Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Rev. bras. ginecol. obstet ; 44(9): 838-844, Sept. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1423282

RESUMO

Abstract Objective The immediate referral of patients with risk factors for placenta accreta spectrum (PAS) to specialized centers is recommended, thus favoring an early diagnosis and an interdisciplinary management. However, diagnostic errors are frequent, even in referral centers (RCs). We sought to evaluate the performance of the prenatal diagnosis for PAS in a Latin American hospital. Methods A retrospective descriptive study including patients referred due to the suspicion of PAS was conducted. Data from the prenatal imaging studies were compared with the final diagnoses (intraoperative and/or histological). Results A total of 162 patients were included in the present study. The median gestational age at the time of the first PAS suspicious ultrasound was 29 weeks, but patients arrived at the PAS RC at 34 weeks. The frequency of false-positive results at referring hospitals was 68.5%. Sixty-nine patients underwent surgery based on the suspicion of PAS at 35 weeks, and there was a 28.9% false-positive rate at the RC. In 93 patients, the diagnosis of PAS was ruled out at the RC, with a 2.1% false-negative frequency. Conclusion The prenatal diagnosis of PAS is better at the RC. However, even in these centers, false-positive results are common; therefore, the intraoperative confirmation of the diagnosis of PAS is essential.


Resumo Objetivo Recomenda-se o encaminhamento imediato de pacientes com fatores de risco para espectro placentário acreta (PAS, na sigla em inglês) para centros especializados, favorecendo assim o diagnóstico precoce e o manejo interdisciplinar. No entanto, erros diagnósticos são frequentes, mesmo em centros de referência (CRs). Buscou-se avaliar o desempenho do diagnóstico pré-natal para PAS em um hospital latino-americano. Métodos Um estudo descritivo retrospectivo incluindo pacientes encaminhados por suspeita de SAP foi realizado. Os dados dos exames de imagem do pré-natal foram comparados com os diagnósticos finais (intraoperatórios e/ou histológicos). Resultados Foram incluídos 162 pacientes no presente estudo. A idade gestacional mediana no momento da primeira ultrassonografia suspeita de PAS foi de 29 semanas, mas as pacientes chegaram ao CR de PAS com 34 semanas. A frequência de resultados falso-positivos nos hospitais de referência foi de 68,5%. Sessenta e nove pacientes foram operadas com base na suspeita de PAS com 35 semanas e houve 28,9% de falso-positivos no CR. Em 93 pacientes, o diagnóstico de PAS foi descartado no CR, com frequência de falso-negativos de 2,1%. Conclusão O diagnóstico pré-natal de PAS é melhor no CR. Entretanto, mesmo nestes centros, resultados falso-positivos são comuns; portanto, a confirmação intraoperatória do diagnóstico de SAP é essencial.


Assuntos
Humanos , Feminino , Gravidez , Placenta Acreta , Procedimentos Cirúrgicos Operatórios , Ultrassonografia Pré-Natal , Ultrassonografia , Reações Falso-Positivas
2.
Braz. dent. sci ; 24(1): 1-6, 2021. tab
Artigo em Inglês | BBO, LILACS | ID: biblio-1145511

RESUMO

Objective: The present study aimed to assess theinfluence of vibration effect on microshear bond strength (µSBS) of flowable composite to enamel. Material and Methods: Sixty non-cariousextracted human premolar teeth were collected and randomly divided into six groups (n = 10) after being trimmed to produce a smooth flat surface: Flowable composites [Wave (SDI), Wave HV (SDI) and Grandioflow (Voco)] were used as bonding agents without or with vibration using an ultrasonic scaler (Mini Piezon, EMS, Switzerland). Composite resin, with an internal diameter of 0.7mm and height of 1mm, was cured on the substrate. The specimens' µSBS was tested by a microtensile tester (Bisco, USA) at a crosshead speed of 0.5 mm/min. The bond strength values were analyzed using one-way ANOVA and post hoc Tukey test (p < 0.05). Results:Vibrationdid not lead to any significant difference in the µSBS values of Wave, Wave HV, and Grandio Flow µSBS values (P=0.690, P=1.000 and P=0.947, respectively). No significant difference was found between flowable composites in terms of micro shear bond strength to enamel (p > 0.05). Conclusions: The application of ultrasonicvibration might not be advantageous in terms of improving the shear bond strength of flowable composites to enamel. (AU)


Objetivo: Este estudo teve como objetivo avaliar a influência de microcisalhamento com efeito de vibração na resistência de união (µSBS) de compósito fluido ao esmalte. Material e Métodos: Sessenta dentes pré-molares humanos extraídos não cariados foram coletados e divididos aleatoriamente em seis grupos (n = 10) após serem desgastados para produzir uma superfície lisa e plana: Compósitos fluidos [Wave (SDI), Wave HV (SDI) e Grandioflow (Voco)] foram usados como agentes adesivos sem e com vibração através de um aparelho ultrassônico (Mini Piezon, EMS, Switzerland). Uma resina composta, com diâmetro interno de 0,7 mm e peso de 1 mm, foi polimerizada no substrato. Os espécimes de µSBS foram submetidos a teste de microtração (Bisco, USA) em uma velocidade de 0.5 mm/min. Os valores de resistência adesiva foram analisados através de testes de ANOVA a um critério e de Tukey post hoc (p < 0.05). Resultados: A vibração não levou a nenhuma diferença significativa nos valores de µSBS entre Wave, Wave HV, e Grandio Flow (P=0.690, P=1.000 e P=0.947, respectivamente). Não foi encontrada nenhuma diferença significativa entre os compósitos fluidos quanto à resistência de união ao esmalte quando sob microcisalhamento (p >0.05). Conclusões: A aplicação de vibração ultrassônica pode não ser vantajosa para uma melhora na resistência adesiva de compósitos fluidos ao esmalte frente a cisalhamento. (AU)


Assuntos
Humanos , Vibração , Dente Pré-Molar , Resinas Compostas , Esmalte Dentário
3.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1008364

RESUMO

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Assuntos
Tomografia com Microscopia Eletrônica , Resistência à Flexão , Ácido Fluorídrico
4.
ABCD (São Paulo, Impr.) ; 28(1): 53-56, 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-742746

RESUMO

BACKGROUND: In traditional laparoscopic cholecistectomy, the cystic duct and artery are commonly closed by metallic clips just before their division. Although the placement of these clips for occluding cystic artery and duct can be considered safe, biliary leaks and bleeding may occur especially by its dislodgement. AIM: To report a prospective case-series in total clipless cholecystectomy by means of harmonic shears for closure and division of the artery and cystic duct as well removal of the gallbladder from the liver. METHODS: Was evaluate a series of 125 patients who underwent laparoscopic cholecystectomy where the sealing and division of cystic artery and duct was carried out only by harmonic shears. The intact extracted gallbladder was submitted to a reverse pressure test for assessment of the technique safety by means of CO2 insuflation. RESULTS: The most common indication for surgery was gallstones. The mean operative time was 26 min and all gallbladders were dissected intact from the liver bed. There was no mortality and the overall morbidity rate was 0.8% with no hemorrhage or leaks. The reverse pressure test showed that all specimens support at least 36-mmHg of pressure without leaking. CONCLUSION: The harmonic shears is effective and safe in laparoscopic cholecystectomy as a sole instrument for sealing and division of the artery and cystic duct. The main advantages could be related to the safety and decreased operative time. .


RACIONAL: A colecistectomia laparoscópica na técnica tradicional oclui o ducto cístico e a artéria cística por clipes cirúrgicos, que podem se deslocar ou desprender no pós-operatório, possibilitando a ocorrência de fístula biliar ou hemorragia. OBJETIVO: Relato prospectivo de série de casos de colecistectomias laparoscópicas sem uso de clipe cirúrgico, sendo que a ligadura e secção da artéria cística e do ducto cístico foram realizadas por meio de bisturi ultrassônico. MÉTODO: Foram incluídos 125 pacientes submetidos à colecistectomia laparoscópica sem utilização de clipe cirúrgico metálico, onde a ligadura da artéria e do ducto cístico e também a remoção da vesícula biliar de seu leito hepático foram realizadas por meio de tesoura ultrassônica. Realizou-se teste de pressão reversa na vesícula biliar removida intacta do leito hepático para verificar a segurança da técnica. RESULTADOS: A principal indicação cirúrgica foi a colelitíase. O tempo cirúrgico médio foi de 26 min e todas as vesículas biliares foram retiradas intactas do leito hepático. Não houve mortalidade e a taxa global de morbidade foi de 0,8%, sem hemorragias ou fístulas. O teste de pressão reversa mostrou que o ducto cístico ocluído pelo bisturi harmônico suportou ao pelo menos 36 mmHg de pressão sem que ocorresse nenhum vazamento. CONCLUSÃO: O bisturi harmônico é eficaz e seguro em colecistectomias laparoscópicas eletivas como um instrumento único para ocluir e seccionar tanto a artéria cística quanto o ducto cístico. Vantagens podem ser apontadas ao método com relação a sua segurança e diminuição do tempo cirúrgico. .


Assuntos
Animais , Humanos , Proteínas de Drosophila/metabolismo , Drosophila melanogaster/efeitos dos fármacos , Drosophila melanogaster/fisiologia , Cloreto de Sódio/farmacologia , Estresse Fisiológico/efeitos dos fármacos , Simportadores/metabolismo , Proteínas de Bactérias/metabolismo , Metabolismo dos Carboidratos/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Drosophila melanogaster/citologia , Drosophila melanogaster/genética , Comportamento Alimentar/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Genes de Insetos , Transporte de Íons/efeitos dos fármacos , Proteínas Luminescentes/metabolismo , Análise de Sequência com Séries de Oligonucleotídeos , Especificidade de Órgãos/efeitos dos fármacos , Filogenia , Interferência de RNA/efeitos dos fármacos , Reprodutibilidade dos Testes , Cloreto de Sódio na Dieta/farmacologia , Análise de Sobrevida , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA