Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1017640

RESUMO

Field effect transistor(FET)biochemical sensors show great potential in the fields of environmental monitoring,food safety,disease diagnosis and clinical treatment due to their low noise,low power consumption,label-free,easy integration and miniaturization characteristics.Two-dimensional(2D)materials,as a new generation of channel materials for FET biochemical sensors,have atomic-level thickness,high carrier mobility,high specific surface area and tunable bandgap,which can further improve the performance of FET biochemical sensors,extend their application areas,and promote the rapid development of FET biochemical sensors.This review focused on the development and latest progress of 2D material-based FET biochemical sensors,along with the challenges and prospects of 2D material-based FET biochemical sensors,which aimed to provide new device design conceptions and promote the further development of biochemical sensing technology.

2.
Artigo em Chinês | WPRIM | ID: wpr-1021630

RESUMO

BACKGROUND:Traditional lateral cephalometric radiographs always suffer from some problems,such as magnification distortion,left and right overlap inconsistency and so on,while the cone-beam CT can truly display the three-dimensional structure of the craniofacial region.Performing three-dimensional reconstruction of cone-beam CT and then transforming the cone-beam CT in the selected area into the two-dimensional image can make the overlap between the left and right sides consistent and reduce the influence of surrounding tissue structures. OBJECTIVE:To explore the consistency of quantitative analysis of cervical vertebral bone age between two kinds of cone-beam CT transformed two-dimensional images with different integrated thicknesses and traditional lateral cephalometric radiographs. METHODS:The cone-beam CT and lateral cephalometric radiograph data of 118 adolescent orthodontic patients were collected.Firstly,the cone-beam CT image was reconstructed in 3D imaging software.After reconstruction,two types of cone-beam CT images with different integrated thicknesses were selected in the sagittal interface and transformed into two-dimensional images,which were named ICB-1 and ICB-2,respectively.The Zhibeiyun system was used to measure and calculate the angle between the concave base of the second cervical vertebra and the lower edge of the vertebral body(@2),the ratio of the third cervical spine to the posterior height(AH3/PH3),the ratio of height to width of the fourth cervical spine(H4/W4)in lateral cephalometric radiograph,ICB-1,ICB-2 and the cervical vertebral bone age.After an interval of two weeks,20 adolescents were randomly selected to repeat the above measurements.The intraclass correlation coefficient(ICC)method was used to evaluate the repeatability of the three images in measuring cervical bone age.Paired t-test was used to analyze the consistency of cervical bone age measurements between the three images.The Kappa test was used to analyze the consistency of cervical vertebral bone age staging assessment between the three images. RESULTS AND CONCLUSION:(1)ICC of AH3/PH3 in the lateral cephalometric radiograph group was<0.9,and the ICC of other measurement items in each group was>0.9.(2)Paired t-test results showed that there were statistical differences in AH3/PH3 and H4/W4 between the ICB-1 group and lateral cephalometric radiograph group and between the ICB-1 group and ICB-2 group(P<0.05),and there were no statistically significant differences in the other items between the three groups(P>0.05).(3)The Kappa test results showed that the Kappa coefficients of the two groups were all more than 0.8 according to the staging of cervical vertebral bone age in three groups(P<0.001).(4)It is indicated that the repeatability of ICB-1 and ICB-2 in the measurement of cervical vertebral bone age is better than that of lateral cephalometric radiographs.Lateral cephalometric radiographs,ICB-1 and ICB-2 have good consistency in the measurement of cervical vertebral bone age,but considering the integrity of cervical vertebra structure,ICB-2 is more suitable for quantitative analysis of cervical vertebral bone age than ICB-1.

3.
Artigo em Chinês | WPRIM | ID: wpr-1021735

RESUMO

BACKGROUND:The treatment of bone defects has always been a pressing clinical challenge for medical practitioners.The use of gelatin methacryloyl for three-dimensional extracellular cultivation offers a promising direction for the treatment of extensive bone defects. OBJECTIVE:To review the research progress of gelatin methacryloyl as a three-dimensional cell culture scaffold in bone tissue engineering,aiming to provide further references for clinical bone defect repair. METHODS:Computerized searches were conducted on the CNKI and PubMed databases for articles published from January 1986 to August 2023.The search terms in Chinese and English were"bone defect,bone tissue engineering,biomaterial scaffold,hydrogel,photocrosslinked hydrogel,gelatin methacryloyl,three-dimensional culture,cell culture"and"bone defect,bone tissue engineering,biomaterial scaffold,hydrogel,gelatin methacryloyl,three-dimensional culture,cell culture",respectively.Finally,68 articles were included for review and analysis. RESULTS AND CONCLUSION:(1)When compared to two-dimensional culture techniques,three-dimensional culture can construct a three-dimensional space under aseptic conditions,more effectively simulating the in vivo environment.It provides cells with the appropriate temperature,pH,and sufficient nutrients,allowing cells to grow and proliferate normally outside the body while maintaining their regular structure and function,offering unique advantages.(2)In the realm of bone tissue engineering,hydrogels stand out as the preferred choice for biomaterial scaffolds.Their excellent biocompatibility,degradability,and inherent three-dimensional network structure make them invaluable in bone regeneration studies.(3)The physical and biological properties of gelatin methacryloyl are influenced by factors such as concentration,light exposure duration,type of photoinitiator,and the overall reaction system.These properties can affect cell adhesion,growth,and proliferation,and even the morphology and function of cells.(4)Gelatin methacryloyl,recognized for its excellent biocompatibility,tunable physical properties,injectability,and photosensitivity,has been extensively used in three-dimensional cell encapsulation,three-dimensional bioprinting,and stereolithography techniques based on digital light processing in three-dimensional cell culture systems.(5)Utilizing a range of composite gelatin methacryloyl in three-dimensional cell culture can significantly promote vascularization and bone regeneration,paving the way for enhanced clinical solutions to bone defects.(6)At present,there is a noticeable gap in standardized guidelines concerning the sources,synthesis methods,and safety of gelatin methacryloyl.It is crucial to intensify research efforts to optimize gelatin methacryloyl's application in the three-dimensional cell culture field.

4.
Artigo em Inglês | WPRIM | ID: wpr-1012678

RESUMO

@#Introduction: Race estimation of unknown individual is essential in forensic investigation. The resiliency of frontal sinus makes it a potential tool for biological profiling, particularly in cases where fragmented skeleton persists. Geometric morphometrics is an efficient way to characterise shape. However, the use of frontal sinus to identify race of Malaysians is yet to be investigated. This research employed a two-dimensional (2D) geometric morphometric to examine the morphological differences of the frontal sinus among the major races in Malaysia. Methods: Lateral skull radiographs which comprising of 453 adult Malaysian (151 Malays, Chinese and Indian respectively) were used. The 2D landmarks of eight were placed on the digitalized radiographs and 2D geometric morphometric analysis was performed using MorphoJ software. Results: Procrustes ANOVA revealed a significantly different frontal sinus shape (p-value < 0.05) between races. Canonical variate analysis showed significantly different frontal sinus morphology (p-value < 0.05) between Malay and Indian as well as Chinese and Indian. Discriminant function analysis with cross-validation demonstrated a 57.4% accuracy rate. Conclusion: This population-specific study based on frontal sinus of Malaysians using the 2D geometric morphometric, though less reliable, sheds new light on the potential applicability of this method for race estimation purpose.

5.
Chinese Herbal Medicines ; (4): 27-41, 2024.
Artigo em Inglês | WPRIM | ID: wpr-1010752

RESUMO

Traditional Chinese medicines (TCMs) possess a rich historical background, unique theoretical framework, remarkable therapeutic efficacy, and abundant resources. However, the modernization and internationalization of TCMs have faced significant obstacles due to their diverse ingredients and unknown mechanisms. To gain deeper insights into the phytochemicals and ensure the quality control of TCMs, there is an urgent need to enhance analytical techniques. Currently, two-dimensional (2D) chromatography, which incorporates two independent separation mechanisms, demonstrates superior separation capabilities compared to the traditional one-dimensional (1D) separation system when analyzing TCMs samples. Over the past decade, new techniques have been continuously developed to gain actionable insights from complex samples. This review presents the recent advancements in the application of multidimensional chromatography for the quality evaluation of TCMs, encompassing 2D-gas chromatography (GC), 2D-liquid chromatography (LC), as well as emerging three-dimensional (3D)-GC, 3D-LC, and their associated data-processing approaches. These studies highlight the promising potential of multidimensional chromatographic separation for future phytochemical analysis. Nevertheless, the increased separation capability has resulted in higher-order data sets and greater demands for data-processing tools. Considering that multidimensional chromatography is still a relatively nascent research field, further hardware enhancements and the implementation of chemometric methods are necessary to foster its robust development.

6.
Artigo em Chinês | WPRIM | ID: wpr-1039886

RESUMO

ObjectiveTo evaluate the changes in cardiac structure and ventricular function in patients with Anderson-Fabry Disease (AFD) by two-dimensional speckle tracking echocardiography (2D-STE) and to explore the characteristics of their early cardiac involvement. MethodsAll 45 patients diagnosed with AFD in this observational study underwent routine ultrasonic cardiogram (UCG) examination and 2D-STE. The patients were divided into 2 groups based on UCG measurements: with left ventricular hypertrophy (interventricular septum or posterior left ventricular wall thickness ≥12 mm) and without left ventricular hypertrophy. TomTec software was used to analyze the echocardiographic images, then the baseline data, UCG routine parameters and myocardial strain of the two groups were compared. ResultsThe study included 27 males (60.0%) and 18 females (40.0%), with an average age of (32.33±16.11), 17 cases (37.78%) with left ventricular hypertrophy and 28 cases (62.22%) without left ventricular hypertrophy. All patients had normal left ventricular ejection fraction (LVEF) (> 50%). Compared with those without left ventricular hypertrophy, patients with left ventricular hypertrophy had significantly more target organ involvement, significantly higher E/A and average E/E' ratios (P < 0.05). No statistical difference was found in global and segmental longitudinal strain (LS), circumferential strain (CS) and radial strain (RS) of the endocardium and myocardium between the two groups (all P > 0.05). There were lower absolute values of global and segmental LS and CS in the myocardium than in the endocardium (all P < 0.05), and higher absolute values of LS and RS in the mid segment than in the basal and apical segments (all P < 0.05). ConclusionsThere is no significant association between early systolic dysfunction and left ventricular wall thickness. 2D-STE strain can be used to detect AFD in the early stage. Ventricular wall myocardium exhibits more serious involvement than endocardium and mid segment was less involved than the apical and basal segments.

7.
Artigo em Chinês | WPRIM | ID: wpr-1026207

RESUMO

Objective To analyze the diagnostic value of two-dimensional(2D)ultrasound features combined with ultrasonic elastic strain rate ratio(SR)for breast cancer and discuss their correlations with pathological prognostic indicators.Methods The clinical data of 265 patients with breast cancer admitted to the 2nd Affiliated Hospital of Chengdu Medical College from January 2020 to December 2021 were analyzed retrospectively.Through pathological examination,171 cases were diagnosed with benign lesions(benign group)and 94 cases with malignant lesions(malignant group).The 2D ultrasound and ultrasound elastography imaging data were collected and compared for the two groups in terms of ultrasound appearance and SR.The positive rates of estrogen receptor(ER),progesterone receptor(PR),and proto-oncogene(CerbB-2)were recorded.Receiver operating characteristic(ROC)curve was drawn to analyze the diagnostic efficiency of 2D ultrasound and SR for breast cancer;and Pearman correlation analysis was conducted to assess the correlations between 2D ultrasound features/SR and ER/PR/CerbB-2.Results The 2D ultrasound features such as spicule sign,posterior echo attenuation,microcalcification,lymph node metastasis,and abundant blood flow were more common in malignant group,and the SR was significantly higher than that in benign group(P<0.05).The positive rates of ER,PR and CerbB-2 in malignant group were 59.57%,75.53%and 47.87%,respectively,significantly higher than those in benign group(P<0.05).ROC curve analysis showed that the AUC values of 2D ultrasound,SR,and their combination for breast cancer diagnosis were 0.586,0.743,and 0.761,respectively,indicating a significantly higher diagnostic efficiency of the combined detection than 2D ultrasound or SR alone(P<0.05).The occurrences of spicule sign and posterior echo attenuation and SR were higher in ER-positive patients than in ER-negative patients(P<0.05);lymph node metastasis was more prevalent in PR-positive patients,and their SR was higher than PR-negative patients(P<0.05);CerbB-2 positive patients had more microcalcifications and higher SR value as compared with CerbB-2 negative patients(P<0.05).Pearman correlation analysis revealed that there were positive correlations between 2D ultrasound features such as spicule sign/posterior echo attenuation and ER,lymph node metastasis and PR,microcalcification and CerbB-2,SR and ER/PR/CerbB-2(P<0.05).Conclusion The combination of 2D ultrasound features and SR provides reliable imaging information for the diagnosis of breast cancer.The spicule sign,posterior echo attenuation,lymph node metastasis,microcalcification and SR are correlated to the pathological prognostic indicators(ER,PR,and CerbB-2).

8.
Acta Pharmaceutica Sinica ; (12): 1128-1137, 2023.
Artigo em Chinês | WPRIM | ID: wpr-978692

RESUMO

As a treasure resource of novel drug lead compounds, how to rapidly and high-efficiently screen and isolate active components from natural products is critical. Thanks to its high resolution, high automation and flexible integration, online two-dimensional liquid chromatography has great potential for screening active ingredients from complex matrices by integrating a highly specific bio-recognition process into a two-dimensional liquid chromatography system before, on or after the column separation. This review comprehensively summarized recent developments, applications and shortcomings of online two-dimensional liquid chromatography for natural product screening from different integration modes, including pre-column, on-column and post-column screening methods.

9.
Artigo em Chinês | WPRIM | ID: wpr-981279

RESUMO

Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.


Assuntos
Humanos , Nódulo da Glândula Tireoide , Neoplasias da Glândula Tireoide/diagnóstico , Carcinoma Papilar/patologia , Ultrassonografia/métodos , Estudos Retrospectivos
10.
Acta Pharmaceutica Sinica B ; (6): 1303-1317, 2023.
Artigo em Inglês | WPRIM | ID: wpr-971759

RESUMO

In situ and real-time monitoring of responsive drug release is critical for the assessment of pharmacodynamics in chemotherapy. In this study, a novel pH-responsive nanosystem is proposed for real-time monitoring of drug release and chemo-phototherapy by surface-enhanced Raman spectroscopy (SERS). The Fe3O4@Au@Ag nanoparticles (NPs) deposited graphene oxide (GO) nanocomposites with a high SERS activity and stability are synthesized and labeled with a Raman reporter 4-mercaptophenylboronic acid (4-MPBA) to form SERS probes (GO-Fe3O4@Au@Ag-MPBA). Furthermore, doxorubicin (DOX) is attached to SERS probes through a pH-responsive linker boronic ester (GO-Fe3O4@Au@Ag-MPBA-DOX), accompanying the 4-MPBA signal change in SERS. After the entry into tumor, the breakage of boronic ester in the acidic environment gives rise to the release of DOX and the recovery of 4-MPBA SERS signal. Thus, the DOX dynamic release can be monitored by the real-time changes of 4-MPBA SERS spectra. Additionally, the strong T2 magnetic resonance (MR) signal and NIR photothermal transduction efficiency of the nanocomposites make it available for MR imaging and photothermal therapy (PTT). Altogether, this GO-Fe3O4@Au@Ag-MPBA-DOX can simultaneously fulfill the synergistic combination of cancer cell targeting, pH-sensitive drug release, SERS-traceable detection and MR imaging, endowing it great potential for SERS/MR imaging-guided efficient chemo-phototherapy on cancer treatment.

11.
Artigo em Chinês | WPRIM | ID: wpr-981568

RESUMO

The increasing prevalence of the aging population, and inadequate and uneven distribution of medical resources, have led to a growing demand for telemedicine services. Gait disturbance is a primary symptom of neurological disorders such as Parkinson's disease (PD). This study proposed a novel approach for the quantitative assessment and analysis of gait disturbance from two-dimensional (2D) videos captured using smartphones. The approach used a convolutional pose machine to extract human body joints and a gait phase segmentation algorithm based on node motion characteristics to identify the gait phase. Moreover, it extracted features of the upper and lower limbs. A height ratio-based spatial feature extraction method was proposed that effectively captures spatial information. The proposed method underwent validation via error analysis, correction compensation, and accuracy verification using the motion capture system. Specifically, the proposed method achieved an extracted step length error of less than 3 cm. The proposed method underwent clinical validation, recruiting 64 patients with Parkinson's disease and 46 healthy controls of the same age group. Various gait indicators were statistically analyzed using three classic classification methods, with the random forest method achieving a classification accuracy of 91%. This method provides an objective, convenient, and intelligent solution for telemedicine focused on movement disorders in neurological diseases.


Assuntos
Humanos , Idoso , Doença de Parkinson/diagnóstico , Envelhecimento , Algoritmos , Marcha , Extremidade Inferior
12.
Artigo em Chinês | WPRIM | ID: wpr-986062

RESUMO

Objective: To evaluate the right ventricular function using two-dimensional speckle tracking echocardiography (2-D STE) and analyze the associated risk factors of right ventricular dysfunction in patients with silicosis. Methods: All 104 patients with silicosis treated in the Department of Occupational Medicine and Toxicology in Beijing Chao-Yang Hospital, Capital Medical University from May 2021 to September 2022 were enrolled in this study in October 2022. The clinical information of patients such as general data, arterial blood gas analysis and pulmonary function test were collected. The right ventricular function of patients was evaluated by 2-D STE-derived right ventricular free wall longitudinal strain (RVFWLS) and conventional echocardiographic-derived parameters, including right ventricular fractional area change (RVFAC), tricuspid annular plane systolic excursion (TAPSE) and doppler tissue imaging-derived tricuspid lateral annular systolic velocity (S'), respectively. Based on their RVFWLS, the patients were divided into right ventricular dysfunction group and normal right ventricular function group. Risk factors for right ventricular dysfunction in patients with silicosis were analyzed using binary logistic regression analysis. Results: A total of 104 silicosis patients were enrolled, with aneverage age (65.52±11.18) years old, among whom including 57 cases diagnosed with stage Ⅰ/Ⅱ silicosis and 47 cases diagnosed with stage Ⅲ silicosis. 26 (25.00%) patients concurrent right ventricular dysfunction. The abnormal rates of RVFAC, TAPSE and S' in patients were 16.35% (17 cases), 21.15% (22 cases) and 6.73% (7 cases), respectively. The RVFAC and TAPSE in right ventricular dysfunction group were lower than those in normal right ventricular function group, and the incidence of pulmonary arterial systolic pressure ≥36 mmHg was higher than that in normal right ventricular function group (P<0.05). Logistic regression analysis showed that arterial partial pressure of oxygen (OR=0.932, 95%CI: 0.885-0.981, P=0.007) was the protective factor, and the forced expiratory volume in 1 second (FEV(1)) /forced vital capacity (FVC) ratio<70% (OR=5.484, 95%CI: 1.049-28.662, P=0.044) and stage Ⅲ silicosis (OR=6.343, 95%CI: 1.698-23.697, P=0.007) were the risk factors for silicosis patients concurrent right ventricular dysfunction. Conclusion: The incidence of right ventricular dysfunction is higher in patients with stage Ⅲ silicosis than that in patients with stage Ⅰ/Ⅱ silicosis. Using 2-D STE can help the early detection of silicosis with right ventricular dysfunction. Hypoxemia, airflow limitation and the stage Ⅲ silicosis are the risk factors for silicosis patients concurrent right ventricular dysfunction.


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita , Ecocardiografia , Fatores de Risco , Silicose/diagnóstico por imagem
13.
Artigo em Chinês | WPRIM | ID: wpr-992822

RESUMO

Objective:To evaluate the fetal heart shape and function in tetralogy of Fallot (TOF) by fetal heart quantitative analysis (fetal HQ).Methods:A total of 52 fetuses with TOF diagnosed by fetal echocardiography and 200 normal fetuses matched with their gestational weeks from March 2020 to March 2022 at Sir Run Run Shaw Hospital, Zhejiang University were retrospectively evaluated. The basic parameters of fetal cardiac blood vessels in the two groups were measured by fetal HQ technology and conventional M-mode ultrasound technology: aortic valve diameter(AV), pulmonary artery valve diameter(PV), main pulmonary artery diameter (MPA) and Z-score. The overall morphometric measurements including end-diastolic length diameter, transverse diameter, area, and global spherical index (GSI) of the fetal heart in the 4-chamber view(4CV), area and length of the right and left ventricles and their ratios. Measurements of left and right ventricular function included ejection fraction (EF), fraction area change rate (FAC), tricuspid annular plane systolic excursion (TAPSE), left and right ventricular global longitudinal strain (GLS), and left and right ventricular end-diastolic diameter (ED), spherical index (SI), and fractional shortening rate (FS) of 24-segments. The differences of above parameters between TOF group and control group were compared. In addition, the relationships between the absolute value of left and right ventricular GLS of TOF fetus and PV/AV, PV Z-score and MPA Z-score were analyzed. The optimal critical values of GSI, left ventricular EF and left ventricular FAC of TOF fetus were determined by ROC curve, and their corresponding sensitivity and specificity were obtained.Results:Compared with control group, there were significant differences in 4CV end-diastolic length, area, GSI, left ventricular area, left ventricular length, left ventricular EF, left ventricular FAC and left ventricular GLS in TOF group (all P<0.05). There were significant differences in ED between left ventricular 15-24 segments and right ventricular 1-21 segments (all P<0.05). There were significant differences in SI between left ventricular 1-16 segments, 21-24 segments and all segments of right ventricle (all P<0.05). The differences in FS were statistically significant (all P<0.05) when comparing all segments of the left ventricle and 1-2 segments of the right ventricular, and the remaining parameters were not statistically significant (all P>0.05). The left ventricular GLS absolute value of TOF fetuses was positively correlated with PV/AV, PV Z-score and MPA Z-score( rs=0.338, 0.441 and 0.458, all P<0.05), the right ventricular GLS absolute value of TOF fetuses was positively correlated with PV AV, PV Z-score and MPA Z-score( rs=0.418, 0.368 and 0.338, all P<0.05). The optimal critical values of GSI, left ventricular EF, and left ventricular FAC in the diagnosis of fetal TOF were 1.19, 59.05%, and 44.4%, respectively. At this time, the sensitivities of diagnosis of TOF were 0.78, 0.75, and 0.80, respectively. The specificities were 0.88, 0.88 and 0.83, respectively. The areas under ROC curve were 0.89, 0.88 and 0.89, respectively. Conclusions:Fetal HQ technology can provide a simple and reliable quantitative evaluation of fetal heart shape and function, and provide certain theoretical parameters for the study of fetal heart shape and function.

14.
Artigo em Chinês | WPRIM | ID: wpr-992835

RESUMO

Objective:To investigate the correlations between serum E selectin, intercellular adhesion molecule 1 (ICAM-1), vascular cell adhesion molecule 1 (VCAM-1) and left ventricular geometry and function in patients with obstructive sleep apnea syndrome (OSAS) combined with prehypertension (pre-HT).Methods:A total of 462 patients with pre-HT and OSAS diagnosed by polysomnography (PSG) in the sleep monitoring unit of the Department of Respiratory and Critical Care Medicine at the First Hospital of Shanxi Medical University from July 2019 to July 2022 were restrospectively analysed, and 52 patients with pure pre-HT (pre-HT group) and 73 patients with pure OSAS (OSAS group) in the same period were selected as the control group. OSAS and pre-HT patients were divided into four groups according to left ventricular geometry: normal geometry (NG) group, concentric remodeling (CR) group, eccentric hypertrophy (EH) group and concentric hypertrophy (CH) group. The general clinical data, PSG parameters, blood biochemical parameters and left ventricular structure and function parameters were compared among the six groups. Pearson correlation and multivariate Logistic regression were used to analyze the correlation between E-selection, ICAM-1, VCAM-1, general clinical data, PSG parameters, blood biochemical parameters with left ventricular geometry and function.Results:①Serum E selectin, ICAM-1, and VCAM-1 concentrations increased sequentially from the NG, CR, and EH to CH groups, with the most significant increase in CH group (all P<0.05). In addition, there were statistically significant differences in age, body mass index (BMI), OSAS severity, neck circumference, waist circumference, systolic blood pressure (SBP), diastolic blood pressure (DBP), Glu, lowest oxygen saturation (Lowest-SaO 2), mean oxygen saturation (Mean-SaO 2), percentage of time with oxygen saturation below 90% of total sleep time (T90), left ventricular end-diastolic diameter (LVEDd), interventricular septal thickness (IVST), left ventricular posterior wall thickness (LVPWT), left ventricular mass index (LVMI), relative ventricular wall thickness (RWT), left ventricular ejection fraction (LVEF), peak mitral early diastolic flow velocity/peak mitral late diastolic flow velocity (E/A), E wave deceleration time (DT), A wave duration (AD), and isovolumic relaxation time (IVRT), and overall long-axis longitudinal strain (GLS) and so on(all P<0.05). ②Pearson correlation analysis showed that E selectin was negatively correlated with LVEF, E/A, e′, E/e′, IVRT, and GLS ( r=-0.236, -0.131, -0.224, -0.215, -0.285, -0.336; all P<0.05). ICAM-1 was negatively correlated with LVEF, E, E/A, e′, IVRT, and GLS( r=-0.130, -0.129, -0.104, -0.351, -0.252, -0.259; all P<0.05). VCAM-1 was negatively correlated with E, e′, and IVRT ( r=-0.132, -0.312, -0.387; all P<0.001). ③Multifactorial logistic regression analysis showed that E selectin and VCAM-1 were independently correlated with EH (β=1.139, OR=3.124, P=0.030; β=1.288, OR=3.626, P<0.001) and with CH (β=1.178, OR=3.248, P=0.013; β=1.108, OR=3.028, P<0.001). Conclusions:E selection and VCAM-1 were independently correlated with hypertrophic left ventricular geometry, suggesting that E selectin and VCAM-1 may be involved in the process of abnormal left ventricular structure and function in patients with OSAS combined with pre-HT.

15.
Artigo em Chinês | WPRIM | ID: wpr-992861

RESUMO

Objective:To investigate the effect of instantaneous flow rate on the consistency of diagnostic accuracy of severe degenerative mitral regurgitation (DMR) using proximal isovelocity surface area (PISA).Methods:From June 2019 to June 2021, 75 patients with DMR who underwent echocardiography in Department of Echocardiography of Zhongshan Hospital, Fudan University were prospectively enrolled. The instantaneous flow rate of DMR during the systolic phase was calculated using M-mode PISA(PISA M-mode), and a time-integrated curve was plotted. Regurgitant volume (RVol) and effective regurgitant orifice area (EROA) were calculated by traditional PISA (PISA max), pair PISA (PISA pair), and PISA M-mode, respectively. RVol acquired from cardiac magnetic resonance (CMR) volumetric method in 22 patients of the enrolled patients. The correlation and consistency of RVol acquired between the three PISA methods and CMR were compared. Agreement of diagnostic accuracy of severe mitral regurgitation (sMR) acquired between the three PISA methods and multi-parameter algorithm by American Society of Echocardiography (ASE) was analyzed using Cohen′s Kappa analysis. Results:The curve of instantaneous flow rate of DMR showed unimodal pattern with the peak at mid-late systolic phase. The correlation of RVol acquired between PISA methods and CMR was moderate for PISA max and PISA pair ( r=0.77, 0.80, both P<0.001), whereas PISA M-mode presented strong correlation with CMR ( r=0.87, P<0.001). RVol acquired from PISA max was larger than that of CMR[(69.1±37.1) ml vs (49.0±29.0)ml, P=0.002]. Both PISA max and PISA pair were shown moderate agreement of diagnostic accuracy of sMR with ASE multi-parameters algorithm (RVol: κ=0.496, 0.525, both P<0.001; EROA: κ=0.570, 0.578, both P<0.001), while PISA M-mode presented strong agreement (RVol: κ=0.867 and EROA: κ=0.802, both P<0.001). Conclusions:Based on the unimodal pattern of instantaneous flow rate in patients with DMR, PISA max may significantly overestimate RVol, exposing a significant proportion of patients with DMR to unnecessary MR surgery. PISA M-mode presents better correlation and consistency with CMR on the quantification of RVol compared with PISA max and PISA pair, and may improve the diagnostic accuracy of quantification of sMR using PISA.

16.
Artigo em Chinês | WPRIM | ID: wpr-992862

RESUMO

Objective:To explore the application value of two-dimensional speckle tracking echocardiography (2D-STE) in measuring the global longitudinal peak strain of the right atrium (PRAGLS) in normal fetuses and evaluating PRAGLS in assessing right atrial function in fetuses with moderate and severe tricuspid regurgitation (TR).Methods:A total of 25 fetuses diagnosed with moderate and severe TR, who underwent fetal echocardiography at Run Run Shaw Hospital, Zhejiang University College of Medicine between October 2020 and May 2022, were selected as the case group. Their gestational age ranged from 25.00(24.00, 30.00)weeks. Additionally, 100 normal singleton fetuses were chosen as the control group, with a gestational age of 25.83(23.00, 28.75)weeks. Standard basal or apical four-chamber clips were acquired and inputted into TOMTEC-ARENA offline cardiac analysis software for analysis. The fetal PRAGLS values of the two groups were obtained, as well as the routine obstetric ultrasound measurements and fetal echocardiographic parameters of both groups: fetal heart rate (FHR), biparietal diameter (BPD), femur length (FL), aortic annulus inner diameter (AO), pulmonary annulus inner diameter (PA), PA/AO ratio, right atrial end-systolic length (RAESL), right atrial end-systolic diameter (RAESD), right atrial end-systolic area (RAESA), right ventricular end-diastolic diameter (RVEDD), and tricuspid annular plane systolic excursion (TAPSE). The peak TR velocity and pressure gradient were simultaneously measured in the case group.The differences in fetal PRAGLS and other parameters between the two groups were compared and analyzed. The correlation between fetal PRAGLS and gestational age (GA) and routine measurements was assessed for both groups. Intra- and inter-observer repeatability tests were conducted using the intragroup correlation coefficient (ICC).Results:A significant difference in PRAGLS was observed between the two groups ( t=11.55, P<0.01). The TAPSE difference between the two groups was also statistically significant ( Z=3.45, P=0.01). Notable differences were found in AO, PA, PA/AO, RAESL, RAESD, and RAESA between the two groups (all P<0.05), but no significant differences were identified in age, GA, FHR, BPD, FL, and RVEDD between the two groups (all P>0.05). PRAGLS in the control group exhibited a moderate negative correlation with GA ( r=-0.47, P<0.01) and were correlated with BPD, FL, AO, PA, RAESL, RAESD, RAESA, and RVEDD ( r=-0.50, -0.46, -0.39, -0.43, -0.45, -0.36, -0.43, -0.32, all P<0.05). No significant correlation was observed with maternal age, FHR, PA/AO, and TAPSE (all P>0.05). No significant correlation between PRAGLS and GA or other conventional parameters was found in the case group (all P>0.05). The inter-measurer and intra-measurer ICC of PRAGLS in the control group were 0.87 and 0.79, respectively, while the inter-measurer and intra-measurer ICC of PRAGLS in the case group were 0.94 and 0.97, respectively, demonstrating good consistency. Conclusions:2D-STE exhibits strong feasibility and reproducibility in assessing fetal atrial function.Fetuses with moderate and severe TR display decreased PRAGLS, suggesting impaired right atrial reservoir function. Right atrial strain introduces a novel method for evaluating fetal cardiac function.

17.
Artigo em Chinês | WPRIM | ID: wpr-1022936

RESUMO

The current situation and problems of the consumables management in the ward unit of the emergency medical team were introduced.An intelligent consumables management belt was prepared based on two-dimensional code technology to solve the problems of the ward unit in consumables positioning,storage,inconvenient access,management process and support cost,which enhanced the efficacy of the emergency medical team greatly.

18.
Chinese Journal of Medical Imaging ; (12): 1274-1279,1281, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1026330

RESUMO

Purpose To use two-dimensional speckle tracking imaging(2D-STI)to evaluate left ventricular myocardial strain in term and preterm neonates.Materials and Methods A total of 81 neonates who accepted echocardiography in Soochow University Affiliated Children's Hospital from February to August 2018 were retrospectively enrolled,including 42 term neonates and 39 preterm neonates.Longitudinal and circumferential peak strain of each segment of left ventricle were measured by 2D-STI,and the average global longitudinal peak strain(GLPS-avg)and the average global circumferential peak strain(GCPS-avg)of left ventricular were measured too.Left ventricular ejection fraction(LVEF-M,LVEF-Simpson),short-axis shortening rate(LVFS-M),left ventricular end-diastolic diameter(LVEDD),and tissue Doppler imaging parameters(E',A' and E'/A')of the septal mitral annulus were also measured.The differences in each segment of left ventricle and echocardiography between term neonates and preterm neonate were further compared.Results There were statistically significant differences in GLPS-avg,the global longitudinal peak strain from the apical two-chamber view(GLPS-a2c),GCPS-avg and the global circumferential peak strain in the middle and apical segments(GCPS-M ang GCPS-A)(t=-3.60--2.18,all P<0.05)between term neonates and preterm neonates,while there were no significant differences between the global longitudinal peak strain from the apical four-chamber and three-chamber view(GLPS-a4c and GLPS-a3c),the global circumferential peak strain in the basal segments(GCPS-M)(all P>0.05).There were statistically significant differences in GLPS-a4c,GLPS-a2c,GLPS-a3c in preterm neonates group(F=3.20,P=0.044),and the strain value GLPS-a4c was the highest.There were statistically significant differences in GCPS-B,GCPS-M,GCPS-A in preterm neonates group(F=79.15,P<0.001).There were statistically significant differences in GCPS-B,GCPS-M,GCPS-A in term neonates group(F=97.95,P<0.001),and the strain value increased from the basal segment to the apical segments.There was statistically significant difference in LVEDD between term neonates and preterm neonates(all P<0.05).There were no statistically significant differences in LVEF-M,LVEF-Simpson,LVFS-M,E',A' and E'/A' between term neonates and preterm neonates(all P>0.05).Conclusion 2D-STI may be a useful method of measuring left ventricular myocardial systolic function and can provide early detection of differences in left ventricular myocardial contraction between term and preterm neonates.

19.
China Medical Equipment ; (12): 175-180, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1026426

RESUMO

Objective:To design and construct a remote fault detection method for CT scanning equipment based on two-dimensional search model and ZigBee network to improve the accuracy of fault detection.Methods:ZigBee network technology was used to collect the operating status data of CT scanning equipment from three aspects:environmental factors,electrical factors and gas circuit factors.The time and frequency domain signals were extracted from the monitoring data,and the extracted fault signal feature parameters were fused.The fault data were transformed into stationary time series by inverse binary transformation to restrain the fluctuation of the data.The dependence degree of fault data was calculated by establishing corresponding two-dimensional search model and matching function.Based on this,Bayesian evaluation function was introduced to realize the remote detection of equipment fault.A large-scale clinical CT scanner in clinical use in the hospital was selected as the experimental prototype,and at the same time,550 real fault data generated from the 80 CT scanning scanners with the same model and configuration as the experimental prototype were randomly selected as training samples.The accuracy of CT scanning equipment faults remote detection method with that of the long short-term memory network(referred to as method 1)and deep belief network(referred to as method 2)were compared.Results:The designed remote fault detection method of CT scanning equipment only had detection error on status label 5,but the judgment error was in the controllable range.In the five fault detection experiments,the detection accuracy of the remote fault detection method of CT scanning equipment was more than 80%,which was much higher than that of method 1 and method 2.Conclusion:The fault detection method of CT scanning equipment has a high detection accuracy and can realize the practical requirement of remote detection of CT scanning equipment.

20.
Artigo em Chinês | WPRIM | ID: wpr-1026794

RESUMO

Objective To apply the personal digital assistant(PDA)scanning positioning two-dimensional code recognition technology in writing nursing records in patients with acute ischemic stroke treated with intravenous thrombolysis,and to evaluate the application effect.Methods The quasi-experimental design was conducted.The nursing records routinely written by emergency nurses using mobile nursing cart for 58 patients with acute ischemic stroke treated with intravenous thrombolysis admitted to department of emergency of Zhejiang Hospital from September 2021 to February 2022 was taken as the control group,and the nursing records written by emergency nurses using PDA for 51 patients with acute ischemic stroke treated with intravenous thrombolysis from March 2022 to August 2022 through scanning positioning two-dimensional code recognition technology was used as the observation group.The differences of time required for writing nursing records and the incidence of errors in nursing records were compared between the two groups,and the satisfaction of emergency nurses in the observation group using PDA scanning positioning two-dimensional code to write nursing records was evaluated.Results The time required for writing nursing records in the observation group was significantly shorter than that in the control group[seconds:137(109,192)vs.480(436,604),P<0.05],the incidence of inadequate records of the first course of specialist assessment[3.92%(2/51)vs.20.69%(12/58)],and the incidence of insufficiently detailed records of thrombolytic observations[7.84%(4/51)vs.43.10%(25/58)]were significantly lower than the control group(both P<0.05).The differences between the observation group and the control group were not statistically significant when comparing the incidence of irregularities in thrombolytic drug pump records[0%(0/51)vs.1.72%(1/58)],incidence of irregularities in muscle strength assessment records[1.96%(1/51)vs.5.17%(3/58)],and the occurrence of typos in the nursing records[0%(0/51)vs.3.44%(2/58),all P>0.05].In addition,the overall satisfaction of emergency nurses in the observation group using PDA scanning positioning two-dimensional code to write nursing records was 92.94%(2 844/3 060),and the average score of each item in the synchronous nursing record of the positioning two-dimensional code was>4.5 points,among which the satisfaction score of ease of operation was(4.78±0.50),the acceptance of emergency nurses using PDA scanning positioning two-dimensional code to write nursing records was good,and could meet the clinical needs.Conclusion Using PDA scanning positioning two-dimensional code assists the writing of nursing records in the stroke treatment process,shortens the time required for writing nursing records of emergency nurses,reduces the incidence of errors in nursing records,and improves the quality of nursing records;At the same time,for emergency nurses,it can effectively reduce the burden of writing nursing records and improve their satisfaction with nursing records,which is worthy of clinical promotion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA