Automotores , Coluna Vertebral