Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
International Neurourology Journal ; : S91-S100, 2018.
Artigo em Inglês | WPRIM | ID: wpr-715860

RESUMO

PURPOSE: Though it is very important obtaining exact data about patients’ voiding patterns for managing voiding dysfunction, actual practice is very difficult and cumbersome. In this study, data about urination time and interval measured by smart band device on patients’ wrist were collected and analyzed to resolve the clinical arguments about the efficacy of voiding diary. By developing a smart band based algorithm for recognition of complex and serial pattern of motion, this study aimed to explore the feasibility of measurement the urination time and intervals for voiding dysfunction management. METHODS: We designed a device capable of recognizing urination time and intervals based on specific postures of the patient and consistent changes in posture. These motion data were obtained by a smart band worn on the wrist. An algorithm that recognizes the repetitive and common 3-step behavior for urination (forward movement, urination, backward movement) was devised based on the movement and tilt angle data collected from a 3-axis accelerometer. The sequence of body movements during voiding has consistent temporal characteristics, so we used a recurrent neural network and long short-term memory based framework to analyze the sequential data and to recognize urination time. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the value of the signals was calculated and then compared with the set analysis model to calculate the time of urination. A comparative study was conducted between real voiding and device-detected voiding to assess the performance of the proposed recognition technology. RESULTS: The accuracy of the algorithm was calculated based on clinical guidelines established by urologists. The accuracy of this detecting device was high (up to 94.2%), proving the robustness of the proposed algorithm. CONCLUSIONS: This urination behavior recognition technology showed high accuracy and could be applied in clinical settings to characterize patients’ voiding patterns. As wearable devices are developed and generalized, algorithms detecting consistent sequential body movement patterns reflecting specific physiologic behavior might be a new methodology for studying human physiologic behavior.


Assuntos
Humanos , Memória de Curto Prazo , Postura , Micção , Punho
2.
International Neurourology Journal ; : S76-S83, 2017.
Artigo em Inglês | WPRIM | ID: wpr-51914

RESUMO

PURPOSE: This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. METHODS: This study aimed to develop an algorithm that recognizes urination based on a patient's posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. RESULTS: An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. CONCLUSIONS: The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.


Assuntos
Humanos , Aceleração , Braço , Postura , Micção , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA