Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. j. pharm. sci ; 51(3): 643-651, July-Sept. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-766304

RESUMO

The aim of the present study was to investigate the tissue distribution and excretion of five components of Portulaca oleracea L. extract (POE) in rat following oral administration. A rapid, sensitive and specific ultra-high performance liquid chromatography (UHPLC) method with puerarin as the internal standard was used for the quantitative analysis of five components of POE, including caffeic acid (CA), p-coumaric acid (p-CA), ferulic acid (FA), quercitrin (QUER) and hesperidin (HP) in rat tissues including the liver, intestine, stomach, muscle, heart, lung, brain, kidney and spleen, urine and feces. The results show that onlyp-CA and FA were found in nearly all tissues with low cumulative ratios, and CA was higher in the intestine and stomach with a slightly higher cumulative ratio in the urine and feces after 24 h. HP and QUER were found at low levels in the tissues with low cumulative ratios.


O objetivo do presente estudo foi investigar a distribuição tecidual e excreção de cinco componentes de extrato Portulaca oleracea L. (POE) em ratos após administração oral. Um método analítico rápido, sensível e específico para quantificação de cinco componentes de POE (ácido cafeico (CA), ácidop-cumárico (p-CA), ácido ferúlico (FA), quercitrina (QUER) e hesperidina (HP)) por cromatografia líquida de ultra eficiência (UHPLC), empregando puerarina como padrão interno de referência. Os compostos foram quantificados em diferentes tecidos dos animais, sendo eles fígado, intestino, estômago, músculo, coração, pulmão, cérebro, rim e baço, urina e fezes. Os resultados mostraram que apenas p-CA e FA foram encontradas em todos os tecidos com baixas taxas cumulativas e CA apresentou níveis mais altos no intestino e estômago com a taxa cumulativa um pouco mais elevada na urina e nas fezes após 24 h. HP e QUER apresentaram baixas concentrações nos tecidos com baixas taxas cumulativas.


Assuntos
Ratos , Ratos , Cromatografia Líquida , Portulaca/classificação , Distribuição Tecidual , Compostos Fenólicos
2.
Braz. j. pharm. sci ; 50(2): 301-308, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722181

RESUMO

A simple gradient Ultra Performance liquid chromatographic method (UPLC) was developed for determination of lopinavir and ritonavir from its related impurities and assay for the first time. This method involves the use of a C18 (Acquity UPLC BEH C18, 50 × 2.1 mm, 1.7 µm) column thermostated at 30 oC using triethylamine (pH 2.2): 0.1% H3PO4 in acetonitrile and methanol (85:15) as mobile phase in gradient elution mode. A Photo Diode Array (PDA) detector set at 215 nm was used for detection with flow rate 0.4 mL/min. This method was validated over the range of limit of quantitation (LOQ) to 50 to 150% of impurity specification limit and of working concentration for assay. The developed method was validated for linearity, range, precision, accuracy and specificity. This method was successfully applied for content determination of lopinavir and ritonavir in pharmaceutical formulations. This method can be conveniently used in quality control laboratory for routine analysis for assay and related substances as well as for evaluation of stability samples of bulk drugs and pharmaceutical formulations.


Desenvolveu-se, pela primeira vez, método de cromatografia líquida de ultra-eficiência (UPLC), com gradiente simples, para a determinação de lopinavir e ritonavir e suas impurezas relativas. Esse método envolve o uso de C18 (Acquity UPLC BEH C18, 50 × 2,1 mm, 1,7 µm), termostatizada a 30 oC, utilizando-se trietilamina (pH 2,2) e fase móvel de H3PO4 0,1% em acetonitrila e metanol (85:15), em eluição por gradiente. Detector de arranjo de fotodiiodo (PDA), fixado a 215 nm, foi utilizado para a detecção, com fluxo de 0,4 mL/min. Esse método foi validado em faixa de limite de quantificação (LOQ) de 50 a 150% de limite de impureza e da concentração de trabalho para o ensaio. O método desenvolvido foi validado quanto à linearidade, faixa, precisão, exatidão e especificidade. Esse método foi aplicado com sucesso para a determinação de lopinavir e de ritonavir em formulações farmacêuticas. Tal método pode ser convenientemente utilizado em laboratório de controle de qualidade, não só para análise de rotina e ensaio de substâncias relacionadas, como também para a avaliação da estabilidade de amostras a granel ou em formulações farmacêuticas.


Assuntos
Química Farmacêutica/classificação , Cromatografia Líquida/métodos , Ritonavir/farmacologia , Lopinavir/farmacologia , Contaminação de Medicamentos/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA