Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Laboratory Medicine and Quality Assurance ; : 211-222, 2018.
Artigo em Coreano | WPRIM | ID: wpr-718772

RESUMO

BACKGROUND: It is known that the blood collection tube used can cause fluctuations in laboratory test results. We compared test results obtained when blood was collected in V-tube (AB Medical, Korea), BD Vacutainer Tubes (BD, USA), and Greiner Vacuette Tubes (Greiner, USA) in clinical chemistry and thyroid hormone assays. METHODS: One hundred volunteers from three hospitals were recruited and the peripheral blood samples were collected in each of the three serum separation tubes (SSTs). These samples were used for 28 routine clinical chemistry assays and three thyroid hormone assays. The results were analyzed by the Student paired t-test and the Bland-Altman plot. For stability tests, the initial results were compared with the day 1 (24±2 hours), day 3 (72±2 hours), and day 7 (168±2 hours) results, respectively. RESULTS: The difference in the test results obtained from the samples in each tube (V-Tube vs. BD-Tube, V-Tube vs. Greiner-Tube, and BD-Tube vs. Greiner-Tube) were satisfied with the Clinical Laboratory Improvement Amendments of 1988 allowable difference ranges. Except for four analytes (low-density lipoprotein cholesterol, magnesium, potassium, and thyroid-stimulating hormone), all analytes were within the allowable critical difference range based on biological variability. The paired t-test revealed significant differences between the results of nine assays for samples in V-Tube vs. BD-Tube and seven assays for samples in V-Tube vs. Greiner-Tube, but each set of results showed good correlations. The test results on different days showed a significant difference in several assays, but they were within the allowable difference range. CONCLUSIONS: The assay results for blood samples collected in SST V-Tubes were comparable to those obtained when blood was collected in BD Tubes and Greiner Tubes, and the blood collected in V-Tubes also showed excellent results in the stability tests.


Assuntos
Humanos , Química , Química Clínica , Colesterol , Lipoproteínas , Magnésio , Potássio , Glândula Tireoide , Vácuo , Voluntários
2.
Laboratory Medicine Online ; : 145-154, 2013.
Artigo em Coreano | WPRIM | ID: wpr-164497

RESUMO

BACKGROUND: Vacuum tubes are widely used in clinical laboratories for routine tests. We compared a newly developed V-tube (AB Medical, Korea) and BD tubes (BD, USA) in common clinical assays, i.e., hematological, chemical, and immunological tests. METHODS: In total, 100 volunteers comprising 79 patients and 21 healthy volunteers were recruited and peripheral blood samples were collected with 2 brands of EDTA tubes and serum-separating tubes (SSTs). EDTA-tube samples were evaluated using 16 routine hematological tests. The SST samples were analyzed for 32 routine chemical parameters and 3 thyroid hormones. The results were statistically analyzed using the paired t-test and Bland-Altman plot. In addition, the stability of each analyte in 2 brands of vacutainers was evaluated. The results of the hematological tests at t=0 hr were compared with those at t=72+/-2 hr, and the results of the chemical parameters and thyroid hormones at t=0 hr were compared with those at t=72+/-2 hr and t=168+/-2 hr for each tube. RESULTS: Paired t-test analysis revealed that the test results of 16 routine hematological parameters, 32 routine chemical parameters, and 3 thyroid hormones showed clinically allowable differences between the 2 brands of vacuum tubes (t=0 hr). The results obtained when using V-tubes showed a statistically significant correlation with those obtained when using BD tubes. The stability of each analyte was similar in both vacuum tubes. Except for 10 parameters (white blood cell count, mean corpuscular volume, basophils [%], mean corpuscular hemoglobin concentration, monocytes [%], phospholipid, sodium, potassium, chloride, and free T4), all parameters showed significant but clinically allowable differences with regard to storage duration. CONCLUSIONS: The newly developed V-tube vacutainers provide a suitable alternative to BD tubes in common clinical laboratories.


Assuntos
Humanos , Basófilos , Contagem de Células Sanguíneas , Ácido Edético , Índices de Eritrócitos , Testes Hematológicos , Monócitos , Potássio , Sódio , Hormônios Tireóideos , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA